951 resultados para Mismatch repair


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to observe the healing process of intentional lateral root perforation repaired with mineral trioxide aggregate (MTA). Forty-eight root canals of dogs' teeth were instrumented and filled. After partial removal of the filling, an intentional perforation was made with a bur in the lateral area of the root. The perforations were repaired with MTA or Sealapex (control group). Histological analysis occurred 30 and 180 days after treatment. Results showed no inflammation and deposition of cementum over MTA in the majority of the specimens. In the 180-day period, Sealapex exhibited chronic inflammation in all the specimens and slight deposition of cementum over the material in only three cases. In conclusion, MTA exhibited better results than the control group. Copyright © 2001 by The American Association of Endodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty-four root canals of premolars from six dogs were left open for 7 days, and then sealed and followed for 45 days until periradicular periodontitis developed. The root canals were then treated endodontically using 5.25% sodium hypochlorite as the irrigating solution. After instrumentation, all root canals were filled with a calcium hydroxide-based antibacterial dressing (Calen PMCC or Calasept) that was left in place for 30 days. After this period the root canals were filled with gutta-percha cones and a root canal sealer (Sealapex or AH Plus)-group I: Calen PMCC + Sealapex; group II: Calasept + Sealapex; group III: Calen PMCC + AH Plus; and group IV: Calasept + AH Plus. Periapical radiographs of the teeth were made after root canal filling and after 90, 180, 270, and 360 days. Radiographic images were digitalized by scanning, and the Mocha program was used to measure the periapical lesions. Analysis showed that the lesions of groups I to III were statistically similar reduction in size, whereas group IV had a smaller reduction in lesion size (p < 0.05). Copyright © 2001 by The American Association of Endodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate periapical and apical repair using calcium hydroxide root canal dressings for different lengths of times in teeth with induced chronic periapical lesions. A total of 61 root canals of maxillary and mandibular premolars from 4 dogs were used. After mechanical preparation of the root canals using the crown-down technique, and 5.25% NaOCl as irrigating solution, the apical foramen was enlarged in all cases. A calcium hydroxide root canal dressing was applied. The control group did not receive a root canal dressing. The animals were killed at 7, 15 or 30 days. After histological preparation, serial sections were stained with hematoxylin-eosin and Mallory's trichrome. The best histopathological results occurred at 15 and 30 days, and the worst results occurred at 7 days and in the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the apical and periapical repair after root canal treatment of dogs' teeth with pulp necrosis and chronic periapical lesion using different root canal sealers. After periapical lesion induction, forty-four root canals of 3 dogs were submitted to biomechanical preparation using 5.25% sodium hypochlorite as an irrigating solution. A calcium hydroxide dressing (Calen PMCC) was applied for 15 days and the root canals were filled using the lateral condensation technique with gutta-percha points and Sealapex, AH Plus or Sealer Plus for sealing. After 180 days, the animals were sacrificed by anesthetic overdose and the obtained histological sections were stained with hematoxylin-eosin for optical microscopic analysis of the apical and periapical repair. The groups filled with Sealapex and AH Plus had better histological repair (p < 0.05) than the group filled with Sealer Plus, that had unsatisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare by qualitative histology the efficacy of rigid internal fixation with titanium system and the Lacto Sorb® system in mandibular fractures in rabbits. Thirty male adult rabbits Oryctolagus cuniculus were used. Unilateral mandibular osteotomies were performed between the canine and first premolar. The animals were divided into two groups: for Group I - rigid internal fixation was performed with titanium system 1.5 mm (Synthes, Oberdorf, Switzerland), with two screws of 6 mm (bicortical) on each side of the osteotomy. For Group II-rigid internal fixation was performed with PLLA/PGA system 1.5 mm (Lacto Sorb®, WLorenz, Jacksonville, FL, USA). The histological analysis evaluated the presence of inflammatory reaction, degree of bone healing and degree of resorption of the Lacto Sorb® screws. The results of both fixation systems were similar, only with a small difference after 15 and 30 days. In Group I a faster bony healing was noted. But after 60 days, bony healing was similar in both groups. It is concluded that both PLLA/PGA and titanium plates and screws provide sufficient strength to permit