737 resultados para screw loosening


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, new promising proton conducting fuel cell membrane materials were characterized in terms of their structure and dynamic properties using solid-state nuclear magnetic resonance (NMR) spectroscopy and X-ray diffraction. Structurally different, phosphonic acid (PA) containing materials were systematically evaluated for possible high-temperature operation (e.g. at T>100°C). Notably, 1H, 2H and 31P magic angle spinning (MAS) NMR provided insight into local connectivities and dynamics of the hydrogen bonded network, while packing arrangements were identified by means of heteronuclear dipolar recoupling techniques.rnThe first part of this work introduced rather crystalline, low molecular weight ionomers for proton conducting membranes, where six different geometries such as line, triangle, screw, tetrahedron, square and hexagon, were investigated. The hexagon was identified as the most promising geometry with high-temperature bulk proton conductivities in the range of 10-3 Scm-1 at a relative humidity of 50%. However, 2H NMR and TGA-MS data suggest that the bulk proton transport is mainly due to the presence of crystal water. Single crystal X-ray data revealed that in the tetrahedron phosphonic acids form tetrameric clusters isolating the mobile protons while the phosphonic acids in the hexagon form zigzag-type pathways through the sample.rnThe second part of this work demonstrates how acid-base pairing and the choice of appropriate spacers may influence proton conduction. Different ratios of statistical copolymers of poly (vinylphosphonic acid) and poly (4-vinylpyridine) were measured to derive information about the local structure and chemical changes. Though anhydrous proton conductivities of all statistical copolymers are rather poor, the conductivity increases to 10-2 S cm-1 when exposing the sample to relative humidity of 80%. In contrast to PVPA, anhydride formation of phosphonic acids in the copolymer is not reversible even when exposing the sample to a relative humidity of 100%.rnIn addition, the influence of both spacers and degree of backbone crystallinity on bulk proton conductivity was investigated. Unlike in systems such as poly benzimidazole (PBI), spacers were inserted between the protogenic groups along the backbone. It was found that dilution of the protogenic groups decreases the conductivity, but compared to PVPA, similar apparent activation energies for local motions were obtained from both variable temperature 1H NMR and impedance spectroscopy data. These observations suggest the formation of phosphonic acid clusters with high degrees of local proton motion, where only a fraction of motions contribute to the observable bulk proton conductivity. Additionally, it was shown that gradual changes of the spacer length lead to different morphologies.rnIn summary, applying advanced solid-state NMR and X-ray analysis, structural and dynamic phenomena in proton conducting materials were identified on a molecular level. The results were discussed with respect to different proton conduction mechanisms and may contribute to a more rational design or improvement of proton conducting membranes.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aseptic loosening of metal implants is mainly attributed to the formation of metal degradation products. These include particulate debris and corrosion products, such as metal ions (anodic half-reaction) and ROS (cathodic half-reaction). While numerous clinical studies describe various adverse effects of metal degradation products, detailed knowledge of metal-induced cellular reactions, which might be important for possible therapeutic intervention, is not comprehensive. Since endothelial cells are involved in inflammation and angiogenesis, two processes which are critical for wound healing and integration of metal implants, the effects of different metal alloys and their degradation products on these cells were investigated. Endothelial cells on Ti6Al4V alloy showed signs of oxidative stress, which was similar to the response of endothelial cells to cathodic partial reaction of corrosion induced directly on Ti6Al4V surfaces. Furthermore, oxidative stress on Ti6Al4V alloy reduced the pro-inflammatory stimulation of endothelial cells by TNF-α and LPS. Oxidative stress and other stress-related responses were observed in endothelial cells in contact with Co28Cr6Mo alloy. Importantly, these features could be reduced by