860 resultados para ADD-DROP FILTERS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper compares two linear programming (LP) models for shift scheduling in services where homogeneously-skilled employees are available at limited times. Although both models are based on set covering approaches, one explicitly matches employees to shifts, while the other imposes this matching implicitly. Each model is used in three forms—one with complete, another with very limited meal break placement flexibility, and a third without meal breaks—to provide initial schedules to a completion/improvement heuristic. The term completion/improvement heuristic is used to describe a construction/ improvement heuristic operating on a starting schedule. On 80 test problems varying widely in scheduling flexibility, employee staffing requirements, and employee availability characteristics, all six LP-based procedures generated lower cost schedules than a comparison from-scratch construction/improvement heuristic. This heuristic, which perpetually maintains an explicit matching of employees to shifts, consists of three phases which add, drop, and modify shifts. In terms of schedule cost, schedule generation time, and model size, the procedures based on the implicit model performed better, as a group, than those based on the explicit model. The LP model with complete break placement flexibility and implicitly matching employees to shifts generated schedules costing 6.7% less than those developed by the from-scratch heuristic.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the first experimental implementation of an all-optical ROADM scheme for routing of individual channels within an all-optical OFDM superchannel. The interferometric technique demonstrated enables a fully flexible node, implementing the extraction, drop and addition of individual sub-channel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the experimental implementation of an all-optical ROADM scheme for routing of an individual subchannel within an all-optical OFDM superchannel. The different functions required of optical node were demonstrated using interferometric technique with the extraction, drop, and addition of individual subchannel in a ten subchannels optically aggregated signal. The scheme we reported enables a fully flexible node compatible with future terabit per second superchannel transmission.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The experimental implementation of an all-optical node able of routing a channel contained in an all-optical OFDM super-channel is presented. The extract function is performed through channel selection, reshaping and interferometric suppression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Experimental measurements have been made to investigate meaning of the change in voltage for the pulse gas metal arc welding (GMAW-P) process operating under different drop transfer modes. Design/methodology/approach: Welding experiments with different values of pulsing parameter and simultaneous recording of high speed camera pictures and welding signals (such as current and voltage) were used to identify different drop transfer modes in GMAW-P. The investigation is based on the synchronization of welding signals and high speed camera to study the behaviour of voltage signal under different drop transfer modes. Findings: The results reveal that the welding arc is significantly affected by the molten droplet detachment. In fact, results indicate that sudden increase and drop in voltage just before and after the drop detachment can be used to characterize the voltage behaviour of different drop transfer mode in GMAW-P. Research limitations/implications: The results show that voltage signal carry rich information about different drop transfer occurring in GMAW-P. Hence it’s possible to detect different drop transfer modes. Future work should concentrate on development of filters for detection of different drop transfer modes. Originality/value: Determination of drop transfer mode with GMAW-P is crucial for the appropriate selection of pulse welding parameters. As change in drop transfer mode results in poor weld quality in GMAW-P, so in order to estimate the working parameters and ensure stable GMAW-P understanding the voltage behaviour of different drop transfer modes in GMAW-P will be useful. However, in case of GMAW-P hardly any attempt is made to analyse the behaviour of voltage signal for different drop transfer modes. This paper analyses the voltage signal behaviour of different drop transfer modes for GMAW-P.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Images obtained through fluorescence microscopy at low numerical aperture (NA) are noisy and have poor resolution. Images of specimens such as F-actin filaments obtained using confocal or widefield fluorescence microscopes contain directional information and it is important that an image smoothing or filtering technique preserve the directionality. F-actin filaments are widely studied in pathology because the abnormalities in actin dynamics play a key role in diagnosis of cancer, cardiac diseases, vascular diseases, myofibrillar myopathies, neurological disorders, etc. We develop the directional bilateral filter as a means of filtering out the noise in the image without significantly altering the directionality of the F-actin filaments. The bilateral filter is anisotropic to start with, but we add an additional degree of anisotropy by employing an oriented domain kernel for smoothing. The orientation is locally adapted using a structure tensor and the parameters of the bilateral filter are optimized for within the framework of statistical risk minimization. We show that the directional bilateral filter has better denoising performance than the traditional Gaussian bilateral filter and other denoising techniques such as SURE-LET, non-local means, and guided image filtering at various noise levels in terms of peak signal-to-noise ratio (PSNR). We also show quantitative improvements in low NA images of F-actin filaments. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst conventional bit level pipelining introduces an m cycle delay, it does allow m separate computations to be processed at throughput rates comparable to that using word level systolic arrays. We concentrate on exploiting this delay and describe a systematic method for the design of high performance multiplexed IIR filters. Two multiply and accumulate structures are identified based on shift-and-add and carry-save data organisations which can be used as building blocks in the design of IIR filters. By replacing the word level multiply and accumulate units in word level systolic structures with their equivalent bit level circuits and introducing latches to ensure correct timing, numerous architectures can be designed that process multiplexed data directly without any additional circuit overhead.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aims: Lixisenatide, a once-daily prandial glucagon-like peptide-1 receptor agonist, reduces postprandial (PP) glycaemic excursions and HbA 1c . We report an exploratory analysis of the GetGoal-M and S trials in patients with type 2 diabetes mellitus (T2DM) with different changes in PP glucagon levels in response to lixisenatide treatment. Materials and methods: Patients (n=423) were stratified by their change in 2 hour PP glucagon level between baseline evaluation and Week 24 of treat - ment with lixisenatide as add-on to oral antidiabetics (OADs) into groups of Greater Change (GC; n=213) or Smaller Change (SC; n=210) in plasma glucagon levels (median change -23.57 ng/L). ANOVA and Chi-squared tests were used for the comparison of continuous and categorical variables, respec - tively. Baseline and endpoint continuous measurements in each group were compared using paired t -tests. Results: Mean change from baseline in 2 hour PP glucagon levels for the GC vs SC groups was -47.19 vs -0.59 ng/L (p<0.0001), respectively. Patients in the GC group had a shorter mean duration of diabetes (7.3 vs 9.0 years; p=0.0036) and lesser OAD use (4.5 vs 5.7 years; p=0.0092) than those in the SC group. Patients in the GC group had a greater mean reduction in HbA 1c (-1.10 vs -0.67%; p<0.0001), fasting plasma glucose (FPG; -25.20 vs -9.30 mg/dL [p<0.0001]), PP plasma glucose (PPG; -129.40 vs -78.22 mg/dL [p<0.0001]), and a greater drop in weight (-2.27 vs -1.17 kg; p=0.0002) and body mass index (-0.84 vs -0.44 kg/m 2 ; p=0.0002) than those in the SC group. More patients in the GC group also achieved composite endpoints, including HbA 1c <7% with no symptomatic hypoglycaemia and no weight gain (40.38 vs 19.52%; p<0.0001), than in the SC group. Conclusion: Greater reductions in PP glucagon associated with lixisenatide as add-on to OADs in patients with T2DM are also associated with greater reductions in HbA1c, FPG, PPG, and greater weight loss, highlighting the importance of glucagon suppression on therapeutic response. Clinical Trial Registration Number: NCT00712673; NCT00713830 Supported by: Sanof

Relevância:

20.00% 20.00%

Publicador: