978 resultados para Stained Glass, Partenheim, Boppard, Carmelit Church, 15. Century
Resumo:
It has recently been reported that machined and microrough (micro) Brazilian titanium (Ti) implants have good production standards. The aim of this study was to evaluate in vivo bone formation around 2 different implant surfaces placed in dog's mandible. Thirty-two screw-typed Ti implants were used in this study. Mandibular premolars were extracted in 8 dogs and, after 12 weeks, 2 machined (Neodent Titamax, Brazil) and 2 micro implants (Neodent Titamax Porous, Brazil) were placed in each animal. Biopsies were taken at 3 and 8 weeks post-implantation and stained with Stevenel's blue and Alizarin red for histomorphometric measurements of bone-to-implant contact (BIC), bone area between threads (BABT) and bone area within the mirror area (BAMA). Data were analyzed statistically by two-way ANOVA (α=0.05). While at 3 weeks micro implants exhibited significantly more BIC than machined ones (55 ± 12.5% and 35.6 ± 15%, p<0.05), no significant difference in such parameter was detected at 8 weeks (51.2 ± 21% and 48.6 ± 18.1%, p>0.05). There were no significant differences in BABT and BAMA between the implants. Micro surfaces promoted higher contact osteogenesis. These data indicate that this commercial micro Ti implant surface enhances contact osteogenesis at an early post-implantation period when compared to the machined one.
Resumo:
This study evaluated histopathologically different methods of experimental induction of periapical periodontitis. The radiographic and microbiological evaluations have been performed in a previous investigation. Fifty-seven root canals from dogs' teeth were assigned to 4 groups. In GI (n=14) and GII (n=14), the root canals were exposed to oral environment for 180 days; in GIII (n=14) and GIV (n=15) the root canals were exposed for 7 days and then the access cavities were restored and remained sealed for 53 days. The root apices of GI and GIII were perforated, whilst those of GII and GIV remained intact. After induction of periapical periodontitis, the dogs were euthanized. Serial sections were obtained and stained with hematoxylin and eosin. Data of the histopathological evaluation were submitted to Kruskal-Wallis and Dunn's tests at 5% significance level. The inflammatory periapical reaction and resorption of mineralized tissues were less intense in GII than in the other groups (p<0.05). There was no histopathological difference among the experimentally induced periapical lesions in the teeth with coronal sealing. On the other hand, when coronal sealing was not performed, greater intensity of induced periapical periodontitis was observed in the teeth with apical perforation.
Resumo:
Dentin hypersensitivity (DH) is a painful response to stimulus applied to the open dentinal tubules of a vital tooth. It's a common oral condition, however, without an ideal treatment available yet. This work evaluated in vitro the effect of micron-sized particles from a novel bioactive glass-ceramic (Biosilicate) in occluding open dentinal tubules. A dentin disc model was employed to observe comparatively, using scanning electron microscopy (SEM), dentinal tubule occlusion by different products and deposition of hydroxyl carbonate apatite (HCA) on dentin surface by Biosilicate, after a single application: G1 - Dentifrice with potassium nitrate and fluoride; G2 - Two-step calcium phosphate precipitation treatment; G3 - Water-free gel containing Biosilicate particles (1%); G4 - Biosilicate particles mixed with distilled water in a 1:10 ratio; all of them after 1, 12 and 24 hours of immersion in artificial saliva. Fourier transform infrared spectroscopy (FTIR) was performed to detect HCA formation on dentin discs filled with Biosilicate after 2 minutes, 30 minutes and 12 hours of immersion in artificial saliva. SEM showed a layer of HCA formed on dentin surface after 24 hours by G4. G1, G2 and G3 promoted not total occlusion of open dentinal tubules after 24 hours. FTIR showed HCA precipitation on the dentin surface induced by Biosilicate after 30 minutes. The micron-sized particles from the bioactive glass-ceramic thus were able to induce HCA deposition in open dentinal tubules in vitro. This finding suggests that Biosilicate may provide a new option for treating DH.