coating Co28Cr6Mo with a TiO2 layer, thus favouring the use of such surface modification in the development of medical devices for orthopaedic surgery. The reaction of endothelial cells to Co28Cr6Mo alloy was partially similar to the effects exerted by Co2+, which is known to be released from metal implants. Co2+ also induced ROS formation and DNA damage in endothelial cells. This correlated with p53 and p21 up-regulation, indicating the possibility of cell cycle arrest. Since CoCl2 is used as an hypoxia-mimicking agent, HIF-1α-dependence of cellular responses to Co2+ was studied in comparison to anoxia-induced effects. Although important HIF-1α-dependent genes were identified, a more detailed analysis of microarray data will be required to provide additional information about the mechanisms of Co2+ action. All these reactions of endothelial cells to metal degradation products might play their role in the complex processes taking place in the body following metal device implantation. In the worst case this can lead to aseptic loosening of the implant and requirement for revision surgery. Knowledge of molecular mechanisms of metal-induced responses will hopefully provide the possibility to interfere with undesirable processes at the implant/tissue interface, thus extending the life-time of the implant and the overall success of metal implant applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Der Gemeine Ohrwurm (Forficula auricularia LINNAEUS 1758) wurde bisher im Weinbau als natürlicher Gegenspieler verschiedener Rebschädlinge zu den Nützlingen gezählt. Etwa seit 2005 verursacht er aufgrund stark ansteigender Populationsdichten Schäden in pfälzischen Rebanlagen. Ohrwürmer halten sich massenhaft in den Trauben auf. Zusammen mit ihren Exkrementen geraten sie bei der Lese in großer Zahl ins Erntegut. Die Tiere werden von der weinbaulichen Praxis als sehr störend und qualitätsmindernd empfunden und ihre Einstufung als Nützling kritisch gesehen. Aufgrund dieser Problematik wurde im Mai 2007 ein durch den Forschungsring des Deutschen Weinbaus (FDW) finanziertes Forschungsprojekt am Dienstleistungszentrum Ländlicher Raum Rheinpfalz in Neustadt an der Weinstraße begonnen. Bis 2010 wurden offene Fragen zur Erfassung und Populationsbiologie des Gemeinen Ohrwurms in Rebanlagen bearbeitet, die von ihm verursachten Schäden beschrieben und Strategien zu seiner Befallsregulation entwickelt. Am Boden aktive Ohrwürmer wurden mit Bodenfallen nach BARBER (1931) aufgenommen. In der Laubwand des Rebstockes wurden die Ohrwürmer mit eigens konzipierten Bambusfallen erfasst. F. auricularia ist in pfälzischen Rebanlagen die dominierende Ohrwurm-Art. Im Projektverlauf wurde der univoltine Entwicklungszyklus des Gemeinen Ohrwurms in pfälzischen Rebanlagen vollständig aufgeklärt. In der Vegetationsperiode beeinflussten die Intensität der Bodenbewirtschaftung mit der resultierenden Flächenbegrünung, die Bodenart, die Lufttemperatur, die Luftfeuchtigkeit und die Niederschlagsmenge die Befallsdichten am Rebstock signifikant. Der Ohrwurm-Befall in den Trauben war signifikant von der Kompaktheit und vom Gewicht der Trauben sowie dem Fäulnisanteil pro Traube und von eingewachsenen Rebblättern in den Trauben abhängig. Das Überwinterungs- und Brutverhalten wurde durch die Art und Weise der Bodenbewirtschaftung beeinflusst beziehungsweise gestört.rnLabor- und Freilandversuche haben gezeigt, dass F. auricularia Pilzpathogene wie die Graufäule (Botrytis cinerea PERSOON 1794) und den Pinselschimmel (Penicillium crustosum THOM 1930) auf gesunde Trauben überträgt. Ferner haben Fraßversuche ergeben, dass der Ohrwurm nur faule und vorgeschädigte Beeren anfressen kann und keine intakten Beeren verletzt. Durch analytische und sensorische Untersuchungen wurde festgestellt, dass Ohrwurm-Kot sensorische Fehltöne im Wein verursachen kann. Diese werden durch das im Kot enthaltene 2-Methyl-1,4-benzochinon hervorgerufen, das eine Komponente des arteigenen Abwehrsekrets ist. Da sich der Ohrwurm jahreszeitlich bedingt entweder im Boden oder am Rebstock aufhält, wurden befallsregulierende Maßnahmen im Boden- und Laubwandbereich der Rebanlage durchgeführt. Durch Tiefengrubbern mit Umbruch der Begrünung im Herbst und Frühjahr wurden die überwinternden Imagines und die Gelege geschädigt, so dass in der darauf folgenden Vegetationsperiode die Befallsdichten in der Laubwand geringfügig aber nicht signifikant abnahmen. Die während der Aufwanderungsphase der Ohrwürmer Ende Juni durchgeführte mechanische Störung der Begrünung reduzierte den Ohrwurm-Befall am Rebstock bis zu drei Wochen nach der Maßnahme signifikant. In der Laubwand der Rebstöcke wurden die Befallsdichten durch die Insektizide SpinTor (Wirkstoff Spinosad: 0,01%) und Steward® (Wirkstoff Indoxacarb: 0,0125 %) sowie sekundär durch partielles Entblättern der Laubwand dauerhaft bis zur Traubenlese reduziert. