925 resultados para tensionless vaginal tape
Resumo:
Background: Elective repeat caesarean delivery (ERCD) rates have been increasing worldwide, thus prompting obstetric discourse on the risks and benefits for the mother and infant. Yet, these increasing rates also have major economic implications for the health care system. Given the dearth of information on the cost-effectiveness related to mode of delivery, the aim of this paper was to perform an economic evaluation on the costs and short-term maternal health consequences associated with a trial of labour after one previous caesarean delivery compared with ERCD for low risk women in Ireland.Methods: Using a decision analytic model, a cost-effectiveness analysis (CEA) was performed where the measure of health gain was quality-adjusted life years (QALYs) over a six-week time horizon. A review of international literature was conducted to derive representative estimates of adverse maternal health outcomes following a trial of labour after caesarean (TOLAC) and ERCD. Delivery/procedure costs derived from primary data collection and combined both "bottom-up" and "top-down" costing estimations.Results: Maternal morbidities emerged in twice as many cases in the TOLAC group than the ERCD group. However, a TOLAC was found to be the most-effective method of delivery because it was substantially less expensive than ERCD ((sic)1,835.06 versus (sic)4,039.87 per women, respectively), and QALYs were modestly higher (0.84 versus 0.70). Our findings were supported by probabilistic sensitivity analysis.Conclusions: Clinicians need to be well informed of the benefits and risks of TOLAC among low risk women. Ideally, clinician-patient discourse would address differences in length of hospital stay and postpartum recovery time. While it is premature advocate a policy of TOLAC across maternity units, the results of the study prompt further analysis and repeat iterations, encouraging future studies to synthesis previous research and new and relevant evidence under a single comprehensive decision model.
Resumo:
Background: The first childbirth has the greatest impact on a woman’s pelvic floor when major changes occur. The aim of this study was to comprehensively describe pelvic floor dysfunction (PFD) in young nulliparous women, and its correlation with postnatal pathology. Methods: A prospective study was performed at Cork University Maternity Hospital, Ireland. Initially 1484 nulliparous women completed the validated Australian Pelvic Floor Questionnaire at 15 weeks’ gestation and repeatedly at one year postnatally (N=872). In the second phase, at least one year postnatally, 202 participants without subsequent pregnancies attended the clinical follow up which included: pelvic organ prolapse quantification, a 3D-Transperineal ultrasound scan and collagen level assessment. Results: A high pre-pregnancy prevalence of various types of PFD was detected, which in the majority of cases persisted postnatally and included multiple types of PFD. The first birth had a negative impact on severity of pre-pregnancy symptoms in <15% of cases. Apart from prolapse, vaginal delivery, including instrumental delivery did not increase the risk of PFD symptoms, where as Caesarean section was protective for all types of PFD. The first birth had a bigger impact on pre-existing symptoms of overactive bladder compared to stress urinary incontinence. Pelvic organ prolapse is extremely prevalent in young primiparous women, however usually it is low grade and asymptomatic. Congenital factors and high collagen type III levels play an important role in the aetiology of pelvic organs prolapse. Levator ani trauma is present in one in three women after the first pregnancy and delivery. Conclusion: The main damage to the pelvic floor most likely occurs due to an undiagnosed congenital intrinsic weakness of the pelvic floor structures. PFD is highly associated with first childbirth, however it seems that pregnancy and delivery are contributing factors only which unmask the congenital intrinsic weakness of the pelvic floor support.
