999 resultados para Canal de empréstimos bancários
Resumo:
The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).
Resumo:
Neste artigo, investiga-se a adoção de canais alternativos para a comercialização de produtos agrícolas como forma de atenuar o poder, cada vez maior, exercido pelas grandes redes varejistas. O artigo investiga a decisão - e os efeitos daí decorrentes - de uma determinada empresa sediada no interior paulista, agrícola Pedra Branca, quanto à operacionalização verticalizada de uma butique de frutas, legumes e verduras (FLVs). Consciente dos novos padrões demandados pelo consumidor, a estratégia da empresa alvo do estudo foi combinar a oferta regular de produtos frescos, de qualidade intrínseca padronizada e preços atrativos, a um serviço diferenciado, baseado em um alto valor na experiência de compra. Esta estratégia fundamenta-se no anseio dos consumidores de, mais do que simplesmente adquirir produtos, experimentar sensações, as quais vividas em momentos de lazer exerceriam um grande poder de diferenciação. Realizou-se um estudo de caso baseado em entrevistas em profundidade semiestruturadas com diretores e gerentes da empresa. Como resultado, as evidências empíricas sugerem: 1) a verticalização (integração vertical) da atividade de comercialização como uma alternativa para a apropriação de valor da produção ao longo do canal de distribuição; e 2) o desafio da gestão do suprimento como requisito-chave para a adequada gestão do valor de uma marca. Considera-se oportuno lembrar, porém, que, em decorrência das limitações próprias da metodologia de estudos de caso, estas tais evidências devem ser entendidas como proposição a ser testada em trabalhos quantitativos futuros, ou mesmo melhor embasada via condução de estudos multicaso.
Resumo:
Objective: The aim of this study was to evaluate the morphology and permeability of root canal walls irradiated with Er,Cr:YSGG laser after conventional endodontic treatment. Background: Laser irradiation can be used for dentinal tubule exposure, smear layer removal, and disinfection. Another potential, interesting application is as an adjunct to endodontic treatment, especially in the intracanal medication phase. Methods: Fifty-two single-rooted teeth had their crowns sectioned at the cementoenamel junction and were randomly divided into four groups (n = 13): G1: conventional preparation (CP) + irrigation with EDTA-T+rhodamine B dye solution associated with NDP (dexamethasone phosphate, paramonochlorophenol, polyethylenoglycol) (Rhod-NDP); G2: CP+EDTA-T + Er,Cr:YSGG laser irradiation 0.75W+Rhod-NDP; G3: CP + EDTA-T + Er,Cr:YSGG 1.5W+Rhod-NDP; G4: CP + EDTA-T + Er,Cr:YSGG 2.5W + Rhod-NDP. For the permeability analysis (n = 9), teeth were transversely cut and two slices of each third were selected. The images were analyzed by ImageLab software (Softium Informatica Ltda., Sao Paulo, SP, Brazil). Additional samples (n = 4) were examined by scanning electron microscopy. Results: Data were analyzed statistically using the Kruskal-Wallis and Student-Newman-Keuls tests for the following areas: apical third (H = 23.4651): G1 (14.25)(a), G2 (17.66)(ab), G3 (26.50)(b), G4 (39.58)(c); medium (H = 23.1611): G1 (14.16)(a), G2 (16.66)(ab), G3 (28.83)(b), G4 (38.33)(b); and cervical (H = 32.4810): G1 (9.66)(a), G2 (20.00)(ab), G3 (27.00)(b), G4 (41.33)(c), (p<0.01). Despite the irregular aspect of laser irradiation along the canal walls, the parameters of 1.5W and 2.5W allowed morphologic modifications that increased dentinal permeability. Conclusions: Irradiation with Er, Cr: YSGG laser could be effective in endodontic treatment for increasing dentinal permeability.
