921 resultados para Data Storage Solutions
Resumo:
The rheological behavior of poly(ethylene glycol) of 1500 g·mol -1(PEG1500) aqueous solutions with various polymer concentrations (w = 0.05, 0.10, 0.15, 0.20 and 0.25) was studied at different temperatures (T = 283.15, 288.15, 293.15, 298.15 and 303.15) K. The analyses were carried out considering shear rates ranging from (20 to 350) s-1, using a cone-and-plate rheometer under controlled stress and temperature. Classical rheological models (Newton, Bingham, Power Law, Casson, and Herschel-Bulkley) were tested. The Power Law model was shown suitable to mathematically represent the rheological behavior of these solutions. Well-adjusted empirical models were derived for consistency index variations in function of temperature (Arrhenius-type model; R2 > 0.96), polymer concentration (exponential model; R2 > 0.99) or the combination of both (R 2 > 0.99). Additionally, linear models were used to represent the variations of behavior index in the functions of temperature (R2 > 0.83) and concentration (R2 > 0.87). © 2013 American Chemical Society.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
As Redes de Sensores Sem Fio possuem capacidades limitadas de processamento, armazenamento, comunicação (largura de banda) e fonte de energia, além de possuírem características e requisitos básicos de uma RSSF como: necessidade de se auto-organizar, comunicação com difusão de curto alcance e roteamento com múltiplos saltos. Neste trabalho é proposto uma ferramenta que otimize o posicionamento e os pacotes entregues através do uso de Algoritmo Genético (AG). Para solucionar o problema de roteamento que melhore o consumo de energia e maximize a agregação de dados é proposto a utilização de lógica fuzzy no protocolo de roteamento Ad hoc Ondemand Distance Vector (AODV). Esta customização é intitulada AODV – Fuzzy for Wireless Sensor Networks (AODV-FWSN). Os resultados mostram que a solução proposta é eficiente e consegue prolongar a vida útil da RSSF e melhorar a taxa de entrega de dados quando comparado com soluções similares.
Resumo:
Devido às suas características únicas, redes de sensores ópticos têm encontrado aplicação em muitos campos, como em Engenharia Civil, Engenharia Geotécnica, Aeronáutica, Energia e Indústrias de Petróleo & Gás. Soluções de monitoramento baseadas nessa tecnologia têm se mostrado particularmente rentáveis e podem ser aplicadas às estruturas de grande porte, onde centenas de sensores devem ser implantados para medições a longo prazo de diferentes parâmetros mecânicos e físicos. Sensores baseados em Grades de Bragg em fibra (FBGs) são a solução mais comumente utilizada no Monitoramento de Saúde Estrutural (SHM) e as medições são realizadas por instrumentos especiais conhecidos como interrogadores ópticos. Taxas de aquisição cada vez mais elevadas têm sido possíveis utilizando interrogadores ópticos mais recentes, o que dá origem a um grande volume de dados cuja manipulação, armazenamento, gerenciamento e visualização podem demandar aplicações de software especiais. Este trabalho apresenta duas aplicações de software de tempo real desenvolvidas para esses fins: Interrogator Abstraction (InterAB) e Web-based System (WbS). As inovações neste trabalho incluem a integração, sincronização, independência, segurança, processamento e visualização em tempo real, e persistência de dados ou armazenamento proporcionados pelo trabalho conjunto das aplicações desenvolvidas. Os resultados obtidos durante testes em laboratório e ambiente real demonstraram a eficiência, robustez e flexibilidade desses softwares para diferentes tipos de sensores e interrogadores ópticos, garantindo atomicidade, consistência, isolamento e durabilidade dos dados persistidos pelo InterAB e apresentados pelo WbS.
Resumo:
AIM: To evaluate the staining of esthetic orthodontic brackets by plaque disclosing solutions. METHODS: Two types of brackets manufactured by GAC/DENTSPLY(r) were evaluated: ceramic (n=30) and polycarbonate (n=30). The brackets were divided into 6 groups. Two control groups (n=6) were immersed in absolute ethanol: GI - ceramic brackets and GII - polycarbonate brackets. Four experimental groups (n=12) were immersed in different plaque disclosing solutions: GIII (ceramic brackets) and GIV (polycarbonate brackets) were immersed in Replak(r); GV (ceramic brackets) and GVI (polycarbonate brackets) were immersed in Replasul "S"(r). Relative quantitative analysis of the influence of plaque disclosing tablets on bracket staining was performed using reflectance spectrophotometry of stain deposition. Exploratory analysis of the data was performed using Analysis of Variance (ANOVA) in a 2x2 factorial setup (bracket x immersion) with additional treatments (controls). RESULTS: The results demonstrated that the ceramic brackets presented the highest amount of staining when Replasul "S"(r) was used (pd"0.05). However, when Replak(r) was used, no statistically significant difference was found in comparison with the control group (p>0.05). For polycarbonate brackets, staining was detected for both disclosing solutions (p>0.05). CONCLUSIONS: The disclosing solutions caused stain formation on polycarbonate brackets and, under the tested conditions, use of Replak(r) on ceramic brackets did not cause staining.