Resumo:
Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns contaminated with microorganisms. Full crowns cast in a Ni-Cr alloy were assigned to one control group (n=6) and 5 experimental groups (n=18). The crowns were placed in flat-bottom glass balloons and were autoclaved. A microbial suspension of each type of strain - S. aureus, P. aeruginosa, S. mutans, E. faecalis and C. albicans- was aseptically added to each experimental group, the crowns being allowed for contamination during 30 min. The contaminated specimens were placed into recipients with the chemical disinfectants (1% and 2% sodium hypochlorite and 2% glutaraldehyde) for 5, 10 and 15 min. Thereafter, the crowns were placed into tubes containing different broths and incubated at 35ºC. The control specimens were contaminated, immersed in distilled water for 20 min and cultured in Thioglycollate broth at 35ºC. Microbial growth assay was performed by qualitative visual examination after 48 h, 7 and 12 days. Microbial growth was noticed only in the control group. In the experimental groups, turbidity of the broths was not observed, regardless of the strains and immersion intervals, thus indicating absence of microbial growth. In conclusion, all chemical disinfectants were effective in preventing microbial growth onto full metal crowns.
Resumo:
Caffeine induces loss of calcium and influences the normal development of bone. This study investigated the effects of coffee on bone metabolism in rats by biochemical measurement of calcium, bone densitometry and histometry. Male rats, born of female treated daily with coffee and with coffee intake since born, were anesthetized, subjected to extraction of the upper right incisor, and sacrificed 7, 21 and 42 days after surgery. Blood and urine samples were taken, and their maxilla radiographed and processed to obtain 5-µm-thick semi-serial sections stained with hematoxylin and eosin. The volume and bone quality were estimated using an image-analysis software. The results showed significantly greater amount of calcium in the plasma (9.40 ± 1.73 versus 9.80 ± 2.05 mg%) and urine (1.00 ± 0.50 versus 1.25 ± 0.70 mg/24 h) and significantly less amount in bone (90.0 ± 1.94 versus 86.0 ± 2.12 mg/mg bone), reduced bone mineral density (1.05 ± 0.11 versus 0.65 ± 0.15 mmAL), and lower amount of bone (76.19 ± 1.6 versus 53.41 ± 2.1 %) (ANOVA; p≤0.01) in animals treated with coffee sacrificed after 42 days. It may be concluded that coffee/caffeine intake caused serious adverse effects on calcium metabolism in rats, including increased levels of calcium in the urine and plasma, decreased bone mineral density and lower volume of bone, thus delaying the bone repair process.
Resumo:
This ex vivo study evaluated dentin permeability of the root canal in the apical third of different human groups of teeth. Eighty teeth were used, 8 from each dental group: maxillary and mandibular central incisors, lateral incisors and canines, maxillary first premolars (buccal and palatal roots), mandibular first premolars, and maxillary and mandibular second premolars, totalizing 88 roots that were distributed in 11 groups. The root canals were instrumented, irrigated with 1% NaOCl and 15% EDTA. Roots were immersed in 10% copper sulfate for 30 min and then in 1% rubeanic acid alcohol solution for the same period; this chemical reaction reveals dentin permeability by the formation of copper rubeanate, which is a dark-colored compound. Semi-serial 100-µm-thick cross-sections were obtained from the apical third of the roots. Five sections of each apical third were washed, dehydrated, cleared and mounted on glass slides for examination under optical microscopy. The percentage of copper ion infiltration and the amount of tubular dentin were quantified by morphometric analysis. The penetration of copper ions in the apical third ranged from 4.60 to 16.66%. The mandibular central and lateral incisors presented the highest dentin permeability (16.66%), while the maxillary canines and mandibular second and first premolars presented the lowest dentin permeability (4.60%, 4.80% and 5.71%, respectively; p<0.001). The other teeth presented intermediate permeability. In conclusion, dye penetration into dentin tubules at the apical region is strongly dependent on the group of teeth evaluated.
Resumo:
OBJECTIVE: This study evaluated the effect of ferrule preparation (Fp) on the fracture resistance of endodontically treated teeth, restored with composite resin cores with or without glass fiber posts. MATERIAL AND METHODS: Forty-four bovine teeth were sectioned 19 or 17 mm (2 mm ferrule) from the apex, endodontically treated and assigned to four groups (n = 11): Group 1: Fp and post; Group 2: Fp and without post; Group 3: without Fp and with post; Group 4: without Fp and without post. All specimens were restored with composite resin core and metal crown. Specimens were subjected to fracture resistance testing in a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey's tests (α=0.05). RESULTS: The mean fracture resistance values were as follows: Group 1: 573.3 N; Group 2: 552.5 N; Group 3: 275.3 N; Group 4: 258.6 N. Significantly higher fracture resistance was found for the groups with Fp (p<0.001). CONCLUSION: There was no statistically significant interaction between the "Fp" and "post" factors (p = 0.954). The ferrule preparation increased the fracture resistance of endodontically treated teeth. However, the use of glass fiber post showed no significant influence on the fracture resistance.
