934 resultados para high performance pilots


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lipid peroxidation (LPO) has been associated with periodontal disease, and the evaluation of malondialdehyde (MDA) in the gingival crevicular fluid (GCF), an inflammatory exudate from the surrounding tissue of the periodontium, may be useful to clarify the role of LPO in the pathogenesis of periodontal disease. We describe the validation of a method to measure MDA in the GCF using high-performance liquid chromatography. MDA calibration curves were prepared with phosphate-buffered solution spiked with increasing known concentrations of MDA. Healthy and diseased GCF samples were collected from the same patient to avoid interindividual variability. MDA response was linear in the range measured, and excellent agreement was observed between added and detected concentrations of MDA. Samples' intra- and interday coefficients of variation were below 6.3% and 12.4%, respectively. The limit of quantitation (signal/noise = 5) was 0.03 mu M. When the validated method was applied to the GCF, excellent agreement was observed in the MDA quantitation from healthy and diseased sites, and diseased sites presented more MDA than healthy sites (P < 0.05). In this study, a validated method for MDA quantitation in GCF was established with satisfactory sensitivity, precision, and accuracy. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DEVELOPMENT AND VALIDATION OF AN ANALYTICAL METHOD FOR QUANTITATION OF THE DRUG BEVACIZUMAB BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY. In this study, an analytical method was developed and validated for quantitation of the drug bevacizumab (Avastin (R)) by high performance liquid chromatography (HPLC). The HPLC column was a BioSuite 250 (R) HR SEC, 300 x 7.8 mm x 5 mu m (Waters, USA). The mobile phase consisted of phosphate buffered saline (PBS). The results revealed that the method was specific, precise. accurate, robust and linear (r(2) = 0.998) from 5 to 75 mu g mL(-1). Therefore, this method can be used in drug release studies or in quality control ampoules of the drug.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Implementing precise techniques in routine diagnosis of chronic granulomatous disease (CGD), which expedite the screening of molecular defects, may be critical for a quick assumption of patient prognosis. This study compared the efficacy of single-strand conformation polymorphism analysis (SSCP) and high-performance liquid chromatography under partially denaturing conditions (dHPLC) for screening mutations in CGD patients. We selected 10 male CGD patients with a clinical history of severe recurrent infections and abnormal respiratory burst function. gDNA, mRNA and cDNA samples were prepared by standard methods. CYBB exons were amplified by PCR and screened by SSCP or dHPLC. Abnormal DNA fragments were sequenced to reveal the nature of the mutations. The SSCP and dHPLC methods showed DNA abnormalities, respectively, in 55% and 100% of the cases. Sequencing of the abnormal DNA samples confirmed mutations in all cases. Four novel mutations in CYBB were identified which were picked up only by the dHPLC screening (c.904 insC, c.141+5 g>t, c.553 T>C, and c.665 A>T). This work highlights the relevance of dHPLC, a sensitive, fast, reliable and cost-effective method for screening mutations in CGD, which in combination with functional assays assessing the phagocyte respiratory burst will contribute to expedite the definitive diagnosis of X-linked CGD, direct treatment, genetic counselling and to have a clear assumption of the prognosis. This strategy is especially suitable for developing countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Styrax camporum Pohl, known in Brazil as estoraque do campo or cuia de brejo, has been used in the treatment of gastrointestinal diseases. The therapeutic action of S. camporum has been attributed to the ethyl acetate fraction, although the chemical composition of this fraction has not yet been analyzed. In this study, a high-performance liquid chromatography photodiode array detection (HPLC-PAD) method for analysis of Brazilian Styrax species has been developed. The compounds egonol (1) and homoegonol (2) were found to be present in all the samples investigated by HPLC. These compounds were isolated by open column chromatography followed by preparative TLC, and were identified by 1H NMR. Compounds 1 and 2 were thus proposed as phytochemical markers for Styrax, owing to their biological properties and presence in other Styrax species. The developed method has been validated and successfully applied for quantification of 1 and 2 in S. camporum dried leaves and crude ethanolic extracts from S. ferrugineus and S. pohlii aerial parts. Copyright (c) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents simple, rapid, precise and accurate stability-indicating HPLC and CE methods, which were developed and validated for the determination of nitrendipine, nimodipine and nisoldipine. These drugs are calcium channel antagonists of the 1,4-dihydropyridine type which are used in the treatment of cardiovascular diseases. Experimental results showed a good linear correlation between the area and the concentration of drugs covering a relatively large domain of