931 resultados para Tannery Wastewater


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A molecular approach was used to investigate a recently described candidate division of the domain Bacteria, TM7, currently known only from environmental 16S ribosomal DNA sequence data, A number of TM7-specific primers and probes were designed and evaluated. Fluorescence in situ hybridization (FISH) of a laboratory scale bioreactor using two independent TM7-specific probes revealed a conspicuous sheathed-filament morphotype, fortuitously enriched in the reactor. Morphologically, the filament matched the description of the Eikelboom morphotype 0041-0675 widely associated with bulking problems in activated-sludge wastewater treatment systems. Transmission electron microscopy of the bioreactor sludge demonstrated that the sheathed-filament morphotype had a typical gram-positive cell envelope ultrastructure. Therefore, TM7 is only the third bacterial lineage recognized to have gram-positive representatives. TM7-specific FISH analysis of two full-scale wastewater treatment plant sludges, including the one used to seed the laboratory scale reactor, indicated the presence of a number of morphotypes, including sheathed filaments. TM7-specific PCR clone libraries prepared from the two full-scale sludges yielded 23 novel TM7 sequences. Three subdivisions could be defined based on these data and publicly available sequences. Environmental sequence data and TM7-specific FISH analysis indicate that members of the TM7 division are present in a variety of terrestrial, aquatic, and clinical habitats. A highly atypical base substitution (Escherichia coli position 912; C to U) for bacterial 16S rRNAs was present in almost all TM7 sequences, suggesting that TM7 bacteria, like Archaea, may be streptomycin resistant at the ribosome level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Complete biological nutrient removal (BNR) in a single tank, sequencing batch reactor (SBR) process, is demonstrated here at full-scale on a typical domestic wastewater. The unique feature of the UniFed process is the introduction of the influent into the settled sludge blanket during the settling and decant periods of the SBR operation. This achieves suitable conditions for denitrification and anaerobic phosphate release which is critical to successful biological phosphorus removal, It also achieves a selector effect, which helps in generating a compact, well settling biomass in the reactor. The results of this demonstration show that it is possible to achieve well over 90% removal of GOD, nitrogen and phosphorus in such a process. Effluent quality achieved over a six-month operating period directly after commissioning was: 29 mg/l GOD, 0.5 mg/l NH4-N, 1.5 mg/l NOx-N and 1.5 mg/l PO4-P (50%-iles of daily samples). During an 8-day, intensive sampling period, the effluent BOD5 was

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper considers the question of which is better: the batch or the continuous activated sludge processes? It is an important question because dissension still exists in the wastewater industry as to the relative merits of each of the processes. A review of perceived differences in the processes from the point of view of two related disciplines, process engineering and biotechnology, is presented together with the results of previous comparative studies. These reviews highlight possible areas where more understanding is required. This is provided in the paper by application of the flexibility index to two case studies. The flexibility index is a useful process design tool that measures the ability of the process to cope with long term changes in operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited available hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Part 1 of this paper a methodology for back-to-back testing of simulation software was described. Residuals with error-dependent geometric properties were generated. A set of potential coding errors was enumerated, along with a corresponding set of feature matrices, which describe the geometric properties imposed on the residuals by each of the errors. In this part of the paper, an algorithm is developed to isolate the coding errors present by analysing the residuals. A set of errors is isolated when the subspace spanned by their combined feature matrices corresponds to that of the residuals. Individual feature matrices are compared to the residuals and classified as 'definite', 'possible' or 'impossible'. The status of 'possible' errors is resolved using a dynamic subset testing algorithm. To demonstrate and validate the testing methodology presented in Part 1 and the isolation algorithm presented in Part 2, a case study is presented using a model for biological wastewater treatment. Both single and simultaneous errors that are deliberately introduced into the simulation code are correctly detected and isolated. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a comprehensive study of sludge floc characteristics and their impact on compressibility and settleability of activated sludge in full scale wastewater treatment processes. The sludge flocs were characterised by morphological (floc size distribution, fractal dimension, filament index), physical (flocculating ability, viscosity, hydrophobicity and surface charge) and chemical (polymeric constituents and metal content) parameters. Compressibility and settleability were defined in terms of the sludge volume index (SVI) and zone settling velocity (ZSV). The floc morphological and physical properties had important influence on the sludge compressibility and settleability. Sludges containing large flocs and high quantities of filaments, corresponding to lower values of fractal dimension (D-f), demonstrated poor compressibility and settleability. Sludge flocs with high flocculating ability had lower SVI and higher ZSV, whereas high values of hydrophobicity, negative surface charge and viscosity of the sludge flocs correlated to high SVI and low ZSV. The quantity of the polymeric compounds protein. humic substances and carbohydrate in the sludge and the extracted extracellular polymeric substances (EPS) had significant positive correlations with SVI. The ZSV was quantitatively independent of the polymeric constituents. High concentrations of the extracted EPS were related to poor compressibility and settleability. The cationic ions Ca, Mg, Al and Fe in the sludge improved significantly the sludge compressibility and settleability. