983 resultados para Electric network analyzers.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since ancient times, it has been a huge challenge to all people around the world to manage to get their fresh water, keeping it clean and providing it to every human being, so that it can be used for their daily needs. This is especially true for small properties in the countryside and in isolated areas with low demographic density. Pumping the water in those regions is a solution that rationalizes its use in domestic chores, in animal rearing and in the irrigation systems of cultivated areas. Making feasible local, renewable and non-polluted energetic alternatives is the aim for those areas that are usually far away from the public electric network. Using photovoltaic solar energy is the alternative now proposed. For this objective was built a system with two monocrystalline panels, one pump, two water tanks, two level sensors and a solenoid valve to pump water, using a pump powered an array of monocrystalline solar panels. The main goal was to compare their rate of water flow and their energy consumption. The use of one data acquisition equipment allowed collecting meteorological, electrical and hydraulic values, and also serving for the control and activation of the pumping system. During four months in a row as from April 2009, arrangements with one or two panels were tested. Mathematics correlations and adjustment lines were used to interpret the behavior of obtained dataset. During the analyzed period the system followed the linear equations with great accuracy. The daily average amount of water pumped by the several tested arrays stayed between 1,100 and 2,500 liters, and that is enough to supply a small rural property. The pumping system with two panels effectively showed the major amount of water, but a system with one panel can be an economical solution until 1,500 liters on day. It did not characterize a direct relationship between power or quantity of photovoltaic panels and daily outflow of water pumping.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo del presente Proyecto Fin de Grado es la realización de una comparativa de los resultados obtenidos en las medidas de SAR (tasa de absorción específica) y potencia utilizando la normativa europea CENELEC (basada en la del IEC) y la americana FCC (basada en la del IEEE) para distintos dispositivos móviles duales. En primer lugar se ha realizado el estudio de sus características de potencia y de SAR, viendo la variación que hay con respecto a las distintas normativas y rangos de frecuencias. En algunos casos, aunque funcionan sin problema alguno en las diferentes bandas, la diferencia de niveles de emisiones obtenidos en las diferentes bandas puede ser notable. Como se ha comentado al comienzo, se han utilizado diferentes dispositivos duales y se realizaron en ellos las medidas pertinentes utilizando las diferentes normativas y el procedimiento indicado en cada una de ellas. Para observar las diferencias concretas que pudieran existir al utilizar las diferentes normativas, las medidas se han realizado en todas las bandas de funcionamiento del dispositivo y para cada una de ellas se han aplicado las diferentes normativas. Con esto se pretende evaluar si pudiera existir alguna discrepancia en los dispositivos que tienen el certificado de conformidad para una norma concreta cuando se utiliza en otra banda que no es exactamente la banda de utilización de esa norma. En resumen, se quería comprobar que un dispositivo que está certificado con la norma de una región, por ejemplo Europa (900 y 1800 MHz), también cumple si se utiliza en otra región, por ejemplo América (850 y 1900 MHz). La realización práctica del presente PFG se ha hecho en las instalaciones del Laboratorio de Radiofrecuencia de la Secretaría de Estado de Telecomunicación y para la Sociedad de la Información ubicado en El Casar (Guadalajara). En concreto se utilizó el robot articulado movible DASY4 y el software para su control DASY 52.8, disponible en el “banco de medida de Campos Electromagnéticos (Sala de SAR)”. La duración estimada del presente PFG ha sido aproximadamente de cuatro meses. Para llevar a cabo el presente PFG, se dispuso de todo tipo de material y recursos puestos a disposición por el Ministerio de Industria, Turismo y Comercio en el propio laboratorio, así como de los distintos terminales móviles duales con los que se realizaron las medidas pertinentes. Como bibliografía básica se han utilizado las diferentes normas indicadas anteriormente, es decir la norma europea CENELEC (basada en la del IEC) y la americana FCC (basada en la del IEEE), así como manuales de los equipos implicados en el bando de medida de SAR: analizadores de redes, robot articulado y software de control, así como el resto de dispositivos utilizados en las medidas. ABSTRACT. The goal of this Final Degree Project is to perform a comparison of the results obtained in SAR measurements (specific absorption rate) and power using the European standards CENELEC (based on IEC Regulation) and the American FCC (based on IEEE Regulation) to different mobile dual devices. If first place it was made the study of its power and SAR features, seeing that there is shift with respect to the different standards and frequency ranges. In some cases, although they work without any problem