mandibular bone healing. The resorption process of PLLA/PGA osteosynthesis material did not cause acute or chronic inflammatory reaction or foreign body reaction during the studied period. © 2004 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: We evaluated solvents and total particulates exposures in auto body repair shops together with a search of painter's related complaints. Methods: 26 painters exposures were evaluated by pumped personal sampling; solvents were retained in charcoal sorbent tubes and the particulates in PVC filters. Painter's personal habits and their work characteristics were obtained through a questionnaire, applied in a private interview. For the symptoms the Q16 questionnaire was used, added of questions about complaints during the painting. Results: High exposures were detected during spray painting. For solvents, the TLV-STEL adjusted for the mixtures was surpassed in six evaluations. However, as repaint is a short-term operation, it makes the average concentrations weighed for the work shift lower than the TLV-TWA adjusted for the mixtures. Total particulate concentrations had surpassed the TLV-TWA in four of the evaluations. Symptoms frequency in the Q16 questionnaire was higher for painters than for the controls (Mann-Whitney test U=193; p=0.008), and they showed positive correlations with the age (Spearman r=0.354, t=1.85, p=0.076), the number of years in the profession (Spearman r=0.433, t=2.35, p=0.027) and the alcoholic beverage consumption (Spearman r=0.457, t=2.516, p=0.019). Conclusions: The painting work done at car repair shops can result in high solvent and particulate exposures, although they are short-term operations. Their acute and chronic effects for the painters do not have been clearly evidenced in the present study, continuing deserving multidisciplinary attention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the association between polymorphisms XRCC1 Arg194Trp and Arg399Gln and XRCC3 Thr241Met and the risk for chronic gastritis and gastric cancer, in a Southeastern Brazilian population. Methods: Genotyping by PCR-RFLP was carried out on 202 patients with chronic gastritis (CG) and 160 patients with gastric cancer (GC), matched to 202 (C1) and 150 (C2) controls, respectively. Results: No differences were observed among the studied groups with regard to the genotype distribution of XRCC1 codons 194 and 399 and of XRCC3 codon 241. However, the combined analyses of the three variant alleles (194Trp, 399Gln and 241Met) showed an increased risk for chronic gastritis when compared to the GC group. Moreover, an interaction between the polymorphic alleles and demographic and environmental factors was observed in the CG and GC groups. XRCC1 194Trp was associated with smoking in the CG group, while the variant alleles XRCC1 399Gln and XRCC3 241Met were related with gender, smoking, drinking and H pylori infection in the CG and GC groups. Conclusion: Our results showed no evidence of a rela-tionship between the polymorphisms XRCC1 Arg194Trp and Arg399Gln and XRCC3 Thr241Met and the risk of chronic gastritis and gastric cancer in the Brazilian population, but the combined effect of these variants may interact to increase the risk for chronic gastritis, considered a premalignant lesion. Our data also indicate a gene-environment interaction in the susceptibility to chronic gastritis and gastric cancer. © 2005 The WJG Press and Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis, a disease characterized by progressive bone loss, has been the target of several studies in the past few years. It results in a much higher risk for fractures and might cause slower bone lesion healing. The aim of this work was to study the effects of Risedronate (allopathic medicine) and Calcarea phosphorica 6CH (homeopathic medicine) on the repair of bone lesions in male rats with osteoporosis induced by castration. Eighty-four three-month-old rats were used divided into four groups of twenty-one animals each. Three groups where castrated and one group was submitted to Sham surgery. One month later, cortical lesions were made in all animals' tibiae and, after one day, the different experimental treatments began according to the following groups: CR - castrated/Risedronate (1 mg/kg/day); CCp - castrated/ Calcarea phosphorica 6CH (3 drops/day); CP - castrated/placebo and SP - Sham/placebo. The animals were sacrificed at seven, fourteen and twenty-eight days after the beginning of the treatments and had their tibiae removed. Digital radiographs of the tibiae were taken and analyzed in order to evaluate the optical density of the defect area. Then, they were decalcified and processed for histological and histomorphometrical analysis. The data were submitted to ANOVA, and to the Tukey and Dunnett tests (5%). The allopathic and homeopathic treatments led to different bone formation as regards remodeling and maturation aspects. Further research is necessary to access the resistance and quality of the newly formed bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of surface conditioning methods and thermocycling on the bond strength between a resin composite and an indirect composite system in order to test the repair bond strength. Materials and Methods: Eighteen blocks (5 x 5 x 4 mm) of indirect resin composite (Sinfony) were fabricated according to the manufacturer's instructions. The specimens were randomly assigned to one of the following two treatment conditions (9 blocks per treatment): (1) 10% hydrofluoric acid (HF) for 90 s (Dentsply) + silanization, (2) silica coating with 30-Ìm SiOx particles (CoJet) + silanization. After surface conditioning, the bonding agent was applied (Adper Single Bond) and light polymerized. The composite resin (W3D Master) was condensed and polymerized incrementally to form a block. Following storage in distilled water at 37°C for 24 h, the indirect composite/resin blocks were sectioned in two axes (x and y) with a diamond disk under coolant irrigation to obtain nontrimmed specimens (sticks) with approximately 0.6 mm2 of bonding area. Twelve specimens were obtained per block (N = 216, n = 108 sticks). The specimens from each repaired block were again randomly divided into 2 groups and tested either after storage in water for 24 h or thermocycling (6000 cycles, 5°C to 55°C). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using two-way ANOVA (α = 0.05). Results: Both surface conditioning (p = 0.0001) and storage conditions (p = 0.0001) had a significant effect on the results. After 24 h water storage, silica coating and silanization (method 2) showed significantly higher bond strength results (46.4 ± 13.8 MPa) than that of hydrofluoric acid etching and silanization (method 1) (35.8 ± 9.7 MPa) (p < 0.001). After thermocycling, no significant difference was found between the mean bond strengths obtained with method 1 (34.1 ± 8.9 MPa) and method 2 (31.9 ± 7.9 MPa) (p > 0.05). Conclusion: Although after 24 h of testing, silica coating and silanization performed significantly better in resin-resin repair bond strength, both HF acid gel and silica coating followed by silanization revealed comparable bond strength results after thermocycling for 6000 times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the microtensile bond strength of a repair composite resin to a leucite-reinforced feldspathic ceramic (Omega 900, VITA) submitted to two surface conditionings methods: 1) etching with hydrofluoric acid + silane application or 2) tribochemical silica coating. The null hypothesis is that both surface treatments can generate similar bond strengths. Ten ceramic blocks (6x6x6 mm) were fabricated and randomly assigned to 2 groups (n=5), according to the conditioning method: G1- 10% hydrofluoric acid application for 2 min plus rinsing and drying, followed by silane application for 30 s; G2- airborne particle abrasion with 30 μm silica oxide particles (CoJet-Sand) for 20 s using a chairside air-abrasion device (CoJet System), followed by silane application for 5 min. Single Bond adhesive system was applied to the surfaces and light cured (40 s). Z-250 composite resin was placed incrementally on the treated ceramic surface to build a 6x6x6 mm block. Bar specimens with an adhesive area of approximately 1 ± 0.1 mm2 were obtained from the composite-ceramic blocks (6 per block and 30 per group) for microtensile testing. No statistically significant difference was observed between G1 (10.19 ± 3.1 MPa) and G2 (10.17 ± 3.1 MPa) (p=0.982) (Student's t test; á = 0.05). The null hypothesis was, therefore, accepted. In conclusion, both surface conditioning methods provided similar microtensile bond strengths between the repair composite resin and the ceramic. Further studies using long-term aging procedures should be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibrin glue has been researched as an alternative method for tissue synthesis and is known for its capability to promote hemostasis at the application site, good approximation of wound edges and fast healing. The current study consisted in the application of fibrin glue derived from snake venom as treatment for experimental corneal ulcers. Twenty-one dogs had their corneas experimentally prepared through lamellar keratectomy (of standardized diameter and depth). Animals were divided into seven groups of three animals each. Six experimental groups were periodically evaluated and collection was carried out on the 1st, 3rd, 7th, 15 th, 30th and 60th post-operative days, whereas one control group was evaluated throughout the experiment. Analyses consisted in the clinical evolution and in the histopathological study of all operated on eyes. Results indicated that fibrin glue was efficient in repairing keratectomy wounds in dogs and contributed to an earlier healing phenomenon, avoiding edema formation and keeping corneal clearness. The use of fibrin glue derived from snake venom showed to be easy to apply, feasible with animal models and of low cost, avoiding the lesion progress and allowing fast