879 resultados para Abdominal discomfort
Resumo:
Forty-three children with recurrent abdominal pain who had received treatment from a paediatric gastroenterology clinic were reassessed 6 and 12 months after initial presentation. Measures of children's pain included a pain diary (PD) which measured pain intensity, a parent observation record (POR) which assessed pain behaviour and a structured interview to assess the degree to which pain interferes with the child's activities. Pretreatment measures of the child's history of pain, coping strategies in dealing with pain, and their mother's caregiving strategies were examined as predictors of two indices of clinical improvement: the extent of change in pain on the child's pain diary from pre-test to 6 months follow-up, and the degree of interference to the child's activities. All children had shown significant improvement in the level of pain at follow up, with 74.4% being pain free at 12 month follow-up on the PD and 83.7% being pain free on the POR. The amount of change they showed varied, with some showing residual impairment even though they were significantly improved. Regression analyses showed that children with greatest reductions on the child's pain diary at the 6 month follow-up were those with a stress-related mode of onset, whose mothers used more adaptive caregiving strategies, and who received cognitive behavioural family intervention. There was also a non significant trend for younger children to fare better. These data suggest the importance of early diagnosis and routinely assessing parental caregiving behaviour and beliefs about the origins of pain in planning treatment for children with RAP.
Resumo:
This study describes the results of a controlled clinical trial involving 44 7- to 14-year-old children with recurrent abdominal pain who were randomly allocated to either cognitive-behavioral family intervention (CBFI) or standard pediatric care (SPC). Both treatment conditions resulted in significant improvements on measures of pain intensity and pain behavior. However, the children receiving CBFI had a higher rate of complete elimination of pain, lower levels of relapse at 6- and 12-month follow-up, and lower levels of interference with their activities as a result of pain and parents reported a higher level of satisfaction with the treatment than children receiving SPC. After controlling for pretreatment levels of pain, children's active self-coping and mothers' caregiving strategies were significant independent predictors of pain behavior at posttreatment.
Resumo:
To help with the clinical screening and diagnosis of abdominal aortic aneurysm (AAA), we evaluated the effect of inflow angle (IA) and outflow bifurcation angle (BA) on the distribution of blood flow and wall shear stress (WSS) in an idealized AAA model. A 2D incompressible Newtonian flow is assumed and the computational simulation is performed using finite volume method. The results showed that the largest WSS often located at the proximal and the distal end of the AAA. An increase in IA resulted in an increase in maximum WSS. We also found that WSS was maximal when BA was 90°. IA and BA are two important geometrical factors, they may help with AAA risk assessment along with the commonly used AAA diameter.
Resumo:
Objective: To compare the differences in the hemodynamic parameters of abdominal aortic aneurysm (AAA) between fluid-structure interaction model (FSIM) and fluid-only model (FM), so as to discuss their application in the research of AAA. Methods: An idealized AAA model was created based on patient-specific AAA data. In FM, the flow, pressure and wall shear stress (WSS) were computed using finite volume method. In FSIM, an Arbitrary Lagrangian-Eulerian algorithm was used to solve the flow in a continuously deforming geometry. The hemodynamic parameters of both models were obtained for discussion. Results: Under the same inlet velocity, there were only two symmetrical vortexes in the AAA dilation area for FSIM. In contrast, four recirculation areas existed in FM; two were main vortexes and the other two were secondary flow, which were located between the main recirculation area and the arterial wall. Six local pressure concentrations occurred in the distal end of AAA and the recirculation area for FM. However, there were only two local pressure concentrations in FSIM. The vortex center of the recirculation area in FSIM was much more close to the distal end of AAA and the area was much larger because of AAA expansion. Four extreme values of WSS existed at the proximal of AAA, the point of boundary layer separation, the point of flow reattachment and the distal end of AAA, respectively, in both FM and FSIM. The maximum wall stress and the largest wall deformation were both located at the proximal and distal end of AAA. Conclusions: The number and center of the recirculation area for both models are different, while the change of vortex is closely associated with the AAA growth. The largest WSS of FSIM is 36% smaller than that of FM. Both the maximum wall stress and largest wall displacement shall increase with the outlet pressure increasing. FSIM needs to be considered for studying the relationship between AAA growth and shear stress.
