984 resultados para Electronic portal imaging device


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Margins are used in radiotherapy to assist in the calculation of planning target volumes. These margins can be determined by analysing the geometric uncertainties inherent to the radiotherapy planning and delivery process. An important part of this process is the study of electronic portal images collected throughout the course of treatment. Set-up uncertainties were determined for prostate radiotherapy treatments at our previous site and the new purpose-built centre, with margins determined using a number of different methods. In addition, the potential effect of reducing the action level from 5 mm to 3 mm for changing a patient set-up, based on off-line bony anatomy-based portal image analysis, was studied. Margins generated using different methodologies were comparable. It was found that set-up errors were reduced following relocation to the new centre. Although a significant increase in the number of corrections to a patient's set-up was predicted if the action level was reduced from 5 mm to 3 mm, minimal reduction in patient set-up uncertainties would be seen as a consequence. Prescriptive geometric uncertainty analysis not only supports calculation and justification of the margins used clinically to generate planning target volumes, but may also best be used to monitor trends in clinical practice or audit changes introduced by new equipment, technology or practice. Simulations on existing data showed that a 3 mm rather than a 5 mm action level during off-line, bony anatomy-based portal imaging would have had a minimal benefit for the patients studied in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The past decade has seen numerous efforts to achieve imaging resolution beyond that of the Abbe-Rayleigh diffraction limit. The main direction of research alining to break this limit seeks to exploit the evanescent components containing fine detail of the electromagnetic field distribution at the Immediate proximity of the object. Here, we propose a solution that removes the need for evanescent fields. The object being imaged or stimulated with subwavelangth accuracy does not need to be In the immediate proximity of the superlens or field concentrator: an optical mask can be designed that creates constructive Interference of waves known as superoscillation, leading to a subwavelength focus of prescribed size and shape in a field of view beyond the evanescent fields, when illuminated by a monochromatic wave. Moreover, we demonstrate that such a mask may be used not only as a focusing device but also as a super-resolution imaging device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’athérosclérose est caractérisée par l’accumulation de lipoprotéines de basse densité (LDL) liées aux protéoglycanes de la paroi artérielle. Des anticorps chimériques (ch) qui se lient aux glycosaminoglycanes (GAG) ont été générés. L'hypothèse est que la vaccination avec le chP3R99, un anticorps chimérique mutant de l'hybridome P3, pouvait interférer avec la rétention des LDL par l’induction d’une cascade d’anticorps anti-idiotypiques dirigés contre les GAG. Des souris mâles déficientes en apolipoprotéine E ont été soumises à une diète hypercholestérolémique et ont reçu 5 injections sous-cutanées de 50 μg de vaccin chP3R99 ou de vaccin chP3S98 (un mutant de faible réactivité). Les injections ont été effectuées à chaque semaine ou aux 2 semaines. Au moment du sacrifice, l'aorte perfusée avec du PBS a été excisée et analysée après coloration au Oil Red-O. Les résultats ont été exprimés en pourcentage de lésions sur la superficie totale de l'aorte. La réactivité contre le chP3R99, chP3S98, l’héparine, le sulfate de dermatane et de chondroïtine des sérums de souris immunisées a été mesurée par ELISA. De plus, la liaison de l'anticorps chP3R99 aux GAG dans la lésion d'athérosclérose a été observée par un appareil de visualisation in vivo.Nos résultats montrent que l’immunogénicité des anticorps chP3R99 est supérieure à celle des anticorps chP3S98 et que le sérum des souris immunisées avec le chP3R99 présente des anticorps anti-idiotypiques dirigés contre les GAG. Cet effet est associé à une réduction de 42 % (p < 0.01) du pourcentage de lésions athérosclérotiques chez les souris vaccinées. L'utilisation d’une immunisation active avec l’anticorps chP3R99 pourrait constituer une approche thérapeutique pour le traitement de l'athérosclérose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT Radiolabelled choline positron emission tomography has changed the management of prostate cancer patients. However, new emerging radiopharmaceutical agents, like radiolabelled prostate specific membrane antigen, and new promising hybrid imaging will begin new challenges in the diagnostic field. OBJECTIVE The continuous evolution in nuclear medicine has led to the improvement in the detection of recurrent prostate cancer (PCa), particularly distant metastases. New horizons have been opened for radiolabelled choline positron emission tomography (PET)/computed tomography (CT) as a guide for salvage therapy or for the assessment of systemic therapies. In