1000 resultados para Laser emissions
Resumo:
Lasers in pediatric dermatology were developed as a result of the treatment of port-wine stains. Infantile hemangiomas may benefit, in some cases, from laser treatment as well as venous and lymphatic malformations. For certain pigmented lesions, as well as some hamartomas, laser treatments are a credible alternative to surgical resection. Bum scars are improved by lasers which stimulate collagen remodeling. Furthermore, hair removal of congenital and acquired hypertrichosis can relieve psychosocial discomfort and improve quality of life. The management of pain and fear of children undergoing laser treatment, using either topical or general anesthesia, remains of central importance.
Resumo:
BACKGROUND: Port-wine stains (PWS) are malformations of capillaries in 0.3% of newborn children. The treatment of choice is by pulsed dye LASER (PDL), and requires several sessions. The efficacy of this treatment is at present evaluated on the basis of clinical inspection and of digital photographs taken throughout the treatment. LASER-Doppler imaging (LDI) is a noninvasive method of imaging the perfusion of the tissues by the microcirculatory system (capillaries). The aim of this paper is to demonstrate that LDI allows a quantitative, numerical evaluation of the efficacy of the PDL treatment of PWS. METHOD: The PDL sessions were organized according to the usual scheme, every other month, from September 1, 2012, to September 30, 2013. LDI imaging was performed at the start and at the conclusion of the PDL treatment, and simultaneously on healthy skin in order to obtain reference values. The results evidenced by LDI were analyzed according to the "Wilcoxon signed-rank" test before and after each session, and in the intervals between the three PDL treatment sessions. RESULTS: Our prospective study is based on 20 new children. On average, the vascularization of the PWS was reduced by 56% after three laser sessions. Compared with healthy skin, initial vascularization of PWS was 62% higher than that of healthy skin at the start of treatment, and 6% higher after three sessions. During the 2 months between two sessions, vascularization of the capillary network increased by 27%. CONCLUSION: This study shows that LDI can demonstrate and measure the efficacy of PDL treatment of PWS in children. The figures obtained when measuring the results by LDI corroborate the clinical assessments and may allow us to refine, and perhaps even modify, our present use of PDL and thus improve the efficacy of the treatment.
Resumo:
Tässä insinöörityössä otettiin käyttöön VTI Technologies Oy:lle hankittu laser Doppler - vibrometri, joka mittaa tärinää perustuen valon Dopplerin siirtymään. Työn tavoitteena oli perehtyä mittauslaitteistoon, muodostaa sille näytteenottolaitteisto ja käytännössä arvioida sen kyvykkyyttä mitata tärinää ja tuottaa uutta informaatiota. Työn teoreettisessa osuudessa perehdytään laser Doppler -vibrometrin teknologiaan ja toimintaperiaatteeseen sekä värähtelevien systeemien dynamiikkaan ja mallintamiseen. Työn käytännön osuuden suorittamiseksi perehdyttiin myös tärinätestauslaitteiston toimintaan, analogiasignaalin näytteenottoon sekä diskreettiin Fourier-muunnokseen perustuvaan signaalin spektrianalyysiin. Työssä käsitellään myös laser-mittauksen kohinalähteitä ja spektrianalyysin virhelähteitä. Työn käytännön osuudessa ohjelmoitiin Labview-mittausohjelmisto näytteenottolaitteistolle. Mittausohjelmistolla voidaan näytteistää vibrometrin mittaussignaalia ja muodostaa sen taajuusspektri. Mittauskohteita tässä työssä olivat kulmakiihtyvyystäryttimen mekaanisen liikkeen mittaus ja elementtikiekkosahan terän värähtelyjen mittaus. Mittaustulokset kulmakiihtyvyystäryttimestä osoittivat sen mekaanisen liikkeen säröytyvän voimakkaasti, johtuen todennäköisesti sen testialustan rakenteesta. Testialustan rakennetta tullaan kehittämään ja mittaukset toistetaan. Mittaustuloksiin elementtikiekkosahasta tuli suhtautua epäillen, koska mittaussignaalin intensiteetti oli erittäin heikko. Mittausten onnistuminen Laser Doppler -vibrometrillä edellyttää riittävää mittauskohteesta takaisinheijastuneen laser-valon intensiteettiä. Mittaustulokset osoittivat laser Doppler -vibrometrin olevan hyödyllinen työkalu tutkivassa tärinämittauksessa. Mittauskohteet, joiden pinta heijastaa huonosti valoa ja joihin ei voi asentaa erityistä heijastavaa teippiä, ovat kuitenkin haaste ja asettavat rajoituksen laser Doppler -vibrometrin käyttömahdollisuuksille. Tämän työn mittaustuloksia voidaan käyttää kulmakiihtyvyystäryttimen uusintamittausten vertailukohtana, kun arvioidaan kehitystyön onnistumista. Tätä työtä voidaan käyttää myös laser Doppler -vibrometrin ohjekirjana tärinämittauksissa.
