903 resultados para FEMORAL-SHAFT FRACTURES
Resultados tratamiento de las fracturas intertrocantéricas en el Hospital Universitario Mayor MEREDÍ
Resumo:
Las fracturas intertrocantericas son una importante causa de la morbimortalidad en los adultos mayores. Requieren la mayoria manejo quirurgico. No se ha logrado definir si es mejor el tratamiento con osteosintesis o artoplastia de cadera. Por esta razon decidimos realizar un estudio identificando los resultados en cada uno de los tratamientos con poblacion colombiana en el Hospital Universitario Mayor Mederi. Metodos: Estudio de serie de casos. Se analizó una cohorte retrospectiva de pacientes mayores de 59 años con fractura intertrocantérica en el Hospital Universitario Mayor Méderi. Resultados: Se reportaron un total de 179 pacientes con diagnóstico de fractura intertrocantérica. De los cuales se realizaron 100 osteosíntesis , 20 reemplazos totales de cadera y 59 hemiartroplastias. La mortalidad fueron 11 pacientes que corresponde al 6.1%, 3 fueron hombres y 8 mujeres, en cuanto al procedimiento realizado a 7 pacientes se les realizo osteosíntesis y a los 4 restantes se les realizo hemiartroplastia. En total 7 infecciones las cuales se presentaron respectivamente en 6 osteosíntesis y 1 hemiartroplastia. Discusión: La mortalidad fue mayor en la osteosíntesis con 7 pacientes que equivale al 63,6 % de la mortalidad total del estudio. Los porcentajes de infección postoperatoria fueron mayores en la osteosíntesis , encontrándose que del total de pacientes intervenidos 3,9% se infectaron y de estos el 85,7 % corresponden a osteosíntesis versus 14,3% de hemiartroplastia. El sangrado postoperatorio fue mayor a 500 cc en un 39% de las osteosíntesis y en un 44% en las hemiartroplastias. Conclusión: el tratamiento de las fracturas intertrocantéricas tuvo menor mortalidad y menor porcentaje de infección cuando los pacientes fueron tratados con hemiartroplastia y reemplazo total de cadera.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Gegenstand der Arbeit: Die distale Radiusfraktur ist der häufigste Bruch des Menschen. Neben etablierten Verfahren wie der dorsalen und palmaren Plattenosteosynthese gibt es seit Kurzem neuartige minimalinvasive Osteosynthesesysteme. Gegenstand der vorliegenden Arbeit ist die Untersuchung der biomechanischen Stabilität von zwei neuartigen Implantaten für die distale extraartikuläre Radiusfraktur. rnMethodik: Es handelt sich einerseits um das System XSCREW (Zimmer, Freiburg i. Br., Deutschland), eine kanülierte Schraube, die über den Processus styloideus eingeführt wird und mit bis zu neun Bohrdrähten im Knochen fixiert werden kann. Das Vergleichsimplantat DorsalNailPlate (HandInnovations, Miami, Florida, USA) ist ein Hybrid aus einer dorsalen Platte und einem Marknagel. Beide Systeme wurden an 8 paarigen frischen unfixierten Leichenradii unter Axialbelastung bis 100 N und Torsionsbelastung bis 1,5 Nm getestet. Die A3-Fraktur wurde durch eine standardisierte Keilosteotomie simuliert. Das Biomaterial wurde prä- und postinterventionell sowie nach einem Dauerbelastungstest unter 1000 Zyklen in Rotation mit 0,5 Hz untersucht. Ein Versagenstest mit steigendem Drehmoment beendete das Experiment. rnErgebnisse: Die XSCREW erreichte eine Axialsteifigkeit von 136 N/mm und eine Torsionssteifigkeit von 0,16 Nm/°. Die DNP erzielte hingegen axial 70 N/mm und torsional 0,06 Nm/°. Der Unterschied zwischen beiden Verfahren war nur für die Torsion eindeutig statistisch auffällig (p=0,012), jedoch nicht für die Axialsteifigkeit (p=0,054). Die ursprüngliche Axial- und Torsionssteifigkeit wurde durch die XSCREW signifikant besser wiederhergestellt als durch die DNP (p=0,012). Beide Verfahren erzielten nach der Intervention signifikant niedrigere Steifigkeiten als die intakten Knochen (p=0,012). Ein Präparat der DNP-Gruppe und vier Präparate der XSCREW-Gruppe überstanden den Dauerbelastungstest. Das Drehmoment bei Versagen war mit der XSCREW höher als mit der DNP, der Unterschied zwischen den