687 resultados para Fibrilação atrial


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Rhythm disturbances in children with structurally normal hearts are usually associated with abnormalities in cardiac ion channels. The phenotypic expression of these abnormalities ("channelopathies") includes: long and short QT syndromes, Brugada syndrome, congenital sick sinus syndrome, catecholaminergic polymorphic ventricular tachycardia, Lènegre-Lev disease, and/or different degrees of cardiac conduction disease. METHODS The study group consisted of three male patients with sick sinus syndrome, intraventricular conduction disease, and monomorphic sustained ventricular tachycardia. Clinical data and results of electrocardiography, Holter monitoring, electrophysiology, and echocardiography are described. RESULTS In all patients, the ECG during sinus rhythm showed right bundle branch block and long QT intervals. First-degree AV block was documented in two subjects, and J point elevation in one. A pacemaker was implanted in all cases due to symptomatic bradycardia (sick sinus syndrome). Atrial tachyarryhthmias were observed in two patients. The common characteristic ventricular arrhythmia was a monomorphic sustained ventricular tachycardia, inducible with ventricular stimulation and sensitive to lidocaine. In one patient, radiofrequency catheter ablation was successfully performed. No structural abnormalities were found in echocardiography in the study group. CONCLUSION Common clinical and ECG features suggest a common pathophysiology in this group of patients with congenital severe electrical disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

UNLABELLED The automatic implantable defibrillator (AID) is the treatment of choice for primary and secondary prevention of sudden death. At the Instituto Nacional de Cardiología, since October 1996 until January 2002, 25 patients were implanted with 26 AID. There were 23 men (92%) and the mean age of the whole group, was 51.4 years. Twenty-three patients (92%) presented structural heart disease, the most common was ischemic heart disease in 13 patients (52%), with a mean ejection fraction of 37.8%. One patient without structural heart disease had Brugada Syndrome. The most frequent clinical arrhythmia was ventricular tachycardia in 14 patients (56%). The mean follow-up was of 29.3 months during which a total of 30 events of ventricular arrhythmia were treated through AID; six of them were inappropriate due to paroxismal atrial fibrillation; 10 AID patients (34%) have not applied for therapy. Three patients (12%) of the group died due to congestive heart failure refractory to pharmacologic treatment. CONCLUSION The implant of the AID is a safe and effective measure for primary and secondary prevention of sudden death. World-wide experience evidences, that this kind of device has not modified the mortality rate due to heart failure in these patients, but it has diminished sudden arrhythmic death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The electrocardiographic PR interval increases with aging, differs by race, and is associated with atrial fibrillation (AF), pacemaker implantation, and all-cause mortality. We sought to determine the associations between PR interval and heart failure, AF, and mortality in a biracial cohort of older adults. METHODS AND RESULTS The Health, Aging, and Body Composition (Health ABC) Study is a prospective, biracial cohort. We used multivariable Cox proportional hazards models to examine PR interval (hazard ratios expressed per SD increase) and 10-year risks of heart failure, AF, and all-cause mortality. Multivariable models included demographic, anthropometric, and clinical variables in addition to established cardiovascular risk factors. We examined 2722 Health ABC participants (aged 74±3 years, 51.9% women, and 41% black). We did not identify significant effect modification by race for the outcomes studied. After multivariable adjustment, every SD increase (29 ms) in PR interval was associated with a 13% greater 10-year risk of heart failure (95% confidence interval, 1.02-1.25) and a 13% increased risk of incident AF (95% confidence interval, 1.04-1.23). PR interval >200 ms was associated with a 46% increased risk of incident heart failure (95% confidence interval, 1.11-1.93). PR interval was not associated with increased all-cause mortality. CONCLUSIONS We identified significant relationships of PR interval to heart failure and AF in older adults. Our findings extend prior investigations by examining PR interval and associations with adverse outcomes in a biracial cohort of older men and women.