981 resultados para Diagnostic errors
Resumo:
Background: We have recently shown that the median diagnostic delay to establish Crohn's disease (CD) diagnosis in the Swiss IBD Cohort (SIBDC) was 9 months. Seventy five percent of all CD patients were diagnosed within 24 months. The clinical impact of a long diagnostic delay on the natural history of CD is unknown. Aim: To compare the frequency and type of CD-related complications in the patient groups with long diagnostic delay (>24 months) vs. the ones diagnosed within 24 months. Methods: Retrospective analysis of data from the SIBDCS, comprising a large sample of CD patients followed in hospitals and private practices across Switzerland. Results: Two hundred CD patients (121 female, mean age 44.9 ± 15.0 years, 38% smokers, 71% ever treated with immunomodulators and 35% with anti-TNF) with long diagnostic delay were compared to 697 CD patients (358 female, mean age 39.1 ± 14.9 years, 33% smokers, 74% ever treated with immunomodulators and 33% with anti-TNF) diagnosed within 24 months. No differences in the outcomes were observed between the two patient groups within year one after CD diagnosis. Among those diagnosed 2-5 years ago, CD patients with long diagnostic delay (n = 45) presented more frequently with internal fistulas (11.1% vs. 3.1%, p = 0.03) and bowel stenoses (28.9% vs. 15.7%, p = 0.05), and they more frequently underwent CD-related operations (15.6% vs. 5.0%, p = 0.02) compared to the patients diagnosed within 24 months (n = 159). Among those diagnosed 6-10 years ago, CD patients with long diagnostic delay (n = 48) presented more frequently with extraintestinal manifestations (60.4% vs. 34.6%, p = 0.001) than those diagnosed within 24 months (n = 182). For the patients diagnosed 11-15 years ago, no differences in outcomes were found between the long diagnostic delay group (n = 106) and the one diagnosed within 24 months (n = 32). Among those diagnosed >= 16 years ago, the group with long diagnostic delay (n = 71) more frequently underwent CD-related operations (63.4% vs. 46.5%, p = 0.01) compared to the group diagnosed with CD within 24 months (n = 241). Conclusions: A long diagnostic delay in CD patients is associated with a more complicated disease course and higher number of CD-related operations in the years following the diagnosis. Our results indicate that efforts should be undertaken to shorten the diagnostic delay in CD patients in order to reduce the risk for progression towards a complicated disease phenotype.
L'analyse des aglycones des glycosides de l'if comme outil diagnostic d'une intoxication à l'if (P9)
Resumo:
Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.
Resumo:
The semi-structured diagnostic interview for genetic studies (DIGS) was developed to assess major mood and psychotic disorders and their spectrum manifestations in genetic studies. Our research group developed a French version of the DIGS and tested its inter-rater and test-retest reliability in psychiatric patients. In this article, we present estimates of the reliability of substance use and antisocial personality disorders. High kappa coefficients for inter-rater reliability were found for drug and alcohol as well as antisocial personality diagnoses and slightly lower kappas for test-retest reliability. Combined with evidence of the reliability of major mood and psychotic disorders, these findings support the suitability of the DIGS for studies of familial aggregation and comorbidity of psychiatric disorders including substance use and antisocial personality disorders.
Resumo:
This article reports on a lossless data hiding scheme for digital images where the data hiding capacity is either determined by minimum acceptable subjective quality or by the demanded capacity. In the proposed method data is hidden within the image prediction errors, where the most well-known prediction algorithms such as the median edge detector (MED), gradient adjacent prediction (GAP) and Jiang prediction are tested for this purpose. In this method, first the histogram of the prediction errors of images are computed and then based on the required capacity or desired image quality, the prediction error values of frequencies larger than this capacity are shifted. The empty space created by such a shift is used for embedding the data. Experimental results show distinct superiority of the image prediction error histogram over the conventional image histogram itself, due to much narrower spectrum of the former over the latter. We have also devised an adaptive method for hiding data, where subjective quality is traded for data hiding capacity. Here the positive and negative error values are chosen such that the sum of their frequencies on the histogram is just above the given capacity or above a certain quality.
