967 resultados para Measurement range
Resumo:
We present measurements and numerical simulation of a-Si:H p-i-n detectors with a wide range of intrinsic layer thickness between 2 and 10 pm. Such a large active layer thickness is required in applications like elementary particle detectors or X-ray detectors. For large thickness and depending on the applied bias, we observe a sharp peak in the spectral response in the red region near 700 nm. Simulation results obtained with the program ASCA are in agreement with the measurement and permit the explanation of the experimental data. In thick samples holes recombine or are trapped before reaching the contacts, and the conduction mechanism is fully electron dominated. As a consequence, the peak position in the spectral response is located near the optical band gap of the a-Si:H i-layer. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica na Área de Manutenção e Produção
Resumo:
O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.
Resumo:
Cada vez mais começa a notar-se, na indústria vitivinícola, uma grande preocupação com a qualidade dos seus produtos, motivada pela maior sensibilização e exigência dos consumidores. Deste modo, a presença de defeitos organoléticos no vinho representa uma fonte de perda financeira nesta indústria, pelo que o seu controlo se torna indispensável para que se obtenha um produto de elevada qualidade. Neste sentido, torna-se interessante desenvolver um método de análise que seja rápido de forma a permitir a quantificação simultânea das moléculas identificadas como principais responsáveis pelos distúrbios olfativos dos vinhos. Assim, este trabalho surge com o objetivo de implementar e validar um método para a determinação de contaminantes em vinho por microextração em fase sólida (SPME) e cromatografia gasosa acoplada à espetrometria de massa tandem (GC-MS/MS) e a sua correlação com a análise sensorial. A técnica de microextração em fase sólida é simples e rápida na medida em que não requer um pré-tratamento da amostra. Por sua vez, a análise por GC-MS permite identificar de forma clara os compostos em estudo, nomeadamente, 4-Etilfenol (4-EP), 4-Etilguaiacol (4-EG), 2,4,6-Tricloroanisol (TCA), 2,3,4,6-Tetracloroanisol (TeCA) e 2,4,6-Tribromoanisol (TBA). Foram realizados estudos de otimização das condições de extração, comparando as fibras 100 μm PDMS e 50/30 μm DVB/CAR/PDMS. Obtiveram-se resultados mais satisfatórios, em termos de resposta e da relação sinal/ruído, com a fibra 50/30 μm DVB/CAR/PDMS e estabeleceram-se como condições de extração 55ºC para a temperatura de incubação/extração, uma velocidade de agitação de 250 rpm e 60 minutos de tempo de extração. Ao longo deste trabalho, analisaram-se 50 amostras de vinho, das quais 48 eram amostras de Vinho Tinto do Douro e 2 de Vinho do Porto. Para validar a metodologia foram realizados estudos de linearidade, limiares analíticos, repetibilidade, precisão intermédia e recuperação. De um modo geral, obtiveram-se bons resultados ao nível da linearidade para as gamas de concentração escolhidas. Quanto aos limites de deteção e de quantificação, o 4-EP é o contaminante que apresenta uma gama de concentrações mais alta, notando-se limiares analíticos mais elevados, com valores próximos dos últimos níveis de concentração, oscilando entre 65 e 583 μg/L. No caso dos Anisóis, o TBA apresenta limites de deteção mais baixos, entre 0,4 e 17,0 ng/L. Os limiares analíticos foram validados com recurso a estudos de precisão intermédia e repetibilidade, cujos resultados se encontram dentro das especificações descritas no documento SANCO/10684/2009 (%RSD ≤ 30% para os Anisóis e %RSD ≤ 20% para os Fenóis Voláteis). Foram, ainda, realizados estudos de exatidão recorrendo a ensaios de recuperação e a ensaios interlaboratoriais. Muitas vezes conseguem-se boas recuperações, no entanto notam-se maiores dificuldades para o TBA e para o TeCA. Relativamente aos ensaios interlaboratoriais, verificam-se maiores discrepâncias para o 4-EP. Já os restantes contaminantes apresentam resultados, geralmente, satisfatórios (|z-score| ≤ 2).