Resumo:
Objective: The purpose of this in vitro study was to investigate using the scanning electron microscope (SEM) the ultrastructural morphological changes of the radicular dentine surface after irradiation with 980-nm diode laser energy at different parameters and angles of incidence. Background Data: There have been limited reports on the effects of diode laser irradiation at 980 nm on radicular dentin morphology. Materials and Methods: Seventy-two maxillary canines were sectioned and roots were biomechanically prepared using K3 rotary instruments. The teeth were irrigated with 2 mL of distilled water between files and final irrigation was performed with 10 mL of distilled water. The teeth were then randomly divided into five groups (n = 8 each) according to their diode laser parameters: Group 1: no irradiation (control); group 2: 1.5 W/continuous wave (CW) emission (the manufacturer's parameters); group 3: 1.5 W/100 Hz; group 4: 3 W/CW; and group 5: 3 W/100 Hz. Laser energy was applied with helicoid movements (parallel to the canal walls) for 20 sec. Eight additional teeth for each group were endodontically prepared and split longitudinally and irradiation was applied perpendicularly to the root surface. Results: Statistical analysis showed no difference between the root canal thirds irradiated with the 980-nm diode laser, and similar results between the parameters 1.5 W/CW and 3 W/100 Hz (p > 0.05). Conclusion: When considering different output powers and delivery modes our results showed that changes varied from smear layer removal to dentine fusion.
Resumo:
Street elevation.
Resumo:
Street elevation.
Resumo:
Benign Paroxysmal Positional Vertigo is the most common peripheral vestibular disorder, especially in the elderly and presents as the predominant etiology in this population of the degeneration of the utricular macula. Aim: To compare the effectiveness of the approaches after Epley maneuver. Study Design: longitudinal cohort. Materials and Methods: The study included 53 volunteers with Benign Paroxysmal Positional Vertigo of the posterior semicircular canal, divided into Group 1, who underwent Epley maneuver associated with the use of neck collar and post-maneuver instructions, Group 2 underwent the Epley maneuver without the use cervical collar and/or post-maneuver restrictions, and Group 3 underwent the Epley maneuver associated with the use of a mini vibrator, without the use of neck collar and/or post-maneuver restrictions. Results: In the three groups, the number of Epley maneuvers ranged from one to three. We employed the Brazilian Dizziness Handicap Inventory - pre- and post-treatment and observed a statistically significant difference on most scores pre- and post-treatment for both groups. Conclusion: Regardless of the post Epley maneuver treatment selected for the treatment of Benign Paroxysmal Positional Vertigo, it was effective when comparing the Brazilian Dizziness Handicap Inventory pre- and post-treatment.
Resumo:
For some surgical procedures in veterinary dentistry including exodontia, orthognathic surgery, orthopedic surgery, oncologic surgery, and for the placement of dental implants, it is important to know the accurate location of the neurovascular structures within the mandibular canal. The aim of this research was to determine the course of the mandibular canal in the mandible and its relationship with other anatomical structures in brachycephalic dogs using computerized tomography. Mandibles from 10 brachycephalic cadaver dogs were evaluated. Measurements were taken in relation to the lingual, vestibular alveolar crest, and ventral surfaces. These measurements indicated that the mandibular canal descends slightly from the mandibular foramen to the molar area, decreasing the distance of the mandibular canal from the mandibular ventral border The mandibular canal is slightly closer to the lingual surface than the vestibular surface except in the molar tooth region. The mandibular canal continues in a rostral direction occupying the ventral region of the mandibular body, reaching its maximum distance from the alveolar crest at the level of the first molar and fourth premolar teeth. In the third and fourth premolar tooth region, the mandibular canal maintains a similar distance between the vestibular and lingual borders; then, at the level of the second premolar tooth, the distance of the mandibular canal from the lingual and ventral border increases before its termination at the mental, foramen. The study reported here documents the feasibility of using CT to determine the location of the mandibular canal in relation to bony and dental parameters. Although the difference in mandible size of the group of brachycephalic dogs reported here resulted in broad ranges of measurements, it is clear that the MC course may vary between individual dogs. J Vet Dent 26(3); 156 - 163, 2009
Resumo:
This study aimed to test the hypothesis that dentine alterations induced by 810 nm-diode laser may affect the interaction between root canal sealers and the dentin wall. Seventy-two single root human teeth were selected and root canals were enlarged with K-files. Dentine was treated with 0.5% NaOCl and 17% EDTA-T and irradiated (laser group) by diode laser (810 nm/P = 2.5W/I = 1989 W/cm(2)) or remained non-irradiated (control group). Six samples per group were analyzed by scanning electron microscopy (SEM). The remaining samples of each group were divided into three subgroups (n = 10) and sealed with one of the tested sealers (N-Rickert/AHPlus (TM)/Apexit (R)). Apical leakage was estimated by evaluating penetration of 0.5% methylene-blue dye. SEM analysis revealed that dentine at the apical third in irradiated samples was melted and fusioned whereas non-irradiated samples exhibited opened dentinal tubules. Despite the morphological changes induced by irradiation, laser did not affect the sealing ability of N-Rickert and AHPlus (TM) sealers. However, the length of apical leakage in roots filled with Apexit (R) was lower in irradiated root canals than in non-irradiated samples (p < 0.05). Morphological changes of root canal walls promoted by diode laser irradiation may improve de sealing ability of Apexit (R), a calcium hydroxide-based sealer, suggesting that improved sealing promoted by irradiation may represent an additional factor contributing to the endodontic clinical outcome.
