854 resultados para Roost loss
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Uterine leiomyomas are extremely common, benign, smooth muscle tumors that represent a significant public health problem. Although there have been few molecular studies of uterine leiomyomas, most of them have reported a very low frequency of loss of heterozygosity (LOH) in different regions of the genome. The detection of LOH has been used to identify genomic regions that harbor tumor suppressor genes and to characterize different tumor types. We have used a set of 15 microsatellite polymorphism markers to examine the frequency of allele loss in a panel of 64 human uterine leiomyomas matched to normal DNAs. The markers were chosen from regions involved in losses identified by comparative genomic hybridization in a subset of uterine leiomyomas described in a previous report. DNA from tumors and normal tissue was amplified by the polymerase chain reaction and subsequently analyzed using an ABI Prism 377 DNA automated sequencer. The frequency of LOH observed was low, except for the markers D15S87 (15q26.3), D7S493 (7p15.3), and D7S517 (7p22.2). No changes in microsatellite size were detected in our samples. These results provide useful clues for identifying putative tumor suppressor genes associated with a subset of uterine leiomyomas. (C) 2004 Wiley-Liss, Inc.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To report a rare case of self-inflicted eye injury secondary to obsessive-compulsive disorder (OCD).Method: Case report.Results: A 41 year-old patient had significant bilateral visual loss and blunt trauma through touching his ocular cavities due to recurrent doubts regarding their shape and urges to check the format of bones and cartilages. Differential diagnosis with tic disorders is discussed, and the patient's treatment approach is described.Conclusion: Although rare, severe clinical complications can occur in OCD. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Aims: To determine the occurrence of isolated and recurrent episodes of conductive hearing loss (CHL) during the first two years of life in very low birth weight (VLBW) infants with and without bronchopulmonary dysplasia (BPD).Study design, subjects and outcome measures: In a longitudinal clinical study. 187 children were evaluated at 6, 9, 12,15 18 and 24 months of age by visual reinforcement audiometry, tympanometry and auditory brain response system.Results: of the children with BPD, 54.5% presented with episodes of CHL, as opposed to 34.7% of the children without BPD. This difference was found to be statistically significant. The recurrent or persistent episodes were more frequent among children with BPD (25.7%) than among those without BPD (8.3%). The independent variables that contributed to this finding were small for gestational age and a 5 min Apgar score.Conclusions: Recurrent CHL episodes are more frequent among VLBW infants with BPD than among VLBW infants without BPD. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer's recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Heat stress has negative effects on pregnancy rates of lactating dairy cattle. There are genetic differences in tolerance to heat stress; Bos taurus indicus (B. t. indicus) cattle and embryos are more thermotolerant than Bos taurus taurus (B. t. taurus). In the present study, the effects of sire and sire breed on conception and embryonic/fetal loss rates of lactating Holstein cows during the Brazilian summer were determined. In Experiment 1, cows (n = 302) were AI after estrus detection or at a fixed-time with semen from one Gyr (B. t. indicus) or one Holstein sire (B. t. taurus). Pregnancy was diagnosed 80 days after AI. In Experiment 2, cows (n = 811) were AI with semen from three Gyr and two Holstein sires. Pregnancy was diagnosed at 30-40 and at 60-80 days after AI. Cows diagnosed pregnant at the first examination but non-pregnant at the second were considered as having lost their embryo or fetus. Data were analyzed by logistic regression. The model considered the effect of sire within breed, sire breed, days postpartum, period of lactation, and AI type (AI after estrus versus fixed-time). There was no effect of the AI type, days postpartum or milk production on conception or embryonic loss rates. The use of Gyr bulls increased pregnancy rate when compared to Holstein bulls [9.1% (60/657) versus 5.0% (23/456), respectively, P = 0.008; data from Experiments 1 and 2 combined]. Additionally, in Experiment 2, cows inseminated using semen from sire #4 (Gyr) had lower embryonic loss (10%) when compared with other B. t. indicus (35.3% and 40%) or B. t. taurus sires (18.2% and 38.5%, P = 0.03). In conclusion, the use of B. t. indicus sires may result in higher conception rates in lactating Holstein cows during summer heat stress. Moreover, sire can affect embryonic loss and selection of bulls according to this criterion may result in higher parturition rates in lactating Holstein cows. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study used bovine ribs to comparatively assess the deformation, roughness, and mass loss for 3 different types of surface treatments with burs, used in osteotomies, for the installation of osseointegrated implants.Materials and Methods: The study used 25 bovine ribs and 3 types of helical burs (2.0 mm and 3.0 mm) for osteotomies during implant placement (a steel bur [G1], a bur with tungsten carbide film coating in a carbon matrix [G2], and a zirconia bur [G3]), which were subdivided into 5 subgroups: 1, 2, 3, 4, and 5, corresponding to 0, 10, 20, 30, and 40 perforations, respectively. The surface roughness (mean roughness [Ra], partial roughness, and maximum roughness) and mass (in grams) of all the burs were measured, and the burs were analyzed in a scanning electron microscope before and after use. Data were tabulated and statistically analyzed by use of the Kruskal-Wallis test, and when a statistically significant difference was found, the Dunn test was used.Results: There was a loss of mass in all groups (G1, G2, and G3), and this loss was gradual, according to the number of perforations made (1, 2, 3, 4, and 5). However, this difference was not statistically significant (P < .05). Regarding the roughness, G3 presented an increase in Ra, partial roughness, and maximum roughness (P < .05) compared with G2 and an increase in Ra compared with G1. There was no statistically significant difference (P > .05) between G1 and G2. The scanning electron microscopy analysis found areas of deformation in all the 2.0-mm samples, with loss of substrates, and this characteristic was more frequent in G3.Conclusions: The 2.0-mm zirconia burs had a greater loss of substrates and abrasive wear in the cutting area. They also presented an increased roughness when compared with the steel and the tungsten carbide coating film in carbon matrix. There was no statistically significant difference (P < .05) between G1 and G2 in any mechanical test carried out. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:e608-e621, 2012
Resumo:
Purpose: The vertical location of the implant-abutment connection influences the subsequent reaction of the peri-implant bone. It is not known, however, whether any additional influence is exerted by different microgap configurations. Therefore, the radiographic bone reactions of two different implant systems were monitored for 6 months. Materials and Methods: In eight mongrel dogs, two implants with an internal Morse-taper connection (INT group) were placed on one side of the mandible; the contralateral side received two implants with an external-hex connection (EXT group). on each side, one implant was aligned at the bone level (equicrestal) and the second implant was placed 1.5 mm subcrestal. Healing abutments were placed 3 months after submerged healing, and the implants were maintained for another 3 months without prosthetic loading. At implant placement and after 1, 2, 3, 4, 5, and 6 months, standardized radiographs were obtained, and peri-implant bone levels were measured with regard to microgap location and evaluated statistically. Results: All implants osseointegrated clinically and radiographically. The overall mean bone loss was 0.68 +/- 0.59 mm in the equicrestal INT group, 1.32 +/- 0.49 mm in the equicrestal EXT group, 0.76 +/- 0.49 mm in the subcrestal INT group, and 1.88 +/- 0.81 mm in the subcrestal EXT group. The differences between the INT and EXT groups were statistically significant (paired t tests). The first significant differences between the internal and external groups were seen at month 1 in the subcrestal groups and at 3 months in the equicrestal groups. Bone loss was most pronounced in the subcrestal EXT group. Conclusions: Within the limits of this study, different microgap configurations can cause different amounts of bone loss, even before prosthetic loading. Subcrestal placement of a butt-joint microgap design may lead to more pronounced radiographic bone loss. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:941-946
Resumo:
Purpose: The implant-abutment connection (microgap) influences the pen-implant bone morphology. However, it is unclear if different microgap configurations additionally modify bone reactions. This preliminary study aimed to radiographically monitor pen-implant bone levels in two different microgap configurations during 3 months of nonsubmerged healing. Materials and Methods: Six dogs received two implants with internal Morse taper connection (INT group) on one side of the mandible and two implants with external-hex connection (EXT group) on the other side. One implant on each side was positioned at bone level (equicrestal); the second implant was inserted 1.5 mm below the bone crest (subcrestal). Healing abutments were attached directly after implant insertion, and the implants were maintained for 3 months without prosthetic loading. At implant placement and 1, 2, and 3 months, standardized radiographs were taken to monitor pen-implant bone levels. Results: All implants osseointegrated. A total bone loss of 0.48 +/- 0.66 mm was measured in the equicrestal INT group, 0.69 +/- 0.43 mm in the equicrestal EXT group, 0.79 +/- 0.93 mm in the subcrestal INT group, and 1.56 +/- 0.53 mm in the subcrestal EXT group (P>.05, paired t tests). Within the four groups, bone loss over time became significantly greater in the EXT groups than in the INT groups. The greatest bone loss was noted in the subcrestal EXT group. Conclusion: Within the limits of this animal study, it seems that even without prosthetic loading, different microgap configurations exhibit different patterns of bone loss during nonsubmerged healing. Subcrestal positioning of an external butt joint microgap may lead to faster radiographic bone loss. Int J Prosthodont 2011;24:445-452.