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gegenstand der Arbeit: Die distale Radiusfraktur ist der häufigste Bruch des Menschen. Neben etablierten Verfahren wie der dorsalen und palmaren Plattenosteosynthese gibt es seit Kurzem neuartige minimalinvasive Osteosynthesesysteme. Gegenstand der vorliegenden Arbeit ist die Untersuchung der biomechanischen Stabilität von zwei neuartigen Implantaten für die distale extraartikuläre Radiusfraktur. rnMethodik: Es handelt sich einerseits um das System XSCREW (Zimmer, Freiburg i. Br., Deutschland), eine kanülierte Schraube, die über den Processus styloideus eingeführt wird und mit bis zu neun Bohrdrähten im Knochen fixiert werden kann. Das Vergleichsimplantat DorsalNailPlate (HandInnovations, Miami, Florida, USA) ist ein Hybrid aus einer dorsalen Platte und einem Marknagel. Beide Systeme wurden an 8 paarigen frischen unfixierten Leichenradii unter Axialbelastung bis 100 N und Torsionsbelastung bis 1,5 Nm getestet. Die A3-Fraktur wurde durch eine standardisierte Keilosteotomie simuliert. Das Biomaterial wurde prä- und postinterventionell sowie nach einem Dauerbelastungstest unter 1000 Zyklen in Rotation mit 0,5 Hz untersucht. Ein Versagenstest mit steigendem Drehmoment beendete das Experiment. rnErgebnisse: Die XSCREW erreichte eine Axialsteifigkeit von 136 N/mm und eine Torsionssteifigkeit von 0,16 Nm/°. Die DNP erzielte hingegen axial 70 N/mm und torsional 0,06 Nm/°. Der Unterschied zwischen beiden Verfahren war nur für die Torsion eindeutig statistisch auffällig (p=0,012), jedoch nicht für die Axialsteifigkeit (p=0,054). Die ursprüngliche Axial- und Torsionssteifigkeit wurde durch die XSCREW signifikant besser wiederhergestellt als durch die DNP (p=0,012). Beide Verfahren erzielten nach der Intervention signifikant niedrigere Steifigkeiten als die intakten Knochen (p=0,012). Ein Präparat der DNP-Gruppe und vier Präparate der XSCREW-Gruppe überstanden den Dauerbelastungstest. Das Drehmoment bei Versagen war mit der XSCREW höher als mit der DNP, der Unterschied zwischen den Verfahren war signifikant (p=0,043). Die Schwachstellen beider Systeme lagen vorwiegend in der proximalen Verankerung im Knochen. Kirschner-Drähte bzw. Verriegelungsschrauben führten unter andauernder Belastung zu einer Spaltung der Kortikalis im Schaftbereich. Bedingt durch die Ausrichtung der distalen Verriegelungen können mit beiden Implantaten Schäden an der radiocarpalen bzw. radioulnaren Gelenkfläche entstehen. rnZusammenfassung: Die XSCREW ermöglicht insgesamt eine höhere mechanische Stabilität als die DNP. Beide Verfahren sind jedoch einer winkelstabilen palmaren Plattenosteosynthese insbesondere unter rotatorischer Dauerbelastung unterlegen und erreichen nicht die Stabilität eines anderen neuartigen minimalinvasiven Systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goals of any treatment of cervical spine injuries are: return to maximum functional ability, minimum of residual pain, decrease of any neurological deficit, minimum of residual deformity and prevention of further disability. The advantages of surgical treatment are the ability to reach optimal reduction, immediate stability, direct decompression of the cord and the exiting roots, the need for only minimum external fixation, the possibility for early mobilisation and clearly decreased nursing problems. There are some reasons why those goals can be reached better by anterior surgery. Usually the bony compression of the cord and roots comes from the front therefore anterior decompression is usually the procedure of choice. Also, the anterior stabilisation with a plate is usually simpler than a posterior instrumentation. It needs to be stressed that closed reduction by traction can align the fractured spine and indirectly decompress the neural structures in about 70%. The necessary weight is 2.5 kg per level of injury. In the upper cervical spine, the odontoid fracture type 2 is an indication for anterior surgery by direct screw fixation. Joint C1/C2 dislocations or fractures or certain odontoid fractures can be treated with a fusion of the C1/C2 joint by anterior transarticular screw fixation. In the lower and middle cervical spine, anterior plating combined with iliac crest or fibular strut graft is the procedure of choice, however, a solid graft can also be replaced by filled solid or expandable vertebral cages. The complication of this surgery is low, when properly executed and anterior surgery may only be contra-indicated in case of a significant lesion or locked joints.