999 resultados para Dengue detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Biotecnologia - IQ

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To study the antibody prevalence against dengue in the municipality of Jundiai, Sao Paulo, Brazil, due to the low number of official confirmed autochthonous cases. Methods: A serological study on dengue infection was conducted during January 2010 and previous reports on dengue and entomological surveillance during that period were reviewed. Results: A prevalence of 7.8% IgG positive (68:876) was found. Furthermore, based on the detection of IgM antibodies in five samples, it was observed that the incidence of dengue in the city at the time of the survey contrasts with the absence of notifications by local health authorities over the same period of time. Conclusion: These results highlight the discrepancies between the actual and the detected number of dengue infections, possibly due to significant numbers of asymptomatic infections aggravated by difficulties with dengue clinical diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 2010, a large outbreak of dengue occurred in Santos, Brazil. The detection of the NS1 antigen was used for diagnosis in addition to the detection of IgG, IgM, and RNA. A large number of NS1 false-negative results were obtained. A total of 379 RNA-positive samples were selected for thorough evaluation. NS1 was reactive in 37.7% of cases. Most of the cases were characterized as a secondary infection by dengue 2 virus. Sequencing of NS1 positive and negative isolates did not reveal any mutation that could justify the diagnostic failure. Use of existing NS1 tests in the Brazilian population may present a low negative predictive value, and they should be used with caution, preferentially after performing a validation with samples freshly obtained during the ongoing epidemic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Dengue epidemics have been reported in Brazil since 1981. In Manaus, a large city in the Amazon region, dengue is endemic with all four-virus serotypes (DENV-1, -2, -3, and -4) simultaneously causing human disease. In 2008, during a surveillance of dengue virus in mosquitoes in the district of Tancredo Neves in Manaus, 260 mosquitoes of Aedes genus were captured, identified and grouped into pools of 10 mosquitoes. Findings RNA extracts of mosquito pools were tested by a RT-Hemi-Nested-PCR for detection of flaviviruses. One amplicon of 222 bp, compatible with dengue virus serotype 4, was obtained from a pool of Aedes aegypti. The nucleotide sequence of the amplicon indicated that the mosquitoes were infected with DENV-4 of genotype I. This virus of Asian origin has been described in Manaus in 2008 infecting acute febrile illness patients. Conclusion This is the first report of dengue virus serotype 4 genotype I infecting Aedes aegypti in the Americas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To study the antibody prevalence against dengue in the municipality of Jundiaí, São Paulo, Brazil, due to the low number of official confirmed autochthonous cases. METHODS: A serological study on dengue infection was conducted during January 2010 and previous reports on dengue and entomological surveillance during that period were reviewed. RESULTS: A prevalence of 7.8% IgG positive (68:876) was found. Furthermore, based on the detection of IgM antibodies in five samples, it was observed that the incidence of dengue in the city at the time of the survey contrasts with the absence of notifications by local health authorities over the same period of time. CONCLUSION: These results highlight the discrepancies between the actual and the detected number of dengue infections, possibly due to significant numbers of asymptomatic infections aggravated by difficulties with dengue clinical diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opportunistic diseases caused by Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV) is an omnipresent global challenge. In order to manage these epidemics, we need to have low cost and easily deployable platforms at the point-of-care in high congestions regions like airports and public transit systems. In this dissertation we present our findings in using Localized Surface Plasmon Resonance (LSPR)-based detection of pathogens and other clinically relevant applications using microfluidic platforms at the point-of-care setting in resource constrained environment. The work presented here adopts the novel technique of LSPR to multiplex a lab-on-a-chip device capable of quantitatively detecting various types of intact viruses and its various subtypes, based on the principle of a change in wavelength occurring when metal nano-particle surface is modified with a specific surface chemistry allowing the binding of a desired pathogen to a specific antibody. We demonstrate the ability to detect and quantify subtype A, B, C, D, E, G and panel HIV with a specificity of down to 100 copies/mL using both whole blood sample and HIV-patient blood sample discarded from clinics. These results were compared against the gold standard Reverse Transcriptase Polymerase Chain Reaction (RT-qPCR). This microfluidic device has a total evaluation time for the assays of about 70 minutes, where 60 minutes is needed for the capture and 10 minutes for data acquisition and processing. This LOC platform eliminates the need for any sample preparation before processing. This platform is highly multiplexable as the same surface chemistry can be adapted to capture and detect several other pathogens like dengue virus, E. coli, M. Tuberculosis, etc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the development of a capture enzyme-linked immunosorbent assay for the detection of the dengue virus nonstructural protein NS1. The assay employs rabbit polyclonal and