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The association between subclinical thyroid dysfunction and cardiovascular outcomes has been recently clarified with the publication of three individual participant data (IPD) analyses from the Thyroid Studies Collaboration. We identified original cohort studies with a systematic review and pooled individual data from over 70'000 participants to obtain a more precise estimate of the risks of cardiovascular outcomes associated with subclinical thyroid dysfunction. Subclinical hypothyroidism and subclinical hyperthyroidism, defined as normal thyroxine (FT4) levels with increased or decreased Thyroid-Stimulating Hormones (TSH or thyrotropin) respectively, are associated with increased risk of cardiovascular outcomes compared to euthyroid state, particularly in those with a more pronounced thyroid dysfunction. Specifically, subclinical hypothyroidism is associated with an increased risk of coronary heart disease (CHD) events, CHD mortality and heart failure (HF) events in individuals with higher TSH levels, particularly in those with TSH levels ≥10.0 mIU/L. Conversely, subclinical hyperthyroidism is associated with an increased risk of total mortality, CHD mortality, HF and atrial fibrillation, particularly in those with suppressed TSH levels <0.10 mIU/L. Pending ongoing randomized controlled trials, these observational findings allow identifying potential TSH thresholds for thyroid medication initiation based on risk of clinical outcomes, although clinical decision based solely on observational data need caution. The impact of thyroid replacement among the elderly with subclinical hypothyroidism is currently studied in a multicenter international randomized controlled trial (Thyroid Hormone Replacement for Subclinical Hypothyroidism Trial, TRUST trial).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: New oral anticoagulants (NOACs) are predicted to become the new standard treatment for stroke prevention in patients with atrial fibrillation, and may replace vitamin K antagonists (VKAs). NOACs are prescribed less than expected, even though they do not require international normalised ratio (INR) monitoring. In this study we assessed methods for INR monitoring after the introduction of NOACs a in heterogeneous sample of countries. Methods: We asked representatives of the Vasco da Gama Movement, a network of junior and future gen- eral practitioners (GPs) in Europe, and WONCA, the World Organization of Family Doctors, to describe the way INR is monitored in their respective countries. Results: Representatives of 14 countries responded. In most countries, the INR is monitored by GPs; in some countries, these patients are treated by other specialists or in specialised anticoagulation centres. In only a few countries, anticoagulated patients monitor the INR themselves. Conclusion: Our study showed several strategies for managing anticoagulation in different countries. In most countries, the INR is monitored by GPs. These consultations offer opportunities to address other is- sues, such as blood pressure control or medication adherence. These factors may be considered when de- ciding to switch patients from VKAs to NOACs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE In patients with hormone-dependent postmenopausal breast cancer, standard adjuvant therapy involves 5 years of the nonsteroidal aromatase inhibitors anastrozole and letrozole. The steroidal inhibitor exemestane is partially non-cross-resistant with nonsteroidal aromatase inhibitors and is a mild androgen and could prove superior to anastrozole regarding efficacy and toxicity, specifically with less bone loss. PATIENTS AND METHODS We designed an open-label, randomized, phase III trial of 5 years of exemestane versus anastrozole with a two-sided test of superiority to detect a 2.4% improvement with exemestane in 5-year event-free survival (EFS). Secondary objectives included assessment of overall survival, distant disease-free survival, incidence of contralateral new primary breast cancer, and safety. RESULTS In the study, 7,576 women (median age, 64.1 years) were enrolled. At median follow-up of 4.1 years, 4-year EFS was 91% for exemestane and 91.2% for anastrozole (stratified hazard ratio, 1.02; 95% CI, 0.87 to 1.18; P = .85). Overall, distant disease-free survival and disease-specific survival were also similar. In all, 31.6% of patients discontinued treatment as a result of adverse effects, concomitant disease, or study refusal. Osteoporosis/osteopenia, hypertriglyceridemia, vaginal bleeding, and hypercholesterolemia were less frequent on exemestane, whereas mild liver function abnormalities and rare episodes of atrial fibrillation were less frequent on anastrozole. Vasomotor and musculoskeletal symptoms were similar between