526 resultados para 988
Resumo:
Crystals suitable for high resolution X-ray diffraction analysis have been grown of the 29,774-Da protein, xylanase (1,-4-beta-xylan xylanohydrolase EC 3.2.1.8) from the thermophilic fungus Thermoascus aurantiacus. This protein, an endoxylanase demonstrates the hydrolysis of β-(1-4)-Image -xylose linkage in xylans and crystallizes as monoclinic pinacoids in the presence of ammonium sulphate buffered at pH 6·5, and also with neutral polyethylene glycol 6000. The crystals belong to space group P 21 and have cell dimensions, a = 41·2 Å, b = 67·76 Å, c = 51·8 Å; β = 113·2°.
Resumo:
Kinetic constants of MAb-hCG interactions have been determined using solid phase binding of I-125[hCG] to immobilized MAb. While association has been shown to follow the expected pattern, dissociation consists of at least two reversible steps, one with a rate constant of 0.0025 min(-1), and a second with a rate constant of 0.00023 min(-1). Validity of affinity constant measurements in the light of the complex reaction kinetics is discussed, A comparison between the method of surface plasmon resonance technology (BIAcore) and solid phase binding (SPB) for determination of kinetic parameters shows that SPB provides not only a cost-effective approach for determination of realtime kinetic parameters of macromolecular ligand-ligate interaction but also a method with several advantages over the BIAcore system in investigating the mechanism of antigen-antibody interaction.
Resumo:
The effects of 100 MeV Oxygen and 200 MeV Silver ions on the structural and transport properties of YBCO thin films are reported. Both normal state and superconducting properties were studied on Laser ablated and high pressure oxygen sputtered films. Precise electrical resistance and critical current measurements near T-c were made and the data obtained were analysed in the light of existing models of para-coherence near T-c and the other aspects of radiation damage arising from microstructural studies such as atomic force microscopy (AFM). There was evidence of sputtering by high energy ions from AFM measurement. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
Writing the hindered rotor (hr) partition function as the trace of (rho) over cap = e(-beta(H) over cap hr), we approximate it by the sum of contributions from a set of points in position space. The contribution of the density matrix from each point is approximated by performing a local harmonic expansion around it. The highlight of this method is that it can be easily extended to multidimensional systems. Local harmonic expansion leads to a breakdown of the method a low temperatures. In order to calculate the partition function at low temperatures, we suggest a matrix multiplication procedure. The results obtained using these methods closely agree with the exact partition function at all temperature ranges. Our method bypasses the evaluation of eigenvalues and eigenfunctions and evaluates the density matrix for internal rotation directly. We also suggest a procedure to account for the antisymmetry of the total wavefunction in the same. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Electrodeposition of nickel/barium hexa-aluminate (Ni/BHA) composite coatings has been carried out from a Watt's bath on mild steel substrate. BHA powders with plate habit were synthesized by solution combustion synthesis followed by heat treatment to ensure complete conversion to the hexa-aluminate phase. Heat treated material was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) combined with X-ray analysis. The dispersion behaviour and stability of BHA suspensions with cationic and anionic surfactants at room temperature were studied by dynamic light scattering under different pH. The influence of BHA concentration in the electrolytic bath, deposition temperature, pH, current density and duty cycle on particle incorporation in the coatings were studied and conditions for maximum particle incorporation were established. Coatings with a roughness of about 0 center dot 4 mu m were produced by using this technique. Effect of BHA content on microhardness was also investigated. A reasonably good thickness of the coatings was achieved in a given set of conditions.
Resumo:
A nanostructured surface layer was formed on an Inconel 600 plate by subjecting it to surface mechanical attrition treatment at room temperature. Transmission electron microscopy and high-resolution transmission electron microscopy of the treated surface layer were carried out to reveal the underlying grain refinement mechanism. Experimental observations showed that the strain-induced nanocrystallization in the current sample occurred via formation of mechanical microtwins and subsequent interaction of the microtwins with dislocations in the surface layer. The development of high-density dislocation arrays inside the twin-matrix lamellae provides precursors for grain boundaries that subdivide the nanometer-thick lamellae into equiaxed, nanometer-sized grains with random orientations.