Resumo:
Bi1.5Zn1Nb1.5O7 (BZN) epitaxial thin films were grown by pulsed laser deposition on Al2O3 with a double ZnO buffer layer through domain matching epitaxy (DME) mechanism. The pole figure analysis and reciprocal space mapping revealed the single crystalline nature of the thin film. The pole figure analysis also shows a 60º twinning for the (222) oriented crystals. Sharp intense spots in the SAED pattern also indicate the high crystalline nature of BZN thin film. The Fourier filtered HRTEM images of the BZN-ZnO interface confirms the domain matched epitaxy of BZN with ZnO buffer. An electric field dependent dielectric tunability of 68% was obtained for the BZN thin films with inter digital capacitors patterned over the film.
Resumo:
Fetoscopic coagulation of placental anastomoses is the treatment of choice for severe twin-to-twin transfusion syndrome. In the present day, fetal laser therapy is also used to treat amniotic bands, chorioangiomas, sacrococcygeal teratomas, lower urinary tract obstructions and chest masses, all of which will be reviewed in this article. Amniotic band syndrome can cause limb amputation by impairing downstream blood flow. Large chorioangiomas (>4 cm), sacrococcygeal teratomas or fetal hyperechoic lung lesions can lead to fetal compromise and hydrops by vascular steal phenomenon or compression. Renal damage, bladder dysfunction and lastly death because of pulmonary hypolasia may be the result of megacystis caused by a posterior urethral valve. The prognosis of these pathologies can be dismal, and therapy options are limited, which has brought fetal laser therapy to the forefront. Management options discussed here are laser release of amniotic bands, laser coagulation of the placental or fetal tumor feeding vessels and laser therapy by fetal cystoscopy. This review, largely based on case reports, does not intend to provide a level of evidence supporting laser therapy over other treatment options. Centralized evaluation by specialists using strict selection criteria and long-term follow-up of these rare cases are now needed to prove the value of endoscopic or ultrasound-guided laser therapy.
Resumo:
Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue
Resumo:
A termoablação por raio laser de tumores hepáticos tem despontado como alternativa válida de tratamento em pacientes que não são candidatos a ressecção cirúrgica. O procedimento pode ser realizado por via percutânea, laparoscópica ou por laparotomia, e orientado por métodos de imagem. O objetivo deste trabalho é apresentar o mecanismo de ação deste método, bem como as suas indicações, contra-indicações, complicações e resultados clínicos, baseados em revisão bibliográfica.
