983 resultados para “Horizontal ridge augmentation” AND “dental implants”


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentists are often faced with extensively resorbed mandibular ridges with shallow buccal vestibule and high insertion of the mentalis muscle in relation to the crest of the ridge, causing the displacement of the prosthesis. Vestibuloplasty techniques aim at eliminating the muscle insertions, reposition the mucosa, and increase the area chapeável, giving more stability to the prosthesis. Among the techniques to deepen the vestibule are submucosal vestibuloplasties by secondary epithelialization and with mucosal and skin grafts. We will discuss vestibuloplasty by secondary epithelialization with emphasis on the so-called modified Kazanjian technique. This technique provides an appropriate result and does not require hospitalization, additional surgery at the donor, or prolonged periods without the use of prosthesis. © 2013 by Mutaz B. Habal, MD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To present some immunological aspects of fresh-frozen allogeneic bone grafting for lateral bone augmentation, based on the quantitative evaluation of IL-10, IL-1β, IFN- γ and TNF- α in patients sera. Material and methods: Thirty-three partially or totally edentulous patients received fresh-frozen allogeneic bone (AL - 20 patients) or autologous bone onlay block grafts (AT - 13 patients) prior to oral implant placement. Blood samples were collected from each patient at various time-points during a 6 month-period (baseline, 14, 30, 90 and 180 days postoperatively). Quantitative evaluation of IL-10, IL-1β, IFN- γ and TNF- α was performed by enzyme linked immunosorbent assay (ELISA). Results: For all evaluated markers and at all evaluated periods, inter-group comparisons showed no statistically significant differences between the groups, while the observed values were within normal levels. For AL-treated patients, intra-group evaluation showed statistically significant increase of TNF-α from baseline to 90 (P < 0.001) and 180 (P < 0.01) days, and from 14 to 90 (P < 0.01) and 180 (P < 0.05) days. IFN- γ showed intercalated results, with a decrease from baseline to 14 days (P < 0.05), and increase from 14 to 90 days (P < 0.001) and 180 (P < 0.05) days. No differences between the periods of evaluation were found for the AT group. Conclusions: AL grafting for lateral bone augmentation, similar to AT grafting, does not seem to challenge the immune system significantly. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the release of bone markers during osseointegration of immediately loaded and nonloaded implants. Forty patients who were indicated for rehabilitation with dental implants randomly received either implant and prosthesis placement within 72 hours (group IM) or implant insertion and no prosthesis placement (group NL). Peri-implant crevicular fluid was collected immediately after implant insertion and 7, 15, 30, 60, 90, and 120 days after surgery and levels of osteoprotegerin, transforming growth factors, osteocalcin, osteopontin, and parathyroid hormone were evaluated using Luminex assay. Bleeding index and peri-implantar sulcus depth were also evaluated. The data were compared using statistical tests ( = 5%). No statistical difference was found regarding demographic and clinical parameters (p > .05). Transforming growth factors, osteoprotegerin, osteopontin, and parathyroid hormone presented an earlier release peak in group IM than in NL group (p < .05). Osteocalcin achieved higher levels in group IM versus group NL between 7 and 30 days of evaluation (p < .05). It may be concluded that earlier loading positively modulates bone mediators release around immediately loaded implants when compared with nonloaded dental implants (ClinicalTrials.gov NCT01909999).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surface of dental implants is an important factor for osseointegration process and different methods of surface treatment have been described. Objective: To investigate the bone apposition in implant surface treated with sandblasting and acid-etching. Material and methods: Ten rabbits were selected and received one implant treated with method I in the left tibia and one implant treated with method II in the right tibia. Then, twenty implants were divided in two groups, according to methods of sandblasting and acid-etching (method I and method II). After 7, 14, 30, 45 and 60 days, tibias were retrieved and submitted to histotechnical procedures. The percentages of bone–implant contact (BIC) and bone area between threads (BABT) were determined throughout histomorphometric analysis and bone apposition was detected in implants of both groups. Results: In BABT measurements, an increase was observed after 45 and 60 days in the method II, compared to method I and no differences were found after 7, 14 and 30 days. In BIC measurements, an increase was detected with method II at 45 days when compared to method I. No differences between groups in BIC values were observed after 7, 14, 30 and 60 days. Conclusion: Our data demonstrated that implants treated with the method II presented increase in the contact between bone and implant after 45 days compared to method I. Moreover, with concern to bone area between threads, it was observed an increased in the method II after 45 and 60 days. However, both groups can be successfully used as a therapeutic strategy to rehabilitation of edentulous patients. Then, further experiments are needed to evaluate, in depth, the putative differential role of each surface treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The calvarial bone is highlighted as a good donor area for large reconstructions of atrophic jaw for subsequent rehabilitation with implant-supported prosthesis. The aim of this study was to observe and measure through histological and histometric evaluation, the cellular events that occur at the interface of union from onlay parietal bone graft on the maxilla of 10 patients, after a period of 6 months of incorporation. The biopsies were performed at the time of installation of osseointegrated implants. The bone contact area represented 78.75% and connective contact 21.25%. The region of connective union between the bone graft to the maxillae presented new bone formation (41.26%), marrow bone (36.06%), osteoid tissue (15.86%) and connective tissue (6.80%). All samples had good graft incorporation to the receptor bed with osteogenic activity and absence of inflammatory cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

