987 resultados para organic electronics semiconductors detectors sensors X-rays
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Technological advances achieved during the twentieth century strongly boosted the scientific research in the area of condensed matter physics, especially in the study and development of new semiconductor materials. In the segment, the development of semiconducting polymers for application in electronic devices promotes the field of organic electronics...(Complete abstract click electronic access below)
Resumo:
During the twentieth century the inorganic electronics was largely developed being present in various industrial equipment or household use. However, at the end of that century were verified electronic properties in organic compounds, giving rise to the field of organic electronics. Since then, the physical properties of elementary devices such as diodes and organic transistors have been studied. In this work was studied the properties of diode devices fabricated with a semiconductor polymer, the poly-o-methoxyaniline (POMA). Devices containing electrodes of Au and Al were fabricated with semiconductor polymer of different doping levels. We found that the rectifying behavior for the heterojunctions metal/polimer are reached only for high doping level (with conductivity greater than 1,77. 10-9 S / cm), which gives the devices characteristic of a Schottky diode. The rectifying behavior was observed for electric fields of low magnitude, below the operating field (~ 600 V/cm), while for electric field greater than 600 V/cm the a linear behavior I vs.V was obtained. We determined that this Ohmic behavior arises from the charge transport over the volume of the semiconductor material after the lowering of the metal/semiconductor barrier. In devices with weakly doped semiconductor, the electrical resistance of the volume becomes high and the process of charge transportation is dominated by the volume, for any intensity of the applied electric field
Resumo:
The Therapy with proton beam has shown more e ective than Radiotherapy for oncology treatment. However, to its planning use photon beam Computing Tomography that not considers the fundamentals di erences the interaction with the matter between X-rays and Protons. Nowadays, there is a great e ort to develop Tomography with proton beam. In this way it is necessary to know the most likely trajectory of proton beam to image reconstruction. In this work was realized calculus of the most likely trajectory of proton beam in homogeneous target compound with water that was considered the inelastic nuclear interaction. Other calculus was the analytical calculation of lateral de ection of proton beam. In the calculation were utilized programs that use Monte Carlo Method: SRIM 2006 (Stopping and Range of Ions in Matter ), MCNPX (Monte Carlo N-Particle eXtended) v2.50. And to analytical calculation was employed the software Wolfram Mathematica v7.0. We obtained how di erent nuclear reaction models modify the trajectory of proton beam and the comparative between analytical and Monte Carlo method
Resumo:
Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care
Resumo:
The objective of the present work was to evaluate surface of experimental alloy Ti-7.5Mo after hydrothermal treatment. Ingots were obtained in arc melting furnace under an argon atmosphere and then homogenized under vacuum at 1100ºC for 86.4 ks to eliminate chemical segregation and after cold worked discs were cutting and grinding. For surface treatment, samples were immersed in a container with NaOH aqueous solution 5M, autoclaved, washed with distilled water. Followed, samples were heat treated and they were soaking in 5xSBF to form an apatite layer on the surface. Surfaces were investigated by, scanning electron microscopy, X-Rays powder diffraction, atomic force microscopy and contact angle, in order to evaluate the wettability of the alloy surface. The results were compared with our previous studies using the group of chemical surface treatments and results shows better condition is 120 minutes in the autoclave
Resumo:
Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care
Resumo:
This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology
Resumo:
Pós-graduação em Odontologia Restauradora - ICT