1000 resultados para Optical measures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major problem with holographic optical tweezers (HOTs) is their incompatibility with laser-based position detection methods, such as back-focal-plane interferometry (BFPI). The alternatives generally used with HOTs, like high-speed video tracking, do not offer the same spatial and temporal bandwidths. This has limited the use of this technique in precise quantitative experiments. In this paper, we present an optical trap design that combines digital holography and back-focal-plane displacement detection. We show that, with a particularly simple setup, it is possible to generate a set of multiple holographic traps and an additional static non-holographic trap with orthogonal polarizations and that they can be, therefore, easily separated for measuring positions and forces with the high positional and temporal resolutions of laser-based detection. We prove that measurements from both polarizations contain less than 1% crosstalk and that traps in our setup are harmonic within the typical range. We further tested the instrument in a DNA stretching experiment and we discuss an interesting property of this configuration: the small drift of the differential signal between traps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four series of five specimens each were investigated for static and fatigue strength. These four series differed in that there were two variables, the first being the subsidence of concrete around reinforcing bars and the second being shrinkage due to two different curing conditions. The combinations of these variables were then compared to each other by use of, load-deflection curves and S-H fatigue curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Astrocytes fulfill a central role in regulating K+ and glutamate, both released by neurons into the extracellular space during activity. Glial glutamate uptake is a secondary active process that involves the influx of three Na+ ions and one proton and the efflux of one K+ ion. Thus, intracellular K+ concentration ([K+]i) is potentially influenced both by extracellular K+ concentration ([K+]o) fluctuations and glutamate transport in astrocytes. We evaluated the impact of these K+ ion movements on [K+]i in primary mouse astrocytes by microspectrofluorimetry. We established a new noninvasive and reliable approach to monitor and quantify [K+]i using the recently developed K+ sensitive fluorescent indicator Asante Potassium Green-1 (APG-1). An in situ calibration procedure enabled us to estimate the resting [K+]i at 133±1 mM. We first investigated the dependency of [K+]i levels on [K+]o. We found that [K+]i followed [K+]o changes nearly proportionally in the range 3-10 mM, which is consistent with previously reported microelectrode measurements of intracellular K+ concentration changes in astrocytes. We then found that glutamate superfusion caused a reversible drop of [K+]i that depended on the glutamate concentration with an apparent EC50 of 11.1±1.4 µM, corresponding to the affinity of astrocyte glutamate transporters. The amplitude of the [K+]i drop was found to be 2.3±0.1 mM for 200 µM glutamate applications. Overall, this study shows that the fluorescent K+ indicator APG-1 is a powerful new tool for addressing important questions regarding fine [K+]i regulation with excellent spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of binding of a glycolipid-anchored protein (the promastigote surface protease, PSP) to planar lecithin bilayers is studied by an integrated optics technique, in which the bilayer membrane is supported on an optical wave guide and the phase velocities of guided light modes in the wave guide are measured. From these velocities, the optical parameters of the membrane and PSP layers deposited on the waveguide are determined, yielding in particular the mass of PSP bound to the membrane, which is followed in real time. From a comparison of the binding rates of PSP and PSP from which the lipid moiety has been removed, it is shown that the lipid moiety plays a key role in anchoring the protein to the membrane. Specific and nonspecific binding of antibodies to membrane-anchored PSP is also investigated. As little as a fifth of a monolayer of PSP is sufficient to suppress the appreciable nonspecific binding of antibodies to the membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The present study was designed to evaluate surgeons' strategies and adherence to preventive measures against surgical site infections (SSIs). MATERIALS AND METHODS: All surgeons participating in a prospective Swiss multicentric surveillance program for SSIs received a questionnaire developed from the 2008 National (United Kingdom) Institute for Health and Clinical Excellence (NICE) clinical guidelines on prevention and treatment of SSIs. We focused on perioperative management and surgical