989 resultados para Molí de Pals (Pals)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leprosy, a chronic infectious disease, is caused by a Mycobacterium leprae infection. After India, Brazil has the second greatest number of cases in the world. Increase of oxidative stress and antioxidant deficiency are present in infected subjects and can be related to infection progression. We studied alterations in serum levels of lipid peroxidation (LPO) and vitamin A in patients with different forms of leprosy. Four groups of leprosy patients and a control group (healthy subjects) were selected, and their vitamin A serum levels and LPO profile, measured as malonaldehyde (MDA) were measured by spectrophotometric assays. The mean MDA serum levels (µmol/L) were 3.80 ± 0.5 for control group and 10.54 ± 1.1 in the leprosy patients and this increase was gradual, being more accentuated in severe forms of the disease. Also, the vitamin A serum levels (µg/dL) were diminished in the infected subjects (38.51 ± 4.2), mainly in lepromatous form, when compared with the control group (53.8 ± 5.6). These results indicate that LPO can be an important factor in Mycobacterium leprae infection, which can be related to increases in phagocytic activity and the general breakdown of antioxidants, contributing to an increase of LPO during infection progression. The evaluation of oxidant/antioxidant status in these patients can be an important factor in the treatment, control, and/or prognosis of this disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new environmentally friendly Au nanoparticles (Au NPs) synthesis in glycerol by using ultraviolet irradiation and without extra-added stabilizers is described. The synthesis proposed in this work may impact on the non-polluting production of noble nanoparticles with simple chemicals normally found in standard laboratories. These Au NPs were used to modify a carbon paste electrode (CPE) without having to separate them from the reaction medium. This green electrode was used as an electrochemical sensor for the nitrite detection in water. At the optimum conditions the green sensor presented a linear response in the 2.0×10−7–1.5×10−5 M concentration range, a good detection sensitivity (0.268 A L mol−1), and a low detection limit of 2.0×10−7 M of nitrite. The proposed modified green CPE was used to determine nitrite in tap water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work was to develop a reliable alternative method for the determination of the dithiocarbamate pesticide mancozeb (MCZ) in formulations. Furthermore, a method for the analysis of MCZ's major degradation product, ethylenethiourea (ETU), was also proposed. Cyclic voltammetry was used to characterize the electrochemical behavior of MCZ and ETU, and square-wave adsorptive stripping voltammetry (SWAdSV) was employed for MCZ quantification in commercial formulations. It was found that both MCZ and ETU are irreversibly reduced (− 0.6 V and − 0.5 V vs Ag/AgCl, respectively) at the surface of a glassy carbon electrode in a mainly diffusion-controlled process, presenting maximum peak current intensities at pH 7.0 (in phosphate buffered saline electrolyte). Several parameters of the SWAdSV technique were optimized and linear relationships between concentration and peak current intensity were established between 10–90 μmol L− 1 and 10–110 μmol L− 1 for MCZ and ETU, respectively. The limits of detection were 7.0 μmol L− 1 for MCZ and 7.8 μmol L− 1 for ETU. The optimized method for MCZ was successfully applied to the quantification of this pesticide in two commercial formulations. The developed procedures provided accurate and precise results and could be interesting alternatives to the established methods for quality control of the studied products, as well as for analysis of MCZ and ETU in environmental samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work has as objective to contribute for the elucidation of the mechanism associated with Pb detoxification, using the yeast Saccharomyces cerevisiae as a model organism. The deletion of GTT1 or GTT2 genes, coding for functional glutathione transferases (GST) enzymes in S. cerevisiae, caused an increased susceptibility to high Pb concentrations (500-1000 μmol L(-1)). These results suggest that the formation of glutathione-Pb conjugate (GS-Pb), dependent of GSTs, is important in Pb detoxification. The involvement of ATP-binding cassette (ABC) vacuolar transporters, belonging to class C subfamily (ABCC) in vacuolar compartmentalization of Pb, was evaluated. For this purpose, mutant strains disrupted in YCF1, VMR1, YBT1 or BPT 1 genes were used. All mutants tested, without vacuolar ABCC transporters, presented an increased sensitivity to 500-1000 μmol L(-1) Pb comparative to wild-type strain. Taken together, the obtained results suggest that Pb detoxification, by vacuolar compartmentalization, can occur as a result of the concerted action of GSTs and vacuolar ABCC transporters. Pb is conjugated with glutathione, catalysed by glutathione transferases and followed to the transport of GS-Pb conjugate to the vacuole by ABCC transporters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work explores the use of fluorescent probes to evaluate the responses of the green alga Pseudokirchneriella subcapitata to the action of three nominal concentrations of Cd(II), Cr(VI), Cu(II) and Zn(II) for a short time (6 