568 resultados para Traction-Gripper
Resumo:
Trabajo realizado en la empresa ULMA Embedded Solutions
Resumo:
The low tenacity presented by the Portland cement pastes used in the oil wells cementation has been motivating several researches with attention focused on alternative materials. Additives have been developed to generate flexible pastes with mechanical resistance capable to support the expansions and retractions of the metallic covering of the wells that submit to the steam injection, technique very used to increase the recovery factor in oil reservoirs with high viscosity. A fresh paste with inadequate rheological behavior may commit the cementation process seriously, involving flaws that affect the performance of the paste substantially in the hardened state. This work proposes the elaboration and the rheological analysis of Portland cement pastes with addition of residues of rubber tire in several proportions, with the aim of minimizing the damages provoked in the hem cementing of these wells. By thermogravimetric analysis, the particles of eraser that go by the sieve of 0,5mm (35 mesh) opening and treated superficially with NaOH solution of 1 mol/L presented appropriate thermal resistance for wells that submit to thermal cyclic. The evaluation of the study based on the results of the rheological analysis of the pastes, complemented by the mechanical analysis, thickening, stability, tenor of free water and filtrate loss, being used as parameter a paste reference, without rubber addition. The results showed satisfactory rheology, passive of few corrections; considerable loss of mechanical resistance (traction and compression), compensated by earnings of tenacity, however with established limits for its application in oil wells; satisfactory stability, free water and thickening time
Resumo:
El reacondicionamiento de los brackets es una alternativa que trae consigo beneficios a la práctica ortodóncica. Por tal motivo el propósito de este estudio fue determinar la resistencia a la fuerza de tracción, de los métodos de reacondicionamiento, para ello se utilizó el Tensómetro Universal de fuerzas Z005 serie 157864 ( Zwick/Roell; BE, Alemania); con el mismo que se realizó el estudio in vitro y se obtuvo resultados que mostraron cual presentó mayor resistencia. La investigación se realizó con un total de 90 muestras, las mismas que se las dividieron en 3 grupos de 30 respectivamente. Los resultados de la prueba de tracción fueron los siguientes: grupo 1 (brackets nuevos) fue el grupo que tuvo mayor resistencia a la fuerza de tracción con una media de 11,32 MPa con una desviación estándar mínima de 10,51MPa y máxima de 12,26MPa, grupo 2 (brackets arenados) tuvo una resistencia a la fuerza de tracción de 8,36 MPa con una desviación estándar mínima de 7,20MPa y máxima de 9,49MPa y el grupo 3 (brackets flameados) tuvo una resistencia menor a la fuerza de tracción de 4,73MPa y una desviación estándar mínima de 3,37MPa y máxima de 5,84MPa. La resistencia a la fuerza de tracción de brackets nuevos y reacondicionados, mostró datos diferentes en cada grupos, los mismos que fueron estadísticamente significativos, teniendo un valor de p ≤ 0,05 y registró que el grupo de brackets arenados es el más resistente a la fuerza de tracción, referente a los dos métodos de reacondicionamiento; pero ninguno de los métodos de reacondicionamiento investigados se asemeja o supera a los valores que reporta los brackets nuevos.
Resumo:
Although already to exist alternative technique and economically viable for destination of used tires, quantitative data on properties of constructive elements that use the rubber waste as aggregate still are restricted. In the present work, the waste proceeding from industry of retreading as material for manufacture of composite destined to the production of constructive elements was considered. Mechanical and thermal properties of mortar had been analyzed Portland cement with addition of waste without treatment, in the ratios of 10%, 20% and 30% in mass in relation to the mass of the cement, substituting the aggregate in the trace in mortar 1:5 mass cement and sand. The size of the used residue varied between 0,30mm and 4,8mm (passing in the bolter 4,8mm and being restrained in the one of 0,30mm), being it in the formats fibers and granular. The influences of the size and the percentage of residue added to the mortar (in substitution to the aggregate) in the thermal and mechanical properties had been considered. Assays of body-of-test in thestates had been become fullfilled cool (consistency index) and hardened (absorption of water for capillarity, strength the compression, traction and strength flexural). The work is centralized in the problem of the relation thermal performance /strength mechanics of used constructive systems in regions of low latitudes (Been of the Piauí), characterized for raised indices of solar radiation.