Resumo:
OBJECTIVE: The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents. MATERIAL AND METHODS: Morphological analysis of each post type was conducted under scanning electron microscopy (SEM). Bond strength was evaluated by microtensile test after bisecting the posts and re-bonding the two halves with the luting agents. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Failure modes were evaluated under optical microscopy and SEM. RESULTS: GF presented wider fibers and higher amount of matrix than CF, and G/CF presented carbon fibers surrounded by glass fibers, and both involved by matrix. For CF and GF, the dual-cured material presented significantly higher (p<0.05) bond strength than the self-cured agent. For the dual agent, CF presented similar bond strength to GF (p>0.05), but higher than that of G/CF (p<0.05). For the self-cured agent, no significant differences (p>0.05) were detected, irrespective of the post type. For GF and G/CF, all failures were considered mixed, while a predominance of adhesive failures was detected for CF. CONCLUSION: The bonding between fiber posts and luting agents was affected by the type of fibers and polymerization mode of the cement. When no surface treatment of the post is performed, the bonding between glass fiber post and dual-cured agent seems to be more reliable.
Resumo:
The objective of this work was to evaluate biaxial-flexural-strength (σf), Vickers hardness (HV), fracture toughness (K Ic), Young's modulus (E), Poisson's ratio (ν) and porosity (P) of two commercial glass-ceramics, Empress (E1) and Empress 2 (E2), as a function of the hot-pressing temperature. Ten disks were hot-pressed at 1065, 1070, 1075 and 1080 °C for E1; and at 910, 915, 920 and 925 °C for E2. The porosity was measured by an image analyzer software and s f was determined using the piston-on-three-balls method. K Ic and HV were determined by an indentation method. Elastic constants were determined by the pulse-echo method. For E1 samples treated at different temperatures, there were no statistical differences among the values of all evaluated properties. For E2 samples treated at different temperatures, there were no statistical differences among the values of σf, E, and ν, however HV and K Ic were significantly higher for 910 and 915 °C, respectively. Regarding P, the mean value obtained for E2 for 925 °C was significantly higher compared to other temperatures.
Resumo:
The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were performed, considering the initial weight loss temperature and glass transition temperature (Tg). Then, after photoactivation (600 mW/cm² - 40 s), the specimens (10 x 2 x 2 mm) were heat-treated following these conditions: 170ºC for 5, 10 or 15 min, embedded or not embedded in investment. Flexural strength was assessed as a means to evaluate the influence of different heat treatment periods and investment embedding on mechanical properties. The data were analyzed by ANOVA and Tukey's test (α = 0.05). TGA showed an initial weight loss temperature of 180ºC and DSC showed a Tg value of 157°C. Heat treatment was conducted in an oven (Flli Manfredi, Italy), after 37°C storage for 48 h. Flexural strength was evaluated after 120 h at 37°C storage. The results showed that different periods and investment embedding presented similar statistical values. Nevertheless, the direct composite resin with treatments presented higher values (178.7 MPa) compared to the indirect composite resin (146.0 MPa) and the same direct composite submitted to photoactivation only (151.7 MPa). Within the limitations of this study, it could be concluded that the heat treatment increased the flexural strength of the direct composite studied, leading to higher mechanical strength compared to the indirect composite.
Resumo:
Frequent use of Xylitol may decrease the S. mutans levels. However, very little is known about whether this effect on the levels of cariogenic bacteria is maintained after the interruption of short-term usage of xylitol. This study aimed at evaluating changes in mutans streptococci (MS) salivary levels after using a chewing gum containing xylitol. Twelve volunteers harboring > 10(5) CFU MS/ml saliva levels were asked to chew Happydent-xylit® for 5 minutes, 5 X/day, for 30 days. Saliva samples were collected at baseline, at 30 days after xylitol usage began, and at 30 days beyond its interruption. MS salivary levels were estimated. The average salivary levels of MS in the ten subjects who completed the study were 13.17 (NL-CFU) at baseline (A). After the 30 days experimental period (B), this average decreased to 9.45 (NL-CFU). Nine of ten subjects studied showed a reduction in MS salivary levels in relation to baseline, whereas salivary levels were maintained in the remaining subject. At thirty days beyond the interruption of xylitol usage (C), the average levels of MS were still reduced to 10.31 (NL-CFU). Multiple sample comparison using the Bonferroni test revealed that the decrease in MS levels observed from baseline (A) to the time immediately after 30 days of xylitol usage (B) was statistically significant (p < 0.05), and those levels were still decreased between baseline and 30 days beyond the interruption of xylitol usage (C). So, the use of xylitol induced a reduction in MS salivary levels after a short period of usage which persisted beyond its interruption.