Resumo:
Background Aneurysm expansion rate is an important indicator of the potential risk of abdominal aortic aneurysm (AAA) rupture. Stress within the AAA wall is also thought to be a trigger for its rupture. However, the association between aneurysm wall stresses and expansion of AAA is unclear. Methods and Results Forty-four patients with AAAs were included in this longitudinal follow-up study. They were assessed by serial abdominal ultrasonography and computed tomography scans if a critical size was reached or a rapid expansion occurred. Patient-specific 3-dimensional AAA geometries were reconstructed from the follow-up computed tomography images. Structural analysis was performed to calculate the wall stresses of the AAA models at both baseline and final visit. A nonlinear large-strain finite element method was used to compute the wall-stress distribution. The relationship between wall stresses and expansion rate was investigated. Slowly and rapidly expanding aneurysms had comparable baseline maximum diameters (median, 4.35 cm [interquartile range, 4.12 to 5.0 cm] versus 4.6 cm [interquartile range, 4.2 to 5.0 cm]; P=0.32). Rapidly expanding AAAs had significantly higher shoulder stresses than slowly expanding AAAs (median, 300 kPa [interquartile range, 280 to 320 kPa] versus 225 kPa [interquartile range, 211 to 249 kPa]; P=0.0001). A good correlation between shoulder stress at baseline and expansion rate was found (r=0.71; P=0.0001). Conclusion A higher shoulder stress was found to have an association with a rapidly expanding AAA. Therefore, it may be useful for estimating the expansion of AAAs and improve risk stratification of patients with AAAs.
Resumo:
Growth rate of abdominal aortic aneurysm (AAA) is thought to be an important indicator of the potential risk of rupture. Wall stress is also thought to be a trigger for its rupture. However, stress change during the expansion of an AAA is unclear. Forty-four patients with AAAs were included in this longitudinal follow-up study. They were assessed by serial abdominal ultrasonography and computerized tomography (CT) scans if a critical size was reached or a rapid expansion occurred. Patient-specific 3-dimensional AAA geometries were reconstructed from the follow-up CT images. Structural analysis was performed to calculate the wall stresses of the AAA models at both baseline and final visit. A non-linear large-strain finite element method was used to compute the wall stress distribution. The average growth rate was 0.66cm/year (range 0-1.32 cm/year). A significantly positive correlation between shoulder tress at baseline and growth rate was found (r=0.342; p=0.02). A higher shoulder stress is associated with a rapidly expanding AAA. Therefore, it may be useful for estimating the growth expansion of AAAs and further risk stratification of patients with AAAs.
Resumo:
Background: Increased biomechanical stresses within the abdominal aortic aneurysm (AAA) wall contribute to its rupture. Calcification and intraluminal thrombus can be commonly found in AAAs, but the relationship between calcification/intraluminal thrombus and AAA wall stress is not completely described. Methods: Patient-specific three-dimensional AAA geometries were reconstructed from computed tomographic images of 20 patients. Structural analysis was performed to calculate the wall stresses of the 20 AAA models and their altered models when calcification or intraluminal thrombus was not considered. A nonlinear large-strain finite element method was used to compute the wall stress distribution. The relationships between wall stresses and volumes of calcification and intraluminal thrombus were sought. Results: Maximum stress was not correlated with the percentage of calcification, and was negatively correlated with the percentage of intraluminal thrombus (r = -0.56; P = .011). Exclusion of calcification from analysis led to a significant decrease in maximum stress by a median of 14% (range, 2%-27%; P < .01). When intraluminal thrombus was eliminated, maximum stress increased significantly by a median of 24% (range, 5%-43%; P < .01). Conclusion: The presence of calcification increases AAA peak wall stress, suggesting that calcification decrease the biomechanical stability of AAA. In contrast, intraluminal thrombus reduces the maximum stress in AAA. Calcification and intraluminal thrombus should both be considered in the evaluation of wall stress for risk assessment of AAA rupture.
Resumo:
Inflammation is a recognized risk factor for the vulnerable atherosclerotic plaque. USPIO-enhanced MRI imaging is a promising non-i nvasive method to identify high-risk atheromatous plaque inflammation in vivo in humans, in which areas of focal signal loss on MR images have been shown to correspond to the location of activated macrophages, typically at the shoulder regions of the plaque. This is the first report in humans describing simultaneous USPIO uptake within atheroma in two different arterial territories and again emphasises that atherosclerosis is a truly systemic disease. With further work, USPIO-enhanced MR imaging may be useful in identifying inflamed vulnerable atheromatous plaques in vivo, so refining patient selection for intervention and allowing appropriate early aggressive pharmacotherapy to prevent plaque rupture.