Resumo:
The aim of this study was to compare the effects of Nd:YAG, Er:YAG, and diode lasers on the morphology and permeability of root canal walls. The three laser wavelengths mentioned interact differently with dentin and therefore it is possible that the permeability changes caused will determine different indications during endodontic treatment. Twenty-eight human single-rooted teeth were instrumented up to ISO 40 and divided into four groups: group C, control (GC), non-laser irradiated; group N (GN), irradiated with Nd:YAG laser; group E (GE), with Er:YAG laser and group D (GD) with diode laser. After that, the roots were filled with a 2% methylene blue dye, divided into two halves and then photographed. The images were analyzed using Image J software and the percentage of dye penetration in the cervical, middle, and apical root thirds were calculated. Additional scanning electron microscopy (SEM) analyses were also performed. The analysis of variance (ANOVA) showed significant permeability differences between all groups in the middle and cervical thirds (p < 0.05). The Tukey test showed that in the cervical third, GN presented means of dye penetration statistically significantly lower than all of the other groups. In the middle third, GE and GD showed statistically higher dye penetration means than GC and GN. SEM analysis showed melted surfaces for GN, clean wall surfaces with open dentinal tubules for GE, and mostly obliterated dentinal tubules for GD. Er:YAG (2,094 nm) laser and diode laser (808 nm) root canal irradiation increase dentinal permeability and Nd:YAG (1,064 nm) laser decreases dentin permeability, within the studied parameters.
Resumo:
Introduction: An experimental mineral trioxide aggregate sealer (MTAS) has been developed for use as a root canal sealer. The aim of this study was to evaluate the setting time, pH, and calcium ion release of MTAS compared with white Portland cement (CPB-40; Votorantin Cimentos, Camargo Correa SA, Pedro Leopoldo, MG, Brazil), white MTA Angelus (MTA; Angelus, Londrina, PR, Brazil), and AH Plus (Dentsply DeTrey, Konstanz, Germany). Methods: For the evaluation of setting time, each material was analyzed using Gilmore-type needles. Polyethylene tubes with the materials were immersed in distilled water for the measurement of pH (digital pH meter) and calcium release (atomic absorption spectrophotometry). The evaluations were performed at 3, 6, 12, 24, and 48 hours and 7, 14, and 28 days. Data were analyzed by analysis of variance and the Tukey test at 5% significance level. Results: MTAS showed higher calcium release at all experimental periods, a greater increase in pH up to 48 hours and the longest setting time. Conclusions: MTAS presented favorable properties for its indication as a root canal sealer. (J Endod 2011;37:844-846)
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)
Resumo:
Objective. The aim of this study was to compare Profile .04 taper series 29 instruments and hand files for gutta-percha removal. Study design. Twenty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 2 groups of 10 specimens each, according to gutta-percha removal techniques: Group 1- Profile series 29 and Group 2- hand files and solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken and the teeth were grooved longitudinally and split. The area of residual debris was measured using computer software. Results. The time for filling material removal was significantly shorter when Profile series 29 was used (P = .00). Regarding cleanliness, there were no statistical differences in the teeth halves evaluations (P = .05). Hand instruments cleaned the canals significantly better than Profiles, in the radiographic analysis considering the whole canal. Overall, the radiographic analysis showed a smaller percentage of residual debris than the teeth halves analysis. Conclusion. The Profile series 29 instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments yielded better root canal cleanliness. Some residual debris was not visualized by radiographs. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e46-e50)