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates 3-year success rates of titanium screw-type implants with a chemically modified sandblasted and acid-etched surface (mod SLA), which were functionally loaded after 3 weeks of healing. METHODS: A total of 56 implants, inserted in the posterior mandibles of 39 partially edentulous patients, underwent undisturbed healing for 3 weeks. At day 21, the implants were fully loaded with provisional crowns. Definitive metal ceramic restorations were fabricated after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 36 months after implant placement. The soft tissue and radiographic parameters for the mod SLA implants after 3 years in function were compared to a historic control group of implants with an SLA surface using an early loading protocol after 6 weeks. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and were left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants, including the "spinners," showed favorable clinical and radiographic findings at the 3-year follow-up examination. All 56 implants were considered successfully integrated, resulting in a 3-year survival and success rate of 100%. Dental implants with a mod SLA surface demonstrated statistically significant differences for probing depths and clinical attachment level values compared to the historic control group, with the mod SLA surface implants having overall lower probing depths and clinical attachment level scores. CONCLUSION: This prospective study using an early loading protocol demonstrates that titanium implants with the mod SLA surface can achieve and maintain successful tissue integration over a period of 3 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. MATERIAL AND METHODS: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations in full occlusion. Definitive metal ceramic restorations were fabricated and positioned on each implant after 6 months of healing. Clinical measurements regarding soft tissue parameters and radiographs were obtained at different time points up to 24 months after implant placement. RESULTS: Of the 89 inserted implants, two (2.2%) implants failed to integrate and were removed during healing, and two (2.2%) additional implants required a prolonged healing time. A total of 85 (95.6%) implants were therefore loaded without incident after 21 days of healing. No additional implant was lost throughout the study period, whereas one implant was lost to follow-up and therefore left unaccounted for further analysis. The remaining 86 implants all exhibited favorable radiographic and clinical findings. Based on strict success criteria, these implants were considered successfully integrated 2 years after insertion, resulting in a 2-year success rate of 97.7%. CONCLUSION: The results of this prospective two-center study demonstrate that titanium implants with a modified SLA surface can predictably achieve successful tissue integration when loaded in full occlusion 21 days after placement. Integration could be maintained without incident for at least 2 years of follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seven patients with symptomatic osteochondritic lesions of the femoral head are presented. All were male with a mean age of 26 years (16 - 33 years). Two distinct morphologic appearances of the hip joint could be identified. Five patients presented with a coxa valga deformity, four of whom had signs of epiphyseal dysplasia. There were 2 patients whose hips appeared normal apart from the osteochondrontic lesions. In both cases an additional acetabular rim lesion due to a reproducible femoro-acetabular impingement was diagnosed at arthrotomy. This may have acted as the underlying cause of osteochondritis dissecans in these cases. All 7 patients underwent surgical treatment. An intertrochanteric osteotomy (I.O.) alone was performed in 2 patients. Follow-up of these patients at 6.5 and 8.5 years after surgery revealed that the osteochondritic lesions had not healed and one individual remained symptomatic. In the remaining 5 patients, treatment consisted of femoral head dislocation and screw fixation