971 resultados para ANALYTICAL-CHEMISTRY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Drug-protein binding is an important process in determining the activity and fate of a pharmaceutical agent once it has entered the body. This review examines the method of microdialysis combined with high-performance liquid chromatography (HPLC) that has been developed;by ours to study such interactions, in which the microdialysis was applied to sample the free drug in the mixed solution of drug with protein, and HPLC to quantify the concentration of free drug in the microdialysate. This technique has successfully been used for determining various types of binding interactions between the low affinity drugs, high affinity drugs and enantiomers to HSA. For the case of competitive binding of two drugs to a protein in solution, a displacement equation has been derived and examined with four nonsteroidal anti-inflammatory drugs and HSA as model drugs and protein, respectively. Microdialysis with HPLC was adopted to determine simultaneously the free solute and displacing agent in drug-protein solutions. The method is able to locate the binding site and determine affinity constants even up to 10(7) L/mol accurately.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new nonadentate ligand, N, N, N-1, N-1-[2,6-bis(3'-aminomethyl-1 1'-pyrazolyl)-4-phenylpyridine]tetrakis(acetic acid) (BPTA) for a Tb3+ fluorescent complex was synthesized. The Tb3+ complex is strongly fluorescent, having a large fluorescence quantum yield of 1.00 and very long fluorescence lifetime of 2.681 ms in 0.05 M berate buffer of pH 9.1. Streptavidin (SA) was labeled with SPTA by using its succinimidyl monoester, and the BPTA-Tb3+-labeled SA was used in sandwich-type time-resolved fluoroimmunoassay (TR-FIA) of alpha -fetoprotein (AFP) and carcinoembryonic antigen (CEA) in human sera. The Tb3+-labeled SA was also used in competitive type TR-FIA of bensulfuron- methyl (BSM) in water. The detection limits of these assays are 42 pg/mL for AFP, 70 pg/mL for CEA, and 0.4 ng/mL for BSM. In addition, a new simultaneous measurement method for AFP and CEA in a human serum sample was developed by using 4,4'-bis(1 " ,1 " ,1 " ,2 " ,2 " ,3 " ,3 " -heptafluoro-4 " ,6 " -hexanedion-6 " -yl)chlorosulfo-o-terphenyl ((BHHCT)-Eu3+-labeled anti-AFP antibody, biotinylated anti-CEA antibody, and BPTA-Tb3+-labeled SA. The concentrations of AFP and CEA in 39 human serum samples were determined, and the results were compared with those of the independently determined AFP and CEA by TR-FIA with a single-label method. A good correlation was obtained with the correlation coefficients of 0.991 for AFP and 0.994 for CEA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Described here is a mass spectrometry-based screening assay for the detection of protein-ligand binding interactions in multicomponent protein mixtures. The assay utilizes an oxidation labeling protocol that involves using hydrogen peroxide to selectively oxidize methionine residues in proteins in order to probe the solvent accessibility of these residues as a function of temperature. The extent to which methionine residues in a protein are oxidized after specified reaction times at a range of temperatures is determined in a MALDI analysis of the intact proteins and/or an LC-MS analysis of tryptic peptide fragments generated after the oxidation reaction is quenched. Ultimately, the mass spectral data is used to construct thermal denaturation curves for the detected proteins. In this proof-of-principle work, the protocol is applied to a four-protein model mixture comprised of ubiquitin, ribonuclease A (RNaseA), cyclophilin A (CypA), and bovine carbonic anhydrase II (BCAII). The new protocol's ability to detect protein-ligand binding interactions by comparing thermal denaturation data obtained in the absence and in the presence of ligand is demonstrated using cyclosporin A (CsA) as a test ligand. The known binding interaction between CsA and CypA was detected using both the MALDI- and LC-MS-based readouts described here.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Surgery is one of the most effective and widely used procedures in treating human cancers, but a major problem is that the surgeon often fails to remove the entire tumor, leaving behind tumor-positive margins, metastatic lymph nodes, and/or satellite tumor nodules. Here we report the use of a hand-held spectroscopic pen device (termed SpectroPen) and near-infrared contrast agents for intraoperative detection of malignant tumors, based on wavelength-resolved measurements of fluorescence and surface-enhanced Raman scattering (SERS) signals. The SpectroPen utilizes a near-infrared diode laser (emitting at 785 nm) coupled to a compact head unit for light excitation and collection. This pen-shaped device effectively removes silica Raman peaks from the fiber optics and attenuates the reflected excitation light, allowing sensitive analysis of both fluorescence and Raman signals. Its overall performance has been evaluated by using a fluorescent contrast agent (indocyanine green, or ICG) as well as a surface-enhanced Raman scattering (SERS) contrast agent (pegylated colloidal gold). Under in vitro conditions, the detection limits are approximately 2-5 × 10(-11) M for the indocyanine dye and 0.5-1 × 10(-13) M for the SERS contrast agent. Ex vivo tissue penetration data show attenuated but resolvable fluorescence and Raman signals when the contrast agents are buried 5-10 mm deep in fresh animal tissues. In vivo studies using mice bearing bioluminescent 4T1 breast tumors further demonstrate that the tumor borders can be precisely detected preoperatively and intraoperatively, and that the contrast signals are strongly correlated with tumor bioluminescence. After surgery, the SpectroPen device permits further evaluation of both positive and negative tumor margins around the surgical cavity, raising new possibilities for real-time tumor detection and image-guided surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Herein, we demonstrate that highly sensitive conductometric gas nanosensors for H(2)S can be synthesized by electrodepositing gold nanoparticles on single-walled carbon nanotube (SWNT) networks. Adjusting the electrodeposition conditions allowed for tuning of the size and number of gold nanoparticles deposited. The best H(2)S sensing performance was obtained with discrete gold nanodeposits rather than continuous nanowires. The gas nanosensors could sense H(2)S in air at room temperature with a 3 ppb limit of detection. The sensors were reversible, and increasing the bias voltage reduced the sensor recovery time, probably by local Joule heating. The sensing mechanism is believed to be based on the modulation of the conduction path across the nanotubes emanating from the modulation of electron exchange between the gold and carbon nanotube defect sites when exposed to H(2)S.