876 resultados para variance analysis
Resumo:
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.
Resumo:
In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.
Resumo:
Background: Investigation and discrimination of neuromuscular variables related to the complex aetiology of low back pain could contribute to clarifying the factors associated with symptoms. Objective: Analysing the discriminative power of neuromuscular variables in low back pain. Methods: This study compared muscle endurance, proprioception and isometric trunk assessments between women with low back pain (LBP, n=14) and a control group (CG, n=14). Multivariate analysis of variance and discriminant analysis of the data were performed. Results: The muscle endurance time (s) was shorter in the LBP group than in the CG (p=0.004) with values of 85.81 (37.79) and 134.25 (43.88), respectively. The peak torque (Nm/kg) for trunk extension was 2.48 (0.69) in the LBP group and 3.56 (0.88) in the GG (p=0.001); for trunk flexion, the mean torque was 1.49 (0.40) in the LBP group and 1.85 (0.39) in the CG (p=0.023). The repositioning error (degrees) before the endurance test was 2.66 (1.36) in the LBP group and 2.41 (1.46) in the CG (p=0.664), and after the endurance test, it was 2.95 (1.94) in the LBP group and 2.00 (1.16) in the CG (p=0.06). Furthermore, the variables showed discrimination between the groups (p=0.007), with 78.6% of the individuals with low back pain correctly classified in the LBP group. In turn, variables related to muscle activation showed no difference in discrimination between the groups (p=0.369). Conclusion: Based on these findings, the clinical management of low back pain should consist of both resistance and strength training, particularly in the extensor muscles.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed at evaluating the validity, reliability, and factorial invariance of the complete (34-item) and shortened (8-item and 16-item) versions of the Body Shape Questionnaire (BSQ) when applied to Brazilian university students. A total of 739 female students with a mean age of 20.44 (standard deviation = 2.45) years participated. Confirmatory factor analysis was conducted to verify the degree to which the one-factor structure satisfies the proposal for the BSQ's expected structure. Two items of the 34-item version were excluded because they had factor weights (lambda)< 40. All models had adequate convergent validity (average variance extracted =.43-.58; composite reliability=.85-.97) and internal consistency (alpha =.85-.97). The 8-item B version was considered the best shortened BSQ version (Akaike information criterion = 84.07, Bayes information criterion = 157.75, Browne-Cudeck criterion= 84.46), with strong invariance for independent samples (Delta chi(2)lambda(7)= 5.06, Delta chi(2)Cov(8)= 5.11, Delta chi(2)Res(16) = 19.30). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Pós-graduação em Genética e Melhoramento Animal - FCAV
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Currently, biodiversity is threatened by several factors often associated with human population growth and the extension of areas occupied by human activity. In particular, freshwater fish fauna is affected by overfishing, deforestation, water pollution, introduction of exotic species and habitat fragmentation promoted by hydroelectric dams, among other environmental impact factors. Several action plans to preserve ichthyofauna biodiversity have been adopted; however, these plans frequently cover only a small number of species, and decisions are often made without strong scientific support. This study aimed to evaluate the genetic aspects of wild groups of Brycon orbignyanus, an endangered fish species, using microsatellites and D-loop regions to identify the genetic structure of the samples and to establish priority areas for conservation based on the genetic patterns of this species. The results indicated that the samples showed levels of genetic variability compatible with others studies with Neotropical fishes. However, the results obtained in the analysis of molecular variance (AMOVA) for microsatellites (F (ST) = 0.258) and D-loop (F (ST) = 0.234) and the interpopulation fixation index revealed that B. orbignyanus was structured in different subpopulations in the La Plata River basin; the areas with better environmental conditions also showed subgroups with higher rates of genetic variability. Future conservation actions addressing these sites should consider two different management units: the complex formed by the Ivinhema River, Upper Parana, Camargo Port and Ilha Grande groups; and the complex formed by the Verde River and Sucuriu River groups.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)