of the osteochondritic lesion. This was combined with an I.O. in two of these patients for coxa valga and osteoplasty of a broad femoral neck in 2 other patients. All lesions had healed at an average follow-up of 4.3 years (2 - 8.5 years). Three patients were asymptomatic and 2 patients had minor residual pain. No progressive osteoarthritic changes or signs of avascular necrosis of the femoral head were observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an automated solution for precise detection of fiducial screws from three-dimensional (3D) Computerized Tomography (CT)/Digital Volume Tomography (DVT) data for image-guided ENT surgery. Unlike previously published solutions, we regard the detection of the fiducial screws from the CT/DVT volume data as a pose estimation problem. We thus developed a model-based solution. Starting from a user-supplied initialization, our solution detects the fiducial screws by iteratively matching a computer aided design (CAD) model of the fiducial screw to features extracted from the CT/DVT data. We validated our solution on one conventional CT dataset and on five DVT volume datasets, resulting in a total detection of 24 fiducial screws. Our experimental results indicate that the proposed solution achieves much higher reproducibility and precision than the manual detection. Further comparison shows that the proposed solution produces better results on the DVT dataset than on the conventional CT dataset.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To compare the gene expression profile of osseointegration associated with a moderately rough and a chemically modified hydrophilic moderately rough surface in a human model. MATERIAL AND METHODS: Eighteen solid screw-type cylindrical titanium implants, 4 mm long and 2.8 mm wide, with either a moderately rough (SLA) or a chemically modified moderately rough (SLActive) surface were surgically inserted in the retromolar area of nine human volunteers. The devices were removed using a trephine following 4, 7 and 14 days of healing. The tissue surrounding the implant was harvested, total RNA was extracted and microarray analysis was carried out to identify the differences in the transcriptome between the SLA and SLActive surfaces at days 4, 7 and 14. RESULTS: There were no functionally relevant gene ontology categories that were over-represented in the list of genes that were differentially expressed at day 4. However, by day 7, osteogenesis- and angiogenesis-associated gene expression were up-regulated on the SLActive surface. Osteogenesis and angiogenesis appeared to be regulated by BMP and VEGF signalling, respectively. By day 14, VEGF signalling remains up-regulated on the SLActive surface, while BMP signalling was up-regulated on the SLA surface in what appeared to be a delayed compensatory response. Furthermore, neurogenesis was a prominent biological process within the list of differentially expressed genes, and it was influenced by both surfaces. CONCLUSIONS: Compared with SLA, SLActive exerts a pro-osteogenic and pro-angiogenic influence on gene expression at day 7 following implant insertion, which may be responsible for the superior osseointegrative properties of this surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Distraction of the periosteum results in the formation of new bone in the gap between the periosteum and the original bone. We postulate that the use of a barrier membrane would be beneficial for new bone formation in periosteal distraction. Methods: To selectively influence the contribution of the periosteum, a distraction plate with perforations was used alone or covered by a collagen barrier membrane. All animals were subjected to a 7-day latency period and a 10-day distraction period with a rate of 0.1 mm/day. Four animals per group with or without a barrier membrane were sacrificed at 2, 4, and 6 weeks after the end of the distraction. The height of new bone generated relative to the areas bound by the parent bone and the periosteum was determined by histomorphometric methods. Results: New bone was found in all groups. At the periphery of the distraction plate, significant differences in bone height were found between the hinge and the distraction screw for the group without barrier membrane at 2 weeks (0.39 ± 0.19 mm) compared to 4 weeks (0.84 ± 0.44 mm; P = 0.002) and 6 weeks (1.06 ± 0.39 mm; P = 0.004). Differences in maximum bone height with and without a barrier membrane were observed laterally to the distraction plate at 