in different bands, the difference in levels of emissions obtained in the different bands can be significant. As mentioned at the beginning, different dual devices were used and relevant measurements were taken from them using the different standards and the procedure in each one of them. To see the specific differences that may exist when using the different standards, the measurements were made in all bands of the device operation and to each one it has been applied in the different standards. This attempted to assess whether there could be some discrepancy in the devices that have the certificate of compliance to a specify standard when used in another band that is not exactly the used band of this standard. To sum up, it was required to verify that a device which is certified to the standard of a region, for example (900 and 1800 MHz), also verifies if it is used in another region, for example America (850 and 1900 MHz). The practical realization of this Final Degree Project was made in the facilities of the Radio Frequency Laboratory of the Ministry of State for Telecommunications and the Information Society located in El Casar (Guadalajara). Specifically, the movable articulated robot DASY4 was used and the control software DASY 52.8, available in the “Measure Electromagnetic Field testbench (SAR room)”. The duration of this Final Degree Project has benn about four months. To carry out the present project, all kinds of materials and resources were provided by the Ministry of Industry, Tourism and Trade in its own laboratory, as well as the different mobile dual terminals with which relevant measurements were made. As basic references the different standards indicated above has been used, that is to say the European standard CENELEC (based on IEC standard) and the American FCC (based on IEEE standard), as well as the equipment manuals involved in the SAR measure testbench: network analyzers, articulated robot and control software, as well as the rest of the devices used in the measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bibliography: p. 35.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia Eletrónica e Telecomunicações, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2016

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the last decade of the 19th and first decades of the 20th century there was a movement of capital and engineers from the central and northern Europe to the countries of southern Europe and other continents. Large companies sought to obtain concessions and establish branches in Portugal, favouring the circulation of technical knowledge and transfer of technology for Portuguese industry. Among the various examples of the representatives of foreign companies in Portugal we find Jayme da Costa Ltd. established in 1916 in Lisbon, which was a branch of the Swedish company ASEA, as well as STAAL, ATLAS DIESEL (Sweden), Landis & GYR (Switzerland), Electro Helios, etc.. Another example is EFACEC a company founded in 1948 in Porto, that was a partnership between the Portuguese company CUF – Companhia União Fabril, and ACEC – Ateliers de Constructions Électriques de Charleroi and a small entreprise Electro-Moderna Ldª. This enterprise started the industrial production of electric motors and transformers, and later on acquired a substantial share of the national production of electrical equipment. Using Estatística das Instalações Elétricas em Portugal (Statistics on Electrical Installations in Portugal) from 1928 until 1950 we can identify the foreign enterprises acting in the Portuguese market: Siemens, B.B.C, ASEA, Oerlikon, etc. We can also establish a relationship between the development of the electric network and the growth of production and consumption of electricity in the principal urban centres. Finally we see how foreign firms were a stimulus to the creation of national enterprises, especially those of small scale, in Portugal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An integrated mathematical model for the simulation of an offshore wind system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using multiple point full-power clamped three-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a HVDC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the blades of the wind turbine, tower and generator due to the need to emulate the effects of the wind and the floating motion. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistors of the converter. Finally, a case study is presented to access the system performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The development of an intelligent plug-in electric vehicle (PEV) network is an important research topic in the smart grid environment. An intelligent PEV network enables a flexible control of PEV charging and discharging activities and hence PEVs can be utilized as ancillary service providers in the power system concerned. Given this background, an intelligent PEV network architecture is first developed, and followed by detailed designs of its application layers, including the charging and discharging controlling system, mobility and roaming management, as well as communication mechanisms associated. The presented architecture leverages the philosophy in mobile communication network buildup