technique in hernia surgery, cholecystectomy, appendectomy, and colon surgery (COL). RESULTS: Forty-five of 50 surgeons contacted (90%) responded. Smoking cessation and nutritional screening are regularly propagated by 1/3 and 1/2 of surgeons, respectively. Thirty-eight percent practice bowel preparation before COL. Preoperative hair removal is routinely (90%) performed in the operating room with electric clippers. About 50% administer antibiotic prophylaxis within 30 min before incision. Intra-abdominal drains are common after COL (43%). Two thirds of respondents apply nonocclusive wound dressings that are manipulated after hand disinfection (87%). Dressings are usually changed on postoperative day (POD) 2 (75%), and wounds remain undressed on POD 2-3 or 4-5 (36% each). CONCLUSIONS: Surgeons' strategies to prevent SSIs still differ widely. The adherence to the current NICE guidelines is low for many procedures regardless of the available level of evidence. Further research should provide convincing data in order to justify standardization of perioperative management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Concerns about self-reports have led to calls for objective measures of blood alcohol concentration (BAC). The present study compared objective measures with self-reports. Methods: BAC from breath or blood samples were obtained from 272 randomly sampled injured patients who were admitted to a Swiss emergency department (ED). Self-reports were compared a) between those providing and refusing a BAC test, and b) to estimated peak BAC (EPBAC) values based on BACs using the Widmark formula. Results: Those providing BACs were significantly (P < 0.05) younger, more often male, and less often reported alcohol consumption before injury, but consumed higher quantities when drinking. Eighty-eight percent of those with BAC measures gave consistent reports (positive or negative). Significantly more patients reported consumption with negative BAC measures (N = 29) than vice versa (N = 3). Duration of consumption and times between injury and BAC measurement predicted EPBAC better than did the objective BAC measure. Conclusions: There is little evidence that patients who provide objective BAC measures deliberately conceal consumption. ED studies must rely on self-reports, eg, take the time period between injury and ED admission into account. Clearly, objective measures are of clinical relevance, eg, to provide optimal treatment in the ED. However, they may be less relevant to establishing effects in an epidemiologic sense, such as estimating risk relationships. In this respect, efforts to increase the validity and reliability of self-reports should be preferred over the collection of additional objective measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the optical properties of Na0.7CoO2 single crystals, measured over a broad spectral range as a function of temperature (T). The capability to cover the energy range from the far-infrared up to the ultraviolet allows us to perform reliable Kramers-Kronig transformation, in order to obtain the absorption spectrum (i.e., the complex optical conductivity). To the complex optical conductivity we apply the generalized Drude model, extracting the frequency dependence of the scattering rate (Gamma) and effective mass (m*) of the itinerant charge carriers. We find that Gamma(omega) at low temperatures and for similar to omega. This suggests that Na0.7CoO2 is at the verge of a spin-density-wave metallic phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intensification of pharmacotherapy in persons with poorly controlled chronic conditions has been proposed as a clinically meaningful process measure of quality. OBJECTIVE: To validate measures of treatment intensification by evaluating their associations with subsequent control in hypertension, hyperlipidemia, and diabetes mellitus across 35 medical facility populations in Kaiser Permanente, Northern California. DESIGN: Hierarchical analyses of associations of improvements in facility-level treatment intensification rates from 2001 to 2003 with patient-level risk factor levels at the end of 2003. PATIENTS: Members (515,072 and 626,130; age >20 years) with hypertension, hyperlipidemia, and/or diabetes mellitus in 2001 and 2003, respectively. MEASUREMENTS: Treatment intensification for each risk factor defined as an increase in number of drug classes prescribed, of dosage for at least 1 drug, or switching to a drug from another class within 3 months of observed poor risk factor control. RESULTS: Facility-level improvements in treatment intensification rates between 2001 and 2003 were strongly associated with greater likelihood of being in control at the end of 2003 (P < or = 0.05 for each risk factor) after adjustment for patient- and facility-level covariates. Compared with facility rankings based solely on control, addition of percentages of poorly controlled