Resumo:
The aim of this study was to assess the Knoop hardness of three high viscous glass ionomer cements: G1 - Ketac Molar; G2 - Ketac Molar Easymix (3M ESPE) and G3 - Magic Glass ART (Vigodent). As a parallel goal, three different methods for insertion of Ketac Molar Easymix were tested: G4 - conventional spatula; G5 - commercial syringe (Centrix) and G6 - low-cost syringe. Ten specimens of each group were prepared and the Knoop hardness was determined 5 times on each specimen with a HM-124 hardness machine (25 g/30 s dwell time) after 24 h, 1 and 2 weeks. During the entire test period, the specimens were stored in liquid paraffin at 37ºC. Significant differences were found between G3 and G1/G2 (two-way ANOVA and Tukey's post hoc test; p<0.01). There was no significant difference in the results among the multiple ways of insertion. The glass ionomer cement Magic Glass ART showed the lowest hardness, while the insertion technique had no significant influence on hardness.
Resumo:
OBJETIVO: avaliar os efeitos da administração da associação zidovudina-lamivudina-ritonavir nos fígados e rins de ratas prenhes e seus conceptos do ponto de vista morfológico e fisiológico. MÉTODOS: 40 ratas albinas prenhes foram aleatoriamente divididas em 4 grupos: 1 controle (Ctrl: controle de veículo) e 3 experimentais (Exp1x, Exp3x e Exp9x). Estes últimos foram tratados por solução oral de zidovudina/lamivudina/ritonavir (Exp1x: 10/5/20 mg/kg; Exp3x: 30/15/60 mg/kg; Exp9x: 90/45/180 mg/kg). As drogas e o veículo foram administrados por gavagem, desde o 1º até o 20º dia de prenhez. No último dia do experimento, todos os animais foram anestesiados e sangue foi retirado da cavidade cardíaca para avaliação sérica das enzimas aspartato aminotransferase (AST) e alanina aminotransferase (ALT), por método calorimétrico, bem como da ureia, determinada por método cinético-enzimático, e creatinina, por método cinético-colorimétrico. Em seguida, fragmentos dos fígados e rins maternos e fetais foram coletados, fixados em formol a 10% e processados segundo os métodos histológicos para inclusão em parafina. Cortes com 5 µm de espessura foram corados pela hematoxilina-eosina (HE) e analisados por microscopia de luz. Na leitura das lâminas, considerou-se o padrão de normalidade para fígado e rins, tais como: hepatócitos, espaço porta íntegros e veias hepáticas bem definidas. Nos rins, a presença de corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Nos fígados fetais considerou-se, ainda, a morfologia das células da linhagem eritrocitária nas diferentes fases do desenvolvimento, bem como os megacariócitos. Quando houve alteração da coloração padrão estabelecida para as estruturas hepáticas e renais, alteração na morfologia de núcleos, rompimento de limites de alguma organela citoplasmática, presença de congestão vascular, tudo isso foi entendido como provavelmente provocado pelas drogas em sua(s) dose(s) de aplicação. A avaliação estatística foi realizada por análise de variância (ANOVA), completada pelo teste de Tukey-Kramer (p<0,05). RESULTADOS: os fígados maternos dos grupos Ctrl, Exp1x e Exp3x mostraram hepatócitos típicos, espaço porta íntegros e veias hepáticas com aspecto normal. No fígado materno do grupo Exp9x, foram encontrados hepatócitos com sinais de atrofia e apoptose (eosinofilia citoplasmática e núcleos picnóticos). Além disso, identificou-se vasodilatação dos capilares sinusoides (congestão). Os rins maternos dos grupos Ctrl e Exp1x apresentaram-se normais, com corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Já nos grupos Exp3x e Exp9x, foram encontrados congestão vascular, glomérulos pequenos ricos em células contendo núcleos hipercromáticos, sendo mais intensos no Exp9x. Com relação aos fígados e rins fetais, não foram observadas alterações morfológicas ou fisiológicas nos grupos estudados. Encontrou-se aumento significante nos níveis da AST (305,70±55,80; p<0,05) e da creatinina (0,50±0,09; p<0,05) no grupo Exp9x. CONCLUSÕES: nossos resultados evidenciam que a administração da associação zidovudina/lamivudina/ritonavir a ratas prenhes em altas doses causa alterações morfológicas e funcionais nos fígados e rins maternos. Não houve alterações nem morfológicas nem fisiológicas nos fígados e rins fetais.
