951 resultados para Reproducibility
Resumo:
We have reported in a variety of mammalian cells the reversible formation of a filamentous actin (F-actin)-enriched aggresome generated by the actin toxin jasplakinolide (Lázaro-Diéguez et al., J Cell Sci 2008; 121:1415-25). Notably, this F-actin aggresome (FAG) resembles in many aspects the pathological Hirano body, which frequently appears in some diseases such as Alzheimer's and alcoholism. Using selective inhibitors, we examined the molecular and subcellular mechanisms that participate in the clearance of the FAG. Chaperones, microtubules, proteasomes and autophagosomes all actively participate to eliminate the FAG. Here we compile and compare these results and discuss the involvement of each process. Because of its simplicity and high reproducibility, our cellular model could help to test pharmacological agents designed to interfere with the mechanisms involved in the clearance of intracellular bodies and, in particular, of those enriched in F-actin.
Resumo:
RelA (NF-kappaB) is a transcription factor inducible by distinct stimuli in many different cell types. To find new cell type specific cofactors of NF-kappaB dependent transcription, we isolated RelA transcription activation domain binding proteins from the nuclear extracts of three different cell types. Analysis by electrophoresis and liquid chromatography tandem mass spectrometry identified several novel putative molecular partners. Some were strongly enriched in the complex formed from the nuclear extracts of specific cell types.
Resumo:
OBJECTIVES: Elevated plasma levels of the elastase alpha 1-proteinase inhibitor complex (E-alpha 1 PI) have been proposed as a marker of bacterial infection and neutrophil activation. Liberation of elastase from neutrophils after collection of blood may cause falsely elevated results. Collection methods have not been validated for critically ill neonates and children. We evaluated the influence of preanalytical methods on E-alpha 1 PI results including the recommended collection into EDTA tubes. DESIGN AND METHODS: First, we compared varying acceleration speeds and centrifugation times. Centrifugation at 1550 g for 3 min resulted in reliable preparation of leukocyte free plasma. Second, we evaluated all collection tubes under consideration for absorption of E-alpha 1 PI. Finally, 12 sets of samples from healthy adults and 42 sets obtained from critically ill neonates and children were distributed into the various sampling tubes. Samples were centrifuged within 15 min of collection and analyzed with a new turbidimetric assay adapted to routine laboratory analyzers. RESULTS: One of the two tubes containing a plasma-cell separation gel absorbed 22.1% of the E-alpha 1 PI content. In the remaining tubes without absorption of E-alpha 1 PI no differences were observed for samples from healthy adult patients. However, in samples from critically ill neonates or children, significantly higher results were obtained for plain Li-heparin tubes (mean = 183 micrograms/L), EDTA tubes (mean = 93 micrograms/L), and citrate tubes (mean = 88.5 micrograms/L) than for the Li-hep tube with cell-plasma separation gel and no absorption of E-alpha 1 PI (mean = 62.4 micrograms/L, p < 0.01). CONCLUSION: Contrary to healthy adults, E-alpha 1 PI results in plasma samples from critically ill neonates and children depend on the type of collection tube.