h). The toxic effect of the metals on algal cells was monitored using the fluorochromes SYTOX Green (SG, membrane integrity), fluorescein diacetate (FDA, esterase activity) and rhodamine 123 (Rh123, mitochondrial membrane potential). The impact of metals on chlorophyll a (Chl a) autofluorescence was also evaluated. Esterase activity was the most sensitive parameter. At the concentrations studied, all metals induced the loss of esterase activity. SG could be used to effectively detect the loss of membrane integrity in algal cells exposed to 0.32 or 1.3 μmol L−1 Cu(II). Rh123 revealed a decrease in the mitochondrial membrane potential of algal cells exposed to 0.32 and 1.3 μmol L−1 Cu(II), indicating that mitochondrial activity was compromised. Chl a autofluorescence was also affected by the presence of Cr(VI) and Cu(II), suggesting perturbation of photosynthesis. In conclusion, the fluorescence-based approach was useful for detecting the disturbance of specific cellular characteristics. Fluorescent probes are a useful diagnostic tool for the assessment of the impact of toxicants on specific targets of P. subcapitata algal cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complex interaction between hepatitis C virus infection, iron homeostasis and the response to antiviral treatment remains controversial. The aim of this study was to evaluate the influence of hepatic iron concentration (HIC) on the sustained virological response (SVR) to antiviral therapy in patients with chronic hepatitis C. A total of 50 patients who underwent pretreatment liver biopsy with assessment of HIC by graphite furnace atomic absorption spectroscopy and were subsequently submitted to antiviral treatment with interferon/peginterferon and ribavirin were included in the study. Patients with alcoholism, history of multiple blood transfusion, chronic kidney disease, hemolytic anemia and parenteral iron therapy were excluded. The iron related markers and HIC were compared between those who achieved an SVR and non-responders (NR) patients. The mean age was 45.7 years and the proportion of patients' gender was not different between SVR and NR patients. The median serum iron was 138 and 134 µg/dL (p = 0.9), the median serum ferritin was 152.5 and 179.5 ng/mL (p = 0.87) and the median HIC was 9.9 and 8.2 µmol/g dry tissue (p = 0.51), for SVR and NR patients, respectively. Thus, hepatic iron concentration, determined by a reliable quantitative method, was not a negative predictive factor of SVR in patients with chronic hepatitis C presenting mild to moderate hepatic iron accumulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O controlo da qualidade em ressonância magnética (RM) passa pela realização de diversos testes ao equipamento e calibrações diárias, onde os fantomas desempenham um papel fundamental. Este trabalho teve como objetivo principal o desenvolvimento de um fantoma cerebral para um sistema de RM de intensidade 3.0 Tesla. Com base na literatura existente, escolheram-se como reagentes o cloreto de gadolínio (III) (GdCl3), a agarose, e o gelificante carragena, tendo sido ainda acrescentado o conservante químico azida de sódio (NaN3) de forma a inibir a degradação da solução. Realizaram-se vários testes com diferentes concentrações dos materiais selecionados até obter as misturas adequadas a suscetibilidade magnética das substâncias branca e cinzenta cerebrais. Os tempos de relaxação T1 das diversas substâncias desenvolvidas foram medidos, apresentando o fantoma final uns tempos de T1 de 702±10 ms, quando a concentração de GdCl3 foi de 100 µmol (substância branca) e 1179±23 ms quando a concentração foi de 15 µmol (substância cinzenta). Os valores de T1 do fantoma foram comparados estatisticamente com os tempos de relaxação conseguidos a partir de um cérebro humano, obtendo-se uma correlação de 0.867 com significância estatística. No intuito de demonstrar a aplicabilidade do fantoma, este foi sujeito a um protocolo de RM, do qual constaram as sequências habitualmente usadas no estudo cerebral. Como principais resultados constatou-se que, nas sequências ponderadas em T1, o fantoma apresenta uma forte associação positiva (rs > 0.700 p = 0.072) com o cérebro de referência, ainda que não sejam estatisticamente significativos. As sequências ponderadas em T2 demonstraram uma correlação positiva moderada e fraca, sendo a ponderação densidade protónica a única a apresentar uma associação negativa. Desta forma, o fantoma revelou-se um ótimo substituto do cérebro humano. Este trabalho culminou na criação de um modelo cerebral tridimensional onde foram individualizadas as regiões das substâncias branca e cinzenta, de forma a posteriormente serem preenchidas pelas correspondentes substâncias desenvolvidas, obtendo-se um fantoma cerebral antropomórfico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O chumbo é um importante poluente ambiental. A levedura Saccharomyces cerevisiae constitui um modelo útil para o estudo dos efeitos tóxicos do chumbo. O conhecimento dos mecanismos de defesa e resistência à presença de metais pesados poderá ser útil em tecnologias de proteção ambiental, nomeadamente no desenvolvimento de novas metodologias para a biorremediação de metais pesados. O presente trabalho teve como objetivo avaliar o impacto do Pb na capacidade proliferativa, na integridade membranar e na produção intracelular de espécies reativas de oxigénio (ROS), na estirpe