Color Stability of Resin Used for Caries Infiltration After Exposure to Different Staining Solutions
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Cassava leaves have been widely used as a protein source for ruminants in the tropics. However, these leaves contain high level of hydro-cyanic acid (HCN) and condensed tannins (CT). There are evidences that making hay can eliminate more than 90% of HCN and that long-term storage can reduce CT levels. A complete randomized design with four replicates was conducted to determine the effect of different storage times (0-control, 60, 90 and 120 days) on chemical composition, in vitro rumen fermentation kinetics, digestibility and energy value of cassava leaves hay. Treatments were compared by analyzing variables using the GLM procedure (SAS 9.1, SAS Institute, Inc., Cary, NC). Crude protein (CP) and ether extract (EE) of the cassava hay were not affected (P > 0.05) by storage time (17.7% and 3.0%, respectively). Neutral detergent fiber, acid detergent fiber, total carbohydrate and non-fiber carbohydrate were not affected either (P>0.05) by storage time (47.5, 32.6, 72.3 and 25.8% respectively). However, other parameters were influenced. CT was lower (P<0.05) in hay after 120 days of storage compared with control (1.75% versus 3.75%, respectively). Lignin and insoluble nitrogen in neutral detergent, analyzed without sodium sulfite, were higher (P<0.01) after 120 days of storage, compared with the control (11.22 versus 13.57 and 1.65 versus 3.81% respectively). This suggests that the CT has bound to the fiber or CP and became inactive. Consequently, the in vitro digestibility of organic matter (50.36%), total digestible nutrients (44.79%) and energy (1.61 Mcal/KgMS), obtained from gas production data at 72 h of incubation, has increased (P<0.05) with storage times (56.83%, 51.53% and 1.86 Mcal/KgMS, respectively). The chemical composition and fermentative characteristics of cassava hay suffered variations during the storage period. The best values were obtained after 90 days of storage. This is probably due to the reduction in condensed tannins.
Resumo:
Pigments of food and beverages could affect dental bleaching efficacy. The aim of this investigation was to evaluate color change and mineral loss of tooth enamel as well as the influence of staining solutions normally used by adolescent patients undergoing home bleaching. Initial hardness and baseline color were measured on enamel blocks. Specimens were divided into five groups (n = 5): G1 (control) specimens were kept in artificial saliva throughout the experiment (3 weeks); G2 enamel was exposed to 10% carbamide peroxide for 6 h daily, and after this period, the teeth were cleaned and stored in artificial saliva until the next bleaching session; and G3, G4, and G5 received the same treatments as G2, but after bleaching, they were stored for 1 h in cola soft drink, melted chocolate, or red wine, respectively. Mineral loss was obtained by the percentage of hardness reduction, and color change was determined by the difference between the data obtained before and after treatments. Data were subjected to analysis of variance and Fisher's test (a = 0.05). G3 and G5 showed higher mineral loss (92.96 +/- 5.50 and 94.46 +/- 1.00, respectively) compared to the other groups (p = 0.05). G5 showed high-color change (9.34 +/- 2.90), whereas G1 presented lower color change (2.22 +/- 0.44) (p = 0.05). Acidic drinks cause mineral loss of the enamel, which could modify the surface and reduce staining resistance after bleaching. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. Removable partial dentures are affected by fatigue because of the cyclic mechanism of the masticatory system ansi frequent insertion and removal. Titanium and its alloys have been used in the manufacture of denture frameworks; however, preventive agents with fluorides are thought to attack titanium alloy surfaces.Purpose. This study evaluated, compared, analyzed the corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different storage environments.Material and methods. For each metal, 33 dumbbell rods, 2.3 mm in diameter at the central segment, were cast in the Rematitan system. Corrosion-fatigue strength test was carried out through a universal testing machine with a load 30% lon er than the 0.2% offset yield strength and a combined influence of different: environments: in air at room temperature, with synthetic saliva, and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and fracture surfaces were examined with on SEM.Results. ANOVA and Tukey's multiple comparison rest indicated that Ti-6Al-4V alloy achieved 21,269 cycles (SD = 8,355) against 19,157 cycles (SD = 3,624) for the commercially purr Ti. There were no significant differences between either metal in the corrosion-fatigue life for dry specimens, but when the solutions were present, the fatigue life was significantly reduced, probably because of the product-ion of corrosion pits caused by superficial reactions.