and appropriate corneal healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gelfoam® - a biologically resorbable gelatin sponge - has the function of restricting hemorrhage, providing platelet rupture, and supporting fibrin threads. Beriplast® - a fibrinogen-thrombin compound - is used to adhere tissues, to consolidate sutures and in hemostasis. The objective of this study was to perform a histological analysis of the effects of haemostatic agents on osseous repair. These materials were inserted into surgical sites in young rat right and left tibiae. After the observation periods of 7, 14, 30 and 45 days, according to the bioethic protocol, the animals were killed, the tibiae were removed and fixed in 10% formalin and decalcified in equal parts of formic acid and sodium citrate solutions. After routine processing, the specimens were embedded in paraffin for microtomy. Analysis of the results demonstrated that the haemostatic agents are effective in controlling hemorrhage; they stimulate osteogenesis, featuring a pattern of osseous tissue formation similar to the control pattern, although the amount of osseous trabeculae was superior, especially in the Gelfoam group in the periods of 7 and 14 days; 30 days after surgery, the delay in tissue healing in the control group in relation to the experimental groups started to decrease, and the control and experimental groups exhibited similar tissue repair after 45 days, when all the groups exhibited secondary osseous tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to present a possible carrier for MTA, monoolein gel, with the objective to maintain this material in the place that was inserted and verify if this procedure is able to optimize its action. The data were evaluated by histomorphometric method and submitted to statistical analysis. The histological responses observed in this study indicate that the MTA is a reliable material and should be considered effective in bone periapical defects and the monoolein gel was capable to maintain the MTA in situ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Vesicovaginal fistula (VVF) is one of the most devastating surgical complications that can occur in women. The primary cause remains an abdominal hysterectomy. Approach to this condition can be transvaginal or transabdominal. Laparoscopic repair of VVF may be an alternative approach to this treating rare condition. We present seven cases of VVF treated with transperitoneal laparoscopic technique and our results. Methods: We retrospectively reviewed the charts of 7 women ranging from 37 to 74 years in age (mean age 52.8 years) at our institution who underwent laparoscopic transperitoneal repair of VVF between February 2004 and March 2006. Etiology of the VVF, surgical technique, operative time, length of hospital stay, and complications were reviewed. Results: Six of the seven VVFs we repaired laparoscopically resulted from gynecologic procedures, and one patient presented with a VVF after a ureterolithotripsy. Mean operative time ranged from 130 to 420 minutes (mean 280 minutes), and mean hospital stay was 7 days. In one patient conversion to open surgery was necessary due to prolonged operative time. Two complications occurred a urinary tract infection in one patient and an inferior limb compartment syndrome in another. Conclusion: Transvaginal laparoscopic repair of VVF is feasible and safe and provides excellent results. It is a good alternative to the abdominal approach. However, advanced laparoscopic skills are mandatory. © 2008 Mary Ann Liebert, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate a bone morphogenetic protein (BMP) implant with and without platelet-rich plasma (PRP), which is supposed to accelerate fracture consolidation in the orbit fracture treatment. Methods: Thirty-six white rabbits were subjected to orbital fracture and treated in three groups: BMP implant fracture repair (G1), BMP plus PRP implant fracture repair (G2), and fracture and spontaneous repair (G3). The animals were sacrificed at 7, 30, 90, and 180 days after surgery. A radiology evaluation was carried out on the 7th day after the fracture and at the sacrifice moments. After the animals' death, the orbital content material was removed and prepared for morphological and morphometric analysis. Results: Radiology suggested intramembranous and progressive cavitation and ossification without a reduction in implant size and with signs of calcium deposition; these events were confirmed by histological analysis, which showed a lymphomononuclear inflammatory reaction in G1 and G2, more intense 7 days after surgery and reducing after 30 days. Associating PRP with BMP did not accelerate bone induction. Conclusion: BMP implant promotes bone induction, integration at fracture site, scarce inflammatory reaction, and may be a good alternative in orbit fracture reconstruction. The addition of PRP to the BMP plate did not accelerate the resolution, and its use is not necessary. Copyright © Informa Healthcare USA, Inc.