Resumo:
The genetic determinants and phenotypic traits which make a Staphylococcus aureus strain a successful colonizer are largely unknown. The genetic diversity and population structure of 133 S. aureus isolates from healthy, generally risk-free adult carriers were investigated using four different typing methods: multilocus sequence typing (MLST), amplified fragment length polymorphism analysis (AFLP), double-locus sequence typing (DLST), and spa typing were compared. Carriage isolates displayed great genetic diversity which could only be revealed fully by DLST. Results of AFLP and MLST were highly concordant in the delineation of genotypic clusters of closely related isolates, roughly equivalent to clonal complexes. spa typing and DLST provided considerably less phylogenetic information. The resolution of spa typing was similar to that of AFLP and inferior to that of DLST. AFLP proved to be the most universal method, combining a phylogeny-building capacity similar to that of MLST with a much higher resolution. However, it had a lower reproducibility than sequencing-based MLST, DLST, and spa typing. We found two cases of methicillin-resistant S. aureus colonization, both of which were most likely associated with employment at a health service. Of 21 genotypic clusters detected, 2 were most prevalent: cluster 45 and cluster 30 each colonized 24% of the carrier population. The number of bacteria found in nasal samples varied significantly among the clusters, but the most prevalent clusters were not particularly numerous in the nasal samples. We did not find much evidence that genotypic clusters were associated with different carrier characteristics, such as age, sex, medical conditions, or antibiotic use. This may provide empirical support for the idea that genetic clusters in bacteria are maintained in the absence of adaptation to different niches. Alternatively, carrier characteristics other than those evaluated here or factors other than human hosts may exert selective pressure maintaining genotypic clusters.
Resumo:
While developing a high-pressure liquid chromatography assay for cefepime in plasma, we observed significant drug degradation at 20 and 37 degrees C but not at 4 degrees C. This plasma-related degradation persisted after protein removal. This warrants caution regarding cefepime assays for pharmacokinetic and pharmacodynamic studies of cefepime in vitro and in vivo.
Resumo:
BACKGROUND: An elevated early (E) to late (A) diastolic filling velocities ratio, typically seen in advanced diastolic dysfunction, has also been observed after cardioversion of atrial fibrillation as a consequence of the depressed left atrial (LA) contractility. We hypothesized that the impaired LA contractile function demonstrated after orthotopic cardiac transplantation (OCT) could also lead to this "pseudorestrictive" pattern. METHOD: E/A ratio related to the tissue Doppler early mitral annular velocity (Ea) as preload-independent index of LV relaxation was evaluated in all consecutive OCT patients between 2005 and 2007. RESULTS: The study population comprised 48 patients 97 ± 77 months after OCT. Thirty-two patients (67%) had an E/A ratio > 2. LV systolic function and myocardial relaxation assessed by the Ea velocity were similar compared to patients with normal ratio (61 ± 6% vs. 60 ± 12%, P = 0.854 and 15 ± 4 cm/s vs. 14 ± 3 cm/s, r = 0.15, P = 0.323, respectively). On the other hand, the proportion of the recipient and donor LA cuffs as estimated by the recipient/global LA area ratio and the LA emptying fraction significantly correlated with the E/A ratio (r = 0.40, P = 0.005 and r =-0.33, P = 0.022, respectively). CONCLUSION: Our study shows that there is a high prevalence of elevated E/A ratio after standard OCT which seems mainly related to reduced LA contractility. Recognition of this "pseudorestrictive" pattern may avoid misdiagnosis of diastolic dysfunction.
Resumo:
Short-TE MRS has been proposed recently as a method for the in vivo detection and quantification of γ-aminobutyric acid (GABA) in the human brain at 3 T. In this study, we investigated the accuracy and reproducibility of short-TE MRS measurements of GABA at 3 T using both simulations and experiments. LCModel analysis was performed on a large number of simulated spectra with known metabolite input concentrations. Simulated spectra were generated using a range of spectral linewidths and signal-to-noise ratios to investigate the effect of varying experimental conditions, and analyses were performed using two different baseline models to investigate the effect of an inaccurate baseline model on GABA quantification. The results of these analyses indicated that, under experimental conditions corresponding to those typically observed in the occipital cortex, GABA concentration estimates are reproducible (mean reproducibility error, <20%), even when an incorrect baseline model is used. However, simulations indicate that the accuracy of GABA concentration estimates depends strongly on the experimental conditions (linewidth and signal-to-noise ratio). In addition to simulations, in vivo GABA measurements were performed using both spectral editing and short-TE MRS in the occipital cortex of 14 healthy volunteers. Short-TE MRS measurements of GABA exhibited a significant positive correlation with edited GABA measurements (R = 0.58, p < 0.05), suggesting that short-TE measurements of GABA correspond well with measurements made using spectral editing techniques. Finally, within-session reproducibility was assessed in the same 14 subjects using four consecutive short-TE GABA measurements in the occipital cortex. Across all subjects, the average coefficient of variation of these four GABA measurements was 8.7 ± 4.9%. This study demonstrates that, under some experimental conditions, short-TE MRS can be employed for the reproducible detection of GABA at 3 T, but that the technique should be used with caution, as the results are dependent on the experimental conditions. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND: Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland. METHODS: IRT was measured using AutoDELFIA Neonatal IRT-Kit in stored NBS cards. RESULTS: Between 2006 and 2009, 66 children with CF were reported, 4 of which were excluded for various reasons (born in another country, NBS at 6 months, no informed consent). 98% (61/62) had significantly higher IRT compared to matched control group. There was one false negative IRT result in an asymptomatic child with atypical CF (normal pancreatic function and sweat test). CONCLUSIONS: All children but one with atypical CF would have been detected with the planned two step protocol.