patients who received treatment intensification changed 2003 rankings substantially: 14%, 51%, and 29% of the facilities changed ranks by 5 or more positions for hypertension, hyperlipidemia, and diabetes, respectively. CONCLUSIONS: Treatment intensification is tightly linked to improved control. Thus, it deserves consideration as a process measure for motivating quality improvement and possibly for measuring clinical performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the time course of retinal morphologic changes in a patient with acute retinal pigment epithelitis (ARPE) using spectral domain optical coherence tomography (SD-OCT). METHODS: A 30-year old man was referred for blurred vision of his right eye after five days that appeared suddenly 15 days after recovery from a flu-like syndrome. SD-OCT was performed immediately, followed by fluorescein and infracyanine angiography at eight days and then at three weeks. RESULTS: At presentation, a bubble of sub-macular deposit was observed on the right macula with central golden micronodules in a honeycomb pattern. SD-OCT showed an "anterior dislocation" of all the retinal layers up to the inner/outer segment (IS/OS) line and irregular deposits at the OS level together with thickening of the retinal pigment epithelial (RPE) layer. As visual acuity increased, eight days later, the OCT showed reduction of the sub-retinal deposits and an abnormal hyperflectivity of the sub-retinal and RPE layers was observed. The patient showed a positive serology for picornavirus. DISCUSSION: The acute SD-OCT sections of this patient with ARPE were compared with histological sections of a 35 day old Royal College of Surgeons rat. Similar findings could be observed, with preservation of the IS/OS line and accumulation of debris at the OS level, suggesting that ARPE symptoms could result from a transient phagocytic dysfunction of the RPE at the fovea, inducing reversible accumulation of undigested OS. Picornaviruses comprising enterovirus and coxsachievirus described as being associated with acute chorioretinitis. In this case, it was responsible for ARPE. CONCLUSION: We hypothesize that ARPE syndrome results from a transient dysfunction of RPE, which can occur as a post viral reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paperin pinnan karheus on yksi paperin laatukriteereistä. Sitä mitataan fyysisestipaperin pintaa mittaavien laitteiden ja optisten laitteiden avulla. Mittaukset vaativat laboratorioolosuhteita, mutta nopeammille, suoraan linjalla tapahtuville mittauksilla olisi tarvetta paperiteollisuudessa. Paperin pinnan karheus voidaan ilmaista yhtenä näytteelle kohdistuvana karheusarvona. Tässä työssä näyte on jaettu merkitseviin alueisiin, ja jokaiselle alueelle on laskettu erillinen karheusarvo. Karheuden mittaukseen on käytetty useita menetelmiä. Yleisesti hyväksyttyä tilastollista menetelmää on käytetty tässä työssä etäisyysmuunnoksen lisäksi. Paperin pinnan karheudenmittauksessa on ollut tarvetta jakaa analysoitava näyte karheuden perusteella alueisiin. Aluejaon avulla voidaan rajata näytteestä selvästi karheampana esiintyvät alueet. Etäisyysmuunnos tuottaa alueita, joita on analysoitu. Näistä alueista on muodostettu yhtenäisiä alueita erilaisilla segmentointimenetelmillä. PNN -menetelmään (Pairwise Nearest Neighbor) ja naapurialueiden yhdistämiseen perustuvia algoritmeja on käytetty.Alueiden jakamiseen ja yhdistämiseen perustuvaa lähestymistapaa on myös tarkasteltu. Segmentoitujen kuvien validointi on yleensä tapahtunut ihmisen tarkastelemana. Tämän työn lähestymistapa on verrata yleisesti hyväksyttyä tilastollista menetelmää segmentoinnin tuloksiin. Korkea korrelaatio näiden tulosten välillä osoittaa onnistunutta segmentointia. Eri kokeiden tuloksia on verrattu keskenään hypoteesin testauksella. Työssä on analysoitu kahta näytesarjaa, joidenmittaukset on suoritettu OptiTopolla ja profilometrillä. Etäisyysmuunnoksen aloitusparametrit, joita muutettiin kokeiden aikana, olivat aloituspisteiden määrä ja sijainti. Samat parametrimuutokset tehtiin kaikille algoritmeille, joita käytettiin alueiden yhdistämiseen. Etäisyysmuunnoksen jälkeen korrelaatio oli voimakkaampaa profilometrillä mitatuille näytteille kuin OptiTopolla mitatuille näytteille. Segmentoiduilla OptiTopo -näytteillä korrelaatio parantui voimakkaammin kuin profilometrinäytteillä. PNN -menetelmän tuottamilla tuloksilla korrelaatio oli paras.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate choroidal vascular abnormalities in peripheral exudative hemorrhagic chorioretinopathy, using dynamic ultrawide-field fluorescein angiography (FA) and indocyanine green angiography (ICGA).¦DESIGN: Prospective observational case series.