971 resultados para Degree of freedom
Resumo:
Background. - Tardive dyskinesia (TD) is a movement disorder observed after chronic neuroleptic treatment. Smoking is presumed to increase the prevalence of TD. The question of a cause-effect-relationship between smoking and TD, however, remains to be answered. Purpose of this study was to examine the correlation between the degree of smoking and the severity of TD with respect to differences caused by medication. Method. - We examined 60 patients suffering from schizophrenia and TD, We compared a clozapine-treated group With a group treated with typical neuroleptics. Movement disorders were assessed using the Abnormal-Involuntary-Movement-Scale and the technical device digital image processing, providing rater independent information on perioral movements. Results. - We found a strong correlation (.80 < r < .90, always p < .0001) between the degree of smoking and severity of TD. Repeated measurements revealed a positive correlation between changes in cigarette consumption and changes of the severity of TD (p < .0001). Analyses of covariance indicated a significant group-effect with a lower severity of TD in the clozapine-group compared to the typical-neuroleptics-group (p = .010). Interaction-analyses indicated a higher impact of smoking oil the severity of TD in the typical-neuroleptics-group compared to the clozapine-group (p = .033). Conclusion. - Concerning a possible cause-effect-relationship between smoking and TD, smoking is more of a general health hazard than neuroleptic exposure in terms of TD. (C) 2008 Elsevier Masson SAS. All rights reserved.
Resumo:
We tested the hypothesis that at the early phase of acute lung injury (ALI) the degree of endothelium injury may predict lung parenchyma remodelling For this purpose, two models of extrapulmonary ALI induced by Escherichia col: lipopolysaccharide (ALI-LPS) or cecal ligation and puncture (ALI-CLP) were developed in mice At day 1, these models had similar degrees of lung mechanical compromise, epithelial damage, and intraperitoneal inflammation, but endothelial lesion was greater in ALI-CLP A time course analysis revealed, at day 7 ALI-CLP had higher degrees of epithelial lesion, denudation of basement membrane, endothelial damage, elastic and collagen fibre content, neutrophils in bronchoalveolar lavage fluid (BALF), peritoneal fluid and blood, levels of interleukin-6, KC (murine analogue of IL-8), and transforming growth factor-beta in BALF Conversely, the number of lung apoptotic cells was similar in both groups In conclusion, the intensity of fibroelastogenesis was affected by endothelium injury in addition to the maintenance of epithelial damage and intraperitoneal inflammation. (C) 2010 Elsevier B V All rights reserved
Resumo:
Multiple sclerosis (MS) is an autoimmune disease causing severe neurological disability. This study was carried out in order to determine whether the MMP-9 C(-1562)T and (CA)(13-25) polymorphisms are associated with MS. A total of 165 patients (92 whites/73 mulattos) and 191 controls (96 whites/95 mulattos) were enrolled in the study. While no difference in C(-1562)T polymorphism was observed between MS and healthy subjects, (CA)(n) genotypes and alleles were associated with MS. Moreover, the haplotypes are not associated with MS but seem to be relevant to the clinical status of MS. Thus the (CA)(n) polymorphism may contribute to MS susceptibility, but C(-1562)T and (CA)(n) haplotypes may modulate disease severity. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objectives. This study evaluated the effect of composite pre-polymerization temperature and energy density on the marginal adaptation (MA), degree of conversion (DC), flexural strength (FS), and polymer cross-linking (PCL) of a resin composite (Filtek Z350, 3M/ESPE). Methods. For MA, class V cavities (4mmx2mmx2mm) were prepared in 40 bovine incisors. The adhesive system Adper Single Bond 2 (3M/ESPE) was applied. Before being placed in the cavities, the resin composite was either kept at room-temperature (25 degrees C) or previously pre-heated to 68 degrees C in the Calset (TM) device (AdDent Inc., Danbury, CT, USA). The composite was then light polymerized for 20 or 40s at 600mW/cm(2) (12 or 24 J/cm(2), respectively). The percentage of gaps was analyzed by scanning electron microscopy, after sectioning the restorations and preparing epoxy resin replicas. DC (n = 3) was obtained by FT-Raman spectroscopy on irradiated and non-irradiated composite surfaces. FS (n = 10) was measured by the three-point-bending test. KHN (n = 6) was measured after 24h dry storage and again after immersion in 100% ethanol solution for 24 h, to calculate PCL density. Data were analyzed by appropriate statistical analyses. Results. The pre-heated composite showed better MA than the room-temperature groups. A higher number of gaps were observed in the room-temperature groups, irrespective of the energy density, mainly in the axial wall (p < 0.05). Composite pre-heating and energy density did not affect the DC, FS and PCL (p > 0.05). Significance. Pre-heating the composite prior to light polymerization similar in a clinical situation did not alter the mechanical properties and monomer conversion of the composite, but provided enhanced composite adaptation to cavity walls. