993 resultados para maximum-intensity projection
Resumo:
In smart grids context, the distributed generation units based in renewable resources, play an important rule. The photovoltaic solar units are a technology in evolution and their prices decrease significantly in recent years due to the high penetration of this technology in the low voltage and medium voltage networks supported by governmental policies and incentives. This paper proposes a methodology to determine the maximum penetration of photovoltaic units in a distribution network. The paper presents a case study, with four different scenarios, that considers a 32-bus medium voltage distribution network and the inclusion storage units.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
Dissertação de Mestrado, Vulcanologia e Riscos Geológicos, 25 de Novembro de 2013, Universidade dos Açores.
Resumo:
A Obesidade é considerada um grave problema de saúde pública, com consequências negativas para os indivíduos obesos, nomeadamente dificuldades no desempenho de atividades de vida diária, na locomoção e na prática de exercício físico, o que pode restringir a participação em atividades sociais e de lazer. Esta investigação consiste num estudo quantitativo descritivo e tem como objetivo principal descrever de que forma os indivíduos adultos obesos classificam a sua adaptação ocupacional, a partir dos conceitos de identidade e competência ocupacional. Com este estudo, pretende-se ainda verificar se os indivíduos obesos apresentam níveis de atividade física mais baixos e valores mais elevados de pressão plantar, em relação a indivíduos com peso normal. A amostra é constituída por dez indivíduos adultos, de ambos os sexos, com índice de massa corporal igual (IMC) ou superior a 30 Kg/m2, e os instrumentos de avaliação utilizados são o Questionário Ocupacional (adaptado por N. Riopel com assistência de G. Kielhofner e J. Hawkins Watts – 1986), o IPAQ – Versão Curta e o Sistema de Palmilhas Pedar. A partir dos resultados, pode-se verificar que os indivíduos obesos apresentam uma rotina diária em que a maioria das atividades realizadas está relacionada com a casa, o trabalho e o descanso e que a percentagem de atividades de lazer em que participam é reduzida. No entanto, parecem satisfeitos com o seu desempenho na maior parte das atividades, consideram que muitas delas são importantes para si e estão motivados para as realizar. Dos resultados obtidos, podemos sugerir que os indivíduos obesos apresentam boa adaptação ocupacional. Pode-se ainda dizer que os indivíduos obesos apresentam um baixo nível de intensidade de atividade física, não se observando diferenças significativas relativamente aos indivíduos com peso normativo e que os seus valores máximos de pressão plantar normalizados são inferiores quando comparados com a população de peso normal.
Resumo:
Este trabalho teve como objectivo a optimização das condições de crescimento de biomassa algal tendo em vista a sua utilização como fonte de lípidos para biocombustíveis. Assim, procedeu-se à inoculação de duas estirpes, a Dunaliella tertiolecta (água salgada) e a Tetraselmis subcordiformis (água salobra), seleccionando-se a Dunaliella tertiolecta uma vez que esta apresentou um crescimento mais rápido. Escolhida a estirpe a usar, avaliou-se a influência da composição do meio de cultura da espécie, variando-se a concentração de macronutrientes (Magnésio, Potássio, Azoto, Fósforo) e de micronutrientes (Manganês, Zinco, Ferro, Cobalto) presentes no meio em 10 e 20 vezes, comparativamente à do meio de cultura padrão, o meio Artificial Seawater Medium with Vitamins. Avaliou-se o crescimento algal, a uma temperatura de 25 ºC ± 2 ºC, com uma intensidade de iluminação de 5000 lux (lâmpadas luz dia) e fotoperíodos 12:12 h, controlando possíveis contaminações nas culturas em estudo. Para os ensaios realizados com a Dunaliella tertiolecta, os melhores resultados para a produtividade média e máxima de biomassa, 63,06 mgbiomassa seca/L.dia e 141,79 mgbiomassa seca/L.dia, respectivamente, foram obtidos no ensaio em que se fez variar 10 vezes a concentração de azoto (sob a forma de nitrato). Os resultados mais satisfatórios para o teor lípidico e para a produtividade lipídica máxima, 33,45% e 47,43 mgóleo/L.dia respectivamente, também foram obtidos no ensaio em que se fez variar 10 vezes a concentração de azoto (sob a forma de nitrato), (com extracção dos lípidos usando o método de Bligh e Dyer). Foram testados dois solventes para a extracção de lipídos, o clorofórmio e o hexano, tendose obtido resultados superiores com o clorofórmio, comparativamente aos obtidos quando se usou hexano, com excepção do ensaio em que se aumentou 20 vezes a concentração de fósforo no meio de cultura das microalgas. Verificou-se que, em todos os ensaios foi atingido o estado estacionário sensivelmente na mesma altura, isto é, decorridos cerca de 25 dias após o início do estudo, excepto os ensaios em que se fez variar a concentração de cobalto, para os quais as culturas não se adaptaram às alterações do meio, acabando por morrer passados 15 dias. A adição dos macronutrientes e micronutrientes usados nos ensaios, nas quantidades testadas, não influenciou significativamente a produtividade lipídica, com excepção do azoto e ferro. Conclui-se que o aumento da concentração de azoto para 10x o valor padrão potencia o aumento da produtividade lipídica máxima para mais do dobro (3,6 vezes – Padrão: 13,25 mgóleo/L.dia; 10x N: 47,43 mgóleo/L.dia) e que o aumento da concentração de ferro para 10x o valor padrão potencia o aumento da produtividade lipídica máxima para aproximadamente o dobro (1,9 vezes - Padrão: 14,61 mgóleo/L.dia; 10x Fe: 28,04 mgóleo/L.dia). Nos ensaios realizados com adição de azoto ou ferro, os resultados obtidos para a concentração, teor lípidico e produtividade lipídica máxima, foram sempre superiores aos do padrão correspondente, pelo que se pode concluir que estes ensaios se apresentam como os mais promissores deste estudo, embora o ensaio mais satisfatório tenha sido aquele em que se promoveu a alteração da concentração de azoto para 10 vezes o valor padrão.