Resumo:
This research is about the use of the coconut´s endocarp (nucifera linn) and the waste of derivatives of wood and furniture as raw material to technological use. In that sense, the lignocellulosic waste is used for manufacture of homogeneous wood sheet agglomerate (LHWS) and lignocellulosic load which take part of a polymeric composite with fiber glass E (GFRP-WC). In the manufacturing of the homogeneous wood sheet agglomerate (LHWS), it was used mamona´s resin as waste s agglutinating element. The plates were taken up in a hydraulic press engine, heated, with temperature control, where they were manufactured for different percentage of waste wood and coconuts nucífera linn. Physical tests were conducted to determine the absorption of water, density, damp grade (in two hours and twenty-four hours), swelling thickness (in two hours and twenty-four hours), and mechanical tests to evaluate the parallel tensile strength (internal stick) and bending and the static (steady) flexural. The physical test´s results indicate that the LHWS can be classified as bonded wood plate of high-density and with highly water resistant. In the mechanical tests it was possible to establish that LHWS presents different characteristics when submitted to uniaxial tensile and to the static (steady) flexural, since brittle and elasticity module had a variation according to the amount of dry endocarp used to manufacture each trace of LHWS. The GFRP-WC was industrially manufactured by a hand-lay-up process where the fiber glass E was used as reinforcement the lignocellulósic´s waste as load. The matrix was made with ortofitalic unsaturated polyester resin. Physical and mechanical tests were performed in presence of saturated humidity and dry. The results indicated good performance of the GFRP-WC, as traction as in flexion in three points. The presence of water influenced the modules obtained in the flexural and tensile but there were no significant alteration in the properties analyzed. As for the fracture, the analysis showed that the effects are more harmful in the presence of damp, under the action of loading tested, but despite this, the fracture was well defined starting in the external parts and spreading to the internal regions when one when it reaches the hybrid load
Resumo:
The concept of patient activation has gained traction as the term referring to patients who understand their role in the care process and have “the knowledge, skills and confidence” necessary to manage their illness over time (Hibbard & Mahoney, 2010). Improving health outcomes for vulnerable and underserved populations who bear a disproportionate burden of health disparities presents unique challenges for nurse practitioners who provide primary care in nurse-managed health centers. Evidence that activation improves patient self-management is prompting the search for theory-based self-management support interventions to activate patients for self-management, improve health outcomes, and sustain long-term gains. Yet, no previous studies investigated the relationship between Self-determination Theory (SDT; Deci & Ryan, 2000) and activation. The major purpose of this study, guided by the Triple Aim (Berwick, Nolan, & Whittington, 2008) and nested in the Chronic Care Model (Wagner et al., 2001), was to examine the degree to which two constructs– Autonomy Support and Autonomous Motivation– independently predicted Patient Activation, controlling for covariates. For this study, 130 nurse-managed health center patients completed an on-line 38-item survey onsite. The two independent measures were the 6-item Modified Health Care Climate Questionnaire (mHCCQ; Williams, McGregor, King, Nelson, & Glasgow, 2005; Cronbach’s alpha =0.89) and the 8-item adapted Treatment Self-Regulation Questionnaire (TSRQ; Williams, Freedman, & Deci, 1998; Cronbach’s alpha = 0.80). The Patient Activation Measure (PAM-13; Hibbard, Mahoney, Stock, & Tusler, 2005; Cronbach’s alpha = 0.89) was the dependent measure. Autonomy Support was the only significant predictor, explaining 19.1% of the variance in patient activation. Five of six autonomy support survey items regressed on activation were significant, illustrating autonomy supportive communication styles contributing to activation. These results suggest theory-based patient, provider, and system level interventions to enhance self-management in primary care and educational and professional development curricula. Future investigations should examine additional sources of autonomy support and different measurements of autonomous motivation to improve the predictive power of the model. Longitudinal analyses should be conducted to further understand the relationship between autonomy support and autonomous motivation with patient activation, based on the premise that patient activation will sustain behavior change.