Resumo:
ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.
Resumo:
In a system where tens of thousands of words are made up of a limited number of phonemes, many words are bound to sound alike. This similarity of the words in the lexicon as characterized by phonological neighbourhood density (PhND) has been shown to affect speed and accuracy of word comprehension and production. Whereas there is a consensus about the interfering nature of neighbourhood effects in comprehension, the language production literature offers a more contradictory picture with mainly facilitatory but also interfering effects reported on word production. Here we report both of these two types of effects in the same study. Multiple regression mixed models analyses were conducted on PhND effects on errors produced in a naming task by a group of 21 participants with aphasia. These participants produced more formal errors (interfering effect) for words in dense phonological neighbourhoods, but produced fewer nonwords and semantic errors (a facilitatory effect) with increasing density. In order to investigate the nature of these opposite effects of PhND, we further analysed a subset of formal errors and nonword errors by distinguishing errors differing on a single phoneme from the target (corresponding to the definition of phonological neighbours) from those differing on two or more phonemes. This analysis confirmed that only formal errors that were phonological neighbours of the target increased in dense neighbourhoods, while all other errors decreased. Based on additional observations favouring a lexical origin of these formal errors (they exceeded the probability of producing a real-word error by chance, were of a higher frequency, and preserved the grammatical category of the targets), we suggest that the interfering effect of PhND is due to competition between lexical neighbours and target words in dense neighbourhoods.
Resumo:
The purpose of this bachelor's thesis was to chart scientific research articles to present contributing factors to medication errors done by nurses in a hospital setting, and introduce methods to prevent medication errors. Additionally, international and Finnish research was combined and findings were reflected in relation to the Finnish health care system. Literature review was conducted out of 23 scientific articles. Data was searched systematically from CINAHL, MEDIC and MEDLINE databases, and also manually. Literature was analysed and the findings combined using inductive content analysis. Findings revealed that both organisational and individual factors contributed to medication errors. High workload, communication breakdowns, unsuitable working environment, distractions and interruptions, and similar medication products were identified as organisational factors. Individual factors included nurses' inability to follow protocol, inadequate knowledge of medications and personal qualities of the nurse. Developing and improving the physical environment, error reporting, and medication management protocols were emphasised as methods to prevent medication errors. Investing to the staff's competence and well-being was also identified as a prevention method. The number of Finnish articles was small, and therefore the applicability of the findings to Finland is difficult to assess. However, the findings seem to fit to the Finnish health care system relatively well. Further research is needed to identify those factors that contribute to medication errors in Finland. This is a necessity for the development of methods to prevent medication errors that fit in to the Finnish health care system.
Resumo:
Remote diagnostics has become very popular in marine industry. Diagnostic systems are improved all the time and the newest monitoring systems are constantly taken into operation. Most vessels are, however, rigged up by outmoded facilities, which should be updated. In this work the principles of operating of such a remote diagnostic system as the ABB's third generation remote diagnostic system (RDS) and the newest Propulsion Condition Management System (PCMS) are studied. As a result of the thesis the ways of upgrading the old systems of RDS are presented. Specifically, the work focuses on the establishment of the connection between Advant controller AC-110 from the old system and PCMS server, and in other words how to get Modbus data by OPC server.
Resumo:
Miliary tuberculosis is a rare disease that is difficult to diagnose because of its non-specific presentation. It should be suspected in elderly patients who complaint of failure to thrive, unexplained fatigue and weight loss. Using a clinical situation where the diagnosis was made only at autopsy, we briefly review the epidemiology of miliary tuberculosis and propose recommendations for the diagnosis and the prophylaxis of latent tuberculosis. Finally, we discuss criteria to perform epidemiological investigations among close contacts in this situation.
Resumo:
Given the low sensitivity of amoebal coculture, we developed a specific real-time PCR for the detection of Parachlamydia. The analytical sensitivity was high, and the inter- and intrarun variabilities were low. When the PCR was applied to nasopharyngeal aspirates, it was positive for six patients with bronchiolitis. Future studies should assess the role of Parachlamydia in bronchiolitis.