948 resultados para ring oscillator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many zeranol immunoassay test kits cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the evaluation and application of recently published, dry reagent time-resolved fluoroimmunoassays (TR-FIA) for zeranol and the toxin alpha-zearalenol. A ring test of bovine urine fortified with zeranol and/or alpha-zearalenol in four European Union National Reference Laboratories demonstrated that the TR-FIA tests were accurate and robust. The alpha-zearalenol TR-FIA satisfactorily quantified alpha-zearalenol in urine fortified at 10-30 ng ml(-1) . The specificity-enhanced zeranol TR-FIA accurately quantified zeranol in the range 2-5 ng ml(-1) and gave no false-positive results in blank urine, even in the presence of 30 ng ml(-1) alpha-zearalenol. Zeranol TR-FIA specificity was demonstrated further by analysing incurred zeranol-free urine samples containing natural Fusarium spp. toxins. The TR-FIA yielded no false-positive results in the presence of up to 22 ng ml(-1) toxins. The performance of four commercially available zeranol immunoassay test kits was more variable. Three kits produced many false-positive results. One kit produced only one potential false-positive using a protocol that was longer than that of the TR-FIA. These TR-FIAs will be valuable tools to develop inspection criteria to distinguish illegal zeranol abuse from contamination arising from in vivo metabolism of Fusarium spp. toxins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A report is presented on a split ring slot frequency selective surface (FSS) reflector whose element design and distribution allows generation of far-field difference patterns. The reflector operates by converting linearly polarised plane wave fronts into two orthogonal polarisations each with a deep null in the centre of the radiation pattern. The far-field measurement presented is in good agreement with the simulation and demonstrates a null depth of ?20dB in the centre of the radiation pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the use of periodic arrays of freestanding slot frequency-selective screens (FSS) as a means for generating circularly polarised signals from an incident linearly polarised signal at normal incidence to the structure. Measured and simulated results for crossed, linear and various ring slot element shapes in single and double-layer polarisation convertor structures are presented for 10 GHz operation. It is shown that 3 dB axial ratio (AR) bandwidths of 21% can be achieved with the one-layer perforated screen design and that the rate of change is lower than the double-layer structures. An insertion loss of 0.34 dB can be achieved for the split circular ring double-layer periodic array, and of the three topologies presented the hexagonal split-ring polarisation convertor gives the lowest variation of AR with angle of incidence 1.8 dB/45° and 3.6 dB/45° for the single and double-screen FSS, respectively. In addition, their tolerance to angle of incidence variation is presented. The capability of the surfaces reported here as twist polariser or spatial isolator components has been demonstrated with up to -30 dB isolation between incident and re-reflected signals for the double-layer designs being measured. © 2010 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter gives the first report of a planar phase plate structure based on frequency selective surface (FSS) technology for the generation of helical far-field radiation patterns with circular polarization properties.The unit cell of the structure comprises two orthogonal split-ring resonators designed to ensure 180$^{\circ}$ phase shift between orthogonal transmission coefficients. This property is exploited to obtain progressive rotational phase shift within the structure and thus synthesize 360$^{\circ}$ spiral phase profile. Measured far-field radiation patterns demonstrate spiral phase front generation for 10-GHz circularly polarized waves transmitted through the structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic myelomonocytic leukemia is similar to but a separate entity from both myeloproliferative neoplasms and myelodysplastic syndromes, and shows either myeloproliferative or myelodysplastic features. We ask whether this distinction may have a molecular basis. We established the gene expression profiles of 39 samples of chronic myelomonocytic leukemia (including 12 CD34-positive) and 32 CD34-positive samples of myelodysplastic syndromes by using Affymetrix microarrays, and studied the status of 18 genes by Sanger sequencing and array-comparative genomic hybridization in 53 samples. Analysis of 12 mRNAS from chronic myelomonocytic leukemia established a gene expression signature of 122 probe sets differentially expressed between proliferative and dysplastic cases of chronic myelomonocytic leukemia. As compared to proliferative cases, dysplastic cases over-expressed genes involved in red blood cell biology. When applied to 32 myelodysplastic syndromes, this gene expression signature was able to discriminate refractory anemias with ring sideroblasts from refractory anemias with excess of blasts. By comparing mRNAS from these two forms of myelodysplastic syndromes we derived a second gene expression signature. This signature separated the myelodysplastic and myeloproliferative forms of chronic myelomonocytic leukemias. These results were validated using two independent gene expression data sets. We found that myelodysplastic chronic myelomonocytic leukemias are characterized by mutations in transcription/epigenetic regulators (ASXL1, RUNX1, TET2) and splicing genes (SRSF2) and the absence of mutations in signaling genes. Myelodysplastic chronic myelomonocytic leukemias and refractory anemias with ring sideroblasts share a common expression program suggesting they are part of a continuum, which is not totally explained by their similar but not, however, identical mutation spectrum. © 2013 Ferrata Storti Foundation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A frequency selective surface (FSS) is described which exhibits coincident spectral responses for TE and TM polarisation when the FSS operates at 45 degrees incidence. The structure consists of two closely spaced arrays of ring elements with the conductor split at one or two locations to provide independent control of the resonances for the vertical and horizontal field directions. The FSS is designed to diplex two channels separated by an edge of a band ratio of 1.7:1 and yield a common - 10 dB reflection bandwidth of 10.2%. Measured and numerical results are shown to be in good agreement over the frequency range 9-12 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suitable ester prodrugs of 17b-estradiol are identified, thus permitting effective sustained and controlled estrogen replacement therapy (ERT) from an elastomeric, silicone intravaginal ring (IVR). IVR devices of reservoir design were prepared by blending silicone elastomer base with n-propylorthosilicate (cross-linker) and 10% w/w of 17b-estradiol or an ester prodrug, the mix being activated with 0.5% w/w stannous octoate and cured at 808C for 2 min. A rate-controlling membrane was similarly prepared, without the active agent. IVR devices were of cross-sectional diameter 9 mm, outer diameter 54 mm, with core cross-sectional diameter of 2 mm and core length varied as required. Sink conditions were evident for the 17b-estradiol esters in 1.0% aqueous benzalkonium chloride solution. The low release rates into 0.9% w/v saline of the lipophilic valerate and benzoate esters were due to their intrinsically low aqueous solubilities. In vivo, these esters failed to raise plasma estradiol above baseline levels in postmenopausal human volunteers, despite good in vitro release characteristics under sink conditions. The best release rates under sink conditions, in combination with substantial aqueous solubilities as indicated by the release rates into saline, were observed for the acetate and propionate esters. A
combination of drug release characteristics, short plasma half-life and a toxicologically acceptable hydrolysis product indicated that 17b-estradiol-3-acetate was the prodrug of choice for IVR delivery of ERT. In vivo, an IVR device releasing
100 mg/day of estradiol as its 3-acetate ester maintained over 84 days a circulating plasma concentration in the region of 300 pmol l , within the clinically desirable range for ERT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The non-destructive evaluation of the water permeability of concrete structures is a long standing challenge, principally due to the difficulty of achieving a uni-direction flow for computing the water permeability coefficient. The use of a guard ring (GR) was originally proposed for the in situ sorptivity test, but little information can be found for the water permeability test. In this study, the effect of a GR was carefully examined through the flow simulation, which was verified by carrying out experiments. It was observed that the GR can confine the flow near the surface, but cannot achieve a uni-directional flow across the whole depth of flow. To achieve a better performance, it is essential to consider the effects of the size of the inner seal and the GR and the significant interaction between these two. The analysis of the experimental data has indicated that the GR influences the flow for porous concretes, but there is no significant effect for dense concretes. Further investigation, validated using the flow-net theory, has shown a strong correlation between the water permeability coefficients obtained with the GR (K w-GR) and without it (K w-No GR), suggesting that one dimensional flow is not essential for interpreting data for site tests. Another practical issue was that more than 30 % of the tests with GR failed due to the difficulty of achieving a good seal between the inner and the outer chambers. Based on the work reported in this paper, a new water permeability test is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the estimation of purity for a quantum oscillator initially prepared in a displaced thermal state and probed by a suitably prepared qubit interacting with the oscillator via Jaynes-Cummings Hamiltonian without the rotating-wave approximation. We evaluate the quantum Fisher information (QFI) and show that optimal estimation of purity can be achieved by measuring the population of the qubit after a properly chosen interaction time. We also address the estimation of purity at fixed total energy and show that the corresponding precision is independent of the presence of a coherent amplitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the theory of quantum estimation in two different qubit-boson coupling models to demonstrate that the temperature of a quantum harmonic oscillator can be estimated with high precision by quantum-limited measurements on the qubit. The two models that we address embody situations of current physical interest due to their connection with ongoing experimental efforts on the control of mesoscopic dynamics. We show that population measurements performed over the qubit probe are near optimal for a broad range of temperatures of the harmonic oscillator.