981 resultados para DENTAL ABUTMENTS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Passive fit has been considered an important requirement for the longevity of implant-supported prostheses. Among the different steps of prostheses construction, casting is a feature that can influence the precision of fit and consequently the uniformity of possible deformation among abutments upon the framework connection. Purpose: This study aimed at evaluating the deformation of abutments after the connection of frameworks either cast in one piece or after soldering. Materials and Methods: A master model was used to simulate a human mandible with 5 implants. Ten frameworks were fabricated on cast models and divided into 2 groups. Strain gauges were attached to the mesial and distal sides of the abutments to capture their deformation after the framework’s screw retentions were tightened to the abutments. Results: The mean values of deformation were submitted to a 3-way analysis of variance that revealed significant differences between procedures and the abutment side. The results showed that none of the frameworks presented a complete passive fit. Conclusion: The soldering procedure led to a better although uneven distribution of compression strains on the abutments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the biological and technical complication rates of fixed dental prostheses (FDP) with end abutments or cantilever extensions on teeth (FDP-tt/cFDP-tt) on implants (FDP-ii/cFDP-ii) and tooth-implant-supported (FDP-ti/cFDP-ti) in patients treated for chronic periodontitis. Material and methods: From a cohort of 392 patients treated between 1978 and 2002 by graduate students, 199 were re-examined in 2005. Of these, 84 patients had received ceramo-metal FDPs (six groups). Results: At the re-evaluation, the mean age of the patients was 62 years (36.2–83.4). One hundred and seventy-five FDPs were seated (82 FDP-tt, 9 FDP-ii, 20 FDP-ti, 39 cFDP-tt, 15 cFDP-ii, 10 cFDP-ti). The mean observation time was 11.3 years; 21 FDPs were lost, and 46 technical and 50 biological complications occurred. Chances for the survival of the three groups of FDPs with end abutments were very high (risk for failure 2.8%, 0%, 5.6%). The probability to remain without complications and/or failure was 70.3%, 88.9% and 74.7% in FDPs with end abutments, but 49.8–25% only in FDPs with extensions at 10 years. Conclusions: In patients treated for chronic periodontitis and provided with ceramo-metal FDPs, high survival rates, especially for FDPs with end abutments, can be expected. The incidence rates of any negative events were increased drastically in the three groups with extension cFDPs (tt, ii, ti). Strategic decisions in the choice of a particular FDP design and the choice of teeth/implants as abutments appear to influence the risks for complications to be expected with fixed reconstruction. If possible, extensions on tooth abutments should be avoided or used only after a cautious clinical evaluation of all options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. MATERIALS AND METHODS Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. RESULTS Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. CONCLUSIONS Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teeth are often included in the radiation field during head and neck radiotherapy, and recent clinical evidence suggests that dental pulp is negatively affected by the direct effects of radiation, leading to impaired sensitivity of the dental pulp. Therefore, this study aimed to investigate the direct effects of radiation on the microvasculature, innervation, and extracellular matrix of the dental pulp of patients who have undergone head and neck radiotherapy. Twenty-three samples of dental pulp from patients who finished head and neck radiotherapy were analyzed. Samples were histologically processed and stained with hematoxylin-eosin for morphologic evaluation of the microvasculature, innervation, and extracellular matrix. Subsequently, immunohistochemical analysis of proteins related to vascularization (CD34 and smooth muscle actin), innervation (S-100, NCAM/CD56, and neurofilament), and extracellular matrix (vimentin) of the dental pulp was performed. The morphologic study identified preservation of the microvasculature, nerve bundles, and components of the extracellular matrix in all studied samples. The immunohistochemical analysis confirmed the morphologic findings and showed a normal pattern of expression for the studied proteins in all samples. Direct effects of radiotherapy are not able to generate morphologic changes in the microvasculature, innervation, and extracellular matrix components of the dental pulp in head and neck cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy dispersive X-ray spectroscopy microanalysis (EDX), scanning electron microscopy (SEM), and Archimedes' Principle were used to determine the characteristics of inorganic filler particles in five dental alginates, including Cavex ColorChange (C), Hydrogum 5 (H5), Hydrogum (H), Orthoprint (O), and Jeltrate Plus (JP). The different alginate powders (0.5 mg) were fixed on plastic stubs (n = 5) and sputter coated with carbon for EDX analysis, then coated with gold, and observed using SEM. Volume fractions were determined by weighing a sample of each material in water before and after calcining at 450(°)C for 3 h. The alginate materials were mainly composed of silicon (Si) by weight (C-81.59%, H-79.89%, O-78.87%, H5-77.95%, JP-66.88%, wt). The filler fractions in volume (vt) were as follows: H5-84.85%, JP-74.76%, H-70.03%, O-68.31%, and C-56.10%. The tested materials demonstrated important differences in the inorganic elemental composition, filler fraction, and particle morphology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reasons for the iniquities of caries, globally recognized, may be related to how Cariology has been taught in dental schools. In Brazil, the most important universities, when considering healthcare teaching, are the public ones. The objective of this study was to identify the insertion of the contents of Cariology in the course flowcharts of public dental schools in the country. The survey was conducted in 2013 seeking to identify the realities of different geographical regions, aimed to the census of public dental schools. It was performed a documentary analysis of the menus of disciplines, identifying the following issues: number of dental schools that include content related to Cariology in their curricula; average total workload undergraduate courses and disciplines that contemplate the theme; distribution of disciplines in professional training cycles (basic, clinical and public health); existence of discipline