938 resultados para Implant-supported prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first case of Corynebacterium bovis shoulder prosthetic joint infection. The organism was isolated from intraoperative tissue culture and from the removed prosthesis using sonication. A 2-stage exchange and 3 months of antibiotic therapy were performed. C. bovis may cause implant-associated infections, which can manifest as low-grade infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book, published jointly by the American Society of Agronomy, Soil Science Society of American and Iowa State University presents the papers that were given at a symposium held in Ames, Iowa, on Nov. 30 and Dec. 1, 1965 on the general topic of plant environment and efficient water use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To study the efficacy and safety of a new intravitreal implant (sustained release of dexamethasone, Ozurdex®) recently approved in Switzerland for the treatment of macular edema secondary to retinal vein occlusion in a clinical setting.Patients and Methods: Prospective non-consecutive study of patients with macular edema secondary to central retinal vein occlusion or branch retinal vein occlusion treated with implant of dexamethasone 0.7 mg. Follow-up visits were performed at day 1, week 1 and monthly thereafter. ETDRS best corrected visual acuity, Goldmann tonometry and macular thickness on SD-OCT were registered. Retreatment was carried out on a pro re nata basis starting from month 3.Results: Fifteen eyes of 15 patients were included (8 branch retinal vein occlusions, 7 central retinal vein occlusions). 33 % of the patients achieved 3 lines or more of vision gain. The central retinal vein occlusion subgroup showed a mean decline in visual acuity at month 3. A reduction of 36 % of macular edema was already observed at day 1. All maculae were dry at month 1. The mean time of recurrence of macular edema for both groups was 4.6 months. A similar reduction of macular edema was obtained after a second implantation. An intraocular pressure increase of ≥ 20 % was observed after the first implantation in 53 % of patients.Conclusion: Our study showed efficacy and safety of intravitreal dexamethasone implant in the treatment of macular edema due to retinal vein occlusion. Anatomical efficacy was observed at day 1 but seems to have shorter effect than previously published data. No serious side effects were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) remains the preferred treatment for patients with invalidating osteoarthritis. It allows these patients to find once again a satisfactory quality of life. These results are reflected by the increasing number of interventions performed each year and in always younger patients. The objective of this review of the scientific literature was to determine the long-term quantitatively and qualitatively results of TKA and determine the parameters which could influence the long-term outcome. There does not seem to be any clear arguments in favor of one type of implant or surgical technique. One also notices that TKA in females and older patients seem to have longer lifespan, estimated to approximately 15 years. The most frequent complication remains aseptic loosening followed by infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHESE : BUT : Le but de ce sujet de recherche est d'évaluer le taux de succès et les complications à long terme de la sclérectomie profonde non pénétrante avec implant de collagène (SPIC) chez les patients atteints de glaucome à angle ouvert. METODES ET PATIENTS : Il s'agit d'une étude clinique, prospective, monocentrique, non-randomisée, effectuée sur 105 patients atteints d'un glaucome à angle ouvert médicalement non-contrôlé. Ces patients ont tous bénéficiés d'une SPIC, effectuée selon le geste chirurgicale standard (technique décrite dans l'article). Dans le cadre de cette étude, nous avons effectué un bilan ophtalmologique complet avant l'acte chirurgical puis un suivi postopératoire à 1 et 7 jours ; 1,2,3,6,9,12 mois et ensuite tous les 6 mois durant les dix années suivantes. RESULTATS : Le suivit moyen de cette étude s'étend sur 101.5 ± 43.1, [3-144] mois (moyenne ± écart type, [étendue]). La pression intraoculaire (PIO) préopératoire était élevée à 26.8 ± 7.7, (14-52] mmHg, et l'acuité visuelle corrigée à 0.71 ± 0.33, [0.02-1.5]. Au terme des dix années après le traitement chirurgical, le nombre de patients suivit était de 52 avec une pression intraoculaire abaissée à 12.2 ± 4.7, [6-20] mmHg et une acuité visuelle corrigée de 0.63 ± 0.34, [0.01-1.2]. Le nombre de médicaments par patient a diminué de 2.3 ± 0.7, [ 1-4] à 1.3 ± 1.1, [0-3]. Dix ans après la SPIC, une pression intraoculaire <_ 21 mmHg sans médicaments (succès complet) était obtenue chez 47.7 % des patients et 89 % avec ou sans traitement médicamenteux (succès relatif). Les gestes postopératoires additionnels