laboratorial da levedura Saccharomyces cerevisiae BY4741 (estirpe selvagem, WT). Foi também estudado o papel das mitocôndrias, como fonte de ROS induzida por Pb, e o envolvimento da H+-ATPase vacuolar (V-ATPase) e de transportadores vacuolares pertencentes à superfamília ABC (de ATP-binding cassette) na defesa contra a toxicidade do Pb. O estudo cinético do impacto de duas concentrações de Pb na viabilidade das leveduras (avaliado através de um ensaio clonogénico), na integridade da membrana celular (determinada com iodeto de propídio) e na produção intracelular de ROS (o anião superóxido foi detetado com dihidroetídio e o peróxido de hidrogénio com 2’,7’- diclorodihidrofluoresceína), revelou uma perda progressiva da capacidade proliferativa (53 e 17% de células viáveis, após a exposição durante 3h a 250 ou 1000 µmol/l de chumbo, respetivamente), coincidente com a acumulação intracelular de anião superóxido e de peróxido de hidrogénio, na ausência de perda da integridade membranar. A importância das mitocôndrias na produção de ROS, induzida por chumbo, foi levada a cabo usando um mutante deficiente respiratório desprovido de ADN mitocondrial (ƿ0). Quando comparado com a respetiva estirpe parental, o mutante ƿ0 apresentou uma maior resistência ao Pb e uma menor produção de ROS induzida por Pb. A exposição das células da estirpe BY4741 a 250 e 1000 µmol/l de chumbo originou a formação de 49 e 58% de células deficientes respiratórias, respetivamente. A função da V-ATPase, na desintoxicação de chumbo, foi avaliada utilizando mutantes com uma estrutura vacuolar normal mas defetivos em subunidades da VATPase (vma1Δ, vma2Δ, vma3Δ e vph1Δ). Comparativamente às células da estirpe WT, todos os mutantes testados, sem V-ATPase funcional, apresentaram uma maior suscetibilidade ao Pb. O papel dos transportadores vacuolares pertencentes à superfamília ABC, na defesa contra a toxicidade induzida por chumbo, foi levada a cabo utilizando mutantes sem os transportadores Ycf1p ou Vmr1p. Os resultados preliminares mostraram que quando comparadas com as células da estirpe WT, as células das estirpes ycf1Δ ou vmr1Δ não apresentavam uma maior perda da viabilidade. A modificação da morfologia vacuolar, em células expostas a chumbo, foi visualizada utilizando a estirpe Vma2p-GFP. O tratamento das células com Pb originou a fusão dos vacúolos de tamanho médio num único vacúolo de grande dimensão. Em conclusão, os estudos desenvolvidos no presente trabalho, utilizando a estirpe laboratorial BY4741, mostraram que a perda da capacidade proliferativa das leveduras, induzida pelo chumbo, pode ser atribuída à acumulação intracelular do anião superóxido e de peróxido de hidrogénio. As mitocôndrias parecem ser uma das principais fontes de ROS induzido por Pb e, simultaneamente, um dos principais alvos da sua toxicidade. Em S. cerevisiae, o vacúolo desempenha um papel importante na desintoxicação do Pb. A modificação da morfologia vacuolar após exposição ao chumbo poderá ser a consequência da acumulação de Pb no vacúolo. Enquanto os transportadores da superfamília ABC parecem não estar envolvidos na sequestração vacuolar de Pb, é necessária a presença, num estado funcional, da V-ATPase para que ocorra a compartimentação do Pb. Muito provavelmente, a compartimentação do Pb no vacúolo previne a sua acumulação no citosol e o desencadear dos respetivos efeitos tóxicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente dissertação tem com objetivo o desenvolvimento de um biossensor com base nos polímeros de impressão molecular para a deteção de uma molécula alvo, o ácido glutâmico que é convertido em glutamina pela glutamina sintetase, recorrendo à potenciometria. Nas células neoplásicas a glutamina não é sintetizada podendo-se considerar que o ácido glutâmico é um potencial agente anti-cancro. A técnica de impressão molécular utilizada foi a polimerização em bulk, combinando a acrilamida e a bis acrilamida com o ácido glutâmico. Para se verificar se a resposta potenciométrica obtida era de facto da molécula alvo foram preparados em paralelo com os sensores, materiais de controlo, ou seja, moléculas sem impressão molécular (NIP). Para se controlar a constituíção química dos vários sensores nomeadamente, do NIP e do polímero de impressão molecular (MIP) antes e após a remoção bem como a molécula foram realizados estudos de Espetroscopia de Infravermelhos de Transformada de Fourier (FTIR), Scanning electron microscope (SEM) e Espetroscopia de Raios X por dispersão em energia (EDS). Os materiais desenvolvidos foram aplicados em várias membranas que diferiam umas das outras, sendo seletivas ao ião. A avaliação das características gerais das membranas baseou-se na análise das curvas de calibração, conseguidas em meios com pHs diferentes, comparando os vários elétrodos. O pH 5 foi o que apresentou melhor resultado, associado a uma membrana que continha um aditivo, o p-tetra-octilphenol, e com o sensor com percentagem de 3%. Posto isto, testou-se em material biológico, urina, com as melhores características quer em termos de sensibilidade (18,32mV/década) quer em termos de linearidade (1,6x10-6 a 1,48x10-3 mol/L). Verificou-se ainda que aplicando iões interferentes na solução, estes não interferem nesta, podendo ser aplicados na amostra sem que haja alteração na resposta potenciométrica. O elétrodo é capaz de distinguir o ácido glutâmico dos restantes iões presentes na solução.