monoclonal antibodies as the capture and detection antibodies, respectively. Immunoaffinity-purified NS1 derived from dengue 2 virus-infected cells was used as a standard to establish a detection sensitivity of approximately 4 ng/ml for an assay employing monoclonal antibodies recognizing a dengue 2 serotype-specific epitope. A number of serotype cross-reactive monoclonal antibodies were also shown to be suitable probes for the detection of NS1 expressed by the remaining three dengue virus serotypes. Examination of clinical samples demonstrated that the assay was able to detect NS1 with minimal interference from serum components at the test dilutions routinely used, suggesting that it could form the basis of a useful additional diagnostic test for dengue virus infection. Furthermore, quantitation of NS1 levels in patient sera may prove to be a valuable surrogate marker for viremia. Surprisingly high levels of NS1, as much as 15 mu g/ml, were found in acute-phase sera taken hom some of the patients experiencing serologically confirmed dengue 2 virus secondary infections but was not detected in the convalescent sera of these patients. In contrast, NS1 could not be detected in either acute-phase or convalescent serum samples taken from patients with serologically confirmed primary infection. The presence of high levels of secreted NS1 in the sera of patients experiencing secondary dengue virus infections, and in the context of an anamnestic antibody response, suggests that NS1 may contribute significantly to the formation of the circulating immune complexes that are suspected to play an important role in the pathogenesis of severe dengue disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dengue is an acute infectious disease, usually transmitted by Aedes aegypti mosquitoes. The etiologic agents belong to the family Flaviviridae, genus Flavivirus, and occur as four antigenically related but distinct serotypes designated DENV-1, 2, 3, and 4. In Brazil, the disease represents a national public health problem. The purpose of the present study was to describe epidemiological aspects of dengue in the State of Rio Grande do Norte, from 2013 to 2014. A total of 483 blood or serum samples, collected from January 2013 to December 2014, were studied by RT-PCR for viral detection and typing. The infection was confirmed in 36.44% (176/483) of the cases studied. This study detected the circulation of three serotypes of dengue virus in Rio Grande do Norte, DENV-1, 2, and 4. The predominant serotype in 2013-2014 was the DENV-4, representing 83.51% (81/97) and 68.35% (54/79) of the positive cases, respectively. Regarding the spatial distribution, most of the cases occurred in Natal and Caicó, with 9.28% (9/97) and 18.99% (15/79), respectively. The months with the biggest viral circulation in RN were March 2013 and May 2014. The female gender was the most affected, representing 69.07% (67/97) in 2013 and 54.43% (43/79) in 2014. The most affected age groups were 21-30 years (2013) and 11-20 years (2014) with 25.77% (25/97) and 20.25% (16/79) positive cases, respectively. Phylogenetic analysis indicated that genotype V (DENV-1) and genotype II (DENV-4) circulated in the State. Our results provide information about the dynamics of DENV in the Rio Grande do Norte, important for the development of disease control strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dengue virus (DENV) infections represent a significant concern for public health worldwide, being considered as the most prevalent arthropod-borne virus regarding the number of reported cases. In this study, we report the complete genome sequencing of a DENV serotype 4 isolate, genotype II, obtained in the city of Manaus, directly from the serum sample, applying Ion Torrent sequencing technology. The use of a massive sequencing technology allowed the detection of two variable sites, one in the coding region for the viral envelope protein and the other in the nonstructural 1 coding region within viral populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bleeding complications in dengue may occur irrespective of the presence of plasma leakage. We compared plasma levels of modulators of the endothelial barrier among three dengue groups: bleedings without plasma leakage, dengue hemorrhagic fever, and non-complicated dengue. The aim was to evaluate whether the presence of subtle alterations in microvascular permeability could be detected in bleeding patients. Plasma levels of VEGF-A and its soluble receptors were not associated with the occurrence of bleeding in patients without plasma leakage. These results provide additional rationale for considering bleeding as a complication independent of endothelial barrier breakdown, as proposed by the 2009 WHO classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basic reproduction number is a key parameter in mathematical modelling of transmissible diseases. From the stability analysis of the disease free equilibrium, by applying Routh-Hurwitz criteria, a threshold is obtained, which is called the basic reproduction number. However, the application of spectral radius theory on the next generation matrix provides a different expression for the basic reproduction number, that is, the square root of the previously found formula. If the spectral radius of the next generation matrix is defined as the geometric mean of partial reproduction numbers, however the product of these partial numbers is the basic reproduction number, then both methods provide the same expression. In order to show this statement, dengue transmission modelling incorporating or not the transovarian transmission is considered as a case study. Also tuberculosis transmission and sexually transmitted infection modellings are taken as further examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.