999 resultados para 10 kV
Resumo:
The distribution of short-circuit current is investigated by means of two methods, one direct and the other analytic; both methods consider uniform probability distribution of line faults. In the direct method, the procedure consists of calculating fault currents at equidistant points along the line, starting from one of the end points and considering the other end open. The magnitude of the current is classified according to Brazilian standards (regulation NBR-7118). The analytic method assumes that the distribution of short-circuit currents through the busbar and the distribution of the line length connected to it are known, as well as the independence of values. The method is designed to determine the probability that fault currents through a line will surpass the pre-established magnitude, thus generating frequency distribution curves of short-circuit currents along the lines.
Resumo:
This paper addresses the topics required for the selection of surge arresters used, the output of autotransformers, which protect the system Auxiliary Services (SE) of an electrical substation. Surge arresters used are part of the Protection System Lightning (SPDA). Transmission lines mostly run through regions with orographic well diversified and have constant weather changes, which lead to many undesirable interactions with electromagnetic phenomena, such as giving rise to blackout on 10 November 2009, which left nine states without power, which led to unplanned shutdowns in the system that left millions of people without electricity. This work of completion is to determine whether the method used in the selection of surge arresters meet the protection needs faced by a substation auxiliary services, through the use of software use ATPDraw
Resumo:
In questo elaborato sono descritti la progettazione e lo sviluppo di un sistema tomografico con sorgente di raggi X da 300 kV per analisi nel campo dei Beni Culturali; in particolare sono stati effettuati test preliminari sia per verificare le prestazioni del tubo a raggi X e dello schermo scintillatore sia per avere indicazioni utili alla progettazione (e conseguente costruzione) del box di rivelazione. Il collaudo della sorgente di raggi X è stato eseguito con lo studio dell'andamento della dose integrale e/o del rateo di dose in funzione della tensione, della corrente e del tempo d'irraggiamento. La caratterizzazione dello schermo scintillatore di CsI(Tl) è basata sul confronto delle sue caratteristiche con uno schermo analogo di spessore differente nelle stesse condizioni sperimentali, attraverso lo studio dei parametri standard dei dispositivi per imaging, quali la curva di risposta, il rapporto segnale-rumore e la risoluzione spaziale. Inoltre, come ulteriore test, lo schermo scintillatore è stato utilizzato per l’indagine tomografica di alcuni pani di terra contenenti olle di epoca villanoviana. Per la progettazione del box rivelatore sono state invece svolte misure di tipo ottico. I vari test svolti in laboratorio hanno dato risultati positivi e hanno dimostrato la validità dei componenti scelti per il nuovo sistema tomografico, il cui assemblaggio verrà completato a breve, essendo stata ultimata proprio in queste settimane la costruzione del box di rivelazione.
Resumo:
The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 mu A C- out of gaseous samples with an efficiency of 3-6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3-30 mu g carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of C-14/C-12 could be repeated within statistical errors to better than 1.0% and the C-13/C-12 ratios to better than 0.2%. The blank was < 1 pMC.
Resumo:
Axonal outgrowth and the formation of the axon initial segment (AIS) are early events in the acquisition of neuronal polarity. The AIS is characterized by a high concentration of voltage-dependent sodium and potassium channels. However, the specific ion channel subunits present and their precise localization in this axonal subdomain vary both during development and among the types of neurons, probably determining their firing characteristics in response to stimulation. Here, we characterize the developmental expression of different subfamilies of voltage-gated potassium channels in the AISs of cultured mouse hippocampal neurons, including subunits Kv1.2, Kv2.2 and Kv7.2. In contrast to the early appearance of voltage-gated sodium channels and the Kv7.2 subunit at the AIS, Kv1.2 and Kv2.2 subunits were tethered at the AIS only after 10 days in vitro. Interestingly, we observed different patterns of Kv1.2 and Kv2.2 subunit expression, with each confined to distinct neuronal populations. The accumulation of Kv1.2 and Kv2.2 subunits at the AIS was dependent on ankyrin G tethering, it was not affected by disruption of the actin cytoskeleton and it was resistant to detergent extraction, as described previously for other AIS proteins. This distribution of potassium channels in the AIS further emphasizes the heterogeneity of this structure in different neuronal populations, as proposed previously, and suggests corresponding differences in action potential regulation.
Resumo:
The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation between the distance and the impedance seen by the distance protection relays is not linear and therefore the location is not accurate enough. This paper presents a simple and economical method to identify the subsection between autotransformers and the conductor (catenary or feeder) where the ground fault is happening. This method is based on the comparison of the angle between the current and the voltage of the positive terminal in each autotransformer. Consequently, after the identification of the subsection and the conductor with the ground defect, only the subsection where the ground fault is present will be quickly removed from service, with the minimum effect on rail traffic. This method has been validated through computer simulations and laboratory tests with positive results.