888 resultados para hip arthritis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Approximately 20% JIA patients enters adulthood with clinically active disease and disabled, therefore work condition may be affected. Objectives To assess the prevalence of work disability among adult patients with JIA regularly attending a tertiary heumatology center and to determine possible associated risk factors. Methods This was a cross-sectional study that enrolled 43 JIA patients according to 2004 revised ILAR criteria. A questionnaire was developed in order to evaluate working status and labor activity: occupation, current/previous work, employment status and withdrawal rate were actively searched. Demographic data, JIA characteristics, clinical activity (DAS28>2.6), therapeutic intervention, comorbidities, physical activity, sedentarism (WHO definitions), functional class (1991 ACR criteria), HAQ and SF-36 were recorded. The prevalence of work disability was calculated using 95% confidence interval, and compared to all parameters; qualitative variables were analyzed using tests of association (chi-square test) and quantitative variables by Mann-Whitney or student test. Results Patients' mean age was 29+7.4 yrs (range 19-41) with mean JIA duration = 17.2+12.3 yrs (range 3-33); 63% were males and 37% females. JIA subtypes were 64% polyarticular, 11% oligoarticular, 9% systemic, 9% ERA, 2% extended oligoarticular, 2% psoriatic arthritis; 7% had uveitis. Serum RF was positive in 21% and ANA in 21%. The majority (72%, n = 31) of JIA patients were employed, whereas 28% (n = 12) were currently not working. In the latter group, 83% (10/12) were retired due to JIA related disability. Further analysis comparing those currently working vs. Those not working revealed similar age (25,3 yrs vs.29,5 yrs, p = 0,09). Although not significantly, most patients currently working had Poly onset JIA (22 vs. 6 p = 0,37), higher frequencies of good education level >12 yrs of school (31 vs.9, p = 0,38), functional class I (p = 0,96), practiced regular physical activity (9 vs. 0, p = 0,89), were singles (26 vs. 8, p = 0,15). Both groups had comparable HAQ and DAS 28 scores (0,62 vs. 0.59, p = 0,47 and 2,51 vs.2,07, p = 0,64) and similar arthroplasty rate (8 vs. 4, p = 0,427). Frequencies of hypertension (3 vs.1, p = 0,999), dyslipidemia (1 vs. 1, p = 0,125), diabetes (1 vs. 0 p = 0,999), depression (1 vs. 0, p = 0,999) and smokers (3 vs. 1, p = 0,99) were alike in both groups. Remarkably, employed patients had higher SF 36 mental health component (84.0 vs. 70.42, P = 0.01). Conclusion High prevalence of almost 1/3 work disability and of retirement due to disease related incapacity remain major problems for adult JIA individuals. We also identified worse mental health in employed patients indicating that further research is needed, in addition to intense affirmative disability actions in order to remove possible disabling barriers and to adapt restrictive environments for these patients. Moreover, enhanced strategies and policy for inclusion of JIA patients in the job market is urged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the northeast of Brazil, caprine arthritis-encephalitis (CAE) is one of the key reasons for herd productivity decreasing that result in considerable economic losses. A comparative study was carried out using computed radiography (CR), histological analysis (HA), and scanning electronic microscopy (SEM) of the joints of CAE infected and normal goats. Humerus head surface of positive animals presented reduced joint space, increased bone density, and signs of degenerative joint disease (DJD). The carpal joint presented no morphological alterations in CR in any of the animals studied. Tarsus joint was the most affected, characterized by severe DJD, absence of joint space, increased periarticular soft tissue density, edema, and bone sclerosis. Histological analysis showed chronic tissue lesions, complete loss of the surface zone, absence of proteoglycans in the transition and radial zones and destruction of the cartilage surface in the CAE positive animals. Analysis by SEM showed ulcerated lesions with irregular and folded patterns on the joint surface that distinguished the limits between areas of normal and affected cartilage. The morphological study of the joints of normal and CAE positive goats deepened understanding of the alteration in the tissue bioarchitecture of the most affected joints. The SEM finding sustained previous histological reports, similar to those found for rheumatoid arthritis, suggesting that the goat infected with CAE can