636 resultados para urethral stent


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Pelvic floor rehabilitation is the conservative therapy of choice for women with stress urinary incontinence (SUI). The success rate of surgical procedures in SUI patients with intrinsic sphincter deficiency (ISD) is low. The aim of this study was to analyse the effect of a standardized physiotherapy on patients with SUI and normotonic urethra and ISD. METHODS In this study, 64 patients with ISD and 69 patients with normotonic urethra were enrolled. Maximum urethral pressure (MUCP) >20 cm H2 O was considered as normotonic urethral pressure. Before and after physiotherapy MUCP was measured and cough testing was performed. Additionally, patient reported outcome was assessed using the King's Health Questionnaire (KHQ). For statistical analyses Excel 2010 (Microsoft Inc; Redmond, Washington) and SPSS 20 (SPSS Inc; Chicago, Illinois) for Windows were used. Power calculation was based on the primary endpoint incontinence impact and general health. For power calculation, GraphPad Statmate version 2.00 for Windows was used. RESULTS Sixty-four patients with ISD and 69 patients with normotonic urethra were included in the study. In SUI patients with normotonic and hypotonic urethra KHQ-scores regarding the primary endpoins "general health" and "incontinence impact" significantly improved following standardized physiotherapy. In both groups MUCP increased after physiotherapy. In SUI patients with ISD standardized physiotherapy resulted in a decreased incidence of a positive cough test. CONCLUSIONS Standardized physiotherapy should be offered to patients with SUI and ISD. Long-term results are subject to future studies. Neurourol. Urodynam. © 2015 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study sought to evaluate: 1) the effect of impaired renal function on long-term clinical outcomes in women undergoing percutaneous coronary intervention (PCI) with drug-eluting stent (DES); and 2) the safety and efficacy of new-generation compared with early-generation DES in women with chronic kidney disease (CKD). BACKGROUND The prevalence and effect of CKD in women undergoing PCI with DES is unclear. METHODS We pooled patient-level data for women enrolled in 26 randomized trials. The study population was categorized by creatinine clearance (CrCl) <45 ml/min, 45 to 59 ml/min, and ≥60 ml/min. The primary endpoint was the 3-year rate of major adverse cardiovascular events (MACE). Participants for whom baseline creatinine was missing were excluded from the analysis. RESULTS Of 4,217 women included in the pooled cohort treated with DES and for whom serum creatinine was available, 603 (14%) had a CrCl <45 ml/min, 811 (19%) had a CrCl 45 to 59 ml/min, and 2,803 (66%) had a CrCl ≥60 ml/min. A significant stepwise gradient in risk for MACE was observed with worsening renal function (26.6% vs. 15.8% vs. 12.9%; p < 0.01). Following multivariable adjustment, CrCl <45 ml/min was independently associated with a higher risk of MACE (adjusted hazard ratio: 1.56; 95% confidence interval: 1.23 to 1.98) and all-cause mortality (adjusted hazard ratio: 2.67; 95% confidence interval: 1.85 to 3.85). Compared with older-generation DES, the use of newer-generation DES was associated with a reduction in the risk of cardiac death, myocardial infarction, or stent thrombosis in women with CKD. The effect of new-generation DES on outcomes was uniform, between women with or without CKD, without evidence of interaction. CONCLUSIONS Among women undergoing PCI with DES, CKD is a common comorbidity associated with a strong and independent risk for MACE that is durable over 3 years. The benefits of newer-generation DES are uniform in women with or without CKD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The safety and efficacy of new-generation drug-eluting stents (DES) in women with multiple atherothrombotic risk (ATR) factors is unclear. METHODS AND RESULTS We pooled patient-level data for women enrolled in 26 randomized trials. Study population was categorized based on the presence or absence of high ATR, which was defined as having history of diabetes mellitus, prior percutaneous or surgical coronary revascularization, or prior myocardial infarction. The primary end point was major adverse cardiovascular events defined as a composite of all-cause mortality, myocardial infarction, or target lesion revascularization at 3 years of follow-up. Out of 10 449 women included in the pooled database, 5333 (51%) were at high ATR. Compared with women not at high ATR, those at high ATR had significantly higher risk of major adverse cardiovascular events (15.8% versus 10.