2 weeks (1.22 ± 0.64 versus 0.55 ± 0.14 mm; P = 0.019) and 6 weeks (1.61 ± 0.56 versus 0.73 ± 0.33 mm; P = 0.003) of the consolidation period. Conclusion: Within the limitations of the present study, the application of a barrier membrane may be considered beneficial for new bone formation induced by periosteal distraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: A recent in vivo study has shown considerable contamination of internal implant and suprastructure components with great biodiversity, indicating bacterial leakage along the implant-abutment interface, abutment-prosthesis interface, and restorative margins. The goal of the present study was to compare microbiologically the peri-implant sulcus to these internal components on implants with no clinical signs of peri-implantitis and in function for many years. Checkerboard DNA-DNA hybridization was used to identify and quantify 40 species. Material and Methods: Fifty-eight turned titanium Brånemark implants in eight systemically healthy patients (seven women, one man) under regular supportive care were examined. All implants had been placed in the maxilla and loaded with a screw-retained full-arch bridge for an average of 9.6 years. Gingival fluid samples were collected from the deepest sulcus per implant for microbiological analysis. As all fixed restorations were removed, the cotton pellet enclosed in the intra-coronal compartment and the abutment screw were retrieved and microbiologically evaluated. Results: The pellet enclosed in the suprastructure was very similar to the peri-implant sulcus in terms of bacterial detection frequencies and levels for practically all the species included in the panel. Yet, there was virtually no microbial link between these compartments. When comparing the abutment screw to the peri-implant sulcus, the majority of the species were less frequently found, and in lower numbers at the former. However, a relevant link in counts for a lot of bacteria was described between these compartments. Even though all implants in the present study showed no clinical signs of peri-implantitis, the high prevalence of numerous species associated with pathology was striking. Conclusions: Intra-coronal compartments of screw-retained fixed restorations were heavily contaminated. The restorative margin may have been the principal pathway for bacterial leakage. Contamination of abutment screws most likely occurred from the peri-implant sulcus via the implant-abutment interface and abutment-prosthesis interface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonunions of pediatric subtrochanteric femur fractures are exceedingly rare and have to date not been reported in the literature. We present the case of an 11-year-old boy who developed such a nonunion after open reduction internal fixation using a pediatric locked proximal femur plate. Using an adult proximal humerus locking plate, adequate proximal fixation of the nonunion was obtained. Furthermore, previously placed distal screw holes were safely bridged and the biomechanical environment around the nonunion site improved. Uneventful healing was possible with the use of adjuvant bone grafting. No short- or midterm complications occurred. Although other implants can certainly be adapted to a use different than that of its original design, the present case suggests that adult proximal humerus locking plates may be a safe option for revision surgery of the proximal pediatric femur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid-state shear pulverization (SSSP) is a unique processing technique for mechanochemical modification of polymers, compatibilization of polymer blends, and exfoliation and dispersion of fillers in polymer nanocomposites. A systematic parametric study of the SSSP technique is conducted to elucidate the detailed mechanism of the process and establish the basis for a range of current and future operation scenarios. Using neat, single component polypropylene (PP) as the model material, we varied machine type, screw design, and feed rate to achieve a range of shear and compression applied to the material, which can be quantified through specific energy input (Ep). As a universal processing variable, Ep reflects the level of chain scission occurring in the material, which correlates well to the extent of the physical property changes of the processed PP. Additionally, we compared the operating cost estimates of SSSP and conventional twin screw extrusion to determine the practical viability of SSSP.