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines the influence of the chemical constituents of activated sludge and extracted extracellular polymeric substances (EPS) on the surface properties, hydrophobicity, surface charge (SC) and flocculating ability (FA) of activated sludge floes. Activated sludge samples from 7 different full-scale wastewater treatment plants were examined. Protein and humic substances were found to be the dominant polymeric compounds in the activated sludges and the extracted EPS, and they significantly affected the FA and surface properties, hydrophobicity and SC, of the sludge floes. The polymeric compounds proteins, humic substances and carbohydrates in the sludge floes and the extracted EPS contributed to the negative SC, but correlated negatively to the hydrophobicity of sludge floes. The quantity of protein and carbohydrate within the sludge and the extracted EPS was correlated positively to the FA of the sludge floes, while increased amounts of humic substances resulted in lower FA. In contrast, increased amounts of total extracted EPS had a negative correlation to FA. The results reveal that the quality and quantity of the polymeric compounds within the sludge floes is more informative, with respect to understanding the mechanisms involved in flocculation, than if only the extracted EPS are considered. This is an important finding as it indicates that extracting EPS may be insufficient to characterise the EPS. This is due to the low extraction efficiency and difficulties involved in the separation of EPS from other organic compounds. Correlations were observed between the surface properties and FA of the sludge floes., This confirms that the surface properties of the, sludge flocs play an important role in the bioflocculation process but that also other interactions like polymer entanglement are important. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The integrated control of nitrate recirculation and external carbon addition in a predenitrification biological wastewater treatment system is studied. The proposed control structure consists of four feedback control loops, which manipulate the nitrate recirculation and the carbon dosage flows in a highly coordinated manner such that the consumption of external carbon is minimised while the nitrate discharge limits (based on both grab and composite samples) are met. The control system requires the measurement of the nitrate concentrations at the end of both the anoxic and the aerobic zones. Distinct from ordinary control systems, which typically minimise the variation in the controlled variables, the proposed control system essentially maximises the diurnal variation of the effluent nitrate concentration and through this maximises the use of influent COD for denitrification, thus minimising the requirement for external carbon source. Simulation studies using a commonly accepted simulation benchmark show that the controlled system consistently achieves the designated effluent quality with minimum costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biological nitrogen removal via nitrite pathway in wastewater treatment is very important especially in the cost of aeration and as an electron donor for denitrification. Wastewater nitrification and nitrite accumulations were carried out in a biofilm reactor. The biofilm reactor showed almost complete nitrification and most of the oxidized ammonium was present as nitrite at the ammonium load of 1.2 kg N/m3/d. Nitrite accumulation was achieved by the selective inhibition of nitrite oxidizers by free ammonia and oxygen limitation. Nitrite oxidation activity was recovered as soon as the inhibition factor was removed. Fluorescence in situ hybridization studies of the nitrite accumulating biofilm system have shown that genus Nitrosomonas which is specifically hybridized with probe NSM 156 was the dominant nitrifying bacteria while Nitrospira was less abundant than those of normal nitrification systems. Further FISH analysis showed that the combinations of Nitrosomonas and Nitrospira cells were identified as important populations of nitrifying bacteria in an autotrophic nitrifying biofilm system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Activated sludge floes are a flocculated mass of microorganisms, extracellular polymeric substances (EPS) and adsorbed organic and inorganic material. The structure of the floes is very heterogeneous and floes with very different properties and morphologies may occur, depending on the conditions in the activated sludge treatment plant and wastewater composition. Present thinking suggests that cations, such as calcium, create cationic bridges with EPS excreted by the bacteria and thereby hold the various floe constituents together. However, due to the complex and heterogeneous nature of activated sludge, the mechanisms have neither been thoroughly investigated nor successfully quantified. A better understanding and description of the biological flocculation process is necessary in order to establish more efficient operational strategies. The main aim of this study was to get a comprehensive and unique insight into the floe properties of activated