concentration in all cases. The linearity of the analytical procedures was in the range of 2.0-120.0 mu g mL-1 for nitrendipine, 1.0-100.0 mu g mL(-1) for nimodipine and 100.0-600.0 mu g mL(-1) for nisoldipine, the regression determination coefficient being higher than 0.99 in all cases. The proposed methods were found to have good precision and accuracy. The chemical stability of these drugs was determined under various conditions and the methods have shown adequate separation for their enantiomers and degradation products. In addition, degradation products produced as a result of stress studies did not interfere with the detection of the drugs' enantiomers and the assays can thus be considered stability-indicating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Breakthrough advances in microprocessor technology and efficient power management have altered the course of development of processors with the emergence of multi-core processor technology, in order to bring higher level of processing. The utilization of many-core technology has boosted computing power provided by cluster of workstations or SMPs, providing large computational power at an affordable cost using solely commodity components. Different implementations of message-passing libraries and system softwares (including Operating Systems) are installed in such cluster and multi-cluster computing systems. In order to guarantee correct execution of message-passing parallel applications in a computing environment other than that originally the parallel application was developed, review of the application code is needed. In this paper, a hybrid communication interfacing strategy is proposed, to execute a parallel application in a group of computing nodes belonging to different clusters or multi-clusters (computing systems may be running different operating systems and MPI implementations), interconnected with public or private IP addresses, and responding interchangeably to user execution requests. Experimental results demonstrate the feasibility of this proposed strategy and its effectiveness, through the execution of benchmarking parallel applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resistance to corrosion, high tensile strength, low weight, easiness and rapidity of application, are characteristics that have contributed to the spread of the strengthening technique characterized by bonding of carbon fibers reinforced polymer (CFRP). This research aimed to develop an innovate strengthening method for RC beams, based on a high performance cement-based composite of steel fibers (macro + microfibers) to be applied as a transition layer. The purpose of this transition layer is better control the cracking of concrete and detain or even avoid premature debonding of strengthening. A preliminary study in short beams molded with steel fibers and strengthened with CFRP sheet, was carried out where was verified that the conception of the transition layer is valid. Tests were developed to get a cement-based composite with adequate characteristics to constitute the layer transition. Results showed the possibility to develop a high performance material with a pseudo strain-hardening behavior, high strength and fracture toughness. The application of the strengthening on the transition layer surface had significantly to improve the performance levels of the strengthened beam. It summary, it was proven the efficiency of the new strengthening technique, and much information can be used as criteria of projects for repaired and strengthened structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need for high bandwidth, due to the explosion of new multi\-media-oriented IP-based services, as well as increasing broadband access requirements is leading to the need of flexible and highly reconfigurable optical networks. While transmission bandwidth does not represent a limit due to the huge bandwidth provided by optical fibers and Dense Wavelength Division Multiplexing (DWDM) technology, the electronic switching nodes in the core of the network represent the bottleneck in terms of speed and capacity for the overall network. For this reason DWDM technology must be exploited not only for data transport but also for switching operations. In this Ph.D. thesis solutions for photonic packet switches, a flexible alternative with respect to circuit-switched optical networks are proposed. In particular solutions based on devices and components that are expected to mature in the near future are proposed, with the aim to limit the employment of complex components. The work presented here is the result of part of the research activities performed by the Networks Research Group at the Department of Electronics, Computer Science and Systems (DEIS) of the University of Bologna, Italy. In particular, the work on optical packet switching has been carried on within three relevant research projects: the e-Photon/ONe and e-Photon/ONe+ projects, funded by the European Union in the Sixth Framework Programme, and the national project OSATE funded by the Italian Ministry of Education, University and Scientific Research. The rest of the work is organized as follows. Chapter 1 gives a brief introduction to network context and contention resolution in photonic packet switches. Chapter 2 presents different