Resumo:
Physical inactivity, low cardiorespiratory fitness, and abdominal obesity are direct and mediating risk factors for cardiovascular disease (CVD). The results of recent studies suggest that individuals with higher levels of physical activity or cardiorespiratory fitness have lower CVD and all-cause mortality than those with lower activity or fitness levels regardless of their level of obesity. The interrelationships of physical activity, fitness, and abdominal obesity with cardiovascular risk factors have not been studied in detail. The aim of this study was to investigate the associations of different types of leisure time physical activity and aerobic fitness with cardiovascular risk factors in a large population of Finnish adults. In addition, a novel aerobic fitness test was implemented and the distribution of aerobic fitness was explored in men and women across age groups. The interrelationships of physical activity, aerobic fitness and abdominal obesity were examined in relation to cardiovascular risk factors. This study was part of the National FINRISK Study 2002, which monitors cardiovascular risk factors in a Finnish adult population. The sample comprised 13 437 men and women aged 25 to 74 years and was drawn from the Population Register as a stratified random sample according to 10-year age groups, gender and area. A separate physical activity study included 9179 subjects, of whom 5 980 participated (65%) in the study. At the study site, weight, height, waist and hip circumferences, and blood pressure were measured, a blood sample was drawn, and an aerobic fitness test was performed. The fitness test estimated maximal oxygen uptake (VO2max) and was based on a non-exercise method by using a heart rate monitor at rest. Waist-to-hip ratio (WHR) was calculated by dividing waist circumference with hip circumference and was used as a measure of abdominal obesity. Participants filled in a questionnaire on health behavior, a history of diseases, and current health status, and a detailed 12-month leisure time physical activity recall. Based on the recall data, relative energy expenditure was calculated using metabolic equivalents, and physical activity was divided into conditioning, non-conditioning, and commuting physical activity. Participants aged 45 to 74 years were later invited to take part in a 2-hour oral glucose tolerance test with fasting insulin and glucose measurements. Based on the oral glucose tolerance test, undiagnosed impaired glucose tolerance and type 2 diabetes were defined. The estimated aerobic fitness was lower among women and decreased with age. A higher estimated aerobic fitness and a lower WHR were independently associated with lower systolic and diastolic blood pressure, lower total cholesterol and triglyceride levels, and with higher high-density lipoprotein (HDL) cholesterol and HDL to total cholesterol ratio. The associations of the estimated aerobic fitness with diastolic blood pressure, triglycerides, and HDL to total cholesterol ratio were stronger in men with a higher WHR. High levels of conditioning and non-conditioning physical activity were associated with lower high-sensitivity C-reactive protein (CRP) levels. High levels of conditioning and overall physical activities were associated with lower insulin and glucose levels. The associations were stronger among women than men. A better self-rated physical fitness was associated with a higher estimated aerobic fitness, lower CRP levels, and lower insulin and glucose levels in men and women. In each WHR third, the risk of impaired glucose tolerance and type 2 diabetes was higher among physically inactive individuals who did not undertake at least 30 minutes of moderate-intensity physical activity on five days per week. These cross-sectional data show that higher levels of estimated aerobic fitness and regular leisure time physical activity are associated with a favorable cardiovascular risk factor profile and that these associations are present at all levels of abdominal obesity. Most of the associations followed a dose-response manner, suggesting that already low levels of physical activity or fitness are beneficial to health and that larger improvements in risk factor levels may be gained from higher activity and fitness levels. The present findings support the recommendation to engage regularly in leisure time physical activity, to pursue a high level of aerobic fitness, and to prevent abdominal obesity.
Resumo:
The idea of ‘wicked’ problems has made a valuable contribution to recognising the complexity and challenges of contemporary planning. However, some wicked policy problems are further complicated by a significant moral, psychological, religious or cultural dimension. This is particularly the case for problems that possess strong elements of abjection and symbolic pollution and high degrees of psychosocial sensitivity. Because this affects the way these problems are framed and discussed they are also characterised by high levels of verbal proscription. As a result, they are not discussed in the rational and emotion-free way that conventional planning demands and can become obscured or inadequately acknowledged in planning processes. This further contributes to their wickedness and intractability. Through paradigmatic urban planning examples, we argue that placing their unspeakable nature at the forefront of enquiry will enable planners to advocate for a more contextually and culturally situated approach to planning, which accommodates both emotional and embodied talk alongside more technical policy contributions. Re-imagining wicked problems in this way has the potential to enhance policy and plan-making and to disrupt norms, expose their contingency, and open new ways of planning for both the unspeakable and the merely wicked.