arms. CONCLUSION This first comparison of steroidal and nonsteroidal classes of aromatase inhibitors showed neither to be superior in terms of breast cancer outcomes as 5-year initial adjuvant therapy for postmenopausal breast cancer by two-way test. Less toxicity on bone is compatible with one hypothesis behind MA.27 but requires confirmation. Exemestane should be considered another option as up-front adjuvant therapy for postmenopausal hormone receptor-positive breast cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclic nucleotide-gated (CNG) channels are a family of ion channels activated by the binding of cyclic nucleotides. Endogenous channels have been used to measure cyclic nucleotide signals in photoreceptor outer segments and olfactory cilia for decades. Here we have investigated the subcellular localization of cGMP signals by monitoring CNG channel activity in response to agonists that activate either particulate or soluble guanylyl cyclase. CNG channels were heterologously expressed in either human embryonic kidney (HEK)-293 cells that stably overexpress a particulate guanylyl cyclase (HEK-NPRA cells), or cultured vascular smooth muscle cells (VSMCs). Atrial natriuretic peptide (ANP) was used to activate the particulate guanylyl cyclase and the nitric oxide donor S-nitroso-n-acetylpenicillamine (SNAP) was used to activate the soluble guanylyl cyclase. CNG channel activity was monitored by measuring Ca2+ or Mn2+ influx through the channels using the fluorescent dye, fura-2. We found that in HEK-NPRA cells, ANP-induced increases in cGMP levels activated CNG channels in a dose-dependent manner (0.05-10 nM), whereas SNAP (0.01-100 microM) induced increases in cGMP levels triggered little or no activation of CNG channels (P < 0.01). After pretreatment with 100 microM 3-isobutyl-1-methylxanthine (IBMX), a nonspecific phosphodiesterase inhibitor, ANP-induced Mn2+ influx through CNG channels was significantly enhanced, while SNAP-induced Mn2+ influx remained small. In contrast, we found that in the presence of IBMX, both 1 nM ANP and 100 microM SNAP triggered similar increases in total cGMP levels. We next sought to determine if cGMP signals are compartmentalized in VSMCs, which endogenously express particulate and soluble guanylyl cyclase. We found that 10 nM ANP induced activation of CNG channels more readily than 100 muM SNAP; whereas 100 microM SNAP triggered higher levels of total cellular cGMP accumulation. These results suggest that cGMP signals are spatially segregated within cells, and that the functional compartmentalization of cGMP signals may underlie the unique actions of ANP and nitric oxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

C-Reactive Protein (CRP) is a biomarker indicating tissue damage, inflammation, and infection. High-sensitivity CRP (hsCRP) is an emerging biomarker often used to estimate an individual’s risk for future coronary heart disease (CHD). hsCRP levels falling below 1.00 mg/l indicate a low risk for developing CHD, levels ranging between 1.00 mg/l and 3.00 mg/l indicate an elevated risk, and levels exceeding 3.00 mg/l indicate high risk. Multiple Genome-Wide Association Studies (GWAS) have identified a number of genetic polymorphisms which influence CRP levels. SNPs implicated in such studies have been found in or near genes of interest including: CRP, APOE, APOC, IL-6, HNF1A, LEPR, and GCKR. A strong positive correlation has also been found to exist between CRP levels and BMI, a known risk factor for CHD and a state of chronic inflammation. We conducted a series of analyses designed to identify loci which interact with BMI to influence CRP levels in a subsample of European-Americans in the ARIC cohort. In a stratified GWA analysis, 15 genetic regions were identified as having significantly (p-value < 2.00*10-3) distinct effects on hsCRP levels between the two obesity strata: lean (18.50 kg/m2 < BMI < 24.99 kg/m2) and obese (BMI ≥ 30.00 kg/m2). A GWA analysis performed on all individuals combined (i.e. not a priori stratified for obesity status) with the inclusion of an additional parameter for BMI by gene interaction, identified 11 regions which interact with BMI to influence hsCRP levels. Two regions containing the genes GJA5 and GJA8 (on chromosome 1) and FBXO11 (on chromosome 2) were identified in both methods of analysis suggesting that these genes possibly interact with BMI to influence hsCRP levels. We speculate that atrial fibrillation (AF), age-related cataracts and the TGF-β pathway may be the biological processes influenced by the interaction of GJA5, GJA8 and FBXO11, respectively, with BMI to cause changes in hsCRP levels. Future studies should focus on the influence of gene x bmi interaction on AF, age-related cataracts and TGF-β.