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.34-1.75; P=0.006) and all-cause mortality. In high-ATR risk women, the use of new-generation DES was associated with significantly lower risk of 3-year major adverse cardiovascular events (adjusted hazard ratio: 0.69; 95% confidence interval: 0.52-0.92) compared with early-generation DES. The benefit of new-generation DES on major adverse cardiovascular events was uniform between high-ATR and non-high-ATR women, without evidence of interaction (Pinteraction=0.14). At landmark analysis, in high-ATR women, stent thrombosis rates were comparable between DES generations in the first year, whereas between 1 and 3 years, stent thrombosis risk was lower with new-generation devices. CONCLUSIONS Use of new-generation DES even in women at high ATR is associated with a benefit consistent over 3 years of follow-up and a substantial improvement in very-late thrombotic safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to compare the efficacy of amphilimus-eluting stents (AES) with that of everolimus-eluting stents (EES) in patients with diabetes mellitus (DM). BACKGROUND The AES is a polymer-free drug-eluting stent that elutes sirolimus formulated with an amphiphilic carrier from laser-dug wells. This technology could be associated with a high efficacy in patients with DM. METHODS This was a multicenter, randomized, noninferiority trial. Patients with DM medically treated with oral glucose-lowering agents or insulin and de novo coronary lesions were randomized in a 1:1 fashion to AES or EES. The primary endpoint was the neointimal (NI) volume obstruction assessed by optical coherence tomography at 9-month follow-up. RESULTS A total of 116 lesions in 112 patients were randomized. Overall, 40% were insulin-treated patients, with a median HbA1c of 7.3% (interquartile range: 6.7% to 8.0%). The primary endpoint, NI volume obstruction, was 11.97 ± 5.94% for AES versus 16.11 ± 18.18% for EES, meeting the noninferiority criteria (p = 0.0003). Pre-specified subgroup analyses showed a significant interaction between stent type and glycemic control (p = 0.02), with a significant reduction in NI hyperplasia in the AES group in patients with the higher HbA1c (p = 0.03). By quantitative coronary angiography, in-stent late loss was 0.14 ± 0.24 for AES versus 0.24 ± 0.57 mm for EES (p = 0.27), with a larger minimal lumen diameter at follow-up for AES (p = 0.02), mainly driven by 2 cases of occlusive restenosis in the EES group. CONCLUSIONS AES are noninferior to EES for the coronary revascularization of patients with DM. These results suggest a high efficacy of the AES and may support the potential benefit of this stent in patients with DM. (A Randomized Comparison of Reservoir-Based Polymer-Free Amphilimus-Eluting Stents Versus Everolimus-Eluting Stents With Durable Polymer in Patients With Diabetes Mellitus [RESERVOIR]; NCT01710748).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mehrere kürzlich publizierte, prospektive, randomisierte Studien haben die Überlegenheit der mechanischen Thrombektomie mit Stent-Retrievern in Kombination mit intravenöser Thrombolyse gegenüber der alleinigen intravenösen Thrombolyse beim akuten ischämischen Hirnschlag auf dem Boden eines proximalen Hirngefässverschlusses bewiesen. Der folgende Artikel gibt eine Übersicht über die Entwicklung der endovaskulären Hirnschlagbehandlung mit Fokus auf die kürzlich erschienenen bahnbrechenden Studien.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sexually transmitted infections (STIs) are a major public health problem, and controlling their spread is a priority. According to the World Health Organization (WHO), there are 340 million new cases of treatable STIs among 15–49 year olds that occur yearly around the world (1). Infection with STIs can lead to several complications such as pelvic inflammatory disorder (PID), cervical cancer, infertility, ectopic pregnancy, and even death (1). Additionally, STIs and associated complications are among the top disease types for which healthcare is sought in developing nations (1), and according to the UNAIDS report, there is a strong connection between STIs and the sexual spread of HIV infection (2). In fact, it is estimated that the presence of an untreated STI can increase the likelihood of contracting and spreading HIV by a factor up to 10 (2). In addition, developing countries are poorer in resources and lack inexpensive and precise diagnostic laboratory tests for STIs, thereby exacerbating the problem. Thus, the WHO recommends syndromic management of STIs for delivering care where lab testing is scarce or unattainable (1). This approach utilizes the use of an easy to use algorithm to help healthcare workers recognize symptoms/signs so as to provide treatment for the likely cause of the syndrome. Furthermore, according to the WHO, syndromic management offers instant and legitimate treatment compared to clinical diagnosis, and that it is also more cost-effective for some syndromes over the use of laboratory testing (1). In addition, even though it has been shown that the vaginal discharge syndrome has low specificity for gonorrhea and Chlamydia and can lead to over treatment (1), this