Resumo:
This thesis work covered the fabrication and characterisation of impedance sensors for biological applications aiming in particular to the cytotoxicity monitoring of cultured cells exposed to different kind of chemical compounds and drugs and to the identification of different types of biological tissue (fat, muscles, nerves) using a sensor fabricated on the tip of a commercially available needle during peripheral nerve block procedures. Gold impedance electrodes have been successfully fabricated for impedance measurement on cells cultured on the electrode surface which was modified with the fabrication of gold nanopillars. These nanostructures have a height of 60nm or 100nm and they have highly ordered layout as they are fabricated through the e-beam technique. The fabrication of the threedimensional structures on the interdigitated electrodes was supposed to improve the sensitivity of the ECIS (electric cell-substrate impedance sensing) measurement while monitoring the cytotoxicity effects of two different drugs (Antrodia Camphorata extract and Nicotine) on three different cell lines (HeLa, A549 and BALBc 3T3) cultured on the impedance devices and change the morphology of the cells growing on the nanostructured electrodes. The fabrication of the nanostructures was achieved combining techniques like UV lithography, metal lift-off, evaporation and e-beam lithography techniques. The electrodes were packaged using a pressure sensitive, medical grade adhesive double-sided tape. The electrodes were then characterised with the aid of AFM and SEM imaging which confirmed the success of the fabrication processes showing the nanopillars fabricated with the right layout and dimensions figures. The introduction of nanopillars on the impedance electrodes, however, did not improve much the sensitivity of the assay with the exception of tests carried out with Nicotine. HeLa and A549 cells appeared to grow in a different way on the two surfaces, while no differences where noticed on the BALBc 3T3 cells. Impedance measurements obtained with the dead cells on the negative control electrodes or the test electrodes with the drugs can be compared to those done on the electrodes containing just media in the tested volume (as no cells are attached and cover the electrode surface). The impedance figures recorded using these electrodes were between 1.5kΩ and 2.5 kΩ, while the figures recorded on confluent cell layers range between 4kΩ and 5.5kΩ with peaks of almost 7 kΩ if there was more than one layer of cells growing on each other. There was then a very clear separation between the values of living cell compared to the dead ones which was almost 2.5 - 3kΩ. In this way it was very easy to determine whether the drugs affected the cells normal life cycle on not. However, little or no differences were noticed in the impedance analysis carried out on the two different kinds of electrodes using cultured cells. An increase of sensitivity was noticed only in a couple of experiments carried out on A549 cells growing on the nanostructured electrodes and exposed to different concentration of a solution containing Nicotine. More experiments to achieve a higher number of statistical evidences will be needed to prove these findings with an absolute confidence. The smart needle project aimed to reduce the limitations of the Electrical Nerve Stimulation (ENS) and the Ultra Sound Guided peripheral nerve block techniques giving the clinicians an additional tool for performing correctly the peripheral nerve block. Bioimpedance, as measured at the needle tip, provides additional information on needle tip location, thereby facilitating detection of intraneural needle placement. Using the needle as a precision instrument and guidance tool may provide additional information as to needle tip location and enhance safety in regional anaesthesia. In the time analysis, with the frequency fixed at 10kHz and the samples kept at 12°C, the approximate range for muscle bioimpedance was 203 – 616 Ω, the approximate bioimpedance range for fat was 5.02 - 17.8 kΩ and the approximate range for connective tissue was 790 Ω – 1.55 kΩ. While when the samples were heated at 37°C and measured again at 10kHz, the approximate bioimpedance range for muscle was 100-175Ω. The approximate bioimpedance range of fat was 627 Ω - 3.2 kΩ and the range for connective tissue was 221-540Ω. In the experiments done on the fresh slaughtered lamb carcass, replicating a scenario close to the real application, the impedance values recorded for fat were around 17 kΩ, for muscle and lean tissue around 1.3 kΩ while the nervous structures had an impedance value of 2.9 kΩ. With the data collected during this research, it was possible to conclude that measurements of bioimpedance at the needle tip location can give valuable information to the clinicians performing a peripheral nerve block procedure as the separation (in terms of impedance figures) was very marked between the different type of tissues. It is then feasible to use an impedance electrode fabricated on the needle tip to differentiate several tissues from the nerve tissue. Currently, several different methods are being studied to fabricate an impedance electrode on the surface of a commercially available needle used for the peripheral nerve block procedure.