Resumo:
Con el propósito de evaluar el rendimiento y la capacidad de almacenamiento de catorce cultivares de cebolla (Allium Cap L.), se realizó un ensayo en el Centro experimental “Raúl González A”, del valle de Sebaco durante el periodo Diciembre 1987 a Julio 1,988 El método de siembra utilizado fue el de trasplante: el diseño experimental utilizado fue el de bloques completos al azar con 4 repeticiones y parcela experimental de 6 mts. De largo y 1.6 mts de Ancho. El área de la parcela útil fue de 5.4 mts2. Los paramentos evaluados fueron los siguientes: longitud de planta, numero de hojas, diámetro polar y ecuatorial, grados Srix porcentaje de plantas sin bulbo, porcentaje de bulbos dobles, porcentaje de bulbos enfermos y el rendimiento. En almacenamiento se evaluó el porcentaje de bulbos comerciales al final del almacenamiento. En base al ANDEVA y la prueba de Tukey al 5% de determino que las variedades Toro PRR ( 20.262 kg/ha), Grand prix (18.194 kg/ha) y Ringer Grano PRR (17.898) superan en rendimiento al resto de las variedades: Los materiales se sabe que no presentan los rendimientos más pobres, aunque se destaca el hecho de que los materiales mejorados superan al material original. En el almacenamiento mostrado un mejor comportamiento las variedades Yellow Granex y Red Creole con 80% de bulbos comerciales al final del periodo de almacenamiento.
Resumo:
提出一种仅需一台染料激光器即可同时测量火焰中氢和氧的CARS谱的新方法。取带宽为120cm~(-1),中心波长位于580.4nm的Stokes光束与532nm的泵浦光束相配合,同时测量氢扩散火焰中的氢和氧的CARS谱,用氢的S(6)和S(5)的积分强度比确定火焰中的温度并与氮的Q支CARS谱测量的温度和经过热损耗修正的热电偶测得的温度取得了相当好的一致结果。一次测出氢和氧的CARS谱,避免多次测量中参数的难以重复性,提高了以温度为参数来确定浓度的准确性。
Resumo:
Consultoria Legislativa - Área XIV - Comunicação Social, Informática, Telecomunicações, Sistema Postal, Ciência e Tecnologia.
Resumo:
487 p. : il., col.
Resumo:
Introducción: La medición de la concentración de hierro hepática (CHH) por RM es una técnica no invasiva de gran utilidad en el diagnóstico de los pacientes con sospecha de sobrecarga férrica en hígado. Objetivo:Validar la eficacia de la RM 1 Tesla en la determinación de la (CHH) en pacientes con sospecha de sobrecarga férrica. Validar su capacidad para diagnosticar o descartar la presencia de una CHH sugestiva de hemocromatosis. Pacientes y métodos:Estudio observacional, transversal, con inclusión prospectiva de pacientes consecutivos. De 2002 a 2010 hemos obtenido la CHH estimada mediante RM 1 Tesla (método Gandon) y de RM 1,5 Tesla (método Alústiza), y mediante BH, en 56 pacientes consecutivos (58RM:35/23). Resultados:Grupo RM 1 Tesla: de acuerdo con CHH en BH, 15 pacientes clasificados como normales (<36µmol/g)-la RM valoró correctamente 7; sobreestimó 8-; 15 grupo hemosiderosis (36-80 µmol/g)-RM valoró correctamente 5, sobreestimó 10-; 5 grupo hemocromatosis (>80 µmol/g)-valoró correctamente las 5-. Existió una correlación entre la determinación de la CHH por BH y RM 1 Tesla con r=0.619. Existieron diferencias estadísticamente significativas (p<0.05) entre CHH media por biopsia (53.43/DE45.67/IC95%37.74 a 69.12) y por RM 1 Tesla (76.14/DE47.31/IC95% 60.46 a 92.97), con sobrevaloración por parte de la RM. Grupo RM 1,5 Tesla: de acuerdo con CHH en BH, normal en 14, hemosiderosis en 6 y hemocromatosis en 3. La RM valoró correctamente 6 y sobreestimó 8 en grupo normal; grupo hemosiderosis, 3 correctamente, 3 sobrevalorados; grupo hemocromatosis, valoró correctamente los 3. La correlación entre CHH por BH y RM 1,5 Tesla fue de r=0.815. La CHH media obtenida por BH (69,34/DE152.1/IC95% 3.57 a 135.1 ) y RM 1,5 Tesla (70.43/DE 57.63/IC95% 45.51 a 95.36) no demostraron diferencias significativas (p>0.05). Conclusiones: La determinación de CHH por RM 1 Tesla (método Gandon) es útil para diagnosticar o descartar hemocromatosis y para diagnosticar CHH normal. Existe una importante tendencia a la sobreestimación en pacientes sin y con sobrecarga férrica en la CHH obtenida por RM 1 Tesla. La determinación de CHH por RM 1,5 Tesla (método Alústiza) es superior a la de RM 1 Tesla, aunque también existe una tendencia a sobreestimar. La CHH media obtenida por BH o RM 1,5 Tesla no tuvieron diferencias significativas. En cambio si existieron entre BH y RM 1 Tesla.