957 resultados para Breath-hold Divers
Resumo:
Background Random Breath Testing (RBT) has proven to be a cornerstone of enforcement attempts to deter (as well as apprehend) motorists from drink driving in Queensland (Australia) for decades. However, scant published research has examined the relationship between the frequency of implementing RBT activities and subsequent drink driving apprehension rates across time. Aim This study aimed to examine the prevalence of apprehending drink drivers in Queensland over a 12 year period. It was hypothesised that an increase in breath testing rates would result in a corresponding decrease in the frequency of drink driving apprehension rates over time, which would reflect general deterrent effects. Method The Queensland Police Service provided RBT data that was analysed. Results Between the 1st of January 2000 and 31st of December 2011, 35,082,386 random breath tests (both mobile and stationary) were conducted in Queensland, resulting in 248,173 individuals being apprehended for drink driving offences. A total of 342,801 offences were recorded during this period, representing an intercept rate of .96. Of these offences, 276,711 (80.72%) were recorded against males and 66,024 (19.28%) offences committed by females. The most common drink driving offence was between 0.05 and 0.08 BAC limit. The largest proportion of offences was detected on the weekends, with Saturdays (27.60%) proving to be the most common drink driving night followed by Sundays (21.41%). The prevalence of drink driving detection rates rose steadily across time, peaking in 2008 and 2009, before slightly declining. This decline was observed across all Queensland regions and any increase in annual figures was due to new offence types being developed. Discussion This paper will further outline the major findings of the study in regards to tailoring RBT operations to increase detection rates as well as improve the general deterrent effect of the initiative.
Resumo:
As Himalayan glaciers melt, the natural dams formed beneath them become a dangerous threat to villages below. However, local yak farmers could soon have a simple solution.
Resumo:
• In December 1986 funds were approved to double the intensity of random breath testing (RBT) and provide publicity support for police efforts. These changes were considered necessary to make RBT effective. • RBT methods were changed in the metropolitan area to enable block testing (pulling over a block of traffic rather than one or two cars), deployment of police to cut off escape routes, and testing by traffic patrols in all police subdivisions. Additional operators were trained for country RBT. • A publicity campaign was developed, aimed mainly at male drivers aged 18-50. The campaign consisted of the “cardsharp” television commercials, radio commercials, newspaper articles, posters and pamphlets. • Increased testing and the publicity campaigns were launched on 10 April 1987. • Police tests increased by 92.5% in May – December 1987, compared with the same period in the previous four years. • The detection rate for drinking drivers picked up by police who were cutting off escape routes was comparatively high, indicating that drivers were attempting to avoid RBT, and that this police method was effective at detecting these drivers. • A telephone survey indicated that drivers were aware of the messages of the publicity campaign. • The telephone survey also indicated that the target group had been exposed to high levels of RBT, as planned, and that fear of apprehension was the major factor deterring them from drink driving. • A roadside survey of driver blood alcohol concentrations (BACs) by the University of Adelaide’s Road Accident Research Unit (RARU) showed that, between 10p.m. and 3a.m., the proportion of drivers in Adelaide with a BAC greater than or equal to 0/08 decreased by 42%. • Drivers under 21 were identified as a possible problem area. • Fatalities in the twelve month period commencing May 1987 decreased by 18% in comparison with the previous twelve month period, and by 13% in comparison with the average of the previous two twelve month periods (commencing May 1985 and May 1986). There are indications that this trend is continuing. • It is concluded that the increase in RBT, plus publicity, was successful in achieving its aims of reductions in drink driving and accidents.
Resumo:
Random breath testing (RBT) was introduced in South Australia in 1981 with the intention of reducing the incidence of accidents involving alcohol. In April 1985, a Select Committee of the Upper House which had been established to “review the operation of random breath testing in this State and any other associated matters and report accordingly” presented its report. After consideration of this report, the Government introduced extensive amendments to those sections of the Motor Vehicles Act (MVA) and Road Traffic Act (RTA) which deal with RBT and drink driving penalties. The amended section 47da of the RTA requires that: “(5) The Minister shall cause a report to be prepared within three months after the end of each calendar year on the operation and effectiveness of this section and related sections during that calendar year. (6) The Minister shall, within 12 sitting days after receipt of a report under subsection (5), cause copies of the report to be laid before each House of Parliament.” This is the first such report. Whilst it deals with RBT over a full year, the changed procedures and improved flexibility allowed by the revision to the RTA were only introduced late in 1985 and then only to the extent that the existing resources would allow.
Resumo:
Years of buy-outs, takeovers, mergers and rebranding have whittled a once plentiful landscape of department store competitors down to two major players, Myer and David Jones. Now, despite David Jones confirming it refused a potential A$3 billion merger proposal approach from its arch-competitor in October 2013, we must face the distinct possibility of there only being room for one, full line, up-market department store in Australia.
Resumo:
Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.
Resumo:
In this paper, the design and development of a novel low-cost, non-invasive type sensor suitable for human breath sensing is reported. It can be used to detect respiratory disorders like bronchial asthma by analyzing the recorded breathing pattern. Though there are devices like spirometer to diagnose asthma, they are very inconvenient for patient's use because patients are made to exhale air through mouth forcefully. Presently developed sensor will overcome this limitation and is helpful in the diagnosis of respiratory related abnormalities. Polyvinylidene fluoride (PVDF) film in cantilever configuration is used as a sensing element to form the breath sensor. Two identical sensors are mounted on a spectacle frame, such that the tidal flow of inhaled and exhale air will impinge on sensor, for sensing the breathing patterns. These patterns are recorded, filtered, analyzed and displayed using CRO. Further the sensor is calibrated using a U-tube water manometer. The added advantage of piezoelectric type sensing element is that it is self powered without the need of any external power source.
Resumo:
The sparse recovery methods utilize the l(p)-normbased regularization in the estimation problem with 0 <= p <= 1. These methods have a better utility when the number of independent measurements are limited in nature, which is a typical case for diffuse optical tomographic image reconstruction problem. These sparse recovery methods, along with an approximation to utilize the l(0)-norm, have been deployed for the reconstruction of diffuse optical images. Their performancewas compared systematically using both numerical and gelatin phantom cases to show that these methods hold promise in improving the reconstructed image quality.
Resumo:
Joan Nieuhoff, viajante alemão, nasceu em Usen, Vesfália, em 1618, e morreu em Madagascar, em 1672. Trabalhou na Companhia das Índias Orientais, foi nomeado agente em Batávia, em 1654. Em 1655, foi à China tratar da abertura dos portos daquele país ao comércio holandês. Governou o Ceilão de 1662 a 1667. Em 1672, desembarcando em Madagascar, foi morto pelos nativos.
Resumo:
A new method of frequency-shifting for a diode laser is realized. Using a sample-and-hold circuit, the error signal can be held by the circuit during frequency shifting. It can avoid the restraint of locking or even lock-losing caused by the servo circuit when we input a step-up voltage into piezoelectric transition (PZT) to achieve laser frequency-shifting.
Resumo:
The method developed by Robson (1966) is used to standardize fishing effort of Côte d'Ivoire trawlers whose size and power are very different. This method also allows the estimation of the relative abundances in the different fishing areas. The results obtained using 10 years data show that the entire Ivorian continental shelf can be considered as a single fishery unit. The relative fishing power of vessels is well correlated with gross tonnage, brake horse power and length of the vessel. The obsolescence of the trawlers affects their fishing power.