906 resultados para Medicine in literature


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To determine the E. faecalis biofilm formation on the surface of five adhesive systems (AS) and its relationship with roughness. Study Design: The formation of E. faecalis biofilms was tested on the surface of four dual-cure AS: AdheSE DC, Clearfil DC Bond, Futurabond DC and Excite DSC and one light-cure antimicrobial AS, Clearfil Protect Bond, after 24 hours of incubation, using the MBEC high-throughput device. Results: E. faecalis biofilms grew on all the adhesives. The least growth of biofilm was on Excite DSC, Clearfil Protect Bond, and the control. Futurabond DC resulted in the greatest roughness and biofilm amount. There was a close relationship between the quantity of biofilm and roughness, except for Clearfil Protect Bond, which showed little biofilm but high roughness. Conclusion: None of the tested AS prevented E. faecalis biofilm formation, although the least quantity was found on the surface of Clearfil Protect Bond.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The application of immunobiologics for the rheumatoid arthritis treatment may present as a rare complication the development of inflammatory myopathy. Until this moment, there have been described in literature only seven cases of inhibitors of tumor necrosis factor induced-myositis. In this paper, we report the case of the patient with 39 years-old with eight years of arthritis rheumatoid and that due to refractory to various immunosuppressive drugs, the adalimumab was introduced, and evolved to dermatomyositis status.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Changepoint regression models have originally been developed in connection with applications in quality control, where a change from the in-control to the out-of-control state has to be detected based on the avaliable random observations. Up to now various changepoint models have been suggested for differents applications like reliability, econometrics or medicine. In many practical situations the covariate cannot be measured precisely and an alternative model are the errors in variable regression models. In this paper we study the regression model with errors in variables with changepoint from a Bayesian approach. From the simulation study we found that the proposed procedure produces estimates suitable for the changepoint and all other model parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Toxoplasmosis is usually a benign infection, except in the event of ocular, central nervous system (CNS), or congenital disease and particularly when the patient is immunocompromised. Treatment consists of drugs that frequently cause adverse effects; thus, newer, more effective drugs are needed. In this study, the possible activity of artesunate, a drug successfully being used for the treatment of malaria, on Toxoplasma gondii growth in cell culture is evaluated and compared with the action of drugs that are already being used against this parasite. Methods: LLC-MK2 cells were cultivated in RPMI medium, kept in disposable plastic bottles, and incubated at 36 degrees C with 5% CO2. Tachyzoites of the RH strain were used. The following drugs were tested: artesunate, cotrimoxazole, pentamidine, pyrimethamine, quinine, and trimethoprim. The effects of these drugs on tachyzoites and LLC-MK2 cells were analyzed using nonlinear regression analysis with Prism 3.0 software. Results: Artesunate showed a mean tachyzoite inhibitory concentration (IC50) of 0.075 mu M and an LLC MK2 toxicity of 2.003 mu M. Pyrimethamine was effective at an IC50 of 0.482 mu M and a toxicity of 11.178 mu M. Trimethoprim alone was effective against the in vitro parasite. Cotrimoxazole also was effective against the parasite but at higher concentrations than those observed for artesunate and pyrimethamine. Pentamidine and quinine had no inhibitory effect over tachyzoites. Conclusions: Artesunate is proven in vitro to be a useful alternative for the treatment of toxoplasmosis, implying a subsequent in vivo effect and suggesting the mechanism of this drug against the parasite.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatments (TS - external hexagon with acid surface treatment; and MS - external hexagon, machined surface), all 3.75 mm in diameter x 11.5 mm in length, were inserted into segments of artificial bones. The IT of each sample was measured by an electronic torquemeter, and then the pullout test was done with a universal testing machine. The results were subjected to ANOVA (p < 0.05), followed by Tukey's test (p < 0.05). The IT results showed no statistically significant difference, since the sizes of the implants used were very similar, and the bone used was not highly resistant. The PF values (N) were, respectively, TS = 403.75 +/- 189.80 and MS = 276.38 +/- 110.05. The implants were shown to be different in terms of the variables of maximum force (F = 4.401, p = 0.0120), elasticity in maximum flexion (F = 3.672, p = 0.024), and relative stiffness (F = 4.60, p = 0.01). In this study, external hexagonal implants with acid surface treatment showed the highest values of pullout strength and better stability, which provide greater indication for their use.