is the recommended way to manage STIs in developing nations. Thus, the purpose of this paper is to specifically address the following questions: is syndromic management working to lower the STI burden in developing nations? How effective is it, and should it still be recommended? To answer these questions, a systematic literature review was conducted to evaluate the current effectiveness of syndromic management in developing nations. This review examined published articles over the past 5 years that compared syndromic management to laboratory testing and had published sensitivity, specificity, and positive predicative value data. Focusing mainly on vaginal discharge, urethral discharge, and genital ulcer algorithms, it was seen that though syndromic management is more effective in diagnosing and treating urethral and genial ulcer syndromes in men, there still remains an urgent need to revise the WHO recommendations for managing STIs in developing nations. Current studies have continued to show decreased specificity, sensitivity and positive predicative values for the vaginal discharge syndrome, and high rates of asymptomatic infections and healthcare workers neglecting to follow guidelines limit the usefulness of syndromic management. Furthermore, though advocate d as cost-effective by the WHO, there is a cost incurred from treating uninfected people. Instead of improving this system, it is recommended that better and less expensive point of care and the development of rapid test diagnosis kits be the focus and method of diagnosis and treatment in developing nations for STI management. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Section "A": Dissecting and Post-Mortem Instruments Diagnostic Instruments and Apparatus Microscopes and Microscopic Accessories Laboratory Apparatus and Glass Ware Apparatus for Blood and Urine Analysis Apparatus for Phlebotomy, Cupping and Leeching Apparatus for Infusion and Transfusion Syringes for Aspiration and Injection Osteological Preparations Section "B": Anaesthetic, General Operating, Osteotomy, Trepanning, Bullet, Pocket Case, Cautery, Ligatures, Sutures, Dressings, Etc. Section "B" continued Section "C": Eye, Ear, Nasal, Dermal, Oral, Tonsil, Tracheal, Laryngeal,Esophageal, Stomach, Intestinal, Gall Bladder Section "C": continued Section "D": Rectal, Phimosis, Prostatic, Vesical, Urethral, Ureteral, Instruments Section "E": Gynecic, Hysterectomy, Obstetrical, Instrument Satchels, Medicine Cases Section "F": Electric Cautery Transformers, Electro-Cautery Burners and Accessories, Electric Current Controllers, Electro-Diagnostic Outfits, Electrolysis Instruments Electro-Therapeutic Lamps, Faradic Batteries, Galvanic Batteries Section "G": Office Furniture, Office Sterilizing Apparatus, Hospital Supplies, Surgical Rubber Goods, Sick Room Utensils, Invalid Rolling Chairs, Invalid Supplies Section "H": Artificial Limbs, Deformity Apparatus, Fracture Apparatus, Splints, Splint Material, Elastic Hosiery, Abdominal Supporters, Crutches, Trusses, Suspensories, Etc. Index

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: analizar la experiencia obtenida y evaluar los resultados urodinámicos del estudio de 18 pacientes con esclerosis múltiple. Material y Métodos: se estudiaron 18 casos, valorándose la historia clínica, ecografía vesical y renal, analizándolos urodinámicamente con uroflujometría, residuo post miccional (RPM), cistotonometría y electromiografía esfinteriana. Urocultivo y antibiograma de orina. Resultados: del análisis de todas las variables se desprende que la vejiga hiperactiva se presentó en 10 casos con un predominio del síndrome frecuencia-urgencia, vejiga hipotónica-hiporrefléxica en 5 pacientes, disinergia detrusor-esfínter en 4 casos y 9 pacientes con infección urinaria que desencadenaban crisis de espasticidad. Todos fueron tratados con anticolinérgicos de acción vesical inmuno-modulación (brotes-recaídas) e inmuno-supresión en la enfermedad progresiva, de rehabilitación y terapia de apoyo psicológico. Conclusión: la vejiga hiperactiva es el tipo de consecuencia urinaria de la esclerosis en placa con los síntomas de frecuencia-urgencia y que, con tratamiento multimodal mejoran en un alto porcentaje.