be considered as a potential model for research in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aimed for an extended knowledge and understanding of young people in stigmatized areas and their construction of group identity. With a focus on Roma youths in Konik, Montenegro, and their involvement in hip-hop we wanted to explore what this culture meant to them in relation to their context. An ethnographic approach was used in collecting the empirical data through observations, interpreting music lyrics and conducting qualitative semi-structured interviews. Five young Roma boys from Konik, all involved in hip-hop, were interviewed. Theoretical perspectives on identity, youth culture and stigmatization were central. In addition, Bourdieu’s theory regarding cultural capital was emphasized and connected to youths and hip-hop. The empirical material showed that involvement in hip-hop provided the Roma youths with a group identity that they referred to in positive terms. Contextual factors of stigmatization excluded the Roma group from the majority population and the engagement in hip-hop created a possibility for the youths to be someone. The cultural capital gained through hip-hop was not used to verify and legitimate an authentic Roma identity. It was rather a way for them to create boundaries towards the negative elements in their community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Immunisierung von Mäusen bestimmter Stämme (z.B. DBA/1) mit Kollagen-Typ-II (CII) führt zu Gelenkentzündungen, die in ihrem Verlauf der Rheumatoiden Arthritis beim Menschen ähnlich sind. Viele Untersuchungen deuten darauf hin, daß vor allem TH1-Zellen entscheidend an der Entstehung einer CIA beteiligt sind. In diesem Zusammenhang ist IL-12, das an der Induktion der TH1-Zellantwort beteiligt ist, von herausragender Bedeutung. Zur Klärung der Funktion von IL-12 wurde ein IL-12-Antagonist, (IL-12(p40)2), der aus einem Homodimer der IL-12p40-Kette besteht, in vivo eingesetzt. DBA/1-Mäuse, die transgen für die T-Zellrezeptor ß-Kette eines CII-spezifischen, arthritogenen T-Zellklons sind und infolge dessen eine CIA mit 100%-iger Inzidenz, frühem Auftreten und einem schweren chronischen Verlauf entwickeln, wurden mit IL-12(p40)2 behandelt. Die Behandlung von TCR-ßtg-Mäusen mit IL-12(p40)2 verzögerte die Entwicklung einer CIA und führte zu deutlich abgeschwächten Krankheitssymptomen, konnte aber nicht die Induktion einer CIA verhindern. Darüber hinaus produzierten die Milzzellen der IL-12(p40)2-behandelten Gruppe nach einer Stimulation mit CII geringere Menge an IFN-g, verglichen mit Kontrollgruppe. Somit resultiert aus einer in vivo Neutralisation von IL-12 eine supprimierte Entwicklung von CII-spezifischen TH1-Zellen. Diese Ergebnisse lassen darauf schließen, daß endogen gebildetes IL-12 bei der Induktion einer CIA eine wichtige Rolle spielt, indem es die Differenzierung von TH1-Zellen fördert und die Produktion von IFN-g steigert. Hinsichtlich der Funktion von IFN-g bei der CIA gibt es allerdings widersprüchliche Befunde. Zur Klärung der Funktion von IFN-g wurden die TCR-ßtg-Mäuse mit Mäusen gekreuzt, die defizient für die Produktion von IFN-g (IFN-g KO) sind. Es zeigte sich, daß keine der verwendeten F2 (IFN-g KO, TCR-ßtg)-Mäuse nach Immunisierung Symptome einer CIA entwickelten. Somit scheint IFN-g essentiell für die Entstehung einer CIA zu sein. Unerwarteterweise führte aber auch die Behandlung mit IL-12 von F2 (IFN-g KO,TCR-ßtg)-Mäusen in 50% der Tiere zur Entwicklung einer CIA. Da solche Mäuse kein IFN-g bilden können, kann IL-12 auch unabhängig von IFN-g die Induktion einer CIA vermitteln. IL-12 scheint somit eine zweifache Bedeutung bei der Entstehung einer CIA zuzukommen, zum einen als direkter Induktor, wie am Beispiel der F2 (IFN-g KO, TCR-ßtg)-Mäuse nachgewiesen wurde, und zum anderen als starker Promoter der IFN-g-Bildung in normalen Mäusen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An der Entwicklung und Aufrechterhaltung chronisch-inflammatorischer Erkrankungen wie der rheumatoiden Arthritis (RA) ist die Fehlregulation verschiedener pro-inflammatorischer Gene von entscheidender Bedeutung. Bei der RA führt unter anderem eine erhöhte Expression der induzierbaren NO-Synthase (iNOS) zu einer gesteigerten NO-Produktion, was schließlich zum Knochenabbau beiträgt. Für eine Therapie der RA werden häufig Glukokortikoide eingesetzt, die jedoch viele Nebenwirkungen zeigen. Um eine mögliche Therapiealternative zu identifizieren, sollten die Effekte des anti-inflammatorisch wirksamen Pilzmetaboliten S-Curvularin in verschiedenen Modellen der