995 resultados para Antigen 5
Resumo:
Two groups of patients undergoing hemodialysis (HD) maintenance were evaluated for their antibody response to non-structural c100/3 protein and structural core protein of hepatitis C virus (HCV). Forty-six patients (Group 1) never presented liver abnormalities during HD treatment, while 52 patients (Group 2) had either current or prior liver enzyme elevations. Prevalence rates of 32.6% and 41.3% were found for anti-c100/3 and anti-HCV core antibodies, respectively, in patients with silent infections (Group 1). The rate of anti-c100/3 in patients of Group 2 was 71.15% and reached 86.5% for anti-HCV core antibodies. The recognition of anti-c100/3 and anti-core antibodies was significantly higher in Group 2 than in Group 1. A line immunoassay composed of structural and non-structural peptides was used as a confirmation assay. HBV infection, measured by the presence of anti-HBc antibodies, was observed in 39.8% of the patients. Six were HBsAg chronic carriers and 13 had naturally acquired anti-HBs antibodies. The duration of HD treatment was correlated with anti-HCV positivity. A high prevalence of 96.7% (Group 2) was found in patients who underwent more than 5 years of treatment. Our results suggest that anti-HCV core ELISA is more accurate for detecting HCV infection than anti-c100/3. Although the risk associated with the duration of HD treatment and blood transfusion was high, additional factors such as a significant non-transfusional spread of HCV seems to play a role as well. The identification of infective patients by more sensitive methods for HCV genome detection should help to control the transmission of HCV in the unit under study.
Resumo:
Leishmania braziliensis is a causative agent of American Cutaneous Leishmaniasis (ACL). The 034-JCG strain, isolated from a patient from the northern region of Paraná State, Brazil, was cultivated in Blood Agar Base medium, lyophilized and submitted to phenol-water extraction. The extract was treated with RNase I. The carbohydrate containing-antigen (Ag-CHO) was immunogenic to rabbits and showed at least a fraction with some negative charge at pH 8.2. This antigen showed cross-reactivity with the phenol-water extract of the growth medium used for the culture of promastigotes and with the surface antigens of promastigotes. Its composition is: 24.3% of total sugars, from which 11.2% of galactose, 7.5% of mannose and 5.6% of ribose. Protein content was 5.4% and phosphate 18.5%. The antigenic activity was maintained after: repeated freezing-thawing; lyophilization; heating at 100ºC for 30 minutes; treatment with RNase, trichloroacetic acid and sodium metaperiodate. The precipitin line obtained is Periodic Acid Schiff positive. The application of the Ag-CHO in counterimmunoelectrophoresis reaction for the immunodiagnosis of ACL showed 60% sensitivity, and no cross-reaction with the five sera of Chagas' disease patients tested. The use of this antigen in a more sensitive technique, with more samples of sera, may improve these results.
Resumo:
Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.
Resumo:
This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen
Resumo:
Cryo-microtome sections of larvae of Strongyloides stercoralis and S. ratti respectively obtained from human and rat feces cultures, were used as antigens. Fluoresceinate conjugates against human IgG were employed at the ideal titer of 10 for S. stercoralis and 100 for S. ratti. The sensitivity of the indirect immunofluorescence reaction (IIF) was 94.4% and 92.5% and the specificity 94.2% and 97.1% for the two specific larval antigens, respectively. Sera from 123 persons (54 from carriers of S. stercoralis infections and 69 from controls) were submitted to the reaction. The titers of different sera varied from 20 to 2560. There was a significant linear correlation (r = 0.85 p £ 0.001) between the antibodies from the two species of larval antigens. We conclude that both antigens may be used in the IIF reaction for the diagnosis of human strongyloidiasis. Due to the feasibility of safe and low-cost mass production of S. ratti larvae in the laboratory with a considerable economy of conjugate, their utilization in the serum diagnosis of human strongyloidiasis is recommended
Resumo:
Some viruses of the families Retroviridae, such as Human T Lymphotropic Virus (HTLV); Herpesviridae as the Cytomegalovirus (CMV) and Hepadnaviridae such as the Hepatitis B Virus (HBV) are liable to be co-transmitted with the Human Immunodeficiency Virus (HIV). Since prisoners are exposed to several and important risk factors involved in the transmission of HIV and the above mentioned viruses, male inmates from the penitentiary complex of Campinas, SP, Brazil, including HIV + and HIV - ones, were examined for the presence of HTLV-I and/or II antibodies; IgG and IgM anti-CMV antibodies, and the research of the superficial hepatitis B antigen (HBsAg). The presence of anti-HTLV-I and/or II was determined by the Western Blot (WB) technique, whereas IgG and IgM anti-CMV and the search of HBsAg were carried out by the Microparticle Enzyme Immunoassay (MEIA-Abbott Lab).With regard to anti-HTLV-I and/or II, 58.3% (14/24-Number of positive reactions/number of sera examined) were reactive among the anti-HIV positive sera. Conversely, only 12.5% (3/24) among the HIV- negative sera showed positive reactions to HTLV-I and/or II antibodies. When looking for IgG anti-CMV percentages of 97.7% (43/44) and 95% (38/40) were obtained for anti-HIV positive and negative sera, respectively. As to IgM anti-CMV antibodies 11.36% (5/44) and 2.5% (1/40) of reactive sera were found for anti-HIV positive and negative, respectively. The HBsAg was found in 12.8% (5/39) of the sera which were anti-HIV positive.