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An important competence of human data analysts is to interpret and explain the meaning of the results of data analysis to end-users. However, existing automatic solutions for intelligent data analysis provide limited help to interpret and communicate information to non-expert users. In this paper we present a general approach to generating explanatory descriptions about the meaning of quantitative sensor data. We propose a type of web application: a virtual newspaper with automatically generated news stories that describe the meaning of sensor data. This solution integrates a variety of techniques from intelligent data analysis into a web-based multimedia presentation system. We validated our approach in a real world problem and demonstrate its generality using data sets from several domains. Our experience shows that this solution can facilitate the use of sensor data by general users and, therefore, can increase the utility of sensor network infrastructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Facilitating general access to data from sensor networks (including traffic, hydrology and other domains) increases their utility. In this paper we argue that the journalistic metaphor can be effectively used to automatically generate multimedia presentations that help non-expert users analyze and understand sensor data. The journalistic layout and style are familiar to most users. Furthermore, the journalistic approach of ordering information from most general to most specific helps users obtain a high-level understanding while providing them the freedom to choose the depth of analysis to which they want to go. We describe the general characteristics and architectural requirements for an interactive intelligent user interface for exploring sensor data that uses the journalistic metaphor. We also describe our experience in developing this interface in real-world domains (e.g., hydrology).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, we have presented some studies concerning the analysis, design and optimization of one experimental device developed in the UK - GPTAD - which has been designed to remove blood clots without the need to make contact with the clot itself, thereby potentially reducing the risk of problems such as downstream embolisation. Based on the idea of a modification of the previous device, in this work, we present a model based in the use of stents like the SolitaireTM FR, which is in contact with the clot itself. In the case of such devices, the stent is self-expandable and the extraction of the blood clot is faciliatated by the stent, which must be inside the clot. Such stents are generally inserted in position by using the guidewire inserted into the catheter. This type of modeling could potentially be useful in showing how the blood clot is moved by the various different forces involved. The modelling has been undertaken by analyzing the resistances, compliances and inertances effects. We model an artery and blood clot for range of forces for the guidewire. In each case we determine the interaction between blood clot, stent and artery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article we describe a method for automatically generating text summaries of data corresponding to traces of spatial movement in geographical areas. The method can help humans to understand large data streams, such as the amounts of GPS data recorded by a variety of sensors in mobile phones, cars, etc. We describe the knowledge representations we designed for our method and the main components of our method for generating the summaries: a discourse planner, an abstraction module and a text generator. We also present evaluation results that show the ability of our method to generate certain types of geospatial and temporal descriptions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effective data summarization methods that use AI techniques can help humans understand large sets of data. In this paper, we describe a knowledge-based method for automatically generating summaries of geospatial and temporal data, i.e. data with geographical and temporal references. The method is useful for summarizing data streams, such as GPS traces and traffic information, that are becoming more prevalent with the increasing use of sensors in computing devices. The method presented here is an initial architecture for our ongoing research in this domain. In this paper we describe the data representations we have designed for our method, our implementations of components to perform data abstraction and natural language generation. We also discuss evaluation results that show the ability of our method to generate certain types of geospatial and temporal descriptions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern sensor technologies and simulators applied to large and complex dynamic systems (such as road traffic networks, sets of river channels, etc.) produce large amounts of behavior data that are difficult for users to interpret and analyze. Software tools that generate presentations combining text and graphics can help users understand this data. In this paper we describe the results of our research on automatic multimedia presentation generation (including text, graphics, maps, images, etc.) for interactive exploration of behavior datasets. We designed a novel user interface that combines automatically generated text and graphical resources. We describe the general knowledge-based design of our presentation generation tool. We also present applications that we developed to validate the method, and a comparison with related work.