addition, new tracers and imaging tools have been recently tested, providing important information for the management of PCa patients. Herein we discuss: (1) the available evidence in literature on radiolabelled choline PET and their recent indications, (2) the role of alternative radiopharmaceutical agents, and (3) the advantages of a recent hybrid imaging device (PET/magnetic resonance imaging) in PCa. EVIDENCE ACQUISITION Data from recently published (2010-2015), original articles concerning the role of choline PET/CT, new emerging radiotracers, and a new imaging device are analysed. This review is reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. EVIDENCE SYNTHESIS In the restaging phase, the detection rate of choline PET varies between 4% and 97%, mainly depending on the site of recurrence and prostate-specific antigen levels. Both 68gallium (68Ga)-prostate specific membrane antigen and 18F-fluciclovine are shown to be more accurate in the detection of recurrent disease as compared with radiolabelled choline PET/CT. Particularly, Ga68-PSMA has a detection rate of 50% and 68%, respectively for prostate-specific antigen levels < 0.5ng/ml and 0.5-2ng/ml. Moreover, 68Ga- PSMA PET/magnetic resonance imaging demonstrated a particularly higher accuracy in detecting PCa than PET/CT. New tracers, such as radiolabelled bombesin or urokinase-type plasminogen activator receptor, are promising, but few data in clinical practice are available today. CONCLUSIONS Some limitations emerge from the published papers, both for radiolabelled choline PET/CT and also for new radiopharmaceutical agents. Efforts are still needed to enhance the impact of published data in the world of oncology, in particular when new radiopharmaceuticals are introduced into the clinical arena. PATIENT SUMMARY In the present review, the authors summarise the last evidences in clinical practice for the assessment of prostate cancer, by using nuclear medicine modalities, like positron emission tomography/computed tomography and positron emission tomography/magnetic resonance imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is just over 20 years since Adobe's PostScript opened a new era in digital documents. PostScript allows most details of rendering to be hidden within the imaging device itself, while providing a rich set of primitives enabling document engineers to think of final-form rendering as being just a sophisticated exercise in computer graphics. The refinement of the PostScript model into PDF has been amazingly successful in creating a near-universal interchange format for complex and graphically rich digital documents but the PDF format itself is neither easy to create nor to amend. In the meantime a whole new world of digital documents has sprung up centred around XML-based technologies. The most widespread example is XHTML (with optional CSS styling) but more recently we have seen Scalable Vector Graphics (SVG) emerge as an XML-based, low-level, rendering language with PostScript-compatible rendering semantics. This paper surveys graphically-rich final-form rendering technologies and asks how flexible they can be in allowing adjustments to be made to final appearance without the need for regenerating a whole page or an entire document. Particular attention is focused on the relative merits of SVG and PDF in this regard and on the desirability, in any document layout language, of being able to manipulate the graphic properties of document components parametrically, and at a level of granularity smaller than an entire page.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supported by contemporary theories of architectural aesthetics and neuro-aesthetics this paper presents a case for the use of portable fNIRS imaging in the assessment of emotional responses to spatial environments experienced by both blind and sighted. The aim of the paper is to outline the implications of fNIRS for spatial research and practice within the field of architecture, thereby suggesting a potential taxonomy of particular formations of space and affect. Empirical neurological study of affect and spatial experience from an architectural design perspective remains in many instances unchartered. Clinical research using the portable non-invasive neuro-imaging device, functional near infrared spectroscopy (fNIRS) is proving convincing in its ability to detect emotional responses to visual, spatio-auditory and task based stimuli, providing a firm basis to potentially track cortical activity in the appraisal of architectural environments. Additionally, recent neurological studies have sought to explore the manifold sensory abilities of the visually impaired to better understand spatial perception in general. Key studies reveal that early blind participants perform as well as sighted due to higher auditory and somato-sensory spatial acuity. For instance, face vision enables the visually impaired to detect environments through skin pressure, enabling at times an instantaneous impression of the layout of an unfamiliar environment. Studies also report pleasant and unpleasant emotional responses such as ‘weightedness’ or ‘claustrophobia’ within certain interior