874 resultados para Medical rationalities
Resumo:
Laser transmission joining (LTJ) is growing in importance, and has the potential to become a niche technique for the fabrication of hybrid plastic-metal joints for medical device applications. The possibility of directly joining plastics to metals by LTJ has been demonstrated by a number of recent studies. However, a reliable and quantitative method for defining the contact area between the plastic and metal, facilitating calculation of the mechanical shear stress of the hybrid joints, is still lacking. A new method, based on image analysis using ImageJ, is proposed here to quantify the contact area at the joint interface. The effect of discolouration on the mechanical performance of the hybrid joints is also reported for the first time. Biocompatible polyethylene terephthalate (PET) and commercially pure titanium (Ti) were selected as materials for laser joining using a 200 W CW fibre laser system. The effect of laser power, scanning speed and stand-off distance between the nozzle tip and top surface of the plastic were studied and analysed by Taguchi L9 orthogonal array and ANOVA respectively. The surface morphology, structure and elemental composition on the PET and Ti surfaces after shearing/peeling apart were characterized by SEM, EDX, XRD and XPS.
Resumo:
Currently, micro-joining of plastic parts to metal parts in medical devices is achieved by using medical adhesives, For example, pacemakers, defibrillators and neurological stimulators are designed using silicone adhesive to seal the joint between the polyurethane connector module and the titanium can [1]. Nevertheless, the use of adhesive is problematic because it requires a long time to cure and has high tendency to produce leachable products which might be harmful to the human body. An alternative for directly joining plastics to metal without adhesive is therefore required. Laser transmission joining (LTJ) is growing in importance, and has the potential to gain the niche in micro-fabrication of plastics-metal hybrid joints for medical device applications. The possibility of directly joining plastics to metal by LTJ technique have been demonstrated by a number of studies in recent literature [2]. The widely-accepted understanding of LTJ between plastics and metal is that generation and rapid expansion of micro-bubbles at the plastics-metal interface exert high local pressure to press the melted plastics towards the metal surface features during the laser processing [2]. This subsequently creates the plastics-metal hybrid joint by the mechanisms of mechanical interlocking as well as chemical and physical bonds between the plastics and metal surfaces. Although the micro-bubbles can help promote the mechanical interlocking effect to increase the joint strength, the creation of bubble is a random and complex process depending on the complicated interactions between the laser intensity, thermal degradation properties of plastics, surface temperature and topographical features of metal. In an ideal situation, it is desirable to create the hybrid plastics-metal joint without bubbles. However, the mechanical performance of the hybrid plastics-metal joint without bubbles is still unknown, and systematic comparison between the hybrid joints with and without bubbles is lacking in literature. This becomes the objective of this study. In this work, the laser process parameters were carefully chosen from a preliminary study, such that different hybrid joints: with and without bubbles can be produced and compared. Biocompatible PET and commercially pure Ti were selected as materials for laser joining.
Resumo:
The electronic storage of medical patient data is becoming a daily experience in most of the practices and hospitals worldwide. However, much of the data available is in free-form text, a convenient way of expressing concepts and events, but especially challenging if one wants to perform automatic searches, summarization or statistical analysis. Information Extraction can relieve some of these problems by offering a semantically informed interpretation and abstraction of the texts. MedInX, the Medical Information eXtraction system presented in this document, is the first information extraction system developed to process textual clinical discharge records written in Portuguese. The main goal of the system is to improve access to the information locked up in unstructured text, and, consequently, the efficiency of the health care process, by allowing faster and reliable access to quality information on health, for both patient and health professionals. MedInX components are based on Natural Language Processing principles, and provide several mechanisms to read, process and utilize external resources, such as terminologies and ontologies, in the process of automatic mapping of free text reports onto a structured representation. However, the flexible and scalable architecture of the system, also allowed its application to the task of Named Entity Recognition on a shared evaluation contest focused on Portuguese general domain free-form texts. The evaluation of the system on a set of authentic hospital discharge letters indicates that the system performs with 95% F-measure, on the task of entity recognition, and 95% precision on the task of relation extraction. Example applications, demonstrating the use of MedInX capabilities in real applications in the hospital setting, are also presented in this document. These applications were designed to answer common clinical problems related with the automatic coding of diagnoses and other health-related conditions described in the documents, according to the international classification systems ICD-9-CM and ICF. The automatic review of the content and completeness of the documents is an example of another developed application, denominated MedInX Clinical Audit system.