Resumo:
We present a detailed study on the morphology and magnetic properties of Co nanostructures deposited onto oxidized Si substrates by femtosecond pulsed laser deposition. Generally, Co disks of nanometric dimensions are obtained just above the ablation threshold, with a size distribution characterized by an increasingly larger number of disks as their size diminishes, and with a maximum disk size that depends on the laser power density. In Au/Co/Au structures, in-plane magnetic anisotropy is observed in all cases, with no indication of superparamagnetism regardless of the amount of material or the laser power density. Magnetic force microscopy observations show coexistence of single-domain and vortex states for the magnetic domain structure of the disks. Superconducting quantum interference device magnetometry and x-ray magnetic circular dichroism measurements point to saturation magnetization values lower than the bulk, probably due to partial oxidation of the Co resulting from incomplete coverage by the Au capping layer.
Resumo:
The CO2-laser-MAG hybrid welding process has been shown to be a productive choice for the welding industry, being used in e.g. the shipbuilding, pipe and beam manufacturing, and automotive industries. It provides an opportunity to increase the productivity of welding of joints containing air gaps compared with autogenous laser beam welding, with associated reductions in distortion and marked increases in welding speeds and penetration in comparison with both arc and autogenous laser welding. The literature study indicated that the phenomena of laser hybrid welding are mostly being studied using bead-on-plate welding or zero air gap configurations. This study shows it very clearly that the CO2 laser-MAG hybrid welding process is completely different, when there is a groove with an air gap. As in case of industrial use it is excepted that welding is performed for non-zero grooves, this study is of great importance for industrial applications. The results of this study indicate that by using a 6 kW CO2 laser-MAG hybrid welding process, the welding speed may also be increased if an air gap is present in the joint. Experimental trials indicated that the welding speed may be increased by 30-82% when compared with bead-on-plate welding, or welding of a joint with no air gap i.e. a joint prepared as optimum for autogenous laser welding. This study demonstrates very clearly, that the separation of the different processes, as well as the relative configurations of the processes (arc leading or trailing) affect welding performance significantly. These matters influence the droplet size and therefore the metal transfer mode, which in turn determined the resulting weld quality and the ability to bridge air gaps. Welding in bead-onplate mode, or of an I butt joint containing no air gap joint is facilitated by using a leading torch. This is due to the preheating effect of the arc, which increases the absorptivity of the work piece to the laser beam, enabling greater penetration and the use of higher welding speeds. With an air gap present, air gap bridging is more effectively achieved by using a trailing torch because of the lower arc power needed, the wider arc, and the movement of droplets predominantly towards the joint edges. The experiments showed, that the mode of metal transfer has a marked effect on gap bridgeability. Transfer of a single droplet per arc pulse may not be desirable if an air gap is present, because most of the droplets are directed towards the middle of the joint where no base material is present. In such cases, undercut is observed. Pulsed globular and rotational metal transfer modes enable molten metal to also be transferred to the joint edges, and are therefore superior metal transfer modes when bridging air gaps. It was also found very obvious, that process separation is an important factor in gap bridgeability. If process separation is too large, the resulting weld often exhibits sagging, or no weld may be formed at all as a result of the reduced interaction between the component processes. In contrast, if the processes are too close to one another, the processing region contains excess molten metal that may create difficulties for the keyhole to remain open. When the distance is optimised - i.e. a separation of 0-4 mm in this study, depending on the welding speed and beam-arc configuration - the processes act together, creating beneficial synergistic effects. The optimum process separation when using a trailing torch was found to be shorter (0-2 mm) than when a leading torch is used (2-4 mm); a result of the facilitation of weld pool motion when the latter configuration is adopted. This study demonstrates, that the MAG process used has a strong effect on the CO2-laser-MAG hybrid welding process. The laser beam welding component is relatively stable and easy to manage, with only two principal processing parameters (power and welding speed) needing to be adjusted. In contrast, the MAG process has a large number of processing parameters to optimise, all of which play an important role in the interaction between the laser beam and the arc. The parameters used for traditional MAG welding are often not optimal in achieving the most appropriate mode of metal transfer, and weld quality in laser hybrid welding, and must be optimised if the full range of benefits provided by hybrid welding are to be realised.
