809 resultados para misure sperimentali localizzazione indoor ranging reti wireless
Resumo:
The relative contribution of the main mechanisms that control indoor air quality in residential flats was examined. Indoor and outdoor concentration measurements of different type pollutants (black carbon, SO2, O3, NO, NO2,) were monitored in three naturally ventilated residential flats in Athens, Greece. At each apartment, experiments were conducted during the cold as well as during the warm period of the year. The controlling parameters of transport and deposition mechanisms were calculated from the experimental data. Deposition rates of the same pollutant differ according to the site (different construction characteristics) and to the measuring period for the same site (variations in relative humidity and differences in furnishing). Differences in the black carbon deposition rates were attributed to different black carbon size distributions. The highest deposition rates were observed for O3 in the residential flats with the older construction and the highest humidity levels. The calculated parameters as well as the measured outdoor concentrations were used as input data of a one-compartment indoor air quality model, and the indoor concentrations, the production, and loss rates of the different pollutants were calculated. The model calculated concentrations are in good agreement with the measured values. Model simulations revealed that the mechanism that mainly affected the change rate of indoor black carbon concentrations was the transport from the outdoor environment, while the removal due to deposition was insignificant. During model simulations, it was also established that that the change rate of SO2 concentrations was governed by the interaction between the transport and the deposition mechanisms while NOX concentrations were mainly controlled through photochemical reactions and the transport from outdoors.
Resumo:
Three-dimensional computational simulations are performed to examine indoor environment and micro-environment around human bodies in an office in terms of thermal environment and air quality. In this study, personal displacement ventilation (PDV), including two cases with all seats taken and two middle seats taken, is compared with overall displacement ventilation (ODV) of all seats taken under the condition that supply temperature is 24℃ and air change rate is 60 l/s per workstation. When using PDV, temperature stratification, the characteristic of displacement ventilation, is obviously observed at the position of occupant’s head and clearer in the case with all seats taken. Verticalertical ertical temperature temperature temperature temperature temperature differences below height of the head areare under under under 2℃ in two cases in two cases in two cases in two cases in two cases in two cases in two cases in two cases with all seats taken,and the temperature with PDV is higher than that with ODV. Verticalertical ertical temperature temperature temperature temperature temperature temperature difference is under 3 under 3under 3 under 3℃ in the case in the case in the case in the case in the case in the case in the case with two middle seats taken. CO2 concentration is lower th is lower th is lower this lower this lower than 2 g/man 2 g/m an 2 g/man 2 g/man 2 g/man 2 g/m 3 in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. in the breath zone. The results indicate that PDV can be used in the room with big change of occupants’ number to satisfy the need of thermal comfort and air quality. When not all seats are taken, designers should increase supply air requirement or reduce its temperature for thermal comfort. INDEX TERMS
Resumo:
An in vitro colon extended physiologically based extraction test (CEPBET) which incorporates human gastrointestinal tract (GIT) parameters (including pH and chemistry, solid-to-fluid ratio, mixing and emptying rates) was applied for the first time to study the bioaccessibility of brominated flame retardants (BFRs) from the 3 main GIT compartments (stomach, small intestine and colon) following ingestion of indoor dust. Results revealed the bioaccessibility of γ-HBCD (72%) was less than that for α- and β-isomers (92% and 80% respectively) which may be attributed to the lower aqueous solubility of the γ-isomer (2 μg L−1) compared to the α- and β-isomers (45 and 15 μg L−1 respectively). No significant change in the enantiomeric fractions of HBCDs was observed in any of the studied samples. However, this does not completely exclude the possibility of in vivo enantioselective absorption of HBCDs, as the GIT cell lining and bacterial flora – which may act enantioselectively – are not included in the current CE-PBET model. While TBBP-A was almost completely (94%) bioaccessible, BDE-209 was the least (14%) bioaccessible of the studied BFRs. Bioaccessibility of tri-hepta BDEs ranged from 32–58%. No decrease in the bioaccessibility with increasing level of bromination was observed in the studied PBDEs.