Resumo:
Four rabies antigen batches were produced from virus suspensions resulting from BHK21 cells adhered to microcarriers (Cytodex 1), inoculated and cultured in a bioreactor. In parallel the methodology of production of rabies virus through cultures of BHK21 cells in monolayers in bottles was used. The results obtained showed that infecting titles were 106.69 DL50/mL and 107.28 DL50/mL for suspensions cultured in bottles and in the bioreactor, respectively. The viral suspension volumes collected were on average 11,900 per batch from the bioreactor and 800mL per bottle. Ten horses were immunized with the antigen produced in the bioreactor. The means of antirabies antibody titers found were 240 and 212 IU/mL after the initial and the first booster doses, respectively. Rabies antigen with satisfactory infecting titers can be obtained on a large scale by culturing in a bioreactor inoculated BHK21 cells adhered to microcarriers.
Resumo:
The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.
Resumo:
This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
Strongyloides ratti larval extract was used for the standardization of ELISA to detect genus-specific IgE in human strongyloidiasis. Forty serum samples from monoinfected patients shedding S. stercoralis larvae (Group I), 40 from patients with other intestinal parasites (Group II), and 40 from copronegative healthy subjects (Group III) were analyzed. Genus-specific IgE levels (ELISA Index: EI) were significantly higher in the group I (EI = 1.43) than groups II (EI = 0.70) and III (EI = 0.71), showing positivity rates of 55%, 2.5% and 0%, respectively. Similarly, sera from copropositive patients had significantly higher levels of total IgE (866 IU/mL) as compared to those from group II (302 IU/mL) and III (143 IU/mL). A significant positive correlation was found between levels of Strongyloides specific-IgE and total IgE in sera from patients with strongyloidiasis. In conclusion, S. ratti heterologous extract showed to be a useful tool for detecting genus-specific IgE by ELISA, contributing for a better characterization of the immune response profile in human strongyloidiasis.
Resumo:
In order to evaluate the potential allergenicity of Blomia tropicalis (Bt) antigen, IgE production of both specific and non-specific for Bt antigen was monitored in BALB/c mice after exposure to the antigen by nasal route. It was evidenced that B. tropicalis contains a functional allergen in its components. The allergenic components, however, when administered intranasally without any adjuvant, did not function to induce IgE response within a short period. On the other hand, intranasal inoculation of Bt antigens augmented serum IgE responses in mice pretreated by a subcutaneous priming injection of the same antigens. Inoculation of Bt antigen without subcutaneous priming injections induced IgE antibody production only when the antigen was continuously administered for a long period of over 24 weeks. Even when the priming injection was absent, the Bt antigen inoculated with cholera toxin (CT) as a mucosal adjuvant also significantly augmented the Bt antigen-specific IgE responses depending on the dose of CT co-administered. The present study also demonstrated that Bt antigen/CT-inoculated mice showed increased non-specific serum IgE level and peripheral blood eosinophil rates without noticeable elevations of the total leukocyte counts. The immunoblot analysis demonstrated 5 main antigenic components reactive to IgE antibodies induced. These components at about 44-64 kDa position were considered to be an important candidate antigen for diagnosis of the mite-related allergy.
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
We evaluated the immunogenicity of three recombinant hepatitis B vaccines, one Brazilian (Butang, Instituto Butantan) and two Korean vaccines (Euvax-B, LG Chemical Ltd. and Hepavax-Gene, Greencross Vaccine Corp.), administered intramuscularly to students aged 17 to 19 years in three 10-µg doses (corresponding to half the amount of antigen routinely used for adult vaccination) at intervals of one month between the first and second dose, and of four months between the second and third dose. A total of 316 students non-reactive for any serological marker of hepatitis B virus infection were vaccinated: 77 (24.4%) with the Butang vaccine, 71 (22.5%) with Euvax-B, 85 (26.9%) with Hepavax-Gene and, for comparison, 83 (26.2%) with Engerix-B (GlaxoSmithKline), whose efficacy in young adults at the dose used here has been confirmed in previous studies. Similar seroconversion rates (anti-HBs > 10 mIU/mL about one month after application of the third dose) were obtained for the Butang, Euvax-B, Hepavax-Gene and Engerix-B vaccines (96.2%, 98.6%, 96.5% and 97.6%, respectively). The frequency of good responders (anti-HBs > 100 mIU/mL) was also similar among students receiving the four vaccines (85.8%, 91.6%, 89.4% and 89.2%, respectively). The geometric mean titers (GMT) of anti-HBs about one month after the third dose obtained with these vaccines were 727.78 ± 6.46 mIU/mL, 2009.09 ± 7.16 mIU/mL, 1729.82 ± 8.85 mIU/mL and 2070.14 ± 11.69 mIU/mL, respectively. The GMT of anti-HBs induced by the Euvax-B and Engerix-B vaccines were higher than those obtained with the Butang vaccine (p < 0.05); this difference was not significant when comparing the other vaccines two-by-two. No spontaneous adverse effects attributable to the application of any dose of the four vaccines were reported.
Resumo:
Toxoplasma gondii causes severe fetal disease during acute infection in pregnant women, thus demanding early diagnosis for effective treatment and fetus preservation. Fetal tests are inefficient and risky, and diagnosis is based on maternal IgM serology, which had weak screening ability due to increased sensitivity, with alternative IgG avidity tests. Here, we performed ELISA and avidity assays using a recombinant T. gondii antigen, rROP2, in samples from 160 pregnant women screened from a large public hospital who were referred due to positive IgM assays. IgG serology and avidity assays were compared using whole T. gondii extract or rROP2. ELISA IgG detection with rROP2 showed good agreement with assays performed with T. gondii extract, but rROP2 IgG avidity assays were unrelated to whole extract antigen IgG avidity, regardless of the chaotrope used. These data show that avidity maturation is specific to individual antigen prevalence and immune response during infection. ELISA rROP2 IgG assays may be an alternative serological test for the diagnosis of toxoplasmosis during pregnancy, although our data do not support their use in avidity assays.