Resumo:
OBJETIVO: Verificar se o uso do laser de InGaAlP com comprimento de onda de 685 nm pode reduzir a incidência de xerostomia, gravidade da mucosite oral e da dor associada à mucosite em pacientes portadores de câncer de cabeça e pescoço submetidos a radioterapia. MATERIAIS E MÉTODOS: Sessenta pacientes portadores de carcinoma de cabeça e pescoço foram submetidos a radioterapia com dose diária de 1,8 a 2,0 Gy e dose final de 45 a 72 Gy. O volume salivar foi medido nos dias um, 15, ao final do tratamento e após 15 e 30 dias, e a mucosite oral em avaliações semanais. Vinte e nove pacientes se submeteram a radioterapia sem laser e 31 foram submetidos a radioterapia e laser com dose diária de 2 joules/cm² em pontos pré-determinados da mucosa oral e glândulas parótida e submandibular. RESULTADOS: No grupo submetido a radioterapia e laser, a incidência de mucosite (p < 0,001) e dor (p < 0,016) foram significativamente menores e o volume salivar se manteve maior (p < 0,001) durante e após o tratamento. CONCLUSÃO: Os pacientes submetidos à associação de radioterapia e laser tiveram menor incidência de xerostomia, mucosite oral e dor quando comparados ao grupo de radioterapia sem laser, com resultados com significância estatística.
Resumo:
In this study we use historical emission data from installations under the European Union Emissions Trading System, -EU ETS- to evaluate the impact of this policy on industrial greenhouse gas emissions during the first two trading phases, 2005-2012. As such the analysis seeks to disentangle two causes of emission abatement: that attributable to the EU ETS and that attributable to the economic crisis that hit the EU in 2008/09. Using a panel data approach the estimated emissions reduction attributable to the EU ETS is about 21 per cent of the total emission abatement during the observation period. These results suggest therefore that the lion’s share of abatement was attributable to the effects of the economic crisis, a finding that has serious implications for future policy adjustments affecting core elements of the EU ETS, including the distribution of EU emission allowances.
Resumo:
Typically, conflicts in world environmental negotiations are related, amongst other aspects, to the level of polarization of the countries in groups with conflicting interests. Given the predictable relationship between polarization and conflict, it would seem logical to evaluate the degree to which the distribution of countries – for example, in terms of their CO2 emissions per capita – would be structured through groups which in themselves are antagonistic, as well as their evolution over time. This paper takes the concept of polarization to explore this distribution for the period 1992-2010, looking at different analytic approaches related to the concept. Specifically, it makes a comparative evaluation of the results associated with endogenous multi-polarization measures (i.e. EGR and DER indices), exogenous measures (i.e. Z-K or multidimensional index) and strict bipolarization measures (i.e. Wolfson’s measure). Indeed, the interest lies not only in evaluating the global situation of polarization by comparing the different approaches and their temporal patterns, but also in examining the explanatory capacity of the different proxy groups used as a possible reference for designing global environmental policy from a group premise. JEL codes: D39; Q43; Q56. Key words: polarization; carbon emissions; conflict;
Resumo:
The possibility of printing two-dimensional micropatterns of biomolecule solutions is of great interest in many fields of research in biomedicine, from cell-growth and development studies to the investigation of the mechanisms of communication between cells. Although laser-induced forward transfer (LIFT) has been extensively used to print micrometric droplets of biological solutions, the fabrication of complex patterns depends on the feasibility of the technique to print micron-sized lines of aqueous solutions. In this study we investigate such a possibility through the analysis of the influence of droplet spacing of a water and glycerol solution on the morphology of the features printed by LIFT. We prove that it is indeed possible to print long and uniform continuous lines by controlling the overlap between adjacent droplets. We show how, depending on droplet spacing, several printed morphologies are generated, and we offer, in addition, a simple explanation of the observed behavior based on the jetting dynamics characteristic of the LIFT of liquids.