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated the effect of titanium tetrafluoride (TiF4) formulations on enamel carious demineralization in situ. Thirteen subjects took part in this cross-over, split-mouth, double-blind study performed in three phases of 14 d each. In each subject, two sound and two predemineralized specimens of bovine enamel were worn intra-orally and plaque accumulation was allowed. One sound and one predemineralized specimen in each subject was treated once with sodium fluoride (NaF) varnish or solution (Treatment A); TiF4 varnish or solution (Treatment B); or placebo varnish or no treatment (Treatment C). The initially sound enamel specimens were exposed to severe cariogenic challenge (20% sucrose, eight times daily for 5 min each time), whereas the predemineralized specimens were not. Eleven subjects were able to finish all experimental phases. The enamel alterations were quantified by surface hardness and transversal microradiography. Demineralization of previously sound enamel was reduced by all test formulations except for the NaF solution, while both TiF4 formulations were as effective as NaF varnish. For the predemineralized specimens, enamel surface hardness was increased only by TiF4 formulations, while subsurface mineral remineralization could not be seen in any group. Within the experimental protocol, TiF4 was able to decrease enamel demineralization to a similar degree as NaF varnish under severe cariogenic challenges, while only TiF4 formulations remineralized the enamel surface.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to investigate the role of myoepithelial cell and tumor microenvironment in salivary gland neoplasma, we have performed a study towards the effect of different extracellular matrix proteins (basement membrane matrix, type I collagen and fibronectin) on morphology and differentiation of benign myoepithelial cells from pleomorphic adenoma cultured with malignant cell culture medium from squamous cell carcinoma. We have also analyzed the expression of alpha-smooth muscle actin (alpha-SMA) and FGF-2 by immunofluorescence and qPCR. Our immunofluorescence results, supported by qPCR analysis, demonstrated that alpha-SMA and FGF-2 were upregulated in the benign myoepithelial cells from pleomorphic adenoma in all studied conditions on fibronectin substratum. However, the myoepithelial cells on fibronectin substratum did not alter their morphology under malignant conditioned medium stimulation and exhibited a stellate morphology and, occasionally focal adhesions with the substratum. In summary, our data demonstrated that the extracellular matrix exerts an important role in the morphology of the benign myoepithelial cells by the presence of focal adhesions and also inducing increase FGF-2 and alpha-SMA expression by these cells, especially in the fibronectin substratum. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Paragangliomas are rare tumors origined on chromaffin-cells of neural crest and can be located from skull base to pelvis, on sympathetic or parasympathetic paraganglia. They account on less than 0,06% of all urinary bladder tumors, with only few hundreds of cases reported in literature since the first record by Zimmermmann in 1953. Case Report: A 63 year-old woman referring irritative urinary symptoms was submitted to an ultrassonography that disclosed an irregular-shaped nodulation on her bladder. CT confirmed the existence of a nodulation on bladder's anterior wall. Patient had normal levels of urinary catecholamins and Vanilmandelic acid. Tumor was excised and posterior immunohistochemical study revealed it was a paraganglioma. Nowadays, ten months after surgery, patient stills healthy and disease-free. Discussion: Paragangliomas can be classified as functionant or non-functionant, according to its production of cathecolamins, which can cause the same symptom complex of pheocromocytomas. About 10-15% of bladder paragangliomas are malignant, and potential metastasis are more common to lymph nodes, lungs and bones. 131-MIBG iodine cyntilography is the most sensitive method for diagnosis and surgery (transurethral resection or cystectomy) is the best choice for treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fabry disease (FD) is an X-linked inborn error of glycosphingolipid catabolism that results from mutations in the alpha-galactosidase A (GLA) gene. Evaluating the enzymatic activity in male individuals usually performs the diagnosis of the disease, but in female carriers the diagnosis based only on enzyme assays is often inconclusive. In this work, we analyzed 568 individuals from 102 families with suspect of FD. Overall, 51 families presented 38 alterations in the GLA gene, among which 19 were not previously reported in literature. The alterations included 17 missense mutations, 7 nonsense mutations, 7 deletions, 6 insertions and 1 in the splice site. Six alterations (R112C, R118C, R220X, R227X, R342Q and R356W) occurred at CpG dinucleotides. Five mutations not previously described in the literature (A156D, K237X, A292V, I317S, c.1177_1178insG) were correlated with low GLA enzyme activity and with prediction of molecular damages. From the 13 deletions and insertions, 7 occurred in exons 6 or 7 (54%) and 11 led to the formation of a stop codon. The present study highlights the detection of new genomic alterations in the GLA gene in the Brazilian population, facilitating the selection of patients for recombinant enzyme-replacement trials and offering the possibility to perform prenatal diagnosis. Journal of Human Genetics (2012) 57, 347-351; doi:10.1038/jhg.2012.32; published online 3 May 2012