Resumo:
Ruptured abdominal aortic aneurysm (RAAA) is a life-threatening event, and without operative treatment the patient will die. The overall mortality can be as high as 80-90%; thus repair of RAAA should be attempted whenever feasible. The quality of life (QoL) has become an increasingly important outcome measure in vascular surgery. Aim of the study was to evaluate outcomes of RAAA and to find out predictors of mortality. In Helsinki and Uusimaa district 626 patients were identified to have RAAA in 1996-2004. Altogether 352 of them were admitted to Helsinki University Central Hospital (HUCH). Based on Finnvasc Registry, 836 RAAA patients underwent repair of RAAA in 1991-1999. The 30-day operative mortality, hospital and population-based mortality were assessed, and the effect of regional centralisation and improving in-hospital quality on the outcome of RAAA. QoL was evaluated by a RAND-36 questionnaire of survivors of RAAA. Quality-adjusted life years (QALYs), which measure length and QoL, were calculated using the EQ-5D index and estimation of life expectancy. The predictors of outcome after RAAA were assessed at admission and 48 hours after repair of RAAA. The 30-day operative mortality rate was 38% in HUCH and 44% nationwide, whereas the hospital mortality was 45% in HUCH. Population-based mortality was 69% in 1996-2004 and 56% in 2003-2004. After organisational changes were undertaken, the mortality decreased significantly at all levels. Among the survivors, the QoL was almost equal when compared with norms of age- and sex-matched controls; only physical functioning was slightly impaired. Successful repair of RAAA gave a mean of 4.1 (0-30.9) QALYs for all RAAA patients, although non-survivors were included. The preoperative Glasgow Aneurysm Score was an independent predictor of 30-day operative mortality after RAAA, and it also predicted the outcome at 48- hours for initial survivors of repair of RAAA. A high Glasgow Aneurysm Score and high age were associated with low numbers of QALYs to be achieved. Organ dysfunction measured by the Sequential Organ Failure Assessment (SOFA) score at 48 hours after repair of RAAA was the strongest predictor of death. In conclusion surgery of RAAA is a life-saving and cost-effective procedure. The centralisation of vascular emergencies improved the outcome of RAAA patients. The survivors had a good QoL after RAAA. Predictive models can be used on individual level only to provide supplementary information for clinical decision-making due to their moderate discriminatory value. These results support an active operation policy, as there is no reliable measure to predict the outcome after RAAA.
Resumo:
The primary aim of this thesis was the evaluation of the perfusion of normal organs in cats using contrast-enhanced ultrasound (CEUS), to serve as a reference for later clinical studies. Little is known of the use of CEUS in cats, especially regarding its safety and the effects of anesthesia on the procedure, thus, secondary aims here were to validate the quantitative analyzing method, to investigate the biological effects of CEUS on feline kidneys, and to assess the effect of anesthesia on splenic perfusion in cats undergoing CEUS. -- The studies were conducted on healthy, young, purpose-bred cats. CEUS of the liver, left kidney, spleen, pancreas, small intestine, and mesenteric lymph nodes was performed to characterize the normal perfusion of these organs on ten anesthetized, male cats. To validate the quantification method, the effects of placement and size of the region of interest (ROI) on perfusion parameters were investigated using CEUS: Three separate sets of ROIs were placed in the kidney cortex, varying in location, size, or depth. The biological effects of CEUS on feline kidneys were estimated by measuring urinary enzymatic activities, analyzing urinary specific gravity, pH, protein, creatinine, albumin, and sediment, and measuring plasma urea and creatinine concentrations before and after CEUS. Finally, the impact of anesthesia on contrast enhancement of the spleen was investigated by imaging cats with CEUS first awake and later under anesthesia on separate days. -- Typical perfusion patterns were found for each of the studied organs. The liver had a gradual and more heterogeneous perfusion pattern due to its dual blood flow and close proximity to the diaphragm. An obvious and statistically significant difference emerged in the perfusion between the kidney cortex and medulla. Enhancement in the spleen was very heterogeneous at the beginning of imaging, indicating focal dissimilarities in perfusion. No significant differences emerged in the perfusion parameters between the pancreas, small intestine, and mesenteric lymph nodes. -- The ROI placement and size were found to have an influence on the quantitative measurements of CEUS. Increasing the depth or the size of the ROI decreased the peak intensity value significantly, suggesting that where and how the ROI is placed does matter in quantitative analyses. --- A significant increase occurred in the urinary N-acetyl-β-D-glucosaminidase (NAG) to creatinine ratio after CEUS. No changes were noted in the serum biochemistry profile after CEUS, with the exception of a small decrease in blood urea concentration. The magnitude of the rise in the NAG/creatinine ratio was, however, less than the circadian variation reported earlier in healthy cats. Thus, the changes observed in the laboratory values after CEUS of the left kidney did not indicate any detrimental effects in kidneys. Heterogeneity of the spleen was observed to be less and time of first contrast appearance earlier in nonanesthetized cats than in anesthetized ones, suggesting that anesthesia increases heterogeneity of the feline spleen in CEUS. ---- In conclusion, the results suggest that CEUS can be used also in feline veterinary patients as an additional diagnostics aid. The perfusion patterns found in the imaged organs were typical and similar to those seen earlier in other species, with the exception of the heterogeneous perfusion pattern in the cat spleen. Differences in the perfusion between organs corresponded with physiology. Based on the results, estimation of focal perfusion defects of the spleen in cats should be performed with caution and after the disappearance of the initial heterogeneity, especially in anesthetized or sedated cats. Finally, these results indicate that CEUS can be used safely to analyze kidney perfusion also in cats. Future clinical studies are needed to evaluate the full potential of CEUS in feline medicine as a tool for diagnosing lesions in various organ systems.