Resumo:
BACKGROUND: Shared decision-making has become the standard of care for most medical treatments. However, little is known about physician communication practices in the decision making for unstable critically ill patients with known end-stage disease. OBJECTIVE: To describe communication practices of physicians making treatment decisions for unstable critically ill patients with end-stage cancer, using the framework of shared decision-making. DESIGN: Analysis of audiotaped encounters between physicians and a standardized patient, in a high-fidelity simulation scenario, to identify best practice communication behaviors. The simulation depicted a 78-year-old man with metastatic gastric cancer, life-threatening hypoxia, and stable preferences to avoid intensive care unit (ICU) admission and intubation. Blinded coders assessed the encounters for verbal communication behaviors associated with handling emotions and discussion of end-of-life goals. We calculated a score for skill at handling emotions (0-6) and at discussing end of life goals (0-16). SUBJECTS: Twenty-seven hospital-based physicians. RESULTS: Independent variables included physician demographics and communication behaviors. We used treatment decisions (ICU admission and initiation of palliation) as a proxy for accurate identification of patient preferences. Eight physicians admitted the patient to the ICU, and 16 initiated palliation. Physicians varied, but on average demonstrated low skill at handling emotions (mean, 0.7) and moderate skill at discussing end-of-life goals (mean, 7.4). We found that skill at discussing end-of-life goals was associated with initiation of palliation (p = 0.04). CONCLUSIONS: It is possible to analyze the decision making of physicians managing unstable critically ill patients with end-stage cancer using the framework of shared decision-making.
Resumo:
Microbicides are women-controlled prophylactics for sexually transmitted infections. The most important class of microbicides target HIV-1 and contain antiviral agents formulated for topical vaginal delivery. Identification of new viral entry inhibitors that target the HIV-1 envelope is important because they can inactivate HIV-1 in the vaginal lumen before virions can come in contact with CD4+ cells in the vaginal mucosa. Carbohydrate binding agents (CBAs) demonstrate the ability to act as entry inhibitors due to their ability to bind to glycans and prevent gp120 binding to CD4+ cells. However, as proteins they present significant challenges in regard to economical production and formulation for resource-poor environments. We have synthesized water-soluble polymer CBAs that contain multiple benzoboroxole moieties. A benzoboroxole-functionalized monomer was synthesized and incorporated into linear oligomers with 2-hydroxypropylmethacrylamide (HPMAm) at different feed ratios using free radical polymerization. The benzoboroxole small molecule analogue demonstrated weak affinity for HIV-1BaL gp120 by SPR; however, the 25 mol % functionalized benzoboroxole oligomer demonstrated a 10-fold decrease in the K(D) for gp120, suggesting an increased avidity for the multivalent polymer construct. High molecular weight polymers functionalized with 25, 50, and 75 mol % benzoboroxole were synthesized and tested for their ability to neutralize HIV-1 entry for two HIV-1 clades and both R5 and X4 coreceptor tropism. All three polymers demonstrated activity against all viral strains tested with EC(50)s that decrease from 15000 nM (1500 microg mL(-1)) for the 25 mol % functionalized polymers to 11 nM (1 microg mL(-1)) for the 75 mol % benzoboroxole-functionalized polymers. These polymers exhibited minimal cytotoxicity after 24 h exposure to a human vaginal cell line.
Resumo:
Quantitative optical spectroscopy has the potential to provide an effective low cost, and portable solution for cervical pre-cancer screening in resource-limited communities. However, clinical studies to validate the use of this technology in resource-limited settings require low power consumption and good quality control that is minimally influenced by the operator or variable environmental conditions in the field. The goal of this study was to evaluate the effects of two sources of potential error: calibration and pressure on the extraction of absorption and scattering properties of normal cervical tissues in a resource-limited setting in Leogane, Haiti. Our results show that self-calibrated measurements improved scattering measurements through real-time correction of system drift, in addition to minimizing the time required for post-calibration. Variations in pressure (tested without the potential confounding effects of calibration error) caused local changes in vasculature and scatterer density that significantly impacted the tissue absorption and scattering properties Future spectroscopic systems intended for clinical use, particularly where operator training is not viable and environmental conditions unpredictable, should incorporate a real-time self-calibration channel and collect diffuse reflectance spectra at a consistent pressure to maximize data integrity.
Resumo:
The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.
In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.
Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.
For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.
For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.
Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.
Resumo:
The authors present 2 cases of AIDS revealed by severe recurrent genital herpes simplex. The patients are 2 young, previously healthy, African women without histories of homosexuality or drug abuse. The first patient died after 5 months of follow-up (post mortem findings: viral bronchopneumonia with positive cultures for herpes and cytomegalovirus (CMV), viral colitis due to CMV). The second patient survived. She has been treated, during the last 11 months, for filariasis, buccal and vaginal candidiasis and cerebral toxoplasmosis.