Resumo:
Conforme previsões do último relatório do IPCC (Intergovernmental Panel of Climatic Change) em 2007, até meados deste século haverá um aumento na concentração de CO2 na atmosfera podendo chegar a 720 μmol mol-1. Consequentemente haverá uma elevação da temperatura de até +3 °C, o que ocorrerá em conjunto com mudanças no padrão de precipitação. O mesmo relatório sugere que isto poderá acarretar uma substituição gradual da floresta tropical por vegetação similar a uma savana na parte oriental da Amazônia, porém nada é conclusivo. Diante dessas possibilidades, pergunta-se - Como as espécies de árvores que compõem as regiões de alagamento da Amazônia irão responder às alterações climáticas por vir? Apesar dessas previsões serem pessimistas, o alagamento ainda ocorrerá por vários anos na Amazônia e é de grande importância compreender os efeitos do alagamento sobre as respostas fisiológicas das plantas num contexto das mudanças climáticas. Os principais efeitos sobre a sinalização metabólica e hormonal durante o alagamento são revisados e os possíveis efeitos que as mudanças climáticas poderão ter sobre as plantas amazônicas são discutidos. As informações existentes sugerem que sob alagamento, as plantas tendem a mobilizar reservas para suprir a demanda de carbono necessário para a manutenção do metabolismo sob o estresse da falta de oxigênio. Até certo limite, com o aumento da concentração de CO2, as plantas tendem a fazer mais fotossíntese e a produzir mais biomassa, que poderão aumentar ainda mais com um acréscimo de temperatura de até 3 °C. Alternativamente, com o alagamento, há uma diminuição geral do potencial de crescimento e é possível que quando em condições de CO2 e temperatura elevados os efeitos positivo e negativo se somem. Com isso, as respostas fisiológicas poderão ser amenizadas ou, ainda, promover maior crescimento para a maioria das espécies de regiões alagáveis até o meio do século. Porém, quando a temperatura e o CO2 atingirem valores acima dos ótimos para a maioria das plantas, estas possivelmente diminuirão a atividade fisiológica.
Resumo:
Folhas de Myrcia multiflora (Lam.) DC. são usadas na medicina popular como hipoglicemiantes. O objetivo deste trabalho foi caracterizar morfológica e anatomicamente as folhas desta planta, de modo que os dados obtidos possam ser utilizados como referência em exames de controle de qualidade de amostras de fármacos, com vistas a verificar a autenticidade. Folhas inteiras foram diafanizadas e coradas para o estudo da nervação. Secções transversais do pecíolo e transversais e paradérmicas da lâmina foliar foram analisadas em microscópio óptico (MO) e a superfície do limbo foi observada, também, em microscopia eletrônica de varredura (MEV). Foram aplicados testes histoquímicos em material fresco, para identificação e localização de glicídios, amido, taninos, lignina, cristais e sílica. Morfologicamente, a folha é simples, oval-elíptica, com margem inteira, base aguda, ápice acuminado e textura cartácea. A venação é do tipo camptódromo-broquidódromo. Anatomicamente, a folha é hipostomática, com mesofilo compacto e dorsiventral, com três estratos de parênquima paliçádico. A epiderme é uniestratificada, silicificada em algumas regiões e as células exibem paredes anticlinais retas. Em posição subepidérmica ocorrem numerosas cavidades secretoras de óleos essenciais. Os feixes vasculares são colaterais e acompanhados por séries cristalíferas. Os dados obtidos são comparados com os de outras espécies de Myrtaceae e conclui-se que as características morfológicas e anatômicas de M. multiflora contribuem para a diagnose.