Resumo:
The study aimed at the treatment of attapulgite for the development and characterization of composite recycled low density polyethylene - PEBD_rec embedded with natural attapulgite - ATP_NAT, sifted - ATP_PN and attapulgite treated with sulfuric acid - ATP_TR in different compositions (1, 3 and 5%) and compared with the PEBD_rec. The atapulgitas, natural, screened and treated, were characterized by X-ray diffraction (XRD), X-ray fluorescence (XRF), particle size analysis, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and determining the area specific surface (BET). The composites were characterized by thermogravimetry (TG), differential scanning calorimetry (DSC), Xray diffraction (XRD), torque rheometry, scanning electron microscopy (SEM) and traction. The composite PEBD_rec / ATP (natural, sieved and treated) were produced by mixing in the molten state in a single screw extruder matrix wire with subsequent reprocessing matrix tape. It was found that the screening of attapulgite not reduce the quantity of quartz and the acid treatment completely extracted dolomite aggregate impurities of the channels attapulgite, and increase their surface area. The addition of attapulgite in PEBD_rec acts as a catalyst, reducing the thermal stability of the polymer. The increased concentration of attapulgite, increases resistance and reduces the elongation at break and modulus of elasticity of the composite PEBD_rec / attapulgite
Resumo:
Tactile sensing is an important aspect of robotic systems, and enables safe, dexterous robot-environment interaction. The design and implementation of tactile sensors on robots has been a topic of research over the past 30 years, and current challenges include mechanically flexible “sensing skins”, high dynamic range (DR) sensing (i.e.: high force range and fine force resolution), multi-axis sensing, and integration between the sensors and robot. This dissertation focuses on addressing some of these challenges through a novel manufacturing process that incorporates conductive and dielectric elastomers in a reusable, multilength-scale mold, and new sensor designs for multi-axis sensing that improve force range without sacrificing resolution. A single taxel was integrated into a 1 degree of freedom robotic gripper for closed-loop slip detection. Manufacturing involved casting a composite silicone rubber, polydimethylsiloxane (PDMS) filled with conductive particles such as carbon nanotubes, into a mold to produce microscale flexible features on the order of 10s of microns. Molds were produced via microfabrication of silicon wafers, but were limited in sensing area and were costly. An improved technique was developed that produced molds of acrylic using a computer numerical controlled (CNC) milling machine. This maintained the ability to produce microscale features, and increased the sensing area while reducing costs. New sensing skins had features as small as 20 microns over an area as large as a human hand. Sensor architectures capable of sensing both shear and normal force sensing with high dynamic range were produced. Using this architecture, two sensing modalities were developed: a capacitive approach and a contact resistive approach. The capacitive approach demonstrated better dynamic range, while the contact resistive approach used simpler circuitry. Using the contact resistive approach, normal force range and resolution were 8,000 mN and 1,000 mN, respectively, and shear force range and resolution were 450 mN and 100 mN, respectively. Using the capacitive approach, normal force range and resolution were 10,000 mN and 100 mN, respectively, and shear force range and resolution were 1,500 mN and 50 mN, respectively.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2012.
Resumo:
The coatings mortars are essential elements of building structures because they execute an important role in protecting walls and are particularly exposed to aggressive action responsible for its degradation over time. The importance of wall coverings has been the subject of discussion and analysis in the conservation and rehabilitation of old buildings. Are sometimes removed and replaced with inappropriate solutions of constructive point of view or architecture. The most commonly used coatings on walls of old buildings is based on traditional hydraulic lime mortars. The present study aims at the formulation of new lime- based mortars and aerial fine aggregate, in order to contribute to a better field of conservation and restoration mortar coating of old buildings. Residue was used for polishing porcelain as fine aggregate, replacing the aggregate (sand), in percentages 05-30% by mass. We conducted a thorough evaluation of the mortar properties in fresh and hardened state by comparing the performance of the same with a reference mortar. The residue used was characterized as the density, bulk density, and particle size laser, scanning electron microscopy, X-ray diffraction and X-ray fluorescence. Formulations were produced 7, 6 with residue and one commonly used formulation, which served as a reference. In the formulations