988 resultados para BAROREFLEX CARDIAC COMPONENT
Resumo:
To investigate the physiological roles of gp130 in detail and to determine the pathological consequence of abnormal activation of gp130, transgenic mice having continuously activated gp130 were created. This was carried out by mating mice from interleukin 6 (IL-6) and IL-6 receptor (IL-6R) transgenic lines. Offspring overexpressing both IL-6 and IL-6R showed constitutive tyrosine phosphorylation of gp130 and a downstream signaling molecule, acute phase response factor/signal transducer and activator of transcription 3. Surprisingly, the distinguishing feature of such offspring was hypertrophy of ventricular myocardium and consequent thickened ventricular walls of the heart, where gp130 is also expressed, in adulthood. Transgenic mice overexpressing either IL-6 or IL-6R alone did not show detectable myocardial abnormalities. Neonatal heart muscle cells from normal mice, when cultured in vitro, enlarged in response to a combination of IL-6 and a soluble form of IL-6R. The results suggest that activation of the gp130 signaling pathways leads to cardiac hypertrophy and that these signals might be involved in physiological regulation of myocardium.
Resumo:
Rise time and duration are two parametric characteristics of the eliciting stimulus frequently used to differentiate among psychophysiological reflexes. The present research varied the duration (study 1) and rise time (study 2) of an intense acoustic stimulus to dissociate cardiac defense and cardiac startle using the eyeblink response as the external criterion of startle. In each study, 100 participants were presented with five white noise stimuli of 105 dB under one of five duration (50, 100, 250, 500, and 1000 ms) or rise time (0, 24, 48, 96, and 240 ms) conditions. Cardiac defense was affected by stimulus duration, present only in the 500- and 1000-ms conditions, but not by stimulus rise time, present in all rise time conditions. Rise time affected blink startle, but did not selectively alter the short latency accelerative component of the heart rate response, thus questioning whether it reflects startle.
Resumo:
The objective of this study was to investigate the nature and biomechanical properties of collagen fibers within the human myocardium. Targeting cardiac interstitial abnormalities will likely become a major focus of future preventative strategies with regard to the management of cardiac dysfunction. Current knowledge regarding the component structures of myocardial collagen networks is limited, further delineation of which will require application of more innovative technologies. We applied a novel methodology involving combined confocal laser scanning and atomic force microscopy to investigate myocardial collagen within ex-vivo right atrial tissue from 10 patients undergoing elective coronary bypass surgery. Immuno-fluorescent co-staining revealed discrete collagen I and III fibers. During single fiber deformation, overall median values of stiffness recorded in collagen III were 37±16% lower than in collagen I [p<0.001]. On fiber retraction, collagen I exhibited greater degrees of elastic recoil [p<0.001; relative percentage increase in elastic recoil 7±3%] and less energy dissipation than collagen III [p<0.001; relative percentage increase in work recovered 7±2%]. In atrial biopsies taken from patients in permanent atrial fibrillation (n=5) versus sinus rhythm (n=5), stiffness of both collagen fiber subtypes was augmented (p<0.008). Myocardial fibrillar collagen fibers organize in a discrete manner and possess distinct biomechanical differences; specifically, collagen I fibers exhibit relatively higher stiffness, contrasting with higher susceptibility to plastic deformation and less energy efficiency on deformation with collagen III fibers. Augmented stiffness of both collagen fiber subtypes in tissue samples from patients with atrial fibrillation compared to those in sinus rhythm are consistent with recent published findings of increased collagen cross-linking in this setting.
Resumo:
Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.