strategies for contention resolution in wavelength domain. Chapter 3 illustrates a possible implementation of one of the schemes proposed in chapter 2. Then, chapter 4 presents multi-fiber switches, which employ jointly wavelength and space domains to solve contention. Chapter 5 shows buffered switches, to solve contention in time domain besides wavelength domain. Finally chapter 6 presents a cost model to compare different switch architectures in terms of cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aufbau einer kontinuierlichen, mehrdimensionalen Hochleistungs-flüssigchromatographie-Anlage für die Trennung von Proteinen und Peptiden mit integrierter größenselektiver ProbenfraktionierungEs wurde eine mehrdimensionale HPLC-Trennmethode für Proteine und Peptide mit einem Molekulargewicht von <15 kDa entwickelt.Im ersten Schritt werden die Zielanalyte von höhermolekularen sowie nicht ionischen Bestandteilen mit Hilfe von 'Restricted Access Materialien' (RAM) mit Ionenaustauscher-Funktionalität getrennt. Anschließend werden die Proteine auf einer analytischen Ionenaustauscher-Säule sowie auf Reversed-Phase-Säulen getrennt. Zur Vermeidung von Probenverlusten wurde ein kontinuierlich arbeitendes, voll automatisiertes System auf Basis unterschiedlicher Trenngeschwindigkeiten und vier parallelen RP-Säulen aufgebaut.Es werden jeweils zwei RP-Säulen gleichzeitig, jedoch mit zeitlich versetztem Beginn eluiert, um durch flache Gradienten ausreichende Trennleistungen zu erhalten. Während die dritte Säule regeneriert wird, erfolgt das Beladen der vierte Säule durch Anreicherung der Proteine und Peptide am Säulenkopf. Während der Gesamtanalysenzeit von 96 Minuten werden in Intervallen von 4 Minuten Fraktionen aus der 1. Dimension auf die RP-Säulen überführt und innerhalb von 8 Minuten getrennt, wobei 24 RP-Chromatogramme resultieren.Als Testsubstanzen wurden u.a. Standardproteine, Proteine und Peptide aus humanem Hämofiltrat sowie aus Lungenfibroblast-Zellkulturüberständen eingesetzt. Weiterhin wurden Fraktionen gesammelt und mittels MALDI-TOF Massenspektrometrie untersucht. Bei einer Injektion wurden in den 24 RP-Chromatogrammen mehr als 1000 Peaks aufgelöst. Der theoretische Wert der Peakkapazität liegt bei ungefähr 3000.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electronic applications are nowadays converging under the umbrella of the cloud computing vision. The future ecosystem of information and communication technology is going to integrate clouds of portable clients and embedded devices exchanging information, through the internet layer, with processing clusters of servers, data-centers and high performance computing systems. Even thus the whole society is waiting to embrace this revolution, there is a backside of the story. Portable devices require battery to work far from the power plugs and their storage capacity does not scale as the increasing power requirement does. At the other end processing clusters, such as data-centers and server farms, are build upon the integration of thousands multiprocessors. For each of them during the last decade the technology scaling has produced a dramatic increase in power density with significant spatial and temporal variability. This leads to power and temperature hot-spots, which may cause non-uniform ageing and accelerated chip failure. Nonetheless all the heat removed from the silicon translates in high cooling costs. Moreover trend in ICT carbon footprint shows that run-time power consumption of the all spectrum of devices accounts for a significant slice of entire world carbon emissions. This thesis work embrace the full ICT ecosystem and dynamic power consumption concerns by describing a set of new and promising system levels resource management techniques to reduce the power consumption and related issues for two corner cases: Mobile Devices and High Performance Computing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five different methods were critically examined to characterize the pore structure of the silica monoliths. The mesopore characterization was performed using: a) the classical BJH method of nitrogen sorption data, which showed overestimated values in the mesopore distribution and was improved by using the NLDFT method, b) the ISEC method implementing the PPM and PNM models, which were especially developed for monolithic silicas, that contrary to the particulate supports, demonstrate the two inflection points in the ISEC curve, enabling the calculation of pore connectivity, a measure for the mass transfer kinetics in the mesopore network, c) the mercury porosimetry using a new recommended mercury contact angle values. rnThe results of the characterization of mesopores of monolithic silica columns by the three methods indicated that all methods were useful with respect to the pore size distribution by volume, but only the ISEC method with implemented PPM and PNM models gave the average pore size and distribution based on the number average and the pore connectivity values.rnThe characterization of the flow-through pore was performed by two different methods: a) the mercury porosimetry, which was used not only for average flow-through pore value estimation, but also the assessment of entrapment. It was found that the mass transfer from the flow-through pores