Resumo:
A resonant transmitter–receiver system is described for the wireless transmission of energy at a useful distance for grid-coordinate power and information. Experimental results are given showing delivery of power of an unmodified Tesla resonator contrasted with a modified version achieving improved efficiency over a 4 m range. A theoretical basis is provided to back up the experimental results obtained and to link the study with previous research in the field. A number of potential routes are suggested for further investigations and some possible applications of the technology are considered.
Resumo:
Power delivery for biomedical implants is a major consideration in their design for both measurement and stimulation. When performed by a wireless technique, transmission efficiency is critically important not only because of the costs associated with any losses but also because of the nature of those losses, for example, excessive heat can be uncomfortable for the individual involved. In this study, a method and means of wireless power transmission suitable for biomedical implants are both discussed and experimentally evaluated. The procedure initiated is comparable in size and simplicity to those methods already employed; however, some of Tesla’s fundamental ideas have been incorporated in order to obtain a significant improvement in efficiency. This study contains a theoretical basis for the approach taken; however, the emphasis here is on practical experimental analysis
Resumo:
Purpose – The purpose of this paper is to demonstrate key strategic decisions involved in turning around a large multinational operating in a dynamic market. Design/methodology/approach – The paper is based on analysis of archival documents and a semi-structured interview with the chairman of the company credited with its rescue. Findings – Turnaround is complex and involves both planned and emergent strategies. The progress is non-linear requiring adjustment and change in direction of travel. Top management credibility and vision is critical to success. Rescue is only possible if the company has a strong cash generative business among its businesses. The speed of decision making, decisiveness and the ability to implement strategy are among the key ingredients of success. Originality/value – Turnaround is an under-researched area in strategy. This paper contributes to a better understanding in this important area and bridges the gap between theory and practice. It provides a practical view and demonstrates how a leading executive with significant expertise and successful turnaround track record deals with inherent dilemmas of turnaround
Resumo:
Although early modern acting companies were adept at using different kinds of venue, performing indoors imposed a significant change in practice. Since indoor theatres required artificial lighting to augment the natural light admitted via windows, candles were employed; but the technology was such that candles could not last untended throughout an entire performance. Performing indoors thus introduced a new component into stage practice: the interval. This article explores what extant evidence (such as it is) might tell us about the introduction of act breaks, how they may have worked, and the implications for actors, audiences and dramatists. Ben Jonson's scripting of the interval in two late plays, The Staple of News and The Magnetic Lady, is examined for what it may suggest about actual practice, and the ways in which the interval may have been considered integral to composition and performance is explored through a reading of Middleton and Rowley's The Changeling. The interval offered playwrights a form of structural punctuation, drawing attention to how acts ended and began; actors could use the space to bring on props for use in the next act; spectators might use the pause between acts to reflect on what had happened and, perhaps, anticipate what was to come; and stage-sitters, the evidence indicates, often took advantage of the hiatus in the play to assert their presence in the space to which all eyes naturally were drawn.
Resumo:
Capacity dimensioning is one of the key problems in wireless network planning. Analytical and simulation methods are usually used to pursue the accurate capacity dimensioning of wireless network. In this paper, an analytical capacity dimensioning method for WCDMA with high speed wireless link is proposed based on the analysis on relations among system performance and high speed wireless transmission technologies, such as H-ARQ, AMC and fast scheduling. It evaluates system capacity in closed-form expressions from link level and system level. Numerical results show that the proposed method can calculate link level and system level capacity for WCDMA system with HSDPA and HSUPA.