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we present the capability of a new network of field mill sensors to monitor the atmospheric electric field at various locations in South America; we also show some early results. The main objective of the new network is to obtain the characteristic Universal Time diurnal curve of the atmospheric electric field in fair weather, known as the Carnegie curve. The Carnegie curve is closely related to the current sources flowing in the Global Atmospheric Electric Circuit so that another goal is the study of this relationship on various time scales (transient/monthly/seasonal/annual). Also, by operating this new network, we may also study departures of the Carnegie curve from its long term average value related to various solar, geophysical and atmospheric phenomena such as the solar cycle, solar flares and energetic charged particles, galactic cosmic rays, seismic activity and specific meteorological events. We then expect to have a better understanding of the influence of these phenomena on the Global Atmospheric Electric Circuit and its time-varying behavior.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work presents a methodology to analyze transient stability (first oscillation) of electric energy systems, using a neural network based on ART architecture (adaptive resonance theory), named fuzzy ART-ARTMAP neural network for real time applications. The security margin is used as a stability analysis criterion, considering three-phase short circuit faults with a transmission line outage. The neural network operation consists of two fundamental phases: the training and the analysis. The training phase needs a great quantity of processing for the realization, while the analysis phase is effectuated almost without computation effort. This is, therefore the principal purpose to use neural networks for solving complex problems that need fast solutions, as the applications in real time. The ART neural networks have as primordial characteristics the plasticity and the stability, which are essential qualities to the training execution and to an efficient analysis. The fuzzy ART-ARTMAP neural network is proposed seeking a superior performance, in terms of precision and speed, when compared to conventional ARTMAP, and much more when compared to the neural networks that use the training by backpropagation algorithm, which is a benchmark in neural network area. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work presents a neural network based on the ART architecture ( adaptive resonance theory), named fuzzy ART& ARTMAP neural network, applied to the electric load-forecasting problem. The neural networks based on the ARTarchitecture have two fundamental characteristics that are extremely important for the network performance ( stability and plasticity), which allow the implementation of continuous training. The fuzzy ART& ARTMAP neural network aims to reduce the imprecision of the forecasting results by a mechanism that separate the analog and binary data, processing them separately. Therefore, this represents a reduction on the processing time and improved quality of the results, when compared to the Back-Propagation neural network, and better to the classical forecasting techniques (ARIMA of Box and Jenkins methods). Finished the training, the fuzzy ART& ARTMAP neural network is capable to forecast electrical loads 24 h in advance. To validate the methodology, data from a Brazilian electric company is used. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work presents a methodology to analyze electric power systems transient stability for first swing using a neural network based on adaptive resonance theory (ART) architecture, called Euclidean ARTMAP neural network. The ART architectures present plasticity and stability characteristics, which are very important for the training and to execute the analysis in a fast way. The Euclidean ARTMAP version provides more accurate and faster solutions, when compared to the fuzzy ARTMAP configuration. Three steps are necessary for the network working, training, analysis and continuous training. The training step requires much effort (processing) while the analysis is effectuated almost without computational effort. The proposed network allows approaching several topologies of the electric system at the same time; therefore it is an alternative for real time transient stability of electric power systems. To illustrate the proposed neural network an application is presented for a multi-machine electric power systems composed of 10 synchronous machines, 45 buses and 73 transmission lines. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we present the results of the use of a methodology for multinodal load forecasting through an artificial neural network-type Multilayer Perceptron, making use of radial basis functions as activation function and the Backpropagation algorithm, as an algorithm to train the network. This methodology allows you to make the prediction at various points in power system, considering different types of consumers (residential, commercial, industrial) of the electric grid, is applied to the problem short-term electric load forecasting (24 hours ahead). We use a database (Centralised Dataset - CDS) provided by the Electricity Commission de New Zealand to this work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)