sludge and to assess the relative impact of chemical and physical parameters. A variety of sludges from full scale treatment plants with different settling properties were characterised. The interrelationships between floe parameters such as composition of EPS, surface properties and floe structure, and their effect on the flocculation and separation properties were assessed. The results indicate that the EPS, both in terms of quantity and quality, are very important for the floe properties of the activated sludge. However, presence of filaments may alter the physical properties of the floes considerably. The EPS showed positive correlations to sludge volume index (SVI) if only sludges with low or moderate numbers of filaments were included. The surface properties were more affected by the composition of the EPS than by the number of filaments. The EPS showed positive correlation to negative surface charge and a negative correlation to relative hydrophobicity and flocculation ability. The negative correlation between flocculation ability and amount of EPS was surprising. The shear sensitivity, measured as degree of erosion of floes when subjected to shear, was more affected by floe size and number of filaments than amount of EPS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biological nitrogen removal via the nitrite pathway in wastewater treatment is very important in Saving the cost of aeration and as an electron donor for denitrification. Wastewater nitrification and nitrite accumulation were carried out in a biofilm airlift reactor with autotrophic nitrifying biofilm. The biofilm reactor showed almost complete nitrification and most of the oxidized ammonium was present as nitrite at the ammonium load of 1.5 to 3.5 kg N/m3.d. Nitrite accumulation was stably achieved by the selective inhibition of nitrite oxidizers with free ammonia and dissolved oxygen limitation. Stable 100% conversion to nitrite could also be achieved even under the absence of free ammonia inhibition on nitrite oxidizers. Batch ammonium oxidation and nitrite oxidation with nitrite accumulating nitrifying biofilm showed that nitrite Oxidation was completely inhibited when free ammonia is higher than 0.2 mg N/L. However, nitrite oxidation activity was recovered as soon as the free ammonia concentration was below the threshold level when dissolved oxygen concentration was not the limiting factor. Fluorescence in situ hybridization analysis of cryosectioned nitrite accumulating nitrifying biofilm showed that the β-subclass of Proteobacteria, where ammonia oxidizers belong, was distributed outside the biofilm whereas the α-subclass of Proteobacteria, where nitrite oxidizers belong, was found mainly in the inner part of the biofilm. It is likely that dissolved oxygen deficiency or limitation in the inner part of the nitrifying biofilm, where nitrite oxidizers exist, is responsible for the complete shut down of the nitrite oxidizers activity under the absence of free ammonia inhibition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most of the wastewater treatment systems in small rural communities of the Cova da Beira region (Portugal) consist of constructed wetlands (CW) with horizontal subsurface flow (HSSF). It is believed that those systems allow the compliance of discharge standards as well as the production of final effluents with suitability for reuse. Results obtained in a nine-month campaign in an HSSF bed pointed out that COD and TSS removal were lower than expected. A discrete sampling also showed that removal of TC, FC and HE was not enough to fulfill international irrigation goals. However, the bed had a very good response to variation of incoming nitrogen loads presenting high removal of nitrogen forms. A good correlation between mass load and mass removal rate was observed for BOD5, COD, TN, NH4-N, TP and TSS, which shows a satisfactory response of the bed to the variable incoming loads. The entrance of excessive loads of organic matter and solids contributed for the decrease of the effective volume for pollutant uptake and therefore, may have negatively influenced the treatment capability. Primary treatment should be improved in order to decrease the variation of incoming organic and solid loads and to improve the removal of COD, solids and pathogenic. The final effluent presented good physical-chemical quality to be reused for irrigation, which is the most likely application in the area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório de estágio enquadra-se no âmbito do Trabalho Final de Mestrado (TFM) do curso de Engenharia Civil, área de especialização de Hidráulica, do Instituto Superior de Engenharia de Lisboa, e baseia-se na temática dos sistemas de abastecimento de água e drenagem de águas residuais. O estágio, intitulado de “Sistemas de Abastecimento de Agua e Saneamento Básico”, decorreu numa empresa de consultaria de engenharia denominada ENGIDRO – Estudos de Engenharia, Lda., vocacionada para a realização de estudos e projectos na área de Hidráulica, com particular incidência na Hidráulica Urbana e Saneamento Básico. O estágio iniciou-se com um adequado enquadramento profissional na empresa e incidiu principalmente no desenvolvimento de trabalhos de concepção e dimensionamento, a nível de projectos de execução, de sistemas de abastecimento de água e de saneamento básico, para 21 localidades da província de Lunda Sul, em Angola, com prestação de serviços para o Governo Provincial de Lunda Sul – Direcção Provincial da Energia e Aguas, juntamente com empresa CENGA – Consultores de Engenharia de Angola, S.A. Na prestação de serviços à entidade contratante foram efectuados trabalhos de campo, que consistiram principalmente em reconhecimentos do terreno, levantamentos topográficos e recolha de informação relevante sobre elementos condicionantes dos projectos (origens e