Resumo:
In many countries, high densities of domestic cats (Felis catus) are found in urban habitats where they have the potential to exert considerable predation pressure on their prey. However, little is known of the ranging behaviour of cats in the UK. Twenty cats in suburban Reading, UK, were fitted with GPS trackers to quantify movement patterns. Cats were monitored during the summer and winter for an average of 6.8 24 h periods per season. Mean daily area ranged (95 % MCP) was 1.94 ha. Including all fixes, mean maximum area ranged was 6.88 ha. These are broadly comparable to those observed in urban areas in other countries. Daily area ranged was not affected by the cat’s sex or the season, but was significantly larger at night than during the day. There was no relationship between area ranged and habitat availability. Taking available habitat into account, cat ranging area contained significantly more garden and other green space than urban habitats. If cats were shown to be negatively affecting prey populations, one mitigation option for consideration in housing developments proposed near important wildlife sites would be to incorporate a ‘buffer zone’ in which cat ownership was not permitted. Absolute maximum daily area ranged by a cat in this study was 33.78 ha. This would correspond to an exclusory limit of approximately 300–400 m to minimise the negative effects of cat predation, but this may need to be larger if cat ranging behaviour is negatively affected by population density
Resumo:
Piglets can be reared under a variety of conditions ranging from outdoor, organic farms to high intensity, indoor facilities which use prophylactic antibiotics and everything in between. Do these different early-life influences matter when it comes to longer-term health and productivity?
Resumo:
With a wide range of applications benefiting from dense network air temperature observations but with limitations of costs, existing siting guidelines and risk of damage to sensors, new methods are required to gain a high resolution understanding of the spatio-temporal patterns of urban meteorological phenomena such as the urban heat island or precision farming needs. With the launch of a new generation of low cost sensors it is possible to deploy a network to monitor air temperature at finer spatial resolutions. Here we investigate the Aginova Sentinel Micro (ASM) sensor with a bespoke radiation shield (together < US$150) which can provide secure near-real-time air temperature data to a server utilising existing (or user deployed) Wireless Fidelity (Wi-Fi) networks. This makes it ideally suited for deployment where wireless communications readily exist, notably urban areas. Assessment of the performance of the ASM relative to traceable standards in a water bath and atmospheric chamber show it to have good measurement accuracy with mean errors < ± 0.22 °C between -25 and 30 °C, with a time constant in ambient air of 110 ± 15 s. Subsequent field tests of it within the bespoke shield also had excellent performance (root-mean-square error = 0.13 °C) over a range of meteorological conditions relative to a traceable operational UK Met Office platinum resistance thermometer. These results indicate that the ASM and bespoke shield are more than fit-for-purpose for dense network deployment in urban areas at relatively low cost compared to existing observation techniques.
Resumo:
This paper provides a high-level overview of E-UTRAN interworking and interoperability with existing Third Generation Partnership Project (3GPP) and non-3GPP wireless networks. E-UTRAN access networks (LTE and LTE-A) are currently the latest technologies for 3GPP evolution specified in Release 8, 9 and beyond. These technologies promise higher throughputs and lower latency while also reducing the cost of delivering the services to fit with subscriber demands. 3GPP offers a direct transition path from the current 3GPP UTRAN/GERAN networks to LTE including seamless handover. E-UTRAN and other wireless networks interworking is an option that allows operators to maximize the life of their existing network components before a complete transition to truly 4G networks. Network convergence, backward compatibility and interpretability are regarded as the next major challenge in the evolution and the integration of mobile wireless communications. In this paper, interworking and interoperability between the E-UTRAN Evolved Packet Core (EPC) architecture and 3GPP, 3GPP2 and IEEE based networks are clearly explained. How the EPC is designed to deliver multimedia and facilitate interworking is also explained. Moreover, the seamless handover needed to perform this interworking efficiently is described briefly. This study showed that interoperability and interworking between existing networks and E-UTRAN are highly recommended as an interim solution before the transition to full 4G. Furthermore, wireless operators have to consider a clear interoperability and interworking plan for their existing networks before making a decision to migrate completely to LTE. Interworking provides not only communication between different wireless networks; in many scenarios it contributes to add technical enhancements to one or both environments.