Pitfalls in cefepime titration from human plasma: plasma- and temperature-related drug degradation in vitro.


Autoria(s): Bugnon D.; Giannoni E.; Majcherczyk P.; Glauser M.P.; Moreillon P.
Data(s)

2002

Resumo

While developing a high-pressure liquid chromatography assay for cefepime in plasma, we observed significant drug degradation at 20 and 37 degrees C but not at 4 degrees C. This plasma-related degradation persisted after protein removal. This warrants caution regarding cefepime assays for pharmacokinetic and pharmacodynamic studies of cefepime in vitro and in vivo.

Identificador

http://serval.unil.ch/?id=serval:BIB_9803E7334361

isbn:0066-4804 (Print)

pmid:12384385

doi:10.1128/AAC.46.11.3654-3656.2002

isiid:000178712800053

Idioma(s)

en

Fonte

Antimicrobial Agents and Chemotherapy, vol. 46, no. 11, pp. 3654-3656

Palavras-Chave #Cephalosporins/blood; Cephalosporins/chemistry; Chromatography, High Pressure Liquid; Humans; Reproducibility of Results; Temperature; Ultrafiltration