disponibilidades de água, natureza e declive dos terrenos, tipos de infra-estruturas locais) e trabalhos de gabinete para compilação e análise da informação recolhida na elaboração dos projectos de execução, incluindo pecas desenhadas (desenhos pormenorizados) e peças escritas (memórias descritivas e justificativas, medições e orçamentos). Sendo os projectos destinados a aglomerados populacionais pouco desenvolvidos e com carências e condicionantes de diversa ordem (falta de energia eléctrica, de acessos, de telecomunicações, de meios técnicos e materiais, entre outros), prestou-se especial atenção aos aspectos da concepção, privilegiando soluções de baixa tecnologia, mais fáceis de explorar e manter com os recursos locais disponíveis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A água é um bem essencial ao ser humano. Nos dias de hoje é de extrema importância fazer chegar este bem às populações, um papel que no nosso país é desempenhado pelos municípios, por empresas municipais e por empresas concessionadas. Este relatório, enquadrado no âmbito do trabalho final de mestrado em Engenharia Civil, especialização em Hidráulica, no Instituto Superior de Engenharia de Lisboa, cujo título é “Conservação, Manutenção e Construção de Património Estratégico das Águas de Santarém”, relata a experiência de estágio do autor do presente relatório na A.S. – Empresa das Águas de Santarém – EM, S.A. O relatório aborda as temáticas do abastecimento de água, do tratamento de águas residuais, da construção de sistemas de saneamento e estações de tratamento de águas residuais, da reparação de equipamentos da empresa e do consumo de energia dos equipamentos da empresa. São descritas as actividades desenvolvidas pelo autor, que incluem o acompanhamento activo em visitas a obras de construção e manutenção de património, a monitorização e controlo de perdas de água, bem como a actualização em suporte informático do cadastro dos equipamentos pertencentes à A.S., com a criação de fichas de equipamento individuais e de um suporte informático para registo e consulta comparativa de consumos energéticos. Esta experiência de estágio permitiu ao autor um contacto com a realidade de uma empresa em toda a diversidade das actividades anteriormente nomeadas, que será descrita objectivamente nos capítulos do presente documento. O estágio foi claramente enriquecedor para o autor, fornecendo-lhe formação objectiva e a preparação necessária para a sua integração no mercado de trabalho nesta área específica da Engenharia Civil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reutilização das águas residuais tem vindo a afirmar-se como uma linha estratégica da conservação dos recursos hídricos, determinada sobretudo pela sua escassez e , também pela necessidade de proteger os meios receptores dos efluentes das estações de tratamento de águas residuais (ETAR). O objectivo do presente trabalho, consiste na avaliação da viabilidade da reutilização das águas residuais tratadas nos concelhos de Évora e de Redondo (Portugal), nas áreas potenciais de aplicação interessantes para esta região. A anteceder este estudo, para um enquadramento adequado e melhor compreensão do mesmo, apresenta-se o desenvolvimento, do estado da arte da reutilização das águas residuais tratadas nos aspectos relevantes ao trabalho. Desta forma, o desenvolvimento do estado da arte começa por tecer as considerações mais generalistas sobre a água, como é o seu ciclo hidrológico e as grandes problemáticas que a ele se encontram associadas, que são os fenómenos da escassez de água e da seca, fazendo alusão ao seu enquadramento em Portugal, na Europa e no mundo, para de seguida passar a uma retrospectiva da reutilização das águas residuais tratadas, também ela no mesmo enquadramento espacial, Portugal, Europa e mundial, onde vai acrecer as áreas dos concelhos de Évora e de Redondo, em virtude de serem as áreas de interesse nuclear ao desenvolvimento ao presente trabalho. Assim, são abordados os vários factores inerentes à viabilidade de um projecto desta natureza, sejam eles de carácter técnico, económico, ambiental e social, apresentando-se seguidamente o seu enquadramento normativo, com particular destaque para a regulamentação nacional. O desenvolvimento do estado da arte termina, com considerações mais técnicas ao desenvolvimento de um projecto deste âmbito, como são os que se encontram relacionados com a sua distribuição e o seu tratamento. Segue-se o caso de estudo, através da análise da viabilidade da reutilização das águas residuais tratadas nestes concelhos de Évora e de Redondo. A área destes concelhos é caracterizada relativamente à geografia, clima, fauna, flora, solos, demografia, actividades económicas e recursos hídricos, determinando-se o balanço hídrico da área em estudo. Apresenta-se a caracterização quantitativa e qualitativa das águas residuais tratadas que são produzidas nestes concelhos, que constituem uma origem de água alternativa para reutilização em aplicações cujo potencial interesse na área em estudo é identificada e quantificado. O persente trabalho termina com as conclusões e propostas para trabalhos futuros, referindo a importância da reutilização das águas residuais tratadas na estratégia de conservação da água, nesta região que apresenta escassos recursos hídricos, como é o caso destes concelhos. Neste sentido, três soluções são apontadas como possíveis à reutilização das águas residuais tratadas. A primeira tem a ver com a sua aplicação na actividade agrícola, através das culturas que apresentam maior rentabilidade, como é o caso da vinha e do olival. A segunda relaciona-se com a sua aplicação na rega paisagística, através da rega de campos de golfe e do Parque Ambiental do Redondo. A terceira reside nos usos urbanos não potáveis, como são a lavagem de viaturas, arruamentos e contentores de resíduos sólidos urbanos.