Resumo:
The article focuses on an information system to exploit the use of metadata within film and television production. It is noted that the television and film industries are used to working on big projects. This involves the use of actual film, video tape, and P.E.R.T charts for project planning. Scripts are in most instances revised. It is essential to attach information on these in order to manage, track and retrieve them. The use of metadata eases the operations involved in these industries.
Resumo:
Una de las cuencas hidrográficas más importante de la Península es la del río Tajo, por su extensión y por su caudal. Se trata de una fosa tectónica calificable de modélica. Dos moles montañosas, el Sistema central y los Montes de Toledo en sentido amplio, la flanquean al Norte y al Sur. La dovela hundida, formada por idénticos materiales que las Sierras, granitos y gneis, alcanza una gran profundidad. Al Este el Sistema Ibérico castellano, principalmente calizo y mesozoico, cierra Castilla y la cuenca, viniendo a dar vida con el agua de sus nieves a un Tajo niño’. El inicio de su Historia Geológica podemos situarlo en el Paleozoico, tiempo geológico durante el cual los territorios donde hoy se sitúa la Meseta estaban formando grandes cordilleras producto de la Orogenia Herciniana. La última etapa de la formación de los relieves actuales de la cuenca la encontramos en la reactivación de los antiguos macizos arrasados. Se inicia con los materiales de la raña y sus equivalentes en el centro de la Cuenca o Fosa del Tajo, y se caracteriza por una progresiva individualización de los procesos, pasándose de las grandes superficies generalizadas en macizos y cuencas, Sierras y Fosa del Tajo, a las pequeñas llanuras en franja u orla, que quedan localizadas en cada cuenca fluvial a medida que éstas se van consolidando por jerarquización, y partir de un río generatriz o emisario principal, el Tajo. La tectónica, procesos posteriores de captura, reajustes climáticos..., no permiten aún determinar cuál fue el orden de jerarquía en los ríos que hoy conocemos; no obstante, puede aventurarse que Jarama-Henares, Perales-Alberche y Guadarrama serían los primeros y Manzanares, Guadalix, Tajuña, los siguientes, y así sucesivamente. La síntesis de la realidad geológica, litológica y climática va a coadyuvar, frenando o favoreciendo, el desarrollo y la diferenciación entre los paisajes vegetales de las zonas montañosas y los de las depresiones terciarias y penillanuras paleozoicas, en un territorio marcado por el predominio del clima mediterráneo continentalizado, con matices de montaña y áreas de influencia atlántica.
Resumo:
Los agrietamientos poligonales representan una forma común de modelado granítico cuyo origen y evolución continúa en fase de estudio, no existiendo una sistematización de estas estructuras diversas. Algunos autores explican su origen por procesos geodinámicos internos, relacionándolo con movimientos de planos de fractura en estados tardíos de consolidación magmática. Otros autores atribuyen su formación y desarrollo a factores externos relacionados con el régimen climático. La gran variedad de agrietamientos poligonales requiere la utilización de un número mayor de variables para definir los distintos orígenes, y las posibles interrelaciones entre los factores externos e internos, así como para explicar la evolución de dichas estructuras y avanzar en la clasificación de los patrones concretos. Este trabajo pretende contribuir a sistematizar los mecanismos que intervienen en el desarrollo de agrietamientos poligonales. Para ello se estudian únicamente agrietamientos poligonales formados sobre planos de fractura verticales o subverticales. En particular se establecen relaciones entre la presencia de agrietamientos poligonales y la red de fracturación, la altura de aparición, la orientación e inclinación de la pared, la morfología de las placas y la profundidad de incisión de las grietas perimetrales. Por otra parte, establece relaciones entre procesos geodinámicos internos y procesos de meteorización externos.
Resumo:
En el presente trabajo se da el primer paso para la creación de una Filmoteca de Prácticas en la facultad de Ciencias de la Información de la Universidad Complutense de Madrid. El Patrimonio Fílmico se ve gravemente expuesto al paso del tiempo y el abandono por lo que se necesita un rescate urgente. Mediante un riguroso trabajo de investigación, en el que se estudian diferentes propuestas y normativas expuestas por organismos especializados, se redacta un manual de inicio. Se han investigado, diseñado y propuesto las herramientas básicas y útiles para poner en funcionamiento la primera Filmoteca de Prácticas en el ámbito universitario español.
