752 resultados para HETEROJUNCTION BIPOLAR-TRANSISTORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The distributions of a carboxyl terminal splice variant of the glutamate transporter GLT-1, referred to as GLT-1B, and the carboxyl terminus of the originally described variant of GLT-1, referred to hereafter as GLT-1alpha, were examined using specific antisera. GLT-1B was present in the retina at very early developmental stages. Labelling was demonstrable at embryonic day 14, and strong labelling was evident by embryonic day 18. Such labelling was initially restricted to populations of cone photoreceptors, the processes of which extended through the entire thickness of the retina and appeared to make contact with the retinal ganglion cells. During postnatal development the GLT-1B-positive photoreceptor processes retracted to form the outer plexiform layer, and around postnatal day 7, GLT-1B-immunoreactive bipolar cells appeared. The pattern of labelling of bipolar cell processes within the inner plexiform layer changed during postnatal development. Two strata of strongly immunoreactive terminals were initially evident in the inner plexiform layer, but by adulthood these two bands were no longer evident and labelling was restricted to the somata and processes (but not synaptic terminals) of the bipolar cells, as well as the somata, processes, and terminals of cone photoreceptors. By contrast, GLT-1alpha appeared late in postnatal development and was restricted mainly to a population of amacrine cells, although transient labelling was also associated with punctate elements in the outer plexiform layer, which may represent photoreceptor terminals, (C) 2002 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion-the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examine the instability behavior of nanocrystalline silicon (nc-Si) thin-film transistors (TFTs) in the presence of electrical and optical stress. The change in threshold voltage and sub-threshold slope is more significant under combined bias-and-light stress when compared to bias stress alone. The threshold voltage shift (Delta V-T) after 6 h of bias stress is about 7 times larger in the case with illumination than in the dark. Under bias stress alone, the primary instability mechanism is charge trapping at the semiconductor/insulator interface. In contrast, under combined bias-and-light stress, the prevailing mechanism appears to be the creation of defect states in the channel, and believed to take place in the amorphous phase, where the increase in the electron density induced by electrical bias enhances the non-radiative recombination of photo-excited electron-hole pairs. The results reported here are consistent with observations of photo-induced efficiency degradation in solar cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a field-effect phototransistor with a channel comprising a thin nanocrystalline silicon transport layer and a thicker hydrogenated amorphous silicon absorption layer. The semiconductor and dielectric layers were deposited by radio-frequency plasma enhanced chemical vapor deposition. The phototransistor with channel length of 24 microns and photosensitive area of 1.4 mm(2) shows an off-current of about 1 pA, and high photoconductive gain in the subthreshold region. Measurements of the quantum efficiency at different incident light intensities and biasing conditions, along with spectral-response characteristics, and threshold voltage stability characterization demonstrate the feasibility of the phototransistor for low light level detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A evolução da tecnologia CMOS tem possibilitado uma maior densidade de integração de circuitos tornando possível o aumento da complexidade dos sistemas. No entanto, a integração de circuitos de gestão de potência continua ainda em estudo devido à dificuldade de integrar todos os componentes. Esta solução apresenta elevadas vantagens, especialmente em aplicações electrónicas portáteis alimentadas a baterias, onde a autonomia é das principais características. No âmbito dos conversores redutores existem várias topologias de circuitos que são estudadas na área de integração. Na categoria dos conversores lineares utiliza-se o LDO (Low Dropout Regulator), apresentando no entanto baixa eficiência para relações de conversão elevadas. Os conversores comutados são elaborados através do recurso a circuitos de comutação abrupta, em que a eficiência deste tipo de conversores não depende do rácio de transformação entre a tensão de entrada e a de saída. A diminuição física dos processos CMOS tem como consequência a redução da tensão máxima que os transístores suportam, impondo o estudo de soluções tolerantes a “altatensão”, com o intuito de manter compatibilidade com tensões superiores que existam na placa onde o circuito é incluído. Os sistemas de gestão de energia são os primeiros a acompanhar esta evolução, tendo de estar aptos a fornecer a tensão que os restantes circuitos requerem. Neste trabalho é abordada uma metodologia de projecto para conversores redutores CCCC comutados em tecnologia CMOS, tendo-se maximizado a frequência com vista à integração dos componentes de filtragem em circuito integrado. A metodologia incide sobre a optimização das perdas totais inerentes à comutação e condução, dos transístores de potência e respectivos circuitos auxiliares. É apresentada uma nova metodologia para o desenvolvimento de conversores tolerantes a “alta-tensão”.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optically addressed read-write sensor based on two stacked p-i-n heterojunctions is analyzed. The device is a two terminal image sensing structure. The charge packets are injected optically into the p-i-n writer and confined at the illuminated regions changing locally the electrical field profile across the p-i-n reader. An optical scanner is used for charge readout. The design allows a continuous readout without the need for pixel-level patterning. The role of light pattern and scanner wavelengths on the readout parameters is analyzed. The optical-to-electrical transfer characteristics show high quantum efficiency, broad spectral response, and reciprocity between light and image signal. A numerical simulation supports the imaging process. A black and white image is acquired with a resolution around 20 mum showing the potentiality of these devices for imaging applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microcrystalline silicon is a two-phase material. Its composition can be interpreted as a series of grains of crystalline silicon imbedded in an amorphous silicon tissue, with a high concentration of dangling bonds in the transition regions. In