Resumo:
In Portugal, there is an old tradition in using clayey materials for therapeutic purposes. They are applied in pelotherapy, at several beaches of the Atlantic coast in the form of clay-sea water mixtures (peloids) to treat skin and rheumatic diseases. During many generations, peloids have been applied without scienti c studies that prove their therapeutic validity. In the last decade, the Portuguese scienti c community has become increasingly more interested in assessing the properties that make clayey materials suitable for therapeutic purposes. The abundance of clayey formations and the established practices of medical hydrology in our country turned this interest into a new perspective of application. The studied materials include di erent clays (in age and origin) mainly collected from well-known Mesozoic-Cenozoic formations, in some cases outcropping at beaches where empirical applications occur. This thesis focus in the study of silt-clay fraction (< 63 m).To determine their suitability for therapy, compositional, physicochemical, technological, thermal and rheological properties were assessed. Conventional techniques (XRD, XRF and Sedigraph) were used to assess compositional features of silt-clay fraction. Electron microscopy (SEM, VPSEM, HREM) was used to study the micromorphology and composition of clay fraction (< 2 m). Physicochemical properties (cation exchange and speci c surface) were assessed using the Ammonium Acetate and BET methods. Technological properties (plasticity and abrasivity indices) were assessed using the Atterberg limits and Einlehner abrasion tests. Thermal properties (speci c heat and cooling kinetics) were estimated by DSC analysis and cooling tests. Pharmacotechnical tests (compressibility index, sediment volume and Brook eld viscosity) were used to assess the powder owability as well as the physical stability and viscosity of clay-water dispersions. We selected as suitable Portuguese clays for health applications the samples A-Pe, A-Be2, A-Sd, J-Fr , M-To, C-Lu1, C-Lu2, Pl-Ba, M-Ga and J-Ab because they represent safe materials, with an adequate composition, good technological, physicochemical and thermal properties for application, also presenting an adequate rheology when dispersed in water. Their most relevant characteristics are the high clay minerals content, abundant smectite, illite and kaolinite, and safe hazardous concentrations. They also showed moderate capacity to exchange Ca 2+, high plasticity, low abrasivity, high speci c heat and slow cooling kinetics. They evidenced fair powder owability and good potential to formulate viscous dispersions when stabilized. Because the majority of the assessed characteristics are in accordance with those presented by clays applied in European spas for pelotherapy, we considered this group of clays also suitable for medical hydrology treatments in Portuguese spas.
Resumo:
This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.
Resumo:
Dissertação de mestrado, Engenharia Informática, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015
Resumo:
In this study, we utilise a novel approach to segment out the ventricular system in a series of high resolution T1-weighted MR images. We present a brain ventricles fast reconstruction method. The method is based on the processing of brain sections and establishing a fixed number of landmarks onto those sections to reconstruct the ventricles 3D surface. Automated landmark extraction is accomplished through the use of the self-organising network, the growing neural gas (GNG), which is able to topographically map the low dimensionality of the network to the high dimensionality of the contour manifold without requiring a priori knowledge of the input space structure. Moreover, our GNG landmark method is tolerant to noise and eliminates outliers. Our method accelerates the classical surface reconstruction and filtering processes. The proposed method offers higher accuracy compared to methods with similar efficiency as Voxel Grid.
Resumo:
Researchers want to analyse Health Care data which may requires large pools of compute and data resources. To have them they need access to Distributed Computing Infrastructures (DCI). To use them it requires expertise which researchers may not have. Workflows can hide infrastructures. There are many workflow systems but they are not interoperable. To learn a workflow system and create workflows in a workflow system may require significant effort. Considering these efforts it is not reasonable to expect that researchers will learn new workflow systems if they want to run workflows of other workflow systems. As a result, the lack of interoperability prevents workflow sharing and a vast amount of research efforts is wasted. The FP7 Sharing Interoperable Workflow for Large-Scale Scientific Simulation on Available DCIs (SHIWA) project developed the Coarse-Grained Interoperability (CGI) to enable workflow sharing. The project created the SHIWA Simulation Platform (SSP) to support CGI as a production-level service. The paper describes how the CGI approach can be used for analysis and simulation in Health Care.
Resumo:
Data registration refers to a series of techniques for matching or bringing similar objects or datasets together into alignment. These techniques enjoy widespread use in a diverse variety of applications, such as video coding, tracking, object and face detection and recognition, surveillance and satellite imaging, medical image analysis and structure from motion. Registration methods are as numerous as their manifold uses, from pixel level and block or feature based methods to Fourier domain methods. This book is focused on providing algorithms and image and video techniques for registration and quality performance metrics. The authors provide various assessment metrics for measuring registration quality alongside analyses of registration techniques, introducing and explaining both familiar and state–of–the–art registration methodologies used in a variety of targeted applications.