Verfahren war signifikant (p=0,043). Die Schwachstellen beider Systeme lagen vorwiegend in der proximalen Verankerung im Knochen. Kirschner-Drähte bzw. Verriegelungsschrauben führten unter andauernder Belastung zu einer Spaltung der Kortikalis im Schaftbereich. Bedingt durch die Ausrichtung der distalen Verriegelungen können mit beiden Implantaten Schäden an der radiocarpalen bzw. radioulnaren Gelenkfläche entstehen. rnZusammenfassung: Die XSCREW ermöglicht insgesamt eine höhere mechanische Stabilität als die DNP. Beide Verfahren sind jedoch einer winkelstabilen palmaren Plattenosteosynthese insbesondere unter rotatorischer Dauerbelastung unterlegen und erreichen nicht die Stabilität eines anderen neuartigen minimalinvasiven Systems.
Resumo:
PURPOSE: To present two new approaches to acetabular surgery that were established in Berne, and which aim at enhanced visualization and anatomical reconstruction of acetabular fractures. METHOD: The trochanteric flip osteotomy allows for surgical hip dislocation, and was introduced as a posterior approach for acetabular fracture management involving the posterior column and wall. For acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach is described. RESULTS: Full exposure of the hip joint, as provided by the trochanteric flip osteotomy, facilitates anatomical reduction of acetabular or femoral head fractures and safe positioning of the anterior column screw in transverse or T-shaped fractures. Additionally, the approach enables osteochondral transplantation as a salvage procedure for severe chondral femoral head damage and osteoplasty of an associated inadequate offset at the femoral head-neck junction. The Pararectus approach allows anatomical restoration with minimal access morbidity, and combines advantages of the ilioinguinal and modified Stoppa approaches. CONCLUSIONS: Utilization of the trochanteric flip osteotomy eases visualization of the superior aspect of the acetabulum, and enables the evaluation and treatment of chondral lesions of the femoral head or acetabulum and labral tears. Displaced fractures of the anterior column with a medialized quadrilateral plate can be addressed successfully through the Pararectus approach, in which surgical access is associated with minimal morbidity. However, long-term results following the two presented Bernese approaches are needed to confirm that in the treatment of complex acetabular fractures the rate of poor results in almost one-third of all cases (as currently yielded using traditional approaches) might be reduced by the utilization of the presented novel approaches.
Resumo:
Osteotomies of the proximal femur and stable fixation of displaced femoral neck fractures are demanding operations. An LCP Paediatric Hip Plate was developed to make these operations safer and less demanding. The article focuses on the surgical technique and critically analyses the device.
Resumo:
Skeletal tuberculosis is now uncommon in developed countries. In immunocompromised patients - particularly in the HIV-infected - who present with subacute or chronic joint pain refractory to conventional treatment, osteoarticular tuberculosis should still be included in the differential diagnosis. We report on a lethal case of disseminated tuberculosis in an HIV-infected subject. Dissemination may have resulted from the implantation of an articular prosthesis in a knee joint with unsuspected osteoarticular tuberculosis. The diagnosis was established months later when the patient presented with far-advanced tuberculous meningitis, miliary tuberculosis of the lungs, femoral osteomyelitis and extended cold abscesses along the femoral shaft. Failure to respond to a conventional four-drug regimen is explained by the resistance pattern of his multi-drug resistant strain of Mycobacterium tuberculosis, which was only reported after the patient's death. This case illustrates the diagnostic challenges of osteoarticular tuberculosis and the consequences of a diagnostic delay in an HIV-infected individual.