this paper, results for the transport properties of a mu c-Si:H p-i-n junction obtained by means of two-dimensional numerical simulation are reported. The role played by the boundary regions between the crystalline grains and the amorphous matrix is taken into account and these regions are treated similar to a heterojunction interface. The device is analysed under AM1.5 illumination and the paper outlines the influence of the local electric field at the grain boundary transition regions on the internal electric configuration of the device and on the transport mechanism within the mu c-Si:H intrinsic layer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The rapid growth of the rubella virus in RC-IAL² with development of cytopathic effect, in response to rubella virus infection, is described. For purposes of comparison, the rubella virus RA-27/3 strain was titered simultaneously in the RC-IAL, Vero, SIRC and RK13 cell lines. METHODS: Rubella virus RA-27/3 strain are inoculated in the RC-IAL cell line (rabbit Kidney, Institute Adolfo Lutz). Plates containing 1.5x10(5) cells/ml of RC-IAL line were inoculated with 0.1ml s RA-27/3 strain virus containing 1x 10(4)TCID50/0.1ml. A 25% cytopathic effect was observed after 48 hours and 100% after 96 hours. The results obtained were compared to those observed with the SIRC, Vero and RK13 cell lines. Rubella virus was detected by immunohistochemistry. RESULTS: With the results, it was possible to conclude that the RC-IAL cell line is a very good substrate for culturing rubella virus. The cells inoculated with rubella virus were examined by phase contrast microscopy and showed the characteristic rounded, bipolar and multipolar cells. The CPE in RC-IAL was observed in the first 48 hours and the curve of the increased infectivity was practically the same as observed in other cell lines. CONCLUSIONS: These findings are important since this is one the few cell lines described in the literature with a cytopathic effect. So it can be used for antigen preparation and serological testing for the diagnosis of specific rubella antibodies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A mitose é o evento celular, através do qual uma células transmite uma cópias do seu DNA às células filhas. Este processo é mediado pelo fuso mitótico, o qual consiste numa rede bipolar microtubulos. A dinâmica dos microtubulos é regulada por proteínas associadas a estes (MAPs – Microtubule-Associated Proteins), tais como as proteínas associadas às extremidades positivas dos microtubulos (+TIPs – Plus-ends Tracking proteins). As proteínas associadas às CLIPs (CLASPs – CLIP-associated proteins) pertencem a esta família e estão altamente conservadas nos eucariotas. Estas interagem com os microtubulos regulando o fuso mitótico, a segregação dos cromossomas e o comportamento dos microtubulos ao nível do cinetocoro. Assim, as CLASPs têm sido descritas como essenciais à manutenção da integridade genética durante a divisão celular. Um modelo animal knockout para o gene Clasp1 é uma ferramenta indispensável à descoberta do papel da CLASP1 a nível fisiológico. Nos animais knockout foi observado um fenótipo letal, no qual 100% dos recém-nascidos morreram poucos minutos após o nascimento, no decurso de falência respiratória. Após análise histopatológica, observamos que os pulmões dos animais knockout apresentam um atraso no desenvolvimento. Porém, a análise da expressão de marcadores de diferenciação celular, mostrou que os pneumócitos tipo I e II estão presente e diferenciados nos animais knockout aquando do seu nascimento. No entanto, um defeito primário a nível pulmonar ainda não pode ser excluído. Níveis elevados de glicogénio no parênquima alveolar dos animais knockout sugerem imaturidade pulmonar ou deficiente produção do líquido surfactante. Adicionalmente, ainda não está esclarecido de que forma pode este atraso explicar a letalidade observada nos recémnascidos knockout. Verificamos também que expressão de CLASP1 é transiente ao longo do desenvolvimento, sendo particularmente elevada no cérebro, o que pode explicar o seu papel já descrito na biologia dos neurónios. A CLASP1 é ubiquamente expressa em mamíferos adultos, o que sugere que esta proteína é também importante em tecidos diferenciados. Nesta fase, o significado biológico da CLASP1 em mamíferos ainda não foi descortinado. No entanto, nenhum animal knockout para Clasp1 foi capaz de sobreviver ex uterus, o que sugere um papel fundamental desta proteína na fase final do desenvolvimento dos mamíferos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a step-up micro-power converter for solar energy harvesting applications. The circuit uses a SC voltage tripler architecture, controlled by an MPPT circuit based on the Hill Climbing algorithm. This circuit was designed in a 0.13 mu m CMOS technology in order to work with an a-Si PV cell. The circuit has a local power supply voltage, created using a scaled down SC voltage tripler, controlled by the same MPPT circuit, to make the circuit robust to load and illumination variations. The SC circuits use a combination of PMOS and NMOS transistors to reduce the occupied area. A charge re-use scheme is used to compensate the large parasitic capacitors associated to the MOS transistors. The simulation results show that the circuit can deliver a power of 1266 mu W to the load using 1712 mu W of power from the PV cell, corresponding to an efficiency as high as 73.91%. The simulations also show that the circuit is capable of starting up with only 19% of the maximum illumination level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Toxic amides, such as acrylamide, are potentially harmful to Human health, so there is great interest in the fabrication of compact and economical devices to measure their concentration in food products and effluents. The CHEmically Modified Field Effect Transistor (CHEMFET) based onamorphous silicon technology is a candidate for this type of application due to its low fabrication cost. In this article we have used a semi-empirical modelof the device to predict its performance in a solution of interfering ions. The actual semiconductor unit of the sensor was fabricated by the PECVD technique in the top gate configuration. The CHEMFET simulation was performed based on the experimental current voltage curves of the semiconductor unit and on an empirical model of the polymeric membrane. Results presented here are useful for selection and design of CHEMFET membranes and provide an idea of the limitations of the amorphous CHEMFET device. In addition to the economical advantage, the small size of this prototype means it is appropriate for in situ operation and integration in a sensor array.