986 resultados para Rush Hour.
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.
Resumo:
Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.
Resumo:
Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.
Resumo:
Resumo I - O Relatório de estágio foi idealizado no âmbito da Unidade Curricular de Estágio do Ensino Especializado, Mestrado em Ensino da Música pela Escola Superior de Música de Lisboa. O documento incide sobre a prática pedagógica desenvolvida no Conservatório Regional de Palmela no ano letivo 2013/2014, abrangendo três alunos dos diferentes graus de ensino. No conteúdo do relatório, para além da caracterização do estabelecimento de ensino onde o estágio foi desenvolvido, foram caracterizados os diferentes alunos realçando as linhas pedagógicas seguidas com cada um dos intervenientes, salientando os aspetos de competências motora, auditiva e expressiva desenvolvidas durante o processo. Os objetivos do trabalho desenvolvido com os alunos é descrito, tendo como base a organização dos materiais a utilizar de acordo com as características de cada aluno, e consequentemente de acordo com a análise crítica da atividade docente. O professor tem a responsabilidade de conduzir o ensino dos alunos para que estes saibam apreciar e compreender as execuções musicais, independentemente da aptidão musical que já possuem.
Resumo:
Recensão crítica do livro "PONTES,J.; CASTRO, R. S. e AFONSO - A hora da liberdade: o 25 de Abril, pelos protagonistas = The hour of liberty: 25 april by its protagonists. Lisboa: Bizâncio, 2012”.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias da Saúde
Resumo:
OBJECTIVE: To assess the effect of a health promotion program on cardiometabolic risk profile in Japanese-Brazilians. METHODS: A total of 466 subjects from a study on diabetes prevalence conducted in the city of Bauru, southeastern Brazil, in 2000 completed a 1-year intervention program (2005-2006) based on healthy diet counseling and physical activity. Changes in blood pressure and metabolic parameters in the 2005-2006 period were compared with annual changes in these same variables in the 2000-2005 period. RESULTS: During the intervention, there were greater annual reductions in mean (SD) waist circumference [-0.5(3.8) vs. 1.2(1.2) cm per year, p<0.001], systolic blood pressure [-4.6(17.9) vs. 1.8(4.3) mmHg per year, p<0.001], 2-hour plasma glucose [-1.2(2.1) vs. -0.2(0.6) mmol/L per year, p<0.001], LDL-cholesterol [-0.3(0.9) vs. -0.1(0.2) mmol/L per year, p<0.001] and Framingham coronary heart disease risk score [-0.25(3.03) vs. 0.11(0.66) per year, p=0.02] but not in triglycerides [0.2(1.6) vs. 0.1(0.42) mmol/L per year, p<0.001], and fasting insulin level [1.2(5.8) vs. -0.7(2.2) IU/mL per year, p<0.001] compared with the pre-intervention period. Significant reductions in the prevalence of impaired fasting glucose/impaired glucose tolerance and diabetes were seen during the intervention (from 58.4% to 35.4%, p<0.001; and from 30.1% to 21.7%, p= 0.004, respectively). CONCLUSIONS: A one-year community-based health promotion program brings cardiometabolic benefits in a high-risk population of Japanese-Brazilians.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Environment monitoring has an important role in occupational exposure assessment. However, due to several factors is done with insufficient frequency and normally don´t give the necessary information to choose the most adequate safety measures to avoid or control exposure. Identifying all the tasks developed in each workplace and conducting a task-based exposure assessment help to refine the exposure characterization and reduce assessment errors. A task-based assessment can provide also a better evaluation of exposure variability, instead of assessing personal exposures using continuous 8-hour time weighted average measurements. Health effects related with exposure to particles have mainly been investigated with mass-measuring instruments or gravimetric analysis. However, more recently, there are some studies that support that size distribution and particle number concentration may have advantages over particle mass concentration for assessing the health effects of airborne particles. Several exposure assessments were performed in different occupational settings (bakery, grill house, cork industry and horse stable) and were applied these two resources: task-based exposure assessment and particle number concentration by size. The results showed interesting results: task-based approach applied permitted to identify the tasks with higher exposure to the smaller particles (0.3 μm) in the different occupational settings. The data obtained allow more concrete and effective risk assessment and the identification of priorities for safety investments.
Resumo:
OBJECTIVE To analyze the factors associated with the use of pacifiers and/or bottle feeding in infants aged under one year.METHODS This is a cross-sectional study with 34,366 children and using data from the database of the 2nd Nationwide Survey of Breastfeeding Prevalence performed in the Brazilian capitals and Federal District in 2008. Cluster sampling was used. The questionnaire included questions about the use of artificial nipples in the last 24 hours. The analysis considered three outcomes: exclusive use of pacifier, exclusive use of bottle feeding, and use of artificial nipples (pacifier and bottle feeding). Prevalence ratios were obtained using Poisson regression with robust variance following a hierarchical model.RESULTS The following factors were associated with exclusive use of the pacifier: mother working outside the home, primiparity, child was not breastfed within the first hour, and child had consumed tea on the first day at home. The following factors were associated with exclusive use of bottle feeding: mother working outside the home, primiparity, low birth weight, child not breastfed within the first hour, and child had consumed milk formula and tea on the first day at home. The following factors were associated with use of artificial nipples (pacifier and bottle feeding): mother working outside the home, primiparity, cesarean delivery, the male gender, low birth weight, born in a hospital not accredited as “baby friendly”, required health baby monitoring in the Primary Health Care Unit (PR = 0.91), and child had consumed milk formula, water, or tea on the first day at home.CONCLUSIONS This study identified profiles of exclusive users of pacifiers, bottle feeding, and both. The provided information can guide preventive practices for child health.
Resumo:
Mestrado em Fisioterapia
Resumo:
OBJECTIVE To assess the inequalities in access, utilization, and quality of health care services according to the socioeconomic status. METHODS This population-based cross-sectional study evaluated 2,927 individuals aged ≥ 20 years living in Pelotas, RS, Southern Brazil, in 2012. The associations between socioeconomic indicators and the following outcomes were evaluated: lack of access to health services, utilization of services, waiting period (in days) for assistance, and waiting time (in hours) in lines. We used Poisson regression for the crude and adjusted analyses. RESULTS The lack of access to health services was reported by 6.5% of the individuals who sought health care. The prevalence of use of health care services in the 30 days prior to the interview was 29.3%. Of these, 26.4% waited five days or more to receive care and 32.1% waited at least an hour in lines. Approximately 50.0% of the health care services were funded through the Unified Health System. The use of health care services was similar across socioeconomic groups. The lack of access to health care services and waiting time in lines were higher among individuals of lower economic status, even after adjusting for health care needs. The waiting period to receive care was higher among those with higher socioeconomic status. CONCLUSIONS Although no differences were observed in the use of health care services across socioeconomic groups, inequalities were evident in the access to and quality of these services.
Resumo:
Mestrado em Segurança e Higiene no Trabalho