Resumo:
Mestrado em Contabilidade
Resumo:
When a mixture is confined, one of the phases can condense out. This condensate, which is otherwise metastable in the bulk, is stabilized by the presence of surfaces. In a sphere-plane geometry, routinely used in atomic force microscope and surface force apparatus, it, can form a bridge connecting the surfaces. The pressure drop in the bridge gives rise to additional long-range attractive forces between them. By minimizing the free energy of a binary mixture we obtain the force-distance curves as well as the structural phase diagram of the configuration with the bridge. Numerical results predict a discontinuous transition between the states with and without the bridge and linear force-distance curves with hysteresis. We also show that similar phenomenon can be observed in a number of different systems, e.g., liquid crystals and polymer mixtures. (C). 2004 American Institute of Physics.
Resumo:
The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.
Resumo:
Purpose - To verify the results of a diaphragmatic breathing technique (DBT) on diaphragmatic range of motion in healthy subjects. Methods - A total of 51 healthy subjects (10 male; 41 female), mean age 20 years old and a body mass index (BMI) ranging from 15.6 to 34.9 kg/m2, were enrolled in this study. Diaphragmatic range of motion was assessed by M-mode ultrasound imaging. Measurements were made before and after the DBT implementation in a standard protocol, based on 3 seconds of inspiration starting from a maximum expiration. Differences between assessments were analyzed by descriptive statistics and t-test (p < 0.05). Results - Mean value range of motion before DBT was 55.3 ± 13.4 mm and after DBT was 63.8 ± 13.2 mm showing a significant improvement of 8.5 ± 14.7 mm (p < 0.001). A strong correlation between the slope and the range of motion was found (r = 0.71, p < 0.001). Conclusions - Based on ultrasound measurements, it has been proved that DBT really contributes to a higher diaphragmatic range of motion. Future studies are needed in order to understand the influence of protocol parameters (e.g. inspiration time). Clinical implications - In the contest of evidence-based practice in physiotherapy, it has been showed by objective measurements that DBT improves the diaphragm range of motion, translating into a more efficient ventilatory function and thus can be used in clinical setting. To our knowledge this is the first study to assess the effects of DBT on range of motion of diaphragm muscle with ultrasound imaging.
Resumo:
Objective: The purpose of this study was to investigate effects of different manual techniques on cervical ranges of 17 motion and pressure pain sensitivity in subjects with latent trigger point of the upper trapezius muscle. 18 Methods: One hundred seventeen volunteers, with a unilateral latent trigger point on upper trapezius due to computer 19 work, were randomly divided into 5 groups: ischemic compression (IC) group (n = 24); passive stretching group (n = 20 23); muscle energy technique group (n = 23); and 2 control groups, wait-and-see group (n = 25) and placebo group 21 (n = 22). Cervical spine range of movement was measured using a cervical range of motion instrument as well as 22 pressure pain sensitivity by means of an algometer and a visual analog scale. Outcomes were assessed pretreatment, 23 immediately, and 24 hours after the intervention and 1 week later by a blind researcher. A 4 × 5 mixed repeated- 24 measures analysis of variance was used to examine the effects of the intervention and Cohen d coefficient was used. 25 Results: A group-by-time interaction was detected in all variables (P b .01), except contralateral rotation. The 26 immediate effect sizes of the contralateral flexion, ipsilateral rotation, and pressure pain threshold were large for 3 27 experimental groups. Nevertheless, after 24 hours and 1 week, only IC group maintained the effect size. 28 Conclusions: Manual techniques on upper trapezius with latent trigger point seemed to improve the cervical range of 29 motion and the pressure pain sensitivity. These effects persist after 1 week in the IC group. (J Manipulative Physiol 301 Ther 2013;xx:1-10)
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Mestrado em Contabilidade
Resumo:
Objective - To define a checklist that can be used to assess the performance of a department and evaluate the implementation of quality management (QM) activities across departments or pathways in acute care hospitals. Design - We developed and tested a checklist for the assessment of QM activities at department level in a cross-sectional study using on-site visits by trained external auditors. Setting and Participants - A sample of 292 hospital departments of 74 acute care hospitals across seven European countries. In every hospital, four departments for the conditions: acute myocardial infarction (AMI), stroke, hip fracture and deliveries participated. Main outcome measures - Four measures of QM activities were evaluated at care pathway level focusing on specialized expertise and responsibility (SER), evidence-based organization of pathways (EBOP), patient safety strategies and clinical review (CR). Results - Participating departments attained mean values on the various scales between 1.2 and 3.7. The theoretical range was 0-4. Three of the four QM measures are identical for the four conditions, whereas one scale (EBOP) has condition-specific items. Correlations showed that every factor was related, but also distinct, and added to the overall picture of QM at pathway level. Conclusion - The newly developed checklist can be used across various types of departments and pathways in acute care hospitals like AMI, deliveries, stroke and hip fracture. The anticipated users of the checklist are internal (e.g. peers within the hospital and hospital executive board) and external auditors (e.g. healthcare inspectorate, professional or patient organizations).