Resumo:
BACKGROUND: Outcome following foot and ankle surgery can be assessed by disease- and region-specific scores. Many scoring systems exist, making comparison among studies difficult. The present study focused on outcome measures for a common foot and ankle abnormality and compared the results obtained by 2 disease-specific and 2 body region-specific scores. METHODS: We reviewed 41 patients who underwent lateral ankle ligament reconstruction. Four outcome scales were administered simultaneously: the Cumberland Ankle Instability Tool (CAIT) and the Chronic Ankle Instability Scale (CAIS), which are disease specific, and the American Orthopedic Foot & Ankle Society (AOFAS) hindfoot scale and the Foot and Ankle Ability Measure (FAAM), which are both body region-specific. The degree of correlation between scores was assessed by Pearson's correlation coefficient. Nonparametric tests, the Kruskal-Wallis and the Mann-Whitney test for pairwise comparison of the scores, were performed. RESULTS: A significant difference (P < .005) was observed between the CAIS and the AOFAS score (P = .0002), between the CAIS and the FAAM 1 (P = .0001), and between the CAIT and the AOFAS score (P = .0003). CONCLUSIONS: This study compared the performances of 4 disease- and body region-specific scoring systems. We demonstrated a correlation between the 4 administered scoring systems and notable differences between the results given by each of them. Disease-specific scores appeared more accurate than body region-specific scores. A strong correlation between the AOFAS score and the other scales was observed. The FAAM seemed a good compromise because it offered the possibility to evaluate the patient according to his or her own functional demand. CLINICAL RELEVANCE: The present study contributes to the development of more critical and accurate outcome assesment methods in foot and ankle surgery.
Resumo:
In the last five years, Deep Brain Stimulation (DBS) has become the most popular and effective surgical technique for the treatent of Parkinson's disease (PD). The Subthalamic Nucleus (STN) is the usual target involved when applying DBS. Unfortunately, the STN is in general not visible in common medical imaging modalities. Therefore, atlas-based segmentation is commonly considered to locate it in the images. In this paper, we propose a scheme that allows both, to perform a comparison between different registration algorithms and to evaluate their ability to locate the STN automatically. Using this scheme we can evaluate the expert variability against the error of the algorithms and we demonstrate that automatic STN location is possible and as accurate as the methods currently used.
Resumo:
The primary sensory neurons in mouse dorsal root ganglia consist of diversified subpopulations which express distinct phenotypic characteristics such as substance P or calbindin D-28k. To determine whether neuronal phenotypes are altered or not in in vitro cultures carried out in a defined synthetic medium, dissociated dorsal root ganglion cells from newborn mice were grown in the alpha-modified minimum essential medium either supplemented with 10% fetal calf serum or serum-free. About 80% of the neurons survived after 5 days of culture in both media, but only 35% or 65% were rescued after 12 days in serum-free or fetal calf serum supplemented medium, respectively. The neuronal subpopulations expressing substance P or calbindin D-28k displayed similar morphological properties in both media and a higher resistance to culture conditions than the whole neuronal cell population, especially in serum-free medium. It is therefore concluded that a defined synthetic medium offers reproducible conditions to culture dorsal root ganglion cells for at least 5 days, stimulates the expression of substance P and enriches preferentially neuronal phenotypes expressing substance P or calbindin D-28k, for a longer period of culture.