¦METHODS: This institutional study comprised a consecutive series of 40 patients (48 eyes) with peripheral exudative hemorrhagic chorioretinopathy. Choroidal vascular abnormalities were assessed with dynamic ultrawide-field (150-degree) FA and ICGA, using the Staurenghi 230 SLO Retina Lens and the Heidelberg scanning laser ophthalmoscope. The main outcome measures were morphologic descriptions of structural vascular abnormalities and choroidal hemodynamics (comparison with 30 normal eyes).¦RESULTS: The peripheral mass lesions were highly exudative and hemorrhagic, and usually associated with a pigment epithelium detachment. FA revealed nonspecific alterations corresponding to the visible fundoscopic changes (window defects, blockage, staining), but no neovascular membrane. However, despite frequent masking, ICGA showed hyperfluorescent polyp-like structures in the choroid of the lesion area in 33 eyes (69%) and an abnormal choroidal vascular network in 24 eyes (50%). The abnormal choroidal vascular network filled in the arterial or early venous phase, while the polyp-like structures filled some seconds later. Optical coherence tomography revealed the typical dome-shaped elevation of the pigment epithelium over the vascular polyps. Peripheral choriocapillaris closure was observed as well as dilated shunting vessels.¦CONCLUSION: Peripheral exudative hemorrhagic chorioretinopathy shares many characteristics (polyp-like choroidal telangiectases, abnormal choroidal vascular networks, exudative and hemorrhagic presentation) with polypoidal choroidal vasculopathy. Clarification of the precise role of these abnormalities requires further studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Assessment of the proportion of patients with well controlled cardiovascular risk factors underestimates the proportion of patients receiving high quality of care. Evaluating whether physicians respond appropriately to poor risk factor control gives a different picture of quality of care. We assessed physician response to control cardiovascular risk factors, as well as markers of potential overtreatment in Switzerland, a country with universal healthcare coverage but without systematic quality monitoring, annual report cards on quality of care or financial incentives to improve quality. METHODS: We performed a retrospective cohort study of 1002 randomly selected patients aged 50-80 years from four university primary care settings in Switzerland. For hypertension, dyslipidemia and diabetes mellitus, we first measured proportions in control, then assessed therapy modifications among those in poor control. "Appropriate clinical action" was defined as a therapy modification or return to control without therapy modification within 12 months among patients with baseline poor control. Potential overtreatment of these conditions was defined as intensive treatment among low-risk patients with optimal target values. RESULTS: 20% of patients with hypertension, 41% with dyslipidemia and 36% with diabetes mellitus were in control at baseline. When appropriate clinical action in response to poor control was integrated into measuring quality of care, 52 to 55% had appropriate quality of care. Over 12 months, therapy of 61% of patients with baseline poor control was modified for hypertension, 33% for dyslipidemia, and 85% for diabetes mellitus. Increases in number of drug classes (28-51%) and in drug doses (10-61%) were the most common therapy modifications. Patients with target organ damage and higher baseline values were more likely to have appropriate clinical action. We found low rates of potential overtreatment with 2% for hypertension, 3% for diabetes mellitus and 3-6% for dyslipidemia. CONCLUSIONS: In primary care, evaluating whether physicians respond appropriately to poor risk factor control, in addition to assessing proportions in control, provide a broader view of the quality of care than relying solely on measures of proportions in control. Such measures could be more clinically relevant and acceptable to physicians than simply reporting levels of control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis considers nondestructive optical methods for metal surface and subsurface inspection. The main purpose of this thesis was to study some optical methods in order to find out their applicability to industrial measurements. In laboratory testing the simplest light scattering approach, measurement of specular reflectance, was used for surface roughness evaluation. Surface roughness, curvature and finishing process of metal sheets were determined by specular reflectance measurements. Using a fixed angleof incidence, the specular reflectance method might be automated for industrialinspection. For defect detection holographic interferometry and thermography were compared. Using either holographic interferometry or thermography, relativelysmall-size defects in metal plates could be revealed. Holographic techniques have some limitations for industrial measurements. On the contrary, thermography has excellent prospects for on-line inspection, especially with scanning techniques.