Resumo:
The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Mestrado em Radioterapia
Resumo:
In the last few years, the number of systems and devices that use voice based interaction has grown significantly. For a continued use of these systems, the interface must be reliable and pleasant in order to provide an optimal user experience. However there are currently very few studies that try to evaluate how pleasant is a voice from a perceptual point of view when the final application is a speech based interface. In this paper we present an objective definition for voice pleasantness based on the composition of a representative feature subset and a new automatic voice pleasantness classification and intensity estimation system. Our study is based on a database composed by European Portuguese female voices but the methodology can be extended to male voices or to other languages. In the objective performance evaluation the system achieved a 9.1% error rate for voice pleasantness classification and a 15.7% error rate for voice pleasantness intensity estimation.
Resumo:
Retinal imaging with a confocal scaning laser Ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced by measuring a sequence of slices at different depths. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images, if no processing is done. In this work, a prototype cSLO was modified in terms hardware and software to give the ability of doing the tomographic measurements with the maximum theoretical axial resolution possible. A model eye was built to test the performance of the system. A novel algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of images slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve topographic images and novel thickness images of the retina can be generated. Deconvolution algorithms have also been developed to improve the axial resolution of the system, using a theoretically predicted cSLO point spread function. The technique was evaluated using measurements made on a model eye, four normal eyes and seven eyes containing retinal pathology. The reproducibility, accuracy and physiological measurements obtained, were compared with available published data, and showed good agreement. The difference in the measurements when using a double rather than a single Gaussian model was also analysed.
Resumo:
Purpose: Evaluate the type of breast compression (gradual or no gradual) that provides less discomfort to the patient. Methods and Materials: The standard projections were simulated [craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast compressions in 90 volunteers women aged between 19 and 86. The women were organised in groups according to the breast density. The intensity of discomfort was evaluated using the scale that have represented several faces (0-10) proposed by Wong Baker in the end of each simulation. It was also applied an interview using focus group to debate the score that were attributed during pain evaluation and to identify the criteria that were considered to do the classification. Results: The women aged between 19-29y (with higher breast density) classified the pain during no gradual compression as 4 and the gradual compression as 2 for both projections. The MLO projection was considered the most uncomfortable. During the focus group interview applied to this group was highlighted that compression did not promoted pain but discomfort. They considered that the high expectations of pain did not correspond to the discomfort that they felt. Similar results were identified for the older women (30-50y; > 50y). Conclusion: The radiographers should considerer the technique for breast compression. The gradual compression was considered for the majority of the women as the most comfortable regardless of breast density. The MLO projection was considered as uncomfortable due to the positioning (axila and inclusion of pectoral muscle) and due to the higher breast compression compared to the CC projection.
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
Resumo:
This paper considers an international trade under Bertrand model with differentiated products and with unknown production costs. The home government imposes a specific import tariff per unit of imports from the foreign firm. We prove that this tariff is decreasing in the expected production costs of the foreign firm and increasing in the production costs of the home firm. Furthermore, it is increasing in the degree of product substitutability. We also show that an increase in the tariff results in both firms increasing their prices, an increase in both expected sales and expected profits for the home firm, and a decrease in both expected sales and expected profits for the foreign firm.