Resumo:
OBJECTIVE: To describe a method to obtain a profile of the duration and intensity (speed) of walking periods over 24 hours in women under free-living conditions. DESIGN: A new method based on accelerometry was designed for analyzing walking activity. In order to take into account inter-individual variability of acceleration, an individual calibration process was used. Different experiments were performed to highlight the variability of acceleration vs walking speed relationship, to analyze the speed prediction accuracy of the method, and to test the assessment of walking distance and duration over 24-h. SUBJECTS: Twenty-eight women were studied (mean+/-s.d.) age: 39.3+/-8.9 y; body mass: 79.7+/-11.1 kg; body height: 162.9+/-5.4 cm; and body mass index (BMI) 30.0+/-3.8 kg/m(2). RESULTS: Accelerometer output was significantly correlated with speed during treadmill walking (r=0.95, P<0.01), and short unconstrained walks (r=0.86, P<0.01), although with a large inter-individual variation of the regression parameters. By using individual calibration, it was possible to predict walking speed on a standard urban circuit (predicted vs measured r=0.93, P<0.01, s.e.e.=0.51 km/h). In the free-living experiment, women spent on average 79.9+/-36.0 (range: 31.7-168.2) min/day in displacement activities, from which discontinuous short walking activities represented about 2/3 and continuous ones 1/3. Total walking distance averaged 2.1+/-1.2 (range: 0.4-4.7) km/day. It was performed at an average speed of 5.0+/-0.5 (range: 4.1-6.0) km/h. CONCLUSION: An accelerometer measuring the anteroposterior acceleration of the body can estimate walking speed together with the pattern, intensity and duration of daily walking activity.
Resumo:
The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-noise ratio (SNR) and vessel sharpness were compared. It was found that for improved mage quality a short navigator evaluation time is of crucial importance. Navigator spatial resolution showed minimal influence on image quality.
Resumo:
The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.
Resumo:
PURPOSE: The current study tested the applicability of Jessor's problem behavior theory (PBT) in national probability samples from Georgia and Switzerland. Comparisons focused on (1) the applicability of the problem behavior syndrome (PBS) in both developmental contexts, and (2) on the applicability of employing a set of theory-driven risk and protective factors in the prediction of problem behaviors. METHODS: School-based questionnaire data were collected from n = 18,239 adolescents in Georgia (n = 9499) and Switzerland (n = 8740) following the same protocol. Participants rated five measures of problem behaviors (alcohol and drug use, problems because of alcohol and drug use, and deviance), three risk factors (future uncertainty, depression, and stress), and three protective factors (family, peer, and school attachment). Final study samples included n = 9043 Georgian youth (mean age = 15.57; 58.8% females) and n = 8348 Swiss youth (mean age = 17.95; 48.5% females). Data analyses were completed using structural equation modeling, path analyses, and post hoc z-tests for comparisons of regression coefficients. RESULTS: Findings indicated that the PBS replicated in both samples, and that theory-driven risk and protective factors accounted for 13% and 10% in Georgian and Swiss samples, respectively in the PBS, net the effects by demographic variables. Follow-up z-tests provided evidence of some differences in the magnitude, but not direction, in five of six individual paths by country. CONCLUSION: PBT and the PBS find empirical support in these Eurasian and Western European samples; thus, Jessor's theory holds value and promise in understanding the etiology of adolescent problem behaviors outside of the United States.