997 resultados para Complete test suites


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An alternative to the Stroop Color-Word Test (SCWT), denominated the Colored Numbers Test (CNT), was developed to evaluate the selective attention of illiterate individuals. A total of 30 volunteers with basic education (control group) and 30 illiterate volunteers (experimental group) performed the SCWT and the CNT. Volunteers had to name the color of the rectangles in the CNT neutral condition, and in the critical condition they had to either name the color of the numbers or, when the numbers were black, read the numbers. An interference index (II) was calculated for both tests by subtracting the time taken to complete the task in the neutral condition from the time taken to complete the task in the critical condition. The control group showed an II of 14.9s in the SCWT and of 19.1s in the CNT, and the experimental group, which practically presented no interference in the SCWT (II = 0.2s), showed an II of 18.7s in the CNT. These findings suggest that the CNT can he used to evaluate selective attention. Further work should confirm its validity. Its advantage over the SCWT is that it does not depend on the ability to read words, being then suitable for illiterate individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Användandet av mobila applikationer har växt radikalt de senaste åren och de samverkar med många system. Därför ställs det högre krav på kvaliteten och att applikationen ska anpassas till många olika enheter, operativsystem samt plattformar. Detta gör att test av mobila applikationer blivit viktigare och större. Detta arbete har bedrivits som en jämförande fallstudie inom området test av mobila applikationer samt testverktyg. Syftet har varit att beskriva hur testning av mobila applikationer sker idag vilket gjorts genom litteraturstudier och intervjuer med IT-företag. Ett annat syfte har varit att utvärdera fyra testverktyg, deras för- och nackdelar samt hur de kan användas vid testning av mobila applikationer och jämföras mot manuell testning utan testverktyg. Detta har gjorts genom att skapa förstahandserfarenheter baserat på användandet av testverktygen. Under arbetet har vi utgått från mobila applikationer som vi fått tillgång till av Triona, som varit vår samarbetspartner.Idag finns många olika testverktyg som kan användas som stöd för testningen men få företag har implementerat något eftersom det kräver både tid och kompetens samt valet av testverktyg kan vara svårt. Testverktygen har olika för- och nackdelar vilket gör att de passar olika bra beroende på typ av projekt och applikation. Fördelar med att använda testverktyg är möjligheten att kunna automatisera, testa på flera enheter samtidigt samt få tillgång till enheter via molnet. Utmaningarna är att det kan vara svårt att installera och lära sig testverktyget samt att licenserna kan vara dyra. Det är därför viktigt att redan innan implementationen veta vilka tester och applikationer testverktygen ska användas till samt vem som ska använda det. Utifrån vår studie kan slutsatsen dras att inget testverktyg är helt komplett men de kan bidra med olika funktioner vilket effektiviserar delar av testningen av mobila applikationer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes:  • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results.   The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are:  • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions.   The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab.   This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate and correlate quality of life (QoL), and stimulus perception of complete denture users, before and after the insertion of new prostheses. We selected 60 patients using bimaxillary complete conventional dentures who needed to replace their prostheses. During anamnesis, we collected demographic data and applied the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT) questionnaire and stimulus perception questionnaire (PERCEPTION). Before installation of new prostheses, the patients responded to OHIP-EDENT questionnaire, and on the day of installation, they responded to PERCEPTION questionnaire. At the patients 3-month follow-up, we re-administered the OHIP-EDENT and PERCEPTION questionnaires. The Wilcoxon and MacNemar tests were used to compare patient responses between the time points analysed. Most of the OHIP-EDENT items showed a highly significant impact of the new prostheses on oral health (P = 0.003). The PERCEPTION questionnaire data indicated that the patients experienced significant improvements (P < 0.05) in terms of their sensations with the new prostheses. Cross-lagged data analysis did not show any causality between the OHIP-EDENT and PERCEPTION questionnaires (ZPF test, P = 0.772). We concluded that the treatment was effective with respect to the patients QoL and their adaptation to the new prostheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to compare the artificial tooth positional changes following the flasking and polymerization of complete dentures by a combination of two flasking methods and two polymerization techniques using computer graphic measurements.Materials and Methods: Four groups of waxed complete dentures (n = 10) were invested and polymerized using the following techniques: (1) adding a second investment layer of gypsum and conventional water bath polymerization (Control), (2) adding a second investment layer of gypsum and polymerization with microwave energy (Gyp-micro), (3) adding a second investment layer of silicone (Zetalabor) and conventional polymerization (Silwater), and (4) adding a second investment layer of silicone and polymerization with microwave energy (Silmicro). For each specimen, six segments of interdental distances (A to F) were measured to determine the artificial tooth positions in the waxed and polymerized stages using software program AutoCad R14. The mean values of the changes were statistically compared by univariate ANOVA with Tukey post-hoc test at 5% significance.Results: There were no significant differences among the four groups, except for segment D of the Silmicro group (-0.004 +/- 0.032 cm) in relation to the Gypwater group (0.044 +/- 0.031 cm) (p < 0.05), which presented, repectively, expansion and shrinkage after polymerization.Conclusions: Within the limitations of this study, it was concluded that although the differences were not statistically significant, the use of a silicone investment layer when flasking complete dentures resulted in the least positional changes of the artificial teeth regardless of the polymerization technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. An increase in occlusal vertical dimension (OVD) may occur after processing complete dentures. Although many factors that generate this change are known, no information is available in the dental literature regarding the effect that the occlusal scheme may have on the change in OVD.Purpose. This in vitro study compared the increase in OVD, after processing, between complete dentures with teeth arranged in lingualized balanced occlusion and conventional balanced occlusion.Material and methods. Thirty sets of complete dentures were evaluated as follows: 15 sets of complete dentures were arranged in conventional balanced occlusion (control) and 15 sets of complete dentures were arranged in lingualized balanced occlusion. All dentures were compression molded with a long polymerization cycle. The occlusal vertical dimension was measured with a micrometer (mm) before and after processing each set of dentures. Data were analyzed using an independent t test (alpha=.05).Results. The mean increase in the OVD, after processing, was 0.87 +/- 0.21 mm for the control group and 0.90 +/- 0.27 mm for the experimental group. There was no significant difference between the groups.Conclusion. After processing, dentures set in lingualized balanced occlusion showed an increase in OVD similar to those set in conventional balanced occlusion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)