960 resultados para Radiation use efficiency
Resumo:
Gradually smart grids and smart meters are closer to the home consumers. Several countries has developed studies focused in the impacts arising from the introduction of these technologies and one of the main advantages are related to energy efficiency, observed through the awareness of the population on behalf of a more efficient consumption. These benefits are felt directly by consumers through the savings on electricity bills and also by the concessionaires through the minimization of losses in transmission and distribution, system stability, smaller loading during peak hours, among others. In this article two projects that demonstrate the potential energy savings through smart meters and smart grids are presented. The first performed in Korea, focusing on the installation of smart meters and the impact of use of user interfaces. The second performed in Portugal, focusing on the control of loads in a residence with distributed generation.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Química e Bioquímica pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
In health related research it is common to have multiple outcomes of interest in a single study. These outcomes are often analysed separately, ignoring the correlation between them. One would expect that a multivariate approach would be a more efficient alternative to individual analyses of each outcome. Surprisingly, this is not always the case. In this article we discuss different settings of linear models and compare the multivariate and univariate approaches. We show that for linear regression models, the estimates of the regression parameters associated with covariates that are shared across the outcomes are the same for the multivariate and univariate models while for outcome-specific covariates the multivariate model performs better in terms of efficiency.
Resumo:
As células foto voltaicas orgânicas ou células de Gräetzel (depois do seu descobridor) são aparelhos para a colecta de energia solar que utilizam um semicondutor inorgânico e uma molécula orgânica. Dita molécula orgânica é capaz de excitar-se na presença de radiação electromagnética e ceder esta energia através da doação de electrões a este semicondutor. Embora estas estruturas e o seu processo de fabrico sejam relativamente pouco onerosas, o aproveitamento da energia solar é ainda muito baixo. Para além desta deficiência, os corantes sintéticos sofrem de “bleaching” ou então são reduzidos ou oxidados facilmente quando não conseguem transferir a energia que foi absorvida ou quando é difícil voltar ao estado original por dificuldades no completamento de circulação de electrões. Neste trabalho pretende-se então estudar o comportamento de moléculas e misturas complexas de moléculas com capacidade para serem excitadas pela luz solar. Como a dita xcitação promove a transferência de um electrão, este processo será seguido pela técnica de Voltametria cíclica. Como substâncias absorventes de luz utilizaremos compostos naturais (principalmente flavonóides) puros, ou então na forma de complexos naturais extraídos de algumas plantas. Estas misturas de corantes serão extractos aquosos (infusões) de casca de laranja e limão assim como extractos de folhas de cerejeira, com o objectivo de proporcionar lternativas aos flavonóides utilizados neste estudo. A caracterização voltamétrica desta célula é feita em diferentes formas de iluminação. Sobre a célula assim formada faz-se incidir rimeiro luz de lâmpadas fluorescentes, depois luz ultra violeta e por fim sem qualquer tipo de luz incidente. Na base do fabrico da variante mais clássica destas células está o semicondutor óxido de itânio (TiO2), por ser uma substância muito comum e barata e com propriedades semicondutoras notáveis. Uma forma comum de melhorar a eficiência deste material é introduzir dopantes com o intuito de melhorar a eficiência do processo de transferência electrónica. Um segundo objectivo deste trabalho é o estudo de sistemas semicondutor/molécula foto activa. Semicondutores como ZnO, TiO2 e TiO2 dopado serão então estudados. O gels de TiO2 ou o TiO2 dopado serão depositados sobre lâminas de vidro comum, nas quais foi anteriormente depositado uma película de alumínio que serve de condutor (eléctrodo egativo). Uma outra variante será a utilização de óxido de zinco, um semicondutor de baixo custo que por sua vez vai ser depositado em lâminas de alumínio comercial. A nossa célula foto electroquímica será então formada por moléculas de corante, uma lâmina e um semicondutor (que funcionará como eléctrodo de trabalho), com ou sem electrólito/catalizador (solução de iodo/iodeto), e eléctrodos de referência de Ag/AgCl, e outro auxiliar de grafite. Um outro objectivo é fazer um pequeno estudo sobre influencia do catalisador I2/etilenodiamina no comportamento electroquímico da célula, de forma a poder utilizar o solvente (etilenodiamina) com menor volatilidade do que a água, que é empregada no par I2/I3.m A importância deste facto prende-se com a limitada vida destas células quando o electrólito/solvente é evaporado pelas altas temperaturas da radiação incidente.
Resumo:
Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Tese apresentada como requisito parcial para obtenção do grau de Doutor em Gestão de Informação
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentável
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.
Resumo:
The reduction of greenhouse gas emissions is one of the big global challenges for the next decades due to its severe impact on the atmosphere that leads to a change in the climate and other environmental factors. One of the main sources of greenhouse gas is energy consumption, therefore a number of initiatives and calls for awareness and sustainability in energy use are issued among different types of institutional and organizations. The European Council adopted in 2007 energy and climate change objectives for 20% improvement until 2020. All European countries are required to use energy with more efficiency. Several steps could be conducted for energy reduction: understanding the buildings behavior through time, revealing the factors that influence the consumption, applying the right measurement for reduction and sustainability, visualizing the hidden connection between our daily habits impacts on the natural world and promoting to more sustainable life. Researchers have suggested that feedback visualization can effectively encourage conservation with energy reduction rate of 18%. Furthermore, researchers have contributed to the identification process of a set of factors which are very likely to influence consumption. Such as occupancy level, occupants behavior, environmental conditions, building thermal envelope, climate zones, etc. Nowadays, the amount of energy consumption at the university campuses are huge and it needs great effort to meet the reduction requested by European Council as well as the cost reduction. Thus, the present study was performed on the university buildings as a use case to: a. Investigate the most dynamic influence factors on energy consumption in campus; b. Implement prediction model for electricity consumption using different techniques, such as the traditional regression way and the alternative machine learning techniques; and c. Assist energy management by providing a real time energy feedback and visualization in campus for more awareness and better decision making. This methodology is implemented to the use case of University Jaume I (UJI), located in Castellon, Spain.
Resumo:
INTRODUCTION: Although urine is considered the gold-standard material for the detection of congenital cytomegalovirus (CMV) infection, it can be difficult to obtain in newborns. The aim of this study was to compare the efficiency of detection of congenital CMV infection in saliva and urine samples. METHODS: One thousand newborns were included in the study. Congenital cytomegalovirus deoxyribonucleic acid (DNA) was detected by polymerase chain reaction (PCR). RESULTS: Saliva samples were obtained from all the newborns, whereas urine collection was successful in only 333 cases. There was no statistically significant difference between the use of saliva alone or saliva and urine collected simultaneously for the detection of CMV infection. CONCLUSIONS: Saliva samples can be used in large-scale neonatal screening for CMV infection.