RA analysiert werden.rnIn humanen C-28/I2-Chondrozyten als in vitro-Modell der RA führte die Inkubation mit einem Zytokingemisch zu einer Induktion der iNOS-Expression, die vom chondrogenen Differenzierungsgrad der Zellen abhängig war. Entscheidend für die iNOS-Induktion in C-28/I2-Zellen ist hauptsächlich der p38-MAPK-, der JAK-STAT- und der NF-kappa B-Signaltransduktionsweg. Eine Inkubation der Zellen mit S-Curvularin führte zu einer deutlichen Hemmung der iNOS-Expression. Dexamethason hatte hingegen keinen Effekt auf die iNOS-Expression, was vermutlich auf die fehlende Expression der Glukokortikoidrezeptor-mRNA zurückgeführt werden kann. Daher können von S-Curvularin abgeleitete Pharmaka möglicherweise auch in Fällen einer Steroidresistenz zur Therapie von RA-Patienten zum Einsatz kommen.rnIm Tiermodell der Kollagen-induzierten Arthritis konnte die anti-inflammatorische Wirkung von S-Curvularin auf mehreren Ebenen bestätigt werden. Die Pilzsubstanz reduzierte sowohl die Schwellung der Pfoten als auch die Expression CII-induzierter pro-inflammatorischer Gene, wie z.B. S100A8, Defb6, Camp und Mpo. Dabei waren die Effekte von S-Curvularin meist deutlicher als in Dexamethason-behandelten Mäusen. Die Analyse von Zytokinen (z.B. TNF-alpha, IL-1beta) und Chemokinen (z.B. MCP-1, MIP-1alpha) zeigte, dass die CII-induzierte Expression dieser pro-inflammatorischen Mediatoren in den Pfoten der Mäuse durch eine Therapie mit S-Curvularin und Dexamethason wieder reduziert werden konnte, wobei Unterschiede zwischen den Behandlungen beobachtet werden konnte.rnAuch im Tiermodell der LPS-induzierten akuten Entzündung wurde die iNOS- und die S100A8-Expression in verschiedenen Geweben S-Curvularin reduziert. rnrnS-Curvularin ist also in der Lage, in verschiedenen Modellen der RA und im akuten Entzündungsmodell die pro-inflammatorische Genexpression effizient zu hemmen und könnte somit in Zukunft eine Rolle in der Therapie der RA einnehmen.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'elaborato prende in esame i fattori che hanno portato allo sviluppo del rap e dell'hip-hop in Russia, prendendo in esame i principali esponenti del genere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erhöhte arteriosklerotische und thrombotische Vorfälle sind ein Hauptgrund für die gesteigerten Zahlen kardiovaskulärer Todesfälle von Patienten mit chronisch entzündlichen Erkrankungen wie der rheumatoiden Arthritis (RA). Diese erhöhte Mortalität ist nicht auf die traditionellen Risikofaktoren, wie Alter, Geschlecht, Bluthochdruck oder Diabetes zurückzuführen. Man nimmt an, dass die systemische Entzündung einen nicht-traditionellen Risikofaktor für die erhöhten kardiovaskulären Todesfälle von RA-Patienten darstellt. Da die derzeitige Behandlung der RA zum Teil schwere Nebenwirkungen zur Folge haben kann, war es das Ziel dieser Doktorarbeit, die Zusammenhänge zwischen RA und Arteriosklerose (AS) näher zu untersuchen, sowie die neue antiinflammatorische Substanz Galiellalacton (Gal) für die Behandlung der AS zu charakterisieren.rnIn dem chronisch inflammatorischen Tiermodell der TTP-defizienten Mäuse, dessenrnPhänotyp dem einer humanen RA-Erkrankung ähnelt, konnte eine verschlechterternEndothelfunktion, die als ein erstes Symptom einer erworbenen AS gilt, nachgewiesen werden. Dies konnte auf eine erhöhte Stabilität der Nox2-mRNA zurückgeführt werden, die unabhängig von der erhöhten Expression des Entzündungsmarkers TNFα war. Diese gesteigerte Nox2-Menge führte wiederum zu einer erhöhten Bildung von reaktiven Sauerstoff- und Stickstoffspezies und somit zu einer verringerten Menge an bioaktivem Stickstoffmonoxid, welches die endotheliale Dysfunktion (eDF) bedingte.rnAls ein traditioneller Risikofaktor für das Auftreten von kardiovaskulären Ereignissen gilt unter anderem eine Diabeteserkrankung. Durch die Ausbildung einer Nitrattoleranz bei der Therapie mit organischen Nitraten wie NTG, ISMN oder ISDN kommt es zu der Entwicklung einer eDF. PETN, ein weiteres organisches Nitrat zeigt diese Nebenwirkung nicht. PETN, vermittelt seinen antioxidativen Effekt über die Nrf2-abhängige Induktion der HO-1-Promotoraktivität.rnDie Behandlung von arteriosklerotischen Mäusen (ApoE-/-- und ApoE-/-TFPI+/--Mäuse) mit dem antiinflammatorischen Pilzsekundärmetaboliten Gal zeigte eine verringerte mRNA-Expression von arteriosklerotischen und inflammatorischen Mediatoren, sowie eine reduzierte Thrombenbildung durch eine verringerte Plättchenadhäsion.rnZusammenfassend konnte gezeigt werden, dass inflammationsabhängiger oxidativerrnStress ein Hauptgrund für die entzündungsgetriebene Artheriogenese