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To evaluate the systemic blood pressure (BP) during daytime and nighttime in children with sleep breathing disorders (SBD) and compare parameters of BP in children with diagnosis of obstructive sleep apnea syndrome (OSA) to those one with primary snoring (PS). Methods: Children, both genders, aged from 8 to 12 years, with symptoms of SBD realized an overnight polysomnography followed by a 24 h recording of ambulatory BP. Results: All subjects presented with a history of snoring 7 nights per week. Children who have apnea/hipoapnea index >= four or a apnea index >= one presented a mean BP of 93 +/- 7 mmHg and 85 +/- 9 mmHg diurnal and nocturnal respectively whereas children who have a apnea/hipoapnea < four or a apnea index < one presented 90 +/- 7 mmHg and 77 +/- 2 mmHg. Eight children out of fourteen, from OSA group, lost the physiologic nocturnal dipping of the blood pressure. Among OSA children 57% were considered non-dippers. Two (16%) have presented absence of nocturnal dipping among children with primary snoring. The possibility of OSA children loosing physiologic blood pressure dipping was 6.66 higher than the possibilities of patients from PS group. Discussion: Our results indicate that children with sleep apnea syndrome exhibit a higher 24 h blood pressure when compared with those of primary snoring in form of decreased degree of nocturnal dipping and increased levels of diastolic and mean blood pressure, according to previous studies in literature. OSA in children seems to be associated to the development of hypertension or other cardiovascular disease. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Background Hydatidiform mole (HM) is characterized by abnormal proliferation of human trophoblast with producers functioning tissues of human chorionic gonadotropin. It can evolve with ovarian cysts tecaluteínicos, hypertension of pregnancy or hyperthyroidism. The incidence of HM is variable and its etiology poorly known, associated with nutritional factors, environmental, age, parity, history of HM, oral contraceptives, smoking, consanguinity or defects in germ cells. There is no reference in literature on HM resulting from sexual violence, objective of this report. Method Description of two cases of HM among 1146 patients with pregnancy resulting from sexual violence treated at Hospital Pérola Byington, São Paulo, from July 1994 to August 2011. Results The cases affected young, white, unmarried, low educated and low parity women. Sexual violence was perpetrated by known offenders unrelated to the victims, under death threat. Ultrasound and CT of the pelvis showed bulky uterus compatible with HM without myometrial invasion. One case was associated with theca lutein cysts. The two cases were diagnosed in the second trimester of pregnancy and evolved with hyperthyroidism. There was no hypertension, disease recurrence, metastasis or sexually transmitted infection. Conclusion The incidence of HM was 1:573 pregnancies resulting from rape, within the range estimated for Latin American countries. Trophoblastic material can be preserved to identify the violence perpetrator, considering only the paternal HM chromosomes. History of sexual violence should be investigated in cases of HM in the first half of adolescence and women in a vulnerable condition.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Background The objective of this study was to investigate the effects of the Brazilian Scaptotrigona sp propolis, a widely used folk medicine, in corneal wound healing and inflammation. Methods Corneal epithelial defects of 1 mm in diameter were made in the right eyes of Wistar male adult rats by cauterization with silver nitrate sticks. Subsequently, they were divided in two groups (n = 40 rats/group): Brazilian propolis (BP) group was topically treated with a microemulsion containing 1% Brazilian propolis; vehicle (VH) group received the same formulation without propolis. The epithelial defect area was photographed and measured at t = 0 (wound induction), and after 12, 24, 48 and 120 h of treatment. The inflammatory response was evaluated based on counting of neutrophils. Epithelial regeneration rates were determined based on Ki-67 expression in basal epithelial cells. Comparisons were made using the Kruskal-Wallis and the Mann–Whitney U test. Results The BP group presented both smaller epithelial defect areas at 12, 24 and 48 h and fewer corneal infiltrating neutrophils at 24 and 48 h (P < 0.01) than the VH group. These effects were associated with more pervasive Ki-67 staining in the BP group at 12 and 24 h (P < 0.05). Conclusions Topically applied BP accelerated wound healing and reduced the inflammatory response to silver nitrate-induced corneal alkali burns in rats.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction and Objectives: Vancomycin is indicated to patients who have not responded to treatment with other antibiotics in serious infections caused by organisms susceptible to it and resistant to other antimicrobials. However, over the last five years, many adverse reactions have been reported with this medicine in the University Hospital of the University of Silo Paulo (HU/USP), such as nephrotoxicity and toxicity related to infusion. Some critical patients, for example surgical patients with sepsis and severe trauma are generally susceptible to renal failure due to the severity of the underlying disease. The-aim of this study is to quantify and delineate the epidemiological profile of confirmed adverse reactions caused by vancomycin. Material and Methods: We conducted a retrospective observational quantitative study of medical records of patients who had confirmed.adverse reactions occurred with vancomycin in the period from January 2007 to May 2012, at the HU/USP - Brazil. All notifications related to vancomycin were evaluated in the following items: age and sex of patients, type and ward where the adverse event occurred involving this drug. Results and Conclusions: During the analysed period, were confinued 37 adverse events with vancomycn. The adults represented 75,7% of the cases, and the children 24,3%. The present study shows that adult patients admitted to the medical clinic had greater susceptibility to adverse reactions to vancomycin and for pediatric patients its higher frequency was at ICU. Despite the adverse skin reactions performed with greater frequency, it is known that the most severe reactions were related to the kidney resulting in more complex clinical interventions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.