Effect of inflow and outflow angles on the computational hemodynamics in abdominal aortic aneurysm


Autoria(s): Shi, Z.; Li, Z. Y.
Contribuinte(s)

Long, Mian

Data(s)

2013

Resumo

To help with the clinical screening and diagnosis of abdominal aortic aneurysm (AAA), we evaluated the effect of inflow angle (IA) and outflow bifurcation angle (BA) on the distribution of blood flow and wall shear stress (WSS) in an idealized AAA model. A 2D incompressible Newtonian flow is assumed and the computational simulation is performed using finite volume method. The results showed that the largest WSS often located at the proximal and the distal end of the AAA. An increase in IA resulted in an increase in maximum WSS. We also found that WSS was maximal when BA was 90°. IA and BA are two important geometrical factors, they may help with AAA risk assessment along with the commonly used AAA diameter.

Identificador

http://eprints.qut.edu.au/90291/

Publicador

Springer Berlin Heidelberg

Relação

DOI:10.1007/978-3-642-29305-4_42

Shi, Z. & Li, Z. Y. (2013) Effect of inflow and outflow angles on the computational hemodynamics in abdominal aortic aneurysm. In Long, Mian (Ed.) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China, Springer Berlin Heidelberg, Beijing, China, pp. 153-156.

Direitos

Copyright 2013 Springer-Verlag.

Fonte

School of Chemistry, Physics & Mechanical Engineering; Institute of Health and Biomedical Innovation; Science & Engineering Faculty

Palavras-Chave #Abdominal Aortic Aneurysm #Bifurcation Angle #Inflow Angle #Rupture #Wall Shear Stress
Tipo

Conference Paper