928 resultados para Elastic Modulus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effects of elastic tubing training compared with conventional resistance training on the improvement of functional exercise capacity, muscle strength, fat-free mass, and systemic inflammation in patients with chronic obstructive pulmonary disease.Design: A prospective, randomized, eight-week clinical trial.Setting: The study was conducted in a university-based, outpatient, physical therapy clinic.Subjects: A total of 49 patients with moderate chronic obstructive pulmonary disease.Interventions: Participants were randomly assigned to perform elastic tubing training or conventional resistance training three times per week for eight weeks.Main measures: The primary outcome measure was functional exercise capacity. The secondary outcome measures were peripheral muscle strength, health-related quality of life assessed by the Chronic Respiratory Disease Questionnaire (CRDQ), fat-free mass, and cytokine profile.Results: After eight weeks, the mean distance covered during six minutes increased by 73 meters (69) in the elastic tubing group and by 42 meters (+/- 59) in the conventional group (p < 0.05). The muscle strength and quality of life improved in both groups (P < 0.05), with no significant differences between the groups. There was a trend toward an improved fat-free mass in both groups (P = 0.05). After the first and last sessions, there was an increase in interleukin 1 (IL-1) and interleukin 10 (IL-10) in both groups, while tumour necrosis factor alpha (TNF-) was stimulated only in the conventional training group.Conclusion: Elastic tubing training had a greater effect on functional exercise capacity than conventional resistance training. Both interventions were equally effective in improving muscle strength and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and Objective: The synthetic intermaxillary elastic emerged as an alternative for clinical use in patients with latex sensitivity. However, there are disagreements about this elastic protocol use according to the force degradation. The aim of this study was to evaluate, in vitro, the forces generated by latex and synthetic elastics over time. Material and methods: Sample size of 840 elastics were used (420 latex and 420 synthetic), delivering medium strength (Dental Morelli®) with internal diameter of 1/8”, 3/16”, 1/4” and 5/16”. The elastics were randomly divided into 7 groups according to the time of the force measuring and immersed into distilled water at 37°C. To measure the force in each group, the elastics were stretched in six progressive increases of 100% of its internal diameter with the aid of a testing machine Emic and measured up to 72 hours. Data were analyzed with SPSS 16.0, using one-way analysis of variance (ANOVA). Results: Immediate force level of synthetic elastics was statistically higher than latex elastics in all strains, for the same size. However, the latex elastics mean force slightly decreased over time, while the synthetic elastics presented an abrupt decrease. Conclusion: The synthetic elastic presented severe force degradation, jeopardizing the cost-benefit ratio, which indicates a higher replacement frequency. The latex elastic showed better mechanical performance in comparison to synthetic ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A time reversal symmetric regularized electron exchange model was used to elastic scattering, target elastic Ps excitations and target inelastic excitation of hydrogen in a five state coupled model. A singlet Ps-H-S-wave resonance at 4.01 eV of width 0.15 eV and a P-wave resonance at 5.08 eV of width 0.004 eV were obtained using this model. The effect on the convergence of the coupled-channel scheme due to the inclusion of the excited Ps and H states was also analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The composite SmBa2Cu3O7-delta (Sm-123), obtained by the substitution of the ion Y for Sm in the very well known and studied YBa2Cu3O7-delta (Y-123), is potentially attractive for better understanding superconductivity mechanisms and for its applications as electronic devices. Sm-123 samples show higher critical temperatures than Y-123 ones do and a larger solubility of Sm in Ba-Cu-O solvent, which makes their growth process faster. When oxygen is present interstitially, it strongly affects the physical properties of the material. The dynamics of oxygen can be investigated by anelastic spectroscopy measurements, a powerful technique for the precise determination of the oscillation frequency and the internal friction when atomic jumps are possible. Anelastic spectroscopy allows determining the elasticity modulus (related to the oscillation frequency) and the elastic energy loss (related to the internal friction) as a function of the temperature. The sample was also investigated by X-ray diffraction (XRD), scanning electronic microscopy (SEM), and electric resistivity. The results obtained show a thermally activated relaxation structure composed by at least 3 relaxation processes. These processes may be attributed to the jumps of oxygen atoms present of the Cu-O plane in the orthorhombic phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This study reports a case in which elastic band use culminated in the loss of the incisors. Case Report. An 11-year-old white girl was seen complaining of pain, with purulent discharge and severe tooth mobility. The bone destruction detected radiographically in the region, despite its single location and absence in posterior quadrants of the maxilla and/or mandible, was similar to that observed in Langerhans cell disease. To our surprise, an elastic band involving the midportion of the roots of the two upper central incisors was found during biopsy. The debris was removed and a metal wire was placed in permanent maxillary right and left incisors. The patient was followed up, but no improvement in tooth mobility was observed. Bone loss increased, and internal resorption and root exposure occurred, which culminated in the extraction of permanent maxillary right and left incisors. Conclusion. The present case highlights the fact that professionals sometimes are confronted by anamnestic reports never seen before.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periodically, when necessary, standard documents are revised in order to analyze inconsistencies and to include considerations according new realities verified. In this sense, aiming to quantify the wood moisture content influence on modulus of elasticity, it was applied tension tests parallel to the grain for six specimens of different strength classes of wood, considering nominal moisture of 12, 20, 25, and 30% in Brazil. The present paper examine the adequacy of the current Brazilian standard ABNT NBR7190:1997, in review, about the adoption of a first degree equation to describe the influence of wood moisture content for timber structures design. It was obtained a new first degree equation which leads to statically equivalent estimations when compared with results by ABNT NBR7190:1997 equation. However, as recommendations it could be maintain the current expression for the next text of the referred document review, without prejudice to statistical significance of the estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Cone Loading Test (CLT) consists of the execution of a load test on the piezocone probe in conjunction with the CPT test. The CLT yields the modulus ECLT, a parameter that can be used in the estimative of foundation settlement. It is also presented here the interpretation and the process to determine ECLT values from the stress-displacement curves obtained from cone loading tests. Several CLT tests were conducted at the experimental research site of São Paulo State University, Bauru-SP-Brazil. The geotechnical profile at the studied site is a brown to bright red slightly clayey fine sand, a tropical soil common to this region which is lateritic, unsaturated and collapsible. The results of CLT tests satisfactorily represent the behavior of the investigated soil. The penetrometric modulus ECLT for each depth was calculated considering the elastic behavior in the initial linear segment of the soil stress-strain curve. The ECLT moduli obtained for the various tests were compared to moduli obtained from PMT and DMT test results performed at same studied site. The shear modulus degradation curves obtained from the CLT tests are also presented. The comparison to PMT and DMT results indicates the CLT test is a viable complementary test to the CPT in the quest for better understanding stress-strain behavior of soils. Further, the CLT test provides a graphic visualization of the degradation of the shear modulus with increasing levels of strain. As a hybrid geotechnical test, CPT+CLT can be valuable in the investigation of non-conventional collapsible soils, whose literature lack reference parameters for the prediction of settlement in the design of foundations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronic and structural properties and elastic constants of the wurtzite phase of GaN, was investigated by computer simulation at Density Functional Theory level, with B3LYP and B3PW hybrid functional. The electronic properties were investigated through the analysis of the band structures and density of states, and the mechanical properties were studied through the calculus of the elastic constants: C11, C33, C44, C12, and C13. The results show that the maximum of the valence band and the minimum of the conduction band are both located at the Γ point, indicating that GaN is a direct band gap semiconductor. The following constants were obtained for B3LYP and B3PW (in brackets): C11 = 366.9 [372.4], C33 = 390.9 [393.4], C44 = 99.1 [96.9], C12 = 143.6 [155.2], and C13 = 107.6 [121.4].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study focuses on analysing the effects of nonlinear torsional stiffness on the dynam-ics of a slender elastic beam under torsional oscillations, which can be subject to helical buckling.The helical buckling of an elastic beam confined in a cylinder is relevant to many applications. Someexamples include oil drilling, medical cateters and even the conformation and functioning of DNAmolecules. A recent study showed that the formation of the helical configuration is a result of onlythe torsional load, confirming that there is a different path to helical buckling which is not related tothe sinusoidal buckling, stressing the importance of the geometrical behaviour of the beam. A lowdimensional model of an elastic beam under torsional oscillations is used to analyse its dynamical be-haviour with different stiffness characteristics, which are present before and after the helical buckling.Hardening and softening characteristics are present, as the effects of torsion and bending are coupled.With the use of numerical algorithms applied to nonlinear dynamics, such as bifurcation diagramsand basins of attraction, it is shown that the nonlinear stiffness can shift the bifurcations and inducechanges in the stability of the desirable and undesirable solutions. Therefore, the proper modellingof these stiffness nonlinearities seems to be important for a better understanding of the dynamicalbehaviour of such beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modulus of elasticity is an important property for the behavior analysis of concrete structures. This research evaluated the strain difference between concrete specimens with and without the application of laminate carbon fiber composites as well as the variation time, in months, of the axial strength compression and modulus of elasticity. Through the experimental results, it is concluded that increases in compressive strength and modulus of elasticity are more significant in the specimens without reinforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Degeneration of tendon tissue is a common cause of tendon dysfunction with the symptoms of repeated episodes of pain and palpable increase of tendon thickness. Tendon mechanical properties are directly related to its physiological composition and the structural organization of the interior collagen fibers which could be altered by tendon degeneration due to overuse or injury. Thus, measuring mechanical properties of tendon tissue may represent a quantitative measurement of pain, reduced function, and tissue health. Ultrasound elasticity imaging has been developed in the last two decades and has proved to be a promising tool for tissue elasticity imaging. To date, however, well established protocols of tendinopathy elasticity imaging for diagnosing tendon degeneration in early stages or late stages do not exist. This thesis describes the re-creation of one dynamic ultrasound elasticity imaging method and the development of an ultrasound transient shear wave elasticity imaging platform for tendon and other musculoskeletal tissue imaging. An experimental mechanical stage with proper supporting systems and accurate translating stages was designed and made. A variety of high-quality tissue-mimicking phantoms were made to simulate homogeneous and heterogeneous soft tissues as well as tendon tissues. A series of data acquisition and data processing programs were developed to collect the displacement data from the phantom and calculate the shear modulus and Young’s modulus of the target. The imaging platform was found to be capable of conducting comparative measurements of the elastic parameters of the phantoms and quantitatively mapping elasticity onto ultrasound B-Mode images. This suggests the system has great potential for not only benefiting individuals with tendinopathy with an earlier detection, intervention and better rehabilitation, but also for providing a medical tool for quantification of musculoskeletal tissue dysfunction in other regions of the body such as the shoulder, elbow and knee.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows the results of an experimental investigation carried out on a connection element of glulam and concrete composite structures, through double-sided push-out shear tests. The connection system was composed of perforated steel plates glued with epoxy adhesive. Five specimens were made and tested under shear forces. This innovative connection system showed an average initial slip modulus equivalent to 339.4 kN/mm. In addition, the connection system was evaluated by means of numerical simulations and the software ANSYS was used for this purpose. The numerical simulations demonstrated good agreement with the experimental data, especially in the regime of elastic-linear behavior of materials. (C) 2011 Elsevier Ltd. All rights reserved.