and/or a specific department; verification of bibliographic indication directly related to Cariology. The response rate was 93.6%. All dental schools recommended specific books, and none of them had a Department of Cariology. All dental schools in the country contemplated content related to Cariology in their disciplines, distributed in specific disciplines (except for the Northern region) and disciplines in the three cycles of learning (basic, clinical and public health), with larger workload in the clinical cycle. Although public dental schools in Brazil demonstrated commitment to contemplating the content related to Cariology in their disciplines, the emphasis on the clinical cycle may not be promoting the integrated formation of students, which could be contributing to reflect the inequalities of the disease in the country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the performance of the Centers for Dental Specialties (CDS) in the country and associations with sociodemographic indicators of the municipalities, structural variables of services and primary health care organization in the years 2004-2009. The study used secondary data from procedures performed in the CDS to the specialties of periodontics, endodontics, surgery and primary care. Bivariate analysis by χ2 test was used to test the association between the dependent variable (performance of the CDS) with the independents. Then, Poisson regression analysis was performed. With regard to the overall achievement of targets, it was observed that the majority of CDS (69.25%) performance was considered poor/regular. The independent factors associated with poor/regular performance of CDS were: municipalities belonging to the Northeast, South and Southeast regions, with lower Human Development Index (HDI), lower population density, and reduced time to deployment. HDI and population density are important for the performance of the CDS in Brazil. Similarly, the peculiarities related to less populated areas as well as regional location and time of service implementation CDS should be taken into account in the planning of these services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey's. The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. The bracket bond presence affected the effectiveness of both the home and office bleaching treatments. Key words:Tooth bleaching, spectrophotometry, orthodontics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several medical and dental schools have described their experience in the transition from conventional to digital microscopy in the teaching of general pathology and histology disciplines; however, this transitional process has scarcely been reported in the teaching of oral pathology. Therefore, the objective of the current study is to report the transition from conventional glass slide to virtual microscopy in oral pathology teaching, a unique experience in Latin America. An Aperio ScanScope® scanner was used to digitalize histological slides used in practical lectures of oral pathology. The challenges and benefits observed by the group of Professors from the Piracicaba Dental School (Brazil) are described and a questionnaire to evaluate the students' compliance to this new methodology was applied. An improvement in the classes was described by the Professors who mainly dealt with questions related to pathological changes instead of technical problems; also, a higher interaction with the students was described. The simplicity of the software used and the high quality of the virtual slides, requiring a smaller time to identify microscopic structures, were considered important for a better teaching process. Virtual microscopy used to teach oral pathology represents a useful educational methodology, with an excellent compliance of the dental students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Friction coefficient (FC) was quantified between titanium-titanium (Ti-Ti) and titanium-zirconia (Ti-Zr), materials commonly used as abutment and implants, in the presence of a multispecies biofilm (Bf) or salivary pellicle (Pel). Furthermore, FC was used as a parameter to evaluate the biomechanical behavior of a single implant-supported restoration. Interface between Ti-Ti and Ti-Zr without Pel or Bf was used as control (Ctrl). FC was recorded using tribometer and analyzed by two-way Anova and Tukey test (p<0.05). Data were transposed to a finite element model of a dental implant-supported restoration. Models were obtained varying abutment material (Ti and Zr) and FCs recorded (Bf, Pel, and Ctrl). Maximum and shear stress were calculated for bone and equivalent von Misses for prosthetic components. Data were analyzed using two-way ANOVA (p<0.05) and percentage of contribution for each condition (material and FC) was calculated. FC significant differences were observed between Ti-Ti and Ti-Zr for Ctrl and Bf groups, with lower values for Ti-Zr (p<0.05). Within each material group, Ti-Ti differed between all treatments (p<0.05) and for Ti-Zr, only Pel showed higher values compared with Ctrl and Bf (p<0.05). FC contributed to 89.83% (p<0.05) of the stress in the screw, decreasing the stress when the FC was lower. FC resulted in an increase of 59.78% of maximum stress in cortical bone (p=0.05). It can be concluded that the shift of the FC due to the presence of Pel or Bf is able to jeopardize the biomechanical behavior of a single implant-supported restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the reasons for missed appointments in dental Family Health Units (FHU) and implement strategies to reduce same through action research. This is a study conducted in 12 FHUs in Piracicaba in the State of São Paulo from January, 1 to December, 31 2010. The sample was composed of 385 users of these health units who were interviewed over the phone and asked about the reasons for missing dental appointments, as well as 12 dentists and 12 nurses. Two workshops were staged with professionals: the first to assess the data collected in interviews and develop strategy, and the second for evaluation after 4 months. The primary cause for missed appointments was the opening hours of the units coinciding with the work schedule of the users. Among the strategies suggested were lectures on oral health, ongoing education in team meetings, training of Community Health Agents, participation in therapeutic groups and partnerships between Oral Health Teams and the social infrastructure of the community. The adoption of the single medical record was the strategy proposed by professionals. The strategies implemented led to a 66.6% reduction in missed appointments by the units and the motivating nature of the workshops elicited critical reflection to redirect health practices.