par gonioponcture ont été effectués sur 61 yeux (59.8%) et les injections sous-conjonctival de 5-fluorouracil ont été pratiquées sur 25 yeux dont 5 incluant un needling. CONCLUSIONS : Le suivit à long terme sur une période de dix ans, démontre que la sclérectomie profonde avec implant de collagène (SPIC) est efficace dans le contrôle de la pression intraoculaire et présente peu de complications postopératoires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Controversy still exists as to the best surgical treatment for periprosthetic shoulder infections. The aim of this multi-institutional study was to review a continuous retrospective series of patients treated in four European centres and to assess the respective eradication rate of various treatment approaches. METHODS: Forty-four patients were available for this retrospective follow-up evaluation. Functional and clinical evaluation of treatment for infection was performed using the Constant-Murley score, visual analogue scale and patient satisfaction Neer score. Erythrocyte sedimentation rate, serum leucocyte count and C-reactive protein were measured and shoulder X-ray examination performed prior to surgery and at the latest follow-up. RESULTS: At a mean follow-up of 41 months (range 24-98), 42 of 44 patients (95.5%) showed no signs of infection recurrence/persistence. Comparable eradication rates were observed after resection arthroplasty (100%; 6/6), two-stage revision (17/17) or permanent antibiotic-loaded spacer implant (93.3%; 14/15). No patient was treated by one-stage revision. On average, both functional and pain scores improved significantly; the worst joint function was observed after resection arthroplasty. CONCLUSIONS: This retrospective analysis conducted on the largest published series of patients to date shows comparable infection eradication rates after two-stage revision, resection arthroplasty or permanent spacer implant for the treatment of septic shoulder prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prescribing of antibiotics for uncomplicated skin abscesses and diverticulitis has no benefit. Some antibiotics are more at risk of causing a Clostridium difficile infection. The tests used to exclude a history of a penicillin allergy are safe. A threshold of D-dimer adjusted for the age significantly improves the specificity of the test without affecting the sensitivity. The prescription of paraclinics tests is not an effective "treatment" for the patient's anxiety. In the sleep apnea syndrome, treatment with CPAP (Continuous positive airway pressure) appears to have more benefits compared to the mandibular advancement prosthesis. The work of primary care physicians can be supported by the work of advanced practice nurses. The limitation placed on the working hours of doctors in hospitals seems to affect their ability to spend time with their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several recently developed therapies targeting motor disabilities in stroke sufferers have shown to be more effective than standard neurorehabilitation approaches. In this context, several basic studies demonstrated that music training produces rapid neuroplastic changes in motor-related brain areas. Music-supported therapy has been recently developed as a new motor rehabilitation intervention. METHODS AND RESULTS: In order to explore the plasticity effects of music-supported therapy, this therapeutic intervention was applied to twenty chronic stroke patients. Before and after the music-supported therapy, transcranial magnetic stimulation was applied for the assessment of excitability changes in the motor cortex and a 3D movement analyzer was used for the assessment of motor performance parameters such as velocity, acceleration and smoothness in a set of diadochokinetic movement tasks. Our results suggest that the music-supported therapy produces changes in cortical plasticity leading the improvement of the subjects' motor performance. CONCLUSION: Our findings represent the first evidence of the neurophysiological changes induced by this therapy in chronic stroke patients, and their link with the amelioration of motor performance. Further studies are needed to confirm our observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A periprosthetic fracture is a fracture around or in proximity of a prosthetic implant. As more and more prostheses are implanted, the incidence of periprosthetic fractures also increases. Several risk factors have been outlined, some due to the patient, and some due to the implant itself. Key points in diagnosis are the case history and the imaging, as they allow the distinction between a well-fixed and a loose prosthesis. Correct classification is crucial for the treatment choice, which can be non-operative or consist in an osteosynthesis or in a revision arthroplasty, depending on the patient's general medical condition and the local status.