to mesopores was not hindered in case of small sized flow-through pores with a narrow distribution, b) the liquid penetration where the average flow-through pore values were obtained via existing equations and improved by the additional methods developed according to Hagen-Poiseuille rules. The result was that not the flow-through pore size influences the column bock pressure, but the surface area to volume ratio of silica skeleton is most decisive. Thus the monolith with lowest ratio values will be the most permeable. rnThe flow-through pore characterization results obtained by mercury porosimetry and liquid permeability were compared with the ones from imaging and image analysis. All named methods enable a reliable characterization of the flow-through pore diameters for the monolithic silica columns, but special care should be taken about the chosen theoretical model.rnThe measured pore characterization parameters were then linked with the mass transfer properties of monolithic silica columns. As indicated by the ISEC results, no restrictions in mass transfer resistance were noticed in mesopores due to their high connectivity. The mercury porosimetry results also gave evidence that no restrictions occur for mass transfer from flow-through pores to mesopores in the small scaled silica monoliths with narrow distribution. rnThe prediction of the optimum regimes of the pore structural parameters for the given target parameters in HPLC separations was performed. It was found that a low mass transfer resistance in the mesopore volume is achieved when the nominal diameter of the number average size distribution of the mesopores is appr. an order of magnitude larger that the molecular radius of the analyte. The effective diffusion coefficient of an analyte molecule in the mesopore volume is strongly dependent on the value of the nominal pore diameter of the number averaged pore size distribution. The mesopore size has to be adapted to the molecular size of the analyte, in particular for peptides and proteins. rnThe study on flow-through pores of silica monoliths demonstrated that the surface to volume of the skeletons ratio and external porosity are decisive for the column efficiency. The latter is independent from the flow-through pore diameter. The flow-through pore characteristics by direct and indirect approaches were assessed and theoretical column efficiency curves were derived. The study showed that next to the surface to volume ratio, the total porosity and its distribution of the flow-through pores and mesopores have a substantial effect on the column plate number, especially as the extent of adsorption increases. The column efficiency is increasing with decreasing flow through pore diameter, decreasing with external porosity, and increasing with total porosity. Though this tendency has a limit due to heterogeneity of the studied monolithic samples. We found that the maximum efficiency of the studied monolithic research columns could be reached at a skeleton diameter of ~ 0.5 µm. Furthermore when the intention is to maximize the column efficiency, more homogeneous monoliths should be prepared.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis deals with heterogeneous architectures in standard workstations. Heterogeneous architectures represent an appealing alternative to traditional supercomputers because they are based on commodity components fabricated in large quantities. Hence their price-performance ratio is unparalleled in the world of high performance computing (HPC). In particular, different aspects related to the performance and consumption of heterogeneous architectures have been explored. The thesis initially focuses on an efficient implementation of a parallel application, where the execution time is dominated by an high number of floating point instructions. Then the thesis touches the central problem of efficient management of power peaks in heterogeneous computing systems. Finally it discusses a memory-bounded problem, where the execution time is dominated by the memory latency. Specifically, the following main contributions have been carried out: A novel framework for the design and analysis of solar field for Central Receiver Systems (CRS) has been developed. The implementation based on desktop workstation equipped with multiple Graphics Processing Units (GPUs) is motivated by the need to have an accurate and fast simulation environment for studying mirror imperfection and non-planar geometries. Secondly, a power-aware scheduling algorithm on heterogeneous CPU-GPU architectures, based on an efficient distribution of the computing workload to the resources, has been realized. The scheduler manages the resources of several computing nodes with a view to reducing the peak power. The two main contributions of this work follow: the approach reduces the supply cost due to high peak power whilst having negligible impact on the parallelism of computational nodes. from another point of view the developed model allows designer to increase the number of cores without increasing the capacity of the power supply unit. Finally, an implementation for efficient graph exploration on reconfigurable architectures is presented. The purpose is to accelerate graph exploration, reducing the number of random memory accesses.