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To determine the influence of rate of polymerization, degree of conversion and volumetric shrinkage on stress development by varying the amount of photoinitiators in a model composite. Methods: Volumetric shrinkage (with a mercury dilatometer), degree of conversion, maximum rate of reaction (RP(max)) (with differential scanning calorimetry) and polymerization stress (with a controlled compliance device) were evaluated. Bis-GMA/TEGDMA (equal mass ratios) were mixed with a tertiary amine (EDMAB) and camphorqpinone, respectively, in three concentrations (wt%): high= 0.8/1.6; intermediate= 0.4/0.8 and low= 0.2/0.4. 80 wt% filler was added. Composites were photoactivated (400 mW/cm(2) x 40 seconds; radiant exposure=16J/cm(2)). A fourth experimental group was included in which the low concentration formulation was exposed for 80 seconds (32 J/cm(2)). Results: For the same radiant exposure, conversion, RP(max) and stress increased with photoinitiator concentration (P< 0.001). When the low concentration group exposed to 32 J/cm(2) was compared with the high and intermediate groups (exposed to 16 J/cm(2)), RPmax Still increased with the photoinitiator concentration between all levels (P< 0.001) but conversion and stress did not vary (P> 0.05). Shrinkage did not vary regardless of the photoinitiator concentration or radiant exposure. For the photoinitiator concentrations used in this study. Polymerization stress was influenced by conversion but not by rate of reaction. (Am J Dent 2009;22:206-210).
Resumo:
Objective. This study evaluated the degree of conversion (DC), maximum rate of cure (R(p)(max)), and polymerization stress (PS) developed by an experimental dental composite subjected to different irradiant energies (3,6,12, 24, or 48J/cm(2)) under constant irradiance (500 mw/cm(2)). Methods. DC and R(p)(max) were monitored for 10 min on the bottom surface of 2-mm thick disks and on 150-mu m thick films (representing the top of the specimen) using ATR-FTIR. PS was monitored for 10 min in 2-mm thick disks bonded to two glass rods (O = 5 mm) attached to a universal testing machine. One-way ANOVA/Tukey tests were used and differences in DC and R(p)(max) between top and bottom surfaces were examined using Student`s t-test. Statistical testing was performed at a pre-set alpha of 0.05. Results. For a given surface, DC showed differences among all groups, except at the top between 24 and 48 J/cm(2). R(p)(max) was similar among all groups at the same surface and statistically higher at the top surface. PS also showed significant differences among all groups. Data for 48 J/cm(2) were not obtained due to specimen failure at the glass/composite interface. Significance. Increases in irradiant exposure led to significant increases in DC and PS, but had no effect on R(p)(max) (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: Verify the influence of radiant exposure (H) on composite degree of conversion (DC) and mechanical properties. Methods: Composite was photoactivated with 3, 6, 12, 24, or 48 J/cm(2). Properties were measured after 48-h dry storage at room temperature. DC was determined on the flat surfaces of 6 mm x 2 mm disk-shaped specimens using FTIR. Flexural strength (FS) and modulus (FM) were accessed by three-point bending. Knoop microhardness number (KHN) was measured on fragments of FS specimens. Data were analyzed by one-way ANOVA/Tukey test, Student`s t-test, and regression analysis. Results: DC/top between 6 and 12 J/cm(2) and between 24 and 48 J/cm(2) were not statistically different. No differences between DC/top and bottom were detected. DC/bottom, FM, and KHN/top showed significant differences among all H levels. FS did not vary between 12 and 24 J/cm(2) and between 24 and 48 J/cm(2). KHN/bottom at 3 and 6 J/cm(2) was similar. KHN between top and bottom was different up to 12 J/cm(2). Regression analyses having H as independent variable showed a plateau region above 24 J/cm(2). KHN increased exponentially (top) or linearly (bottom) with DC. FS and FM increased almost linearly with DC/bottom up to 55% conversion. Conclusions: DC and mechanical properties increased with radiant exposure. Variables leveled off at high H levels. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Purpose: To evaluate early and 24-hour microtensile bond strength (mu TBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. Methods: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer`s instructions (n= 10). One half was immediately sectioned into sticks and subjected to mu TBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey`s tests. Results: There were no significant differences between the 1-hour and 24-hour bond strengths (P> 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P> 0.05). However, significant differences were observed among adhesives (P< 0.05). mu TBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).
Resumo:
Purpose: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. Methods: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene`s test, one and three-way ANOVA, and Tukey HSD test (alpha= 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram. (Am J Dent 2011;24:115-118).