ist und Galrneine neue Leitsubstanz für die Behandlung dieser Erkrankung ist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays the number of hip joints arthroplasty operations continues to increase because the elderly population is growing. Moreover, the global life expectancy is increasing and people adopt a more active way of life. For this reasons, the demand of implant revision operations is becoming more frequent. The operation procedure includes the surgical removal of the old implant and its substitution with a new one. Every time a new implant is inserted, it generates an alteration in the internal femur strain distribution, jeopardizing the remodeling process with the possibility of bone tissue loss. This is of major concern, particularly in the proximal Gruen zones, which are considered critical for implant stability and longevity. Today, different implant designs exist in the market; however there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. The aim of the study is to investigate the stress shielding effect generated by different implant design parameters on proximal femur, evaluating which ranges of those parameters lead to the most physiological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the language used in Beyoncé's song "***Flawless" and its thematics, including feminism, womanism, and the world of hip-hop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un'analisi cronologica della situazione politica e sociale della comunità Afroamericana negli Stati Uniti e di come questa abbia influenzato la nascita e lo sviluppo dell'hip hop come manifestazione culturale

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer. METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment. RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment hip IR in our population-based inception cohort study of young asymptomatic males. It was strongly correlated with standard clinical assessment of IR but was considerably more reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the impact of tumour necrosis factor α (TNFα) blockers on the presence of liver fibrosis in patients with rheumatoid arthritis (RA) and psoriatic arthritis (PsA) treated with methotrexate (MTX). Methods Participants were consecutive patients with RA and PsA who had undergone MTX treatment for at least 1 year ± TNF blockade for over 6 months. Liver fibrosis was assessed using non-invasive transient elastography (FibroScan). Regression models were used to compare FibroScan values of patients with RA and patients with PsA receiving TNFα blockers with those who were not. Results FibroScan assessments were performed on 51 patients with RA and 43 patients with PsA. Compared to patients with RA, those with PsA were predominantly young men, received lower cumulative dosages of MTX and exhibited a higher incidence of liver steatosis and hyperlipidaemia. An abnormal result was observed in 7.1% of the anti-TNFα-naïve and in 13% of the anti-TNFα-treated patients in the RA group and in 30% of the anti-TNFα-naïve and 4.3% of the anti-TNFα-treated patients in the PsA group (OR=0.11, 95% CI 0.02 to 0.98). Results of the PsA group were robust when adjusted for baseline characteristics. Conclusion The results suggest a protective effect of TNFα inhibitors against the development of liver fibrosis in patients with PsA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In a prospective study, we assessed if a diagnosis of osteoporosis and periodontitis could predict hip and hand fractures in older persons. Materials and methods: Bone density was assessed by a Densitometer. Periodontitis was defined by evidence of alveolar bone loss. Results: 788 Caucasians (52.4% women, overall mean age: 76 years, S.D. +/- 9.0, range: 62 to 96) were enrolled and 7.4% had a hip/hand fracture in 3 years. Calcaneus PIXI T-values < - 1.6 identified osteoporosis in 28.2% of the older persons predicting a hip/hand fracture with an odds ratio of 3.3:1 (95% CI: 1.9, 5.7, p < 0.001). Older persons with osteoporosis had more severe periodontitis (p < 0.01). Periodontitis defined by >= 30% of sites with >= 5 mm distance between the cemento-enamel junction (CEJ) and bone level (ABL) was found in 18.7% of the older persons predicting a hip/hand fracture with an odds ratio of 1.8:1 (95% CI: 1.0, 3.3, p < 0.05). Adjusted for age, the odds ratio of a hip/hand fracture in older persons with osteoporosis (PIXI T-value <-2.5) and periodontitis was 12.2:1 (95% CI: 3.5, 42.3, p < 0.001). Conclusions: Older persons with osteoporosis and periodontitis have an increased risk for hip/hand fractures