Resumo:
AIM: TGF-beta1 is an important local and systemic regulatory molecule during fracture healing. Various authors have shown differences in the systemic levels of TGF-beta1 over the time taken for bone healing in distraction osteogenesis and osteotomies. Previous studies have shown characteristic differences in the physiological levels of growth factors between normal fracture healing and delayed fracture union. The aim of the present study was to evaluate possible differences in sera levels of patients with normal and delayed union fracture healing. METHODS: Patients with long bone shaft fractures were recruited prospectively. Peripheral blood samples were collected over a period of 1 year using a standardized time schedule. At the end of the individual's investigation period, TGF-beta1 levels were determined. To achieve a homogeneous collective of patients, only those with a maximum of two fractures were included in the study. After matching for four criteria, we compared patients with normal fracture healing to patients with delayed unions. The fact of delayed union was accepted in case of failed consolidation 4 months after trauma. RESULTS: During a prospective study period of 1 year, 15 patients with normal fracture healing could be compared to 15 patients suffering from delayed union. By determining the absolute sera levels we found a typical increase of TGF-beta1 up to 2 weeks after fracture in both groups, with a subsequent decrease up to the sixth week after fracture. However, a decline in serum concentration occurred earlier in patients with delayed union, causing significantly lower TGF-beta1 levels in the non-union group 4 weeks after trauma (P=0.00006). CONCLUSION: Even with a relatively small number of patients, we could show a significant difference in serum concentrations of TGF-beta1 between the investigated groups. If these results can be verified within a larger collective, TGF-beta1 could be used as a predictive cytokine for delayed fracture healing.
Resumo:
Since the 1960s the ilioinguinal approach by Letournel with the three anatomic windows has been successfully established for the treatment of acetabular fractures involving predominantly the anterior column. The previous standard approach, the iliofemoral approach by Smith-Petersen, is still used for the therapy of anterior wall or isolated femoral head fractures. The increase in acetabular fractures in the elderly with lateral compression fractures after lateral falls, characterized by medial displacement of the quadrilateral plate and superomedial dome impaction, led to the use of the intrapelvic modified Stoppa approach with or without the first window of the ilioinguinal approach in the 1990s. To combine the advantages of the second and third windows of the ilioinguinal approach and the medial view of the modified Stoppa approach the Berne research group recently introduced the pararectus approach in acetabular surgery, which can be used as a less invasive acetabular surgical (LIAS) technique especially in the elderly.
Resumo:
OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.
Resumo:
Objective: To determine the effect of an early intervention program in an acute care setting on the length of stay in hospital of elderly patients with proximal femoral fractures. Setting: Acute orthopaedic ward of a large teaching hospital. Design and Participants: A randomised controlled trial comparing 38 intervention patients with 33 Standard Care patients. Intervention: Early surgery, minimal narcotic analgesia, intense daily therapy and close monitoring of patient needs via a multidisciplinary approach versus routine hospital management. Main outcome measures: Length of stay (LOS); deaths; level of independent functioning. Results: Mean LOS was shorter in the Intervention group than in the Standard Care group (21 days v. 32.5 days; P<0.01). After adjusting for other factors that could affect LOS (e.g. age, sex, pre-trauma functional levels, pre-trauma comorbidity and postsurgical complications), the Intervention program was significantly predictive of shorter LOS (P=0.01). The Intervention group did not experience greater numbers of deaths, deterioration in function or need for social support than the Standard Care group. Conclusion: This early intervention program in an acute care setting results in significantly shorter length of hospital stay for elderly patients with femoral fractures.
Resumo:
OBJECTIVE: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. METHODS: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively). Group 3 comprised normal controls with BMD changes > or =-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. RESULTS: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively). Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8+/-9.61) and (243.3+/-33.0) mg/cm3, respectively] than in those without [(148.9+/-7.47) and (285.4+/-17.8) mg/cm(3), respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. CONCLUSION: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from those without. vQCT might be useful to evaluate the effect of osteoporotic vertebral fracture status on changes in bone mass in the femoral neck.