of lime mortars air (hydrated lime powder CH-I) has been adopted a stroke volume (1:3) with constant binder, was varied and the water / binder and aggregate and waste. For evaluation of mortars fresh, proceeded to consistency analysis, specific gravity, water retention and air content embedded. In the hardened state assays were performed in specific gravity, water retention, modulus of elasticity, tensile strength in bending, compressive strength, water absorption by capillary action, adhesion, tensile strength, resistance to shrinkage and salts by of crystallization trials with resources chloride solution, nitrate and sulfate all sodium in prismatic at 90 days of age, in addition to the micro structural analysis of mortars. Based on the results we can see that the mortar formulated with 10% content of waste and the reference free retraction feature more stable closer to neutrality. The composition of 10% was obtained better performance against the action of the salt crystallization. The mortar with 15% residue obtained better density, lower air content embedded and high capacity for water retention developing good workability. The replacement of 20% of waste generates a satisfactory utilization of resistance to compression, flexion and traction grip the base. And, finally, it can be seen that the mortar with 10, 15 and 20% residual show, in principle, good suitability as coatings, thus enabling a final result consistent with durability, workability and aesthetics developing therefore a material with better performance to repair or replace existing mortars in old buildings
Resumo:
O presente relatório, intitulado “O Programa Idosos em Segurança: Estudo de Caso do Dter de Sintra”, baseia-se num estudo da análise do trabalho que é desenvolvido pelos militares do Destacamento Territorial de Sintra e tem a finalidade de avaliar o impacto e influência do Programa Idosos em Segurança na população adstrita a este Destacamento. O envelhecimento é uma realidade inevitável e que deve, cada vez mais ser preparada e antecipada, permitindo, a quem pretender participar na vida ativa da sua comunidade, que tal seja possível. Para aqueles que, não têm possibilidades de o fazer, deve garantir-se assegurada, em todas as situações a sua dignidade enquanto pessoa humana. O envelhecimento ativo é também uma temática abordada que carece de tratamento pela sua novidade e extrema relevância no contexto atual. Para que tais realidades sejam coincidentes é imperioso que o policiamento de proximidade se efetue e que se abram portas ao desenvolvimento das capacidades de resposta dos diferentes órgãos de apoio social e das Forças de Segurança. Para conseguirmos responder à Questão de Partida, formulámos quatro Questões Derivadas e consequentes Hipóteses que, através da sua verificação, validação ou refutação, nos permitiram responder às questões anteriormente levantadas. Foram realizadas Entrevistas e Questionários, que nos permitiram aceder às diferentes perspetivas que trabalham e são alvo deste Programa. A Guarda Nacional Republicana possui um grande reconhecimento junto das entidades externas e dos idosos com quem trabalha. Foram, no entanto, encontradas algumas falhas ao nível do efetivo, da formação, especialização e verificação do trabalho desenvolvido, a vários níveis. De salientar que muitas falhas são colmatadas pela boa capacidade de adaptação dos militares, o que evita que tais fragilidades afetem o serviço prestado e transpareçam para o exterior.
Resumo:
Realizaram-se testes físico-mecânicos e físico-químicos em couro de tilápia vermelha (Oreochromis spp.) a fim de testar a sua resistência. As amostras foram distribuídas em delineamento inteiramente ao acaso com dois tratamentos: no T1, procedeu-se à retirada do corpo-de-prova no sentido longitudinal e, no T2, à retirada do corpo-de-prova no sentido transversal. Para os testes de determinação da resistência à tração, alongamento e rasgamento progressivo, foi utilizado o dinamômetro EMIC, com velocidade de afastamento entre as cargas de 100 ± 20mm/min, em ambiente climatizado (± 23ºC e UR do ar de 50%), por 24 horas. A espessura do couro variou de 0,61 a 0,75mm, mas não houve diferença entre os sentidos analisados. O couro apresentou maior resistência à tração no sentido transversal, 25,89N/mm², (P<0,01), comparado ao sentido longitudinal, 14,20 N/mm². O alongamento foi significativamente (P<0,05) maior no sentido longitudinal, 80,8%, em relação ao transversal, 62,6%. Não houve diferença para o rasgamento progressivo entre os tratamentos. O couro apresentou teor de óxido de cromo de 3,8%, graxa de 15,1% e pH e cifra diferencial de 3,5 e 0,5, respectivamente. Os valores nos testes de resistência e físico-químicos apresentados pelo couro indicam que ele pode ser utilizado para a confecção de vestuário e artefatos de couro em geral.
Resumo:
This study was perfonned in PSPs located at the CPAr-ACRE EMORAPA expcrirnental area and at the PC Peixoto management areas. AI CPA F-ACR E the managed area was meehanically exploited in 1992 and at PC Peixoto animal traction was used to extract the planks.