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glomerular mesangial cells (MC) are renal vascular cells that regulate the surface area of glomerular capillaries and thus, partly control glomerular filtration rate. Clarification of the signal transduction pathways and ionic mechanisms modulating MC tone are critical to understanding the physiology and pathophysiology of these cells, and the integrative role these cells play in fluid and electrolyte homeostasis. The patch clamp technique and an assay of cell concentration were used to electrophysiologically and pharmacologically analyze the ion channels of the plasmalemmal of human glomerular MC maintained in tissue culture. Moreover, the signal transduction pathways modulating channels involved in relaxation were investigated. Three distinct K$\sp+$-selective channels were identified: two low conductance channels (9 and 65pS) maintained MC at rest, while a larger conductance (206pS) K$\sp+$ channel was quiescent at rest. This latter channel was pharmacologically and biophysically similar to the large, Ca$\sp{2+}$-activated K$\sp+$ channel (BK$\rm\sb{Ca}$) identified in smooth muscle. BK$\rm\sb{Ca}$ played an essential role in relaxation of MC. In cell-attached patches, the open probability (P$\rm\sb{o}$) of BK$\rm\sb{Ca}$ increased from a basal level of $<$0.05 to 0.22 in response to AII (100nM)-induced mobilization of cytosolic Ca$\sp{2+}$. Activation in response to contractile signals (membrane depolarization and Ca$\sp{2+}$ mobilization) suggests that BK$\rm\sb{Ca}$ acts as a low gain feedback regulator of contraction. Atrial natriuretic factor (ANF; 1.0$\mu$M) and nitroprusside (NP; 0.1mM), via the second messenger, cGMP, increase the feedback gain of BK$\rm\sb{Ca}$. In cell-attached patches bathed with physiological saline, these agents transiently activated BK$\rm\sb{Ca}$ from a basal $\rm P\sb{o}<0.05$ to peak responses near 0.50. As membrane potential hyperpolarizes towards $\rm E\sb{K}$ (2-3 minutes), BK$\rm\sb{Ca}$ inactivates. Upon depolarizing V$\rm\sb{m}$ with 140 mM KCl, db-cGMP (10$\mu$M) activated BK$\rm\sb{Ca}$ to a sustained P$\rm\sb{o}$ = 0.51. Addition of AII in the presence of cGMP further increased P$\rm\sb{o}$ to 0.82. Activation of BK$\rm\sb{Ca}$ by cGMP occured via an endogenous cGMP-dependent protein kinase (PKG): in excised, inside-out patches, PKG in the presence of Mg-ATP (0.1mM) and cGMP increased P$\rm\sb{o}$ from 0.07 to 0.39. In contrast, neither PKC nor PKA influenced BK$\rm\sb{Ca}$. Endogenous okadaic acid-sensitive protein phosphatase suppressed BK$\rm\sb{Ca}$ activity. Binning the change in P$\rm\sb{o}\ (\Delta P\sb{o}$) of BK$\rm\sb{Ca}$ in response to PKG (n = 69) established two distinct populations of channels: one that responded ($\cong$67%, $\rm\Delta P\sb{o} = 0.45 \pm 0.03$) and one that was unresponsive ($\Delta\rm P\sb{o} = 0.00 \pm 0.01$) to PKG. Activation of BK$\rm\sb{Ca}$ by PKG resulted from a decrease in the Ca$\sp{2+}$- and voltage-activation thresholds independent of sensitivities. In conclusion, mesangial BK$\rm\sb{Ca}$ channels sense both electrical and chemical signals of contraction and act as feedback regulators by repolarizing the plasma membrane. ANF and NO, via cGMP, stimulate endogenous PKG, which subsequently decreases the activation threshold of BK$\rm\sb{Ca}$ to increase the gain of this feedback regulatory signal. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patient self-management (PSM) of oral anticoagulation is under discussion, because evidence from real-life settings is missing. Using data from a nationwide, prospective cohort study in Switzerland, we assessed overall long-term efficacy and safety of PSM and examined subgroups. Data of 1140 patients (5818.9 patient-years) were analysed and no patient were lost to follow-up. Median follow-up was 4.3 years (range 0.2-12.8 years). Median age at the time of training was 54.2 years (range 18.2-85.2) and 34.6% were women. All-cause mortality was 1.4 per 100 patient-years (95% CI 1.1-1.7) with a higher rate in patients with atrial fibrillation (2.5; 1.6-3.7; p<0.001), patients>50 years of age (2.0; 1.6-2.6; p<0.001), and men (1.6; 1.2-2.1; p = 0.036). The rate of thromboembolic events was 0.4 (0.2-0.6) and independent from indications, sex and age. Major bleeding were observed in 1.1 (0.9-1.5) per 100 patient-years. Efficacy was comparable to standard care and new oral anticoagulants in a network meta-analysis. PSM of properly trained patients is effective and safe in a long-term real-life setting and robust across clinical subgroups. Adoption in various clinical settings, including those with limited access to medical care or rural areas is warranted.