Resumo:
The physiological responses of the clam R. decussatus from the Ria Formosa, southern Portugal, were examined in relation to normoxia, hypoxia (11, 6, 3 and 1.2 kPa) and anoxia; acute elevation of temperature (at 20, 27 and 32 °C), and its effect on the resistance to air exposure (at 20, 28 and 35 °C); current velocity (0.6, 3, 8 17, 24 and 36 cm. s-1) and turbidity (10, 100 and 300 mg. l-1 dry weight of particulate matter), and the efficiency of this species in retaining particles of different size (at 10 and 100 mg. l-1); and to copper contamination considering both short-term acute exposure to high levels (0.1-10 mg Cu. l-1) and chronic environmental levels (0.01 mg Cu. l-1). Clearance rates, respiration rates, absorption efficiency and excretion rates were assessed through the physiological energetics in terms of the energy budget and scope for growth (SFG). Stress independent respiration rates (R) and clearance rates (CR) were observed in relation to hypoxia down to 12 kPa and 6 kPa, respectively. Anoxic rates were 3.6 % of normoxic rates. Scope for growth was greatly reduced under extreme hypoxia (14 % of SFG in normoxia). Respiration rate was temperature independent in the range 20-32 °C but the decline in clearance rate resulted in negative SFG at 32 °C. Gaping during air exposure and the maintenance of faster aerobic metabolism led to 100 % mortality in 20 hours at 35 °C, 4 days at 28 °C and 5 days at 20 °C. Low current velocities (≤ 8 cm. s-1) supported high clearance rates. Shear stresses ≥ 0.9 Pa induced sediment movement and disturbed the feeding processes resulting in decreased clearance rates (at 36 cm. s-1, is 10 % of maximum CR). The observed ability of jetting out depleted water at a different level than the one of the inhalant current results is an important adaptation of clams to the slow currents of sheltered environments. Ingestion at high seston concentrations (> 100 mg. l-1) is controled by reducing the amount filtered, lowering CR (to 30 % of CR at low seston loads) and producing pseudofeces. Observed efficient retention of particles (70-100 %) in the range 3 to 8 μm is beneficial when algal cells are diluted by fine silt particles as it is likely to occur in the clams natural environment. R. decussatus in the short term escaped the exposure to copper by valve closure and therefore acute tests are not applicable to adult clams of this species. At environmental levels chronic exposure to copper did not induce lethal effects during the exposure period (20 days), but scope for growth was reduced to c. 30 %, indicating sustained impairment of physiological functions. The sensitivity of the physiological energetics and the integrated scope for growth measurement in assessing stress effects caused by natural environmental factors was highlighted.
Resumo:
Radio interference drastically affects the performance of sensor-net communications, leading to packet loss and reduced energy-efficiency. As an increasing number of wireless devices operates on the same ISM frequencies, there is a strong need for understanding and debugging the performance of existing sensornet protocols under interference. Doing so requires a low-cost flexible testbed infrastructure that allows the repeatable generation of a wide range of interference patterns. Unfortunately, to date, existing sensornet testbeds lack such capabilities, and do not permit to study easily the coexistence problems between devices sharing the same frequencies. This paper addresses the current lack of such an infrastructure by using off-the-shelf sensor motes to record and playback interference patterns as well as to generate customizable and repeat-able interference in real-time. We propose and develop JamLab: a low-cost infrastructure to augment existing sensornet testbeds with accurate interference generation while limiting the overhead to a simple upload of the appropriate software. We explain how we tackle the hardware limitations and get an accurate measurement and regeneration of interference, and we experimentally evaluate the accuracy of JamLab with respect to time, space, and intensity. We further use JamLab to characterize the impact of interference on sensornet MAC protocols.
Resumo:
Dalton Trans., 2003, 3328-3338