1000 resultados para Determinação de minoxidil


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrode for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Itraconazole is a synthetic antifungal drug administered orally with a broad spectrum of activity against mycotic infections. The present work consists of the development and validation of analytical methodology for evaluation of itraconazole in pharmaceutical products by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/diethylamine 0.05% v/v, 60:40 v/v, pH 8.0 as mobile phase, methanol as solvent and detection and quantification at 254 nm. The results here obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 8.0-12.0 µg/mL of itraconazole. The method was applied to pharmaceutical capsules containg itraconazole pellets and showed to be efficient, yielding good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main analytical variables of a modified Folin-Ciocalteu method were studied by UV-Vis and gradient HPLC-PDA methods, using purified (PC) and technical grade (TGC) casein. Rutin and an aqueous extract of Psidium guajava L. leaves were used as models. The best results were ascribed to TGC. Certainly PC bonds the polyphenols of the P. guajava extract better than TGC, but TGC afforded better precision. A lack of specificity occurred when rutin was analyzed together with the P guajava extract. Additional analyses performed with the flavonoid fraction of P. guajava extract by HPLC-PDA had confirmed that casein was able to bind catechin, gallic acid and P. guajava flavonoids in a non-specific way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical procedures used for determining the concentrations and isotope composition of strontium in subsurface waters, by mass spectrometry, are described. Sampling was performed in coastal plateaus, salt marsh and mangrove environments in the coastal region of Pará. Coastal plateau waters have delta87Sr between 1.51 and 6.26‰ and Sr concentration bellow 58 ppb. Salt marsh waters show delta87Sr between 0.55 and 0.90‰ and Sr concentration between 93 and 114 ppm, while mangrove waters have delta87Sr‰ around zero and Sr concentration above 15 ppm. Differences in the 87Sr/86Sr ratio in these subsurface waters are detected, as well as seasonal variations in the coastal pleteau waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cleaning solutions containing EDTA are widely employed to remove incrustation despite of the costs involved. The free content of EDTA in commercial solutions may be determined by mixing an aliquot to ammonium oxalate and using a standard calcium solution as titrant. The end-point is detected by the formation of insoluble calcium oxalate after all EDTA is complexed. A system for turbidimetric detection of the end-point was envisaged to substitute the visual detection, which impaired the analyses of dark samples. The proposed method was tested with real samples and good accuracy and precision was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfur emission in coal power generation is a matter of great environmental concern and limestone sorbents are widely used for reducing such emissions. Thermogravimetry was applied to determine the effects of the type of limestone (calcite and dolomite), particle size (530 and 650 µm) and atmosphere (air and nitrogen) on the kinetics of SO2 sorption by limestone. Isothermal experiments were performed for different temperatures (650 to 950 ºC), at local atmospheric pressure. The apparent activation energies, as indicated by the slope of the Arrhenius plot, resulted between 3.03 and 4.45 kJ mol-1 for the calcite, and 11.24 kJ mol-1 for the dolomite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review here the chemistry of reactive oxygen and nitrogen species, their biological sources and targets; particularly, biomolecules implicated in the redox balance of the human blood, and appraise the analytical methods available for their detection and quantification. Those biomolecules are represented by the enzymatic antioxidant defense machinery, whereas coadjutant reducing protection is provided by several low molecular weight molecules. Biomolecules can be injured by RONS yielding a large repertoire of oxidized products, some of which can be taken as biomarkers of oxidative damage. Their reliable determination is of utmost interest for their potentiality in diagnosis, prevention and treatment of maladies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to investigate the copper electrode behavior in the voltammetric determination of glyphosate. The best conditions for this determination are phosphate buffer 0.05 mol L-1 and pH 7.3, and the peak potential is observed at 187 mV. LD and LQ values are 59 µg L-1 e 196 µg L-1, respectively. A water sample was analysed for glyphosate and identical results were obtained by using the analytical curve and the standard addition method. The comparison with a voltammetric method with Hg electrode, after a reaction with nitrite, showed quite concordant results for the analysis of the surface water sample. Therefore, the proposed method can be applied to direct determinations of the herbicide in waters, decreasing the time of analysis; besides, the method is in agreement with the "green chemistry" concept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study a new approach, solid phase micro extraction (SPME), is used in the evaluation of the infinite dilution activity coefficient of the solute in a given solvent. It is the purpose of the current work to demonstrate a different approach to obtain the data needed for studying the solution thermodynamics of binary liquid mixtures as well as for designing multi-component separations. The solutes investigated at the temperature 298.15 K were toluene, ethyl benzene and xylene in the solvent methanol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical applications of a CPE modified with chitosan for the determination of Cu(II) in wastewater samples using anodic stripping voltammetry are described. The best voltammetric response was observed for a paste containing 25% m/m of chitosan. A 0.10 mol L-1 NaNO3 solution (pH 6.5) as supporting electrolyte, a pre-concentration potential of -0.20 V, pre-concentration time of 270 s and a scan rate of 25 mV s-1 were selected. The calibration graph was linear in the Cu(II) concentration range from 2.0 x 10-7 to 7.4 x 10-6 mol L-1, with a detection limit of 8.3 x 10-8 mol L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This experiment, where very common materials and equipments are used, conducts to good and interesting results related to the ionic radii of sodium and chloride ions. It also offers an excellent opportunity to discuss the crystalline arrangement of solids and to apply simple mathematical tools for calculations. Other important concepts such as density, solubility and saturated solution are also used. The simplicity of the experiment creates an excellent opportunity for reasoning with the students about the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an alternate method to detect forbidden doping substances present in biological matrices of horseracing. The method was fully validated for caffeine, identified as the most frequent forbidden substance in the analysis conducted by the Antidoping Laboratory of the Brazilian Jockey Club, which adopts a zero threshold limit according to national and international horseracing practices. The metrological reliability of the method applied to toxicological analysis in biological matrices is discussed. Although the analytical method proposed for detection of a zero threshold level of the doping substance is qualitative, it was validated for the determination of the limiting value (also known as quantification limit value) introducing a criterion that prevents the issuing of incorrect results ("false-positives" and "false-negatives").

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development of electroanalytical methodologies for the determination of atrazine, ametrine and simazine by square wave voltammetry on a mercury electrode. For pure atrazine and pure ametrine, the detection limits (DL) were 3.7 and 4.3 µg L-1, respectively, while they increased to 4.8 and 6.5 µg L-1 in the presence of 3.0 x 10-6 mol L-1 of the other component (a mathematical deconvolution program was used in the mixture cases). The voltammetric response for simazine could not be separated from that of atrazine and measurements were carried out only in pure simazine solutions (DL: 7.5 µg L-1).