Resumo:
The controlled-release characteristics of matrix silicone intravaginal rings loaded with between 100 and 971 mg of nonoxynol-9 have been investigated with a view to developing a ring that may offer a new female-controlled method for the prevention of transmission of sexually transmitted diseases, particularly HIV. Intravaginal rings containing 253, 487 and 971 mg of nonoxynol-9 provided a daily release of 2 mg or more over the 8-day release period, the minimal amount of nonoxynol-9 considered to provide an effective vaginal concentration for the prevention of HIV. Furthermore, the maximum daily release of N9 was about 6 mg, an amount significantly smaller than that observed for other nonoxynol-9 products whose large daily doses may in fact increase the occurrence of HIV by causing epithelial damage to the vaginal tissue. The release mechanism of the liquid nonoxynol-9 from the intravaginal rings has also been investigated and compared to models describing the release of solid drugs from the rings. It has been demonstrated through release studies and surface microscopy that a drug depletion zone is not established in such liquid-loaded intravaginal ring systems, with implications for the release kinetics. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The in vitro release characteristics of eight low-molecular-weight drugs (clindamycin, 17beta-estradiol, 17beta-estradiol-3-acetate, 17beta-estradiol diacetate, metronidazole, norethisterone, norethisterone acetate and oxybutynin) from silicone matrixtype intravaginal rings of various drug loadings have been evaluated under sink conditions. Through modelling of the release data using the Higuchi equation, and determination of the silicone solubility of the drugs, the apparent silicone elastomer diffusion coefficients of the drugs have been calculated. Furthermore, in an attempt to develop a quantitative model for predicting release rates of new drug substances from these vaginal ring devices, it has been observed that linear relationships exist between the log of the silicone solubility of the drug (mg ml(-1)) and the reciprocal of its melting point (K-1) (y = 3.558x - 9.620, R = 0.77), and also between the log of the diffusion coefficient (cm(2) s(-1)) and the molecular weight of the drug molecule (g mol(-1)) (y = - 0.0068x - 4.0738, R = 0.95). Given that the silicone solubility and silicone diffusion coefficient are the major parameters influencing the permeation of drugs through silicone elastomers, it is now possible to predict through use of the appropriate mathematical equations both matrix-type and reservoir-type intravaginal ring release rates simply from a knowledge of drug melting temperature and molecular weight. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
TMC 120 (Dapivirine) is a potent non-nucleoside reverse transcriptase inhibitor that is presently being developed as a vaginal HIV microbicide. To date, most vaginal microbicides under clinical investigation have been formulated as single-dose semi-solid gels, designed for application to the vagina before each act of intercourse. However, a clear rationale exists for providing long-term, controlled release of vaginal microbicides in order to afford continuous protection against heterosexually transmitted HIV infection and to improve user compliance. In this study we report on the incorporation of various pharmaceutical excipients into TMC 120 silicone, reservoir-type intravaginal rings (IVRs) in order to modify the controlled release characteristics of the microbicide. The results demonstrate that TMC 120 is released in zero-order fashion from the rings over a 28-day period and that release parameters could be modified by the inclusion of release-modifying excipients in the IVR. The hydrophobic liquid excipient isopropyl myristate had little effect on steady-state daily release rates, but did increase the magnitude and duration of burst release in proportion to excipient loading in the IVR. By comparison, the hydrophobic liquid poly(dimethylsiloxane) had little effect on TMC 120 release parameters. A hydrophilic excipient, lactose, had the surprising effect of decreasing TMC 120 burst release while increasing the apparent steady-state daily release in a concentration-dependent manner. Based on previous cell culture data and vaginal physiology, TMC120 is released from the various ring formulations in amounts potentially capable of maintaining a protective vaginal concentration. It is further predicted that the observed release rates may be maintained for at least a period of 1 year from a single ring device. TMC 120 release profiles and the mechanical properties of rings could be modified by the physicochemical nature of hydrophobic and hydrophilic excipients incorporated into the IVRs.