environments, revealing a deeper perceptual sensitivity then would be expected. We conclude with justification that comparative fNIRS studies between the sighted and blind concerning spatial experience have the potential to provide greater understanding of emotional responses to architectural environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Collaboration between neuroscience and architecture is emerging as a key field of research as demonstrated in recent times by development of the Academy of Neuroscience for Architecture (ANFA) and other societies. Neurological enquiry of affect and spatial experience from a design perspective remains in many instances unchartered. Research using portable near infrared spectroscopy (fNIRs) - an emerging non-invasive neuro-imaging device, is proving convincing in its ability to detect emotional responses to visual, spatio-auditory and task based stimuli. This innovation provides a firm basis to potentially track cortical activity in the appraisal of architectural environments. Additionally, recent neurological studies have sought to explore the manifold sensory abilities of the visually impaired to better understand spatial perception in general. Key studies reveal that early blind participants perform as well as sighted due to higher auditory and somato-sensory spatial acuity. Studies also report pleasant and unpleasant emotional responses within certain interior environments revealing a deeper perceptual sensitivity than would be expected. Comparative fNIRS studies between the sighted and blind concerning spatial experience has the potential to provide greater understanding of emotional responses to architectural environments. Supported by contemporary theories of architectural aesthetics, this paper presents a case for the use of portable fNIRS imaging in the assessment of emotional responses to spatial environments experienced by both blind and sighted. The aim of the paper is to outline the implications of fNIRS upon spatial research and practice within the field of architecture and points to a potential taxonomy of particular formations of space and affect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growth direction of ZnO thin films grown by metal-organic chemical vapor deposition (MOCVD) is modulated by pretreatment of (001) SMO3 (STO) substrates. ZnO films show a-oriented smooth surface with epitaxial relationship of < 001 > ZnO//< 110 > STO on as-received SfO, and c-axis columnar growth with < 010 > ZnO//< 110 > STO on etched STO, respectively. The orientation alteration of ZnO films is supposed to be caused by the change of STO surface polarity. In addition, the c-ZnO films exhibit an enhanced photoluminescence (PL) intensity due to the improved crystal quality, while the blueshift of PL peak is attributed to the smaller tensile strain. These results show that high quality c-ZnO, which is essential for electronic and optoelectronic device applications, can be grown on (001) SfO by MOCVD. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditional content-based image retrieval (CBIR) systems use low-level features such as colors, shapes, and textures of images. Although, users make queries based on semantics, which are not easily related to such low-level characteristics. Recent works on CBIR confirm that researchers have been trying to map visual low-level characteristics and high-level semantics. The relation between low-level characteristics and image textual information has motivated this article which proposes a model for automatic classification and categorization of words associated to images. This proposal considers a self-organizing neural network architecture, which classifies textual information without previous learning. Experimental results compare the performance results of the text-based approach to an image retrieval system based on low-level features. (c) 2008 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a novel method of plant classification using Gabor wavelet filters to extract texture filters in a foliar surface. The aim of this promising method is to add to the results obtained by other leaf attributes (such as shape, contour, color, among others), increasing, therefore, the percentage of classification of plant species. To corroborate the efficiency of the technique, an experiment using 20 species from Brazilian flora was done and discussed. The results are also compared with texture Fourier descriptors and cooccurrence matrices. (C) 2009 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 19, 236-243, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/ima.20201

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The clicker is a versatile, easy to use electronic multiple choice device that helps provide instant feedback on what students are learning. In both hybrid and on-site classes, clickers provide a way to rapidly collect an answer to a question from every student; an answer for which they are all individually accountable. In this session, Biological sciences lecturer Rena Quinlan will describe her use of clickers with large classes that help students achieve defined course outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)