http://www.woodheadpublishing.com/en/book.aspx?bookID=1598

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In implant dentistry, there is a need for synthetic bone substitute blocks to support ridge augmentation in situations where large bone volumes are missing. Polycaprolactone-based scaffolds demonstrated excellent results in bone tissue engineering applications. The use of customized polycaprolactone-tricalcium phosphate (PCL-TCP) displayed promising results from recent rat femur and rabbit calvaria studies. However, data from clinically representative models in larger animals do not exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To perform a literature review on peri-implant metastases and primary malignoma and report a case of a pulmonary metastasis around dental implants of the anterior mandibular jaw that mimicked peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the hard and the soft tissue parameters around implants supporting fixed prostheses over a period of 5 years and the possible association to the increase in periimplant bone density (IPBD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess retrospectively, over at least 5 years, the incidences of technical and biological complications and failures in young adult patients with birth defects affecting the formation of teeth. MATERIAL AND METHODS: All insurance cases with a birth defect that had crowns and fixed dental prostheses (FDPs) inserted more than 5 years ago were contacted and asked to participate in a reexamination. RESULTS: The median age of the patients was 19.3 years (range 16.6-24.7 years) when prosthetic treatment was initiated. Over the median observation period of 15.7 years (range 7.4-24.9 years) and considering the treatment needs at the reexamination, 19 out of 33 patients (58%) with reconstructions on teeth remained free from all failures or complications. From the patients with FDPs and single unit crowns (SCs) on implants followed over a median observation period of 8 years (range 4.6-15.3 years), eight out of 17% or 47% needed a retreatment or repair at some point due to a failure or a complication. From the three groups of patients, the cases with amelogenesis/dentinogenesis imperfecta demonstrated the highest failure and complication rates. In the cases with cleft lip, alveolus and palate (CLAP) or hypodontia/oligodontia, 71% of the SCs and 73% of the FDPs on teeth (FDP T) remained complication free over a median observation period of about 16 years. Sixty-two percent of the SCs and 64% of the FDPs on implants remained complication free over 8 years. Complications occurred earlier with implant-supported reconstructions. CONCLUSIONS: Because healthy, pristine teeth can be left unprepared, implant-supported SCs and FDPs are the treatment choice in young adults with birth defects resulting in tooth agenesis and in whom the edentulous spaces cannot be closed by means of orthodontic therapy. However, the trend for earlier and more frequent complications with implant-supported reconstructions in young adults, expecting many years of function with the reconstructions, has to be weighed against the benefits of keeping teeth unprepared. In cases with CLAP in which anatomical conditions render implant placement difficult and in which teeth adjacent to the cleft require esthetic corrections, the conventional FDP T still remains the treatment of choice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report presents the treatment sequence of a 56 years old patient after he developed periimplantitis at the implant in position of tooth 22. This implant was integrated in an overdenture reconstruction connected to a soldered screw retained gold bar. The entire 2-stage procedure of implant explantation, simultaneous bone augmentation and new implant placement is documented. The onlay-graft was performed by means of the Transfer-Ring-Control System (Meisinger). The existing gold bar could be resoldered and adapted to the new implant. Accordingly the overdenture was relined and the female retainer mounted. The treatment period covered almost one year.