Resumo:
Objective: To evaluate soft tissue characteristics in individuals with cleft lip and palate and the degree of satisfaction of these individuals after rehabilitation. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, Brazil. Patients: Forty-five individuals with repaired complete unilateral cleft lip and palate, aged 15 to 30 years. Interventions: One hundred thirty-five frontal facial photographs were obtained at rest and in natural and forced smile. Specialists in periodontics evaluated the soft tissue characteristics. Both patients and specialists evaluated the smiles and scored them as esthetically unpleasant, acceptable, or pleasant. Main Outcome Measures: Comparison of the cleft area with the contralateral region was performed for evaluation of soft tissue. The results of the degree of satisfaction with smile were expressed as percentages and means. The findings between patients and periodontists experienced or inexperienced with cleft care were compared. Results: Statistically significant differences were observed for alveolar process deficiency and absence of papilla in the esthetic area between groups (p < .05). Results show 84.4% of individuals considered their smile as esthetically pleasant. Specialists in periodontics of both groups scored the natural smile and forced smile as esthetically acceptable. There was a statistically significant difference in the mean of patients compared with both groups of specialists in periodontics (p < .05). Conclusions: Evaluation and knowledge of the soft tissue characteristics is extremely important for successful rehabilitation. The esthetic values and degree of patient satisfaction are essential for treatment success, since smile reconstruction should be esthetically pleasant to the patient.
Resumo:
Objectives. The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction (C), elastic modulus (E), and glass transition temperature (T(g)) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods. Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and T(g) was measured by differential scanning calorimetry (DSC). Data were submitted to two-and three-way ANOVA, and linear regression analyses. Results. ED, PD, and mode of cure influenced DC, C, E, and T(g) of the polymer. A significant positive correlation was found between ED and DC (r = 0.58), ED and E (r = 0.51), and ED and T(g) (r = 0.44). Taken together, ED and PD were significantly related to DC and E. The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C (r = 0.54), DC and E (r = 0.61), and DC and T(g) (r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C, and decreased T(g). Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Within a 199 866 base pair (bp) portion of a Plasmodium vivax chromosome we identified a conserved linkage group consisting of at least 41 genes homologous to Plasmodium falciparum genes located on chromosome 3. There were no P. vivax homologues of the P. falciparum cytoadherence-linked asexual genes clag 3.2, clag 3.1 and a var C pseudogene found on the P. vivax chromosome. Within the conserved linkage group, the gene order and structure are identical to those of P. falciparum chromosome 3. This conserved linkage group may extend to as many as 190 genes. The subtelomeric regions are different in size and the P. vivax segment contains genes for which no P. falciparum homologues have been identified to date. The size difference of at least 900 kb between the homologous P. vivax chromosome and P. falciparum chromosome 3 is presumably due to a translocation. There is substantial sequence divergence with a much higher guanine + cytosine (G + C) content in the DNA and a preference for amino acids using GC-rich codons in the deduced proteins of P. vivax. This structural conservation of homologous genes and their products combined with sequence divergence at the nucleotide level makes the P. vivax genome a powerful tool for comparative analyses of Plasmodium genomes. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The divergence of quantum and classical descriptions of particle motion is clearly apparent in quantum tunnelling(1,2) between two regions of classically stable motion. An archetype of such nonclassical motion is tunnelling through an energy barrier. In the 1980s, a new process, 'dynamical' tunnelling(1-3), was predicted, involving no potential energy barrier; however, a constant of the motion (other than energy) still forbids classically the quantum-allowed motion. This process should occur, for example, in periodically driven, nonlinear hamiltonian systems with one degree of freedom(4-6). Such systems may be chaotic, consisting of regions in phase space of stable, regular motion embedded in a sea of chaos. Previous studies predicted(4) dynamical tunnelling between these stable regions. Here we observe dynamical tunnelling of ultracold atoms from a Bose-Einstein condensate in an amplitude-modulated optical standing wave. Atoms coherently tunnel back and forth between their initial state of oscillatory motion (corresponding to an island of regular motion) and the state oscillating 180 degrees out of phase with the initial state.
Resumo:
Two experiments using a temporal occlusion paradigm (the first with expert and novice participants and the second with participants of intermediate skill) were conducted to examine the capability of tennis players to predict the direction of an opponent's service in situ. In both experiments two different response conditions, reflecting differing degrees of perception-action coupling, were employed. In a coupled condition players were required to make a movement-based response identical to that which they would use to hit a return of service in a game situation, whereas in an uncoupled condition a verbal prediction of service direction was required. Experiment 1 provided clear evidence of superior prediction accuracy under the coupled response condition when ball flight was available, plus some limited evidence to suggest that superior prediction accuracy under uncoupled response conditions might hold true if only advance (pre-contact) information was available. Experiment 2 showed the former finding to be a robust one, but was unable to reveal any support for the latter. Experiment 1 also revealed that expert superiority is more apparent for predictions made under natural (coupled) than uncoupled response-mode conditions. Collectively, these findings suggest that different perceptual processes